2007-443 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4E Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Pe nit Number. P20070443 Date Issued: Friday, January 30, 2009 This is to certify that work requested to be done as shown by Permit Number P20070443 has been completed. Location: JENKINSVILLE Rd Tax Map Number. 523400-279-000-0001-02 1-000-0000 Owner. TOWN OF QUEENSBURY Applicant: TOWN OF QUEENSBURY This structure may be occupied as a: Free Standing Unheated Building By Order of Town Board TOWN OF QUEENSBURY ,f Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070443 Application Number. A20070443 Tax Map No: 523400-279-000-0001-02 1-000-0000 Permission is hereby granted to: TOWN OF QUEENSBURY For property located at: JENKINSVILLE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TOWN OF QUEENSBURY Free Standing Unheated Buildin RECREATION DEPARTMENT PA 742 BAY Rd Total value QUEENSBURY,NY 12804-0000 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2007-443 FIELDHOUSE 1920 SQ FT $0.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,July 23, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To eens , nay,July 23,2007 SIGNED BY for the Town of Queensbury. Director of Building&Code nforcement i.......__.���....�y�F1.EUSEONLY ............./..._........% "r- .......... ... " " TAX MAP NO. o PERMIT NO. " FEES: PERMIT RECREATION ENGINEERING ; (If applicable) ; ..................................................................... ".................... PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: GJ VC1( . OWNER: OL" � e Q ADDRESS: -t Z f4 ADDRESS: ( `l '�] PHONE NOS. ` Z b PHONE NOS. S+e Va- CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: �11'nt�oo►� PHONE: `7a3-- 50`1� LOCATION OF PROPERTY: ^ T SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z W I- O APPLY TO YOUR Z 1= tr O N I.:W PROJECT �d O 1-- w 4 C = v z 4 ¢ <- � N � OI— 0ri CLX06 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS_) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGED,2,3) OTHER ,`��a�9u�t 1, Z0 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: � (,90,`Q 0 0 FUEL TYPE: HEAT TYPE: *HOW MANY FIREPLACE(S): _ AND/OR WOODSTOVES(S): ZONING CATEGORY: _ ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? N p nn (pv�c� ID s'S� PROPOSED USE OF BUILDING OR ADDITION: r7CA l�ra��S o�w " *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL t t-05 Tazon of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above ; ; This application / proposed action described Applicant to erect or alter the building o herein is found to be in accordance with the described herein in accordance with said 11 ; ; zoning Laws of the Town of Queensbury. Application: 0 01 1 , , , 00 BUILDIN &CO ROVAL ZONING APPROVAL + + , J , , , DATJ 11 ; DATE + , , QUESTIONS? CALL 761-8256 OR EMAIL codesft ueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION wWw^gueensburv.net Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 ..............•_------------•___--------------_•__- •___+ OFFICE USE ONLY 00A 0 TAX MAP NO. PERMIT NO. PERMIT FEE , ; ' 0 o APPROVALS: ZONING TOWN CLERK ,' " I _______________________________________ -----------------------1 0—_-___-______-.-__ APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: f64 ee1� INSTALLER: ADDRESS: >arm<�� � ADDRESS: PHONE NOS. PHONE NOS. LOCATION OF INSTALLATION: NO.OF RESIDENCE INFORMATION: BEDROOMS YEAR BUILT X COMPUTATION= TOTAL DAILY FLOW GARBAGE GRINDER 1980 or older X 150 gallon per bedroom = INSTALLED? 1981 -1991 X 130 gallon per bedroom = SPA OR HOT TUB 1992-present X 110 gallon per bedroom = INSTALLED? PARCEL INFORMATION: ee- ✓ TOPOGRAPHY: Flat rolling Steep slope %Slope ✓ SOIL NATURE: Sand Loam Clay Other ✓ GROUNDWATER: At what depth? ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? ✓ DOMESTIC WATER SUPLY: Municipal Well (If well: Water supply from any septic system absorption is ft.) ✓ PERCOLATION TEST: Rate is per minute per inch. (Test to be completed by a licensed professional engineer or architect.) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ft. Each trench X ❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size? ❑ ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. codes@queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensbury.net Signature of Person Responsible to ulTown of Queensbury • Community Development Office - 742 Bay Road, Queensbury,NY 12804 B 5-LGL 6/06 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensberry, NY 12804 4E 00 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Jenkinsville Athletic Fields 2007- 7/17/2007 I have completed review of the current submitted drawings and offer the following comments: 1) Change (4) emergency lighting fixtures shown to be combo paks, and relocate over the exit door or immediately adjacent to the exit door. 2) Truss ID signage is required, and should be shown on drawings 3) Provide details for any planned concession use in the kitchen area, other than vending. Note any future changes will need review by Building and Codes along with Fire Marshal for compliance. 4) Entrance gate locking feature must comply with 503.6 of the NYS Fire Code Fire Marshal Michael J Palmer 742 Bay Load Queensbury NY 12804 518 7618206 firemarshal@queensbury.net Fi r e M a r s h a l 's Off i c e - P h o n e: 518-761-8206 ■ F a x: 518-745-4437 firemarshal@queensburi/net • unuu7.queensbury.net w CHECKLIST - NYS BUILDING CODE(BC) Building: NYS FIRE CODE(FC) NYS PLUMBING CODE(PC) Location: e; ��, NYS MECHANICAL CODE(MC) NYS FUEL GAS CODE(FGC) Date: '7/1/7 NYS ENERGY CODE(ECC) Reviewer: 011- Publication Date: April 2005 � COMMERCIAL&t ��_o ISUS MULTIPLE DWELLING OCCUPANCIES No. Topic Code Page Required Actual Section No. or Allowed 1 jurisdiction BC-101.2 1 2 Flood Plain BC-1603.1.6 285 3 Separated or Non-Separated BC-302.3 18 Occupancies* 4 Occupancy BC-302 17 5 Type of Construction BC-Table 601 81 6 Truss I.D. 7 No.of Sleeping Units/Level BC-202 14&z No.of Units-Total 31 No.of Occupants BC-Table 1003.2.2.2 201 8 Covered Malls BC-402 33 Hi-Rise (75'Rule) BC-403 36 Atriums BC-404 37 9 Basement Definition BC-502.1 71 See page 8 of this check list Legend: NR=Not Required NS=Not Shown NA=Not Applicable Note: *Non-separated occupancies impose the most restrictive requirements Page 1 of 10 v No. Topic Code Page Required Actual Section No. or Allowed 10 Heights&c Building Areas Maximum Tabular Area BC-Table 503 72 Maximum Tabular Height BC-Table 503 72 Maximum Stories BC-Table 503 72 Mezzanines BC-505 73 11 Sprinkler System(water) BC-903 168 Basement Sprinkler BC-903.2.10.1 170 Water Source Sprinkler BC-903.3.5 172 Water Source Site FC-508.1 31 12. Frontage&r Sprinkler Credits Area Modifications(calc.) BC-506 74 Height Modifications BC-504 73 13. Height&t Area Summary: Ht/Area Ht/Area Tabular Area BC-Table 503 72 Frontage Credit BC-506 74 Sprinkler Credit BC-506.3 75 7060 Total Allowable Area Max Aggregate Area BC-503.3 73 (Allowable Area/Flr.x No.of Stories up to 3 maximum 14. Fire Apparatus Road FC-503.1 29 150'rule Hydrant Reg. FC 508.5 31 15. Exterior Walls Distance Separation* BC-Table 602 82 Exterior Wall Openings BC-Table 704.8 87 Parapets BC-704.11 88 Exterior Wall Coverings BC-Table 1405.2 257 Exterior Wall Finishes BC-Table 1406.2 261 Combustible *Distance separations are doubled if fire fighting water is not available(FC-508.1.3). NOTES: Page 2 of 10 Y No. Topic Code Page Required Actual Section No. or Allowed 16. Fire Rated Construction Incidental Use Areas BC-Table 302.1.1 17 Accessory Occupancy BC-302.2 18 Mixed Occupancy BC-Table 302.3.3 19 Control Areas BC-414.2 52 Fire Walls BC-705 89 ,/ Fire Barrier BC-706 91 Shaft Enclosure BC-707 92 Fire Partition(Tenant Sep.) BC-708 95 Smoke Barriers BC-709 96 Opening Protectives BC Table 714.2 101 Fire Blocking BC-716 107 Draft Stopping BC-716.3 108 Space ttic Accessory&rCrawl Space BC-1208 250 Min.Rm.Dimensions BC-1207.1 251 Q Min.Ceiling Height BC-1207.2 251 18. Ventilation Nat.or Mech. BC-1202.1 249 19. Li ht Nat. or Mech. BC-1204.1 250 20. Exits Remoteness BC-1004.2.2.1 218 Occupancy Load BC Table 1003.2.2.2 201 ,� One Exit Permitted BC Table 1005.2.2 224 V� Stair Enclosure BC-1005.3.2 224 Emergency Egress BC-1009.1 235 Distance of Travel BC-Table 1004.2.4 220 Aisle Width BC-1004.3.1.1 221 Corridor Width BC-1004.3.2.2 221 Capacity of Exits(calc.) BC-Table 1003.2.3 202 Corridor Wall Fire Rating BC-Table 1004.3.2.1 222 Corridor Dead End BC-1004.3.2.3 222 Door Width BC-1003.3.1.1 208 Door Swing BC-1003.3.1.2 208 Panic Hardware BC-1003.3.1.9 213 Canopies over Exits 21. Stairs Riser BC-1003.3.3.3 213 Tread BC-1003.3.3.3 213 l, Width BC-1003.3.3.1 213 Headroom BC-1003.3.3.2 213 Vertical Rise BC-1003.3.3.6 215 Handrails both sides BC-1003.3.3.11 215 Guards BC 1003.3.2.12 205 Max Rise 12'with landings BC-1003.3.36 215 Platform top&z bottom of BC-1003.3.3.4 214 stairs Page 3 of 10 i'- No. Topic Code - Page Required Actual Section No. or Allowed 22. Structural Snow Loading-Ground BC Fig 1608.2 296 Snow Loading-Roof(calc.) ASCE 7-98 Drifting Snow BC-1608.7 295 Ponding BC-1608.3.5 295 Floor Loading BC Table 1607.1 291 Balcony Loading BC-Table 1607.1 291 Wind Loading(calc.) BC-1609 297 Roof Walls Windows Seismic Loading(calc.) BC-1614 315 Foundation Depth BC-1805.2 398 23. Interior Finishes BC-Table 803.4 161 24. Swimming Pools BC-3109 629 25. Sun Rooms BC Appendix 1 693 26. Electrical Exit Lights or Signs BC-1003.2.10 203 Emergency Lights BC-1003.2.11.2 204 Emergency Power BC-2702 611 General Lighting-Exits- BC-1003.2.11 204 Stairs 27. HC-ACCESS Exempt Buildings BC-1104.4 238 Parking BC-Table 1106.1 239 Route BC-1104.1 238 Entrance BC-1105.1 239 #of Sleeping Rooms BC-Table-1107.6.1.1 241 #of Dwelling Units BC-1107.6.2 241 Toilet Facilities BC-1109.2 244 OZI- Service Counters BC-1109.12.3 246 Areas of Refuge BC-1003.2.13.5 207 Signage Supplemental HC Req'mts Appendix E 681 Push/Pull entrances door ANSI-A117.1-1998 approach 28. SPECIAL INSPECTIONS BC-1704 379 Notes: Contacts for concrete and structural inspection Page 4 of 10 No. Topic JnFC e762 Required Actual ionor Allowed 29. Fire Protection Equipment Central StationMon901.9Sprinkler Systems903Other Extinguishing904Kitchen HoodExting609.8Standpipe Systems905Fire Extinguishers906 Fire Alarm Systems&t SD FC-907.2 66 Fire Alarm Boxes&r Zones FC-907.4.1, 907.9 72, 73 Smoke Detection FC-907.2.10 68 Hi-Rise Fire Safety FC-907.2.12 69 Visible Alarms FC-Table 907.10.1.2 73 Smoke Control FC-909 75 Smoke Vents FC-910 82 Fire Pumps FC-913 85 Basements FC-903.2.10.1 56 Fan Shutdown 30. Plumbing Code Fixture Count PC-Table 403.1 21 Drinking Fountain,Service Sink Water Supply Service Pipe Size PC-603 33 Fixture Pipe Size PC-603.1 33 Pipe Material PC-Table 605.4 36 Labor Law Art. 10-A UFPBC-904.6 12,340 Pipe Insulation See Energy Code Backflow Prevention PC-Table 608.1 41 Sprinkler System PC-608.16.4 44 Lawn Irrigation PC-608.16.5 44 Pipe Freezing PC-305.6 14 Sanitary Drainage Drain Pipe Size PC-Table 709.1 54 Drain Pipe Material PC-702 47 Labor Law Art.10-A UFPBC-904.6 12,340 Vent size PC-Table 910.4 63 Pipe Hangers PC-Table 308.5 17 Air Admittance Valves PC-917 67 Notes: Page 5 of 10 a r3l.] Topic Code Page Required Actual Section No. Or Allowed Mechanical Code Ventilation Rates MC-Table 403.3 24 Propane Below Grade MC-502.8.10.1 31 Dryer Exhaust MC-504 33 Kitchen Exhaust MC-506 34 Kitchen Hoods MC-507 37 Kitchen Make-Up Air MC-508 39 Chimney Termination MC-Table 511.2 41 Air Plenums MC-602 47 Fire Esc Smoke Dampers MC-607.5.1 52 Combustion Air MC-701 55 Confined Spaces-Def. MC-202 5 Fan Shutdown/Alarm MC-606.2 50 System 32. Fuel Gas Code Appliance Location FGC-303 18 Combustion Air FGC-304 19 Clearance to Combust. FGC-Table 308.2 25 Pipe Material FGC-403 46 Shut Off Valves FGC-409 53 Chimney Termination FGC-Fig.503.5.4 63 Gas Vent Termination FGC-Fig.503.6.6 65 Exit Terminal Location FGC-503.8 68 Clothes Dryer Exhaust FGC-613 96 Unvented Room Heaters FGC-620 99 _.. - 33. Energy Code Prescriptive Method ECCC-Table 602.1(1) 50 High Truss Credit ECCC-602.1.2 51 Pipe Insulation-Heating ECCC-Table 503.3.3.1 44 ��, Duct Insulation-Heating ECCC-Table 503.3.3.3 45 Pipe Insulation Hot Water ECCC-Table 504.2 47 HWH Heat Trap ECCC-504.7 47 Comcheck Computer Software Compliance Report Re wired 34. Special Inspections BC 1704 379 �., 35. Sound Transmission BC 1206 251 =/j 36. Ice&Snow Shield Reg. 37. No Reinforcing in Footings Notes: Page 6 of 10 r LIST OF CALCULATIONS THAT MAY BE REQUIRED FOR A COMPLETE CODE REVIEW 1. Area Increase Based Upon Frontage And Sprinkler Increase. Frontage Increase: If=100(F/P-0.25)W =Answer in% 30 Note: If=75%when 4 sides accessible&z water available Allowable Area: A. =Atabte + (Aube x If) + (Atabke X IS)=Answer in Square Feet (BC-Pg.74) 100 100 2. Exit Capacity Calculation (Table 1003.2.3)(BC-Pg.202) (Occupancy Load for Exit) x(Egress Width per Occupant)=(Required Width) 3. Snow Loading Calculations. (ASCE 7-98)(Eq.7-1)(pg-69)&z(Eq. 7-2)(pg-70) (ASCE=American Society of Civil Engineers) Pf =0.7CeC,IPg=Flat Roof Snow Load Where: Pf=Flat Roof Snow Load (Calculated Above,Answer in#per SF) Ce=Exposure Factor (BC-Table 1608.3.1)(Pg.297) Ct =Thermal Factor (BC-Table 1608.3.2)(Pg.297) I = Importance Factor (BC-Table 1604.5)(Pg.287) Pg=Ground Snow Load (BC-Fig.1608.2)(Pg. 296) Ps =C,Pf=Sloped-Roof Snow Load Where: PS=Sloped-Roof Snow Load C$=Roof Slope Factor (ASCE 7-98)(Pg.70) 4. Wind loading calculations. (Refer to Chapter 6 of ASCE 7-98) 5. Seismic Calculations. (See page 10 of this list) 6. COMCheck calculations (For verification of compliance with the Energy Code) Page 7 of 10 8. GRADE PLANE: A reference plane representing the average of finished ground level adjoining the building at exterior walls. Where the finished ground level slopes away from the exterior walls,the reference plane shall be established by the lowest points within the area between the building and the lot line or,where the lot line is more than 6 feet from the building,between the building and a point 6 feet from the building. 9. MEZZANINE: An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than 1/3`d of the area of the room of space in which the level or levels are located. (Mezzanine area does not contribute to the building area or the height in stories but does contribute to the fire area,aggregate area). 10. SMOKE BARRIER: A continuous membrane,either vertical or horizontal,such as a wall,floor,or ceiling assembly,that is designed and constructed to restrict the movement of smoke. (Required to have a I hr.fire rating). 11. STORY ABOVE GRADE PLANE: Any story having its finished floor surface entirely above grade plane,except that a basement shall be considered as a story above grade plan where the finished surface of the floor above the basement is: 1. More than 6 feet above grade plane or 2. More than 6 feet above finished ground level for more than 50%of the total building perimeter or 3. More than 12 feet above the finished ground level at any point. Page 9 of 10 Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. 7 r Ll Town of Queensbury 742 Bay Road Queensbury,NY 12804 Scheduled Inspection Date: Phone: (518)761-8206 Business Name: U' Fax: (518)745-4437 Location. v i ll( 11 Two of Hon N/A Yea ft EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondar Aisle Width EXIT SIGNAGE Sign—normal Sign-battery OlLr EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING J J FIRE EXTINGUISHER: (� Hun Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sp rinkler S stem F)C Fire suppression—Witchen Fire Suppression—Gas Islan Generator Hood Installation Elevator Interior Finishes c— ~^°""" Storage Compressed Gas h �•� " 11 Clearance to Sprinklers 3 Clearance to Electrical Electric Wising Enclosed/Labeled 4 i `U, ` Combustible Waste Vehicle Impact Protection Knox Box F.D.Sign age—Utility Rooms No Smokina Signs vn Maximum Occupancy Si n Emergency Evacuation Plan "Approved (if no other approvals apply,the B&C Office vai 'suet C ficate of Occupancy) ❑ Denied / call for Recheck 0 Inspected By: L:\FreMarshal\New Folder\pem itto occupytorm.doc Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection.FgWt fecive Queensbury Building& Code Enforcement Arrive: ,�epart: a 742 Bay Road,Queensbury,NY 12804 Inspector's Initials,° j NAME: PERMIT: LOCATION: fti i, DATE: :- — 13 COMMENTS: - Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent 5,7 Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. ' Gas Valve Shut-off Exposed&Regulator 18" Above Grade r' Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors > 10%> 1000 s .ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed / Handicapped Bathroom Grab Bars/Sinks/Toilets �� ! Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" V Handicapped Ramp/Handrails Continuous!12 in.Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical 1' Site Plan/Variance required Final Survey,New.Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler -774 Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Tem . or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc kn-s Queensbury Building & Code Enforcement - Residential R I I pection Office No. (518) 761-8256 Arrive: a m e m m Date Inspection request received: Inspector's Initials: p,4// NAME: t R IT#: LOCATION: DA E: — TYPE OF STRUCTUR : Comments: Yes No NIA J � 4" Building Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location �� Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more F—% -V5"►36 VOb\\ lJ G KE Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall �- Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet �CTV NR,4E N� Pw 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight L bV,�VV-PC\&— LL \�� Safety glazing,/Window in stairwells safety glazing Interior Smoke Detectors/Carton Monoxide Detectors �© Every level: Every Bedroom: \ OD Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum IN Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pie Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required IA Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\lnspection FormsWesidential Final Inspection Forrn_revised_100405.doc;Revised January 7,2008;Revised 626/08 Commercial Final Inspection Report U j Z ice No.: (518),761-8256 Date Inspection re ue ec ' d: C� 1 Queensbury Building&Code Enforcement Arrive: Depart: �1< 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s. NAME: �U(.>rM � GU&e4 t S h1rX PERMIT 0 7 — LOCATION: �' eve tl l �' . DATE: 11 COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18")Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut_ Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Hand hroom Grab Bars/Sinks/Toilets 11indicapped Batki Parking Lot Si na e oom Handica essible Handicapped Service Counte , 34 in. heeko Handicapped Ramp/Handrails Con muous, 2 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Coolers Building Access All Sides by 20' /Driveable Surface 20'wide > Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc t_ Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection tbeQueensbury Building& Code Enforcement Arrive: part: m 742 Bay Road,Queensbury,NY 12804 Inspector's Inrt NAME: _ PE I 7" LOCATION: DA . COMMENTS: Chimney/"B"Vent/Direct Vent Location Y N NA Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade \ Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 s .ft. 3/o Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed 'N-L� 11101L TZ{!P,� Handicapped Ba Grab Bars/Sinks/Toilets 1 rj,6TAq Handica ath/ 'ng Lot Si na a , i Public Toi Handica ed Accessible \ Ak Handicapped Service Counters, 34 in.,Checkout 36" i Handicapped Ramp/Handrails Continuous/12 in.Beyond]B , `koth sides] �— 1� Lt1 Active Listening System and Signage Assembly Space ? � oJE � Final Electrical � Site Plan/Variance required . t t%u Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System La out Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C LABuilding&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Inspection for Permit to Occupy fire (.1�� M�"SI1�'i office Request Rec'd Permit No, L i�.,.,. Town of Queensbury 3 742 Bay Road Queensbury,NY 12804 Scheduled Inspection Date: _ �_. Time: _.- Phone: (518)761-8206 Business Name: Fax: (518)745-4437 Location: T of N A Yes No EXITS: Exit Access COMMENTS Exit Enclosure 0001 ExitDischarge �I1 (3 m4f,6� l AISLES: C CTYW 6<--� C Main Aisle Width Secondgr y Aisle Width Q chno -� EXIT SIGNAGE Si -normal \ ,� ' T rt.s SS Sign-batter 1 EVAC signs in rooms TRUSS ID SIGNAGE 70C EMERGENCY LIGHTING AL$JL f FIRE WINGUISHER: Hun _ inspection of extin Sher C) J c> FIRE ALARM SYSTEM h�v C a-1w.) c Fan Shutdown Fire S kler System fire S resslon-kitchen CIF. Fire SM2resslon-Gas Islan Generator ` l �` i-�-rd,,*,6 gsSL Hood Installation � Elevator Interior Finishes Story e Compressed Gas Clearance to Scorinklers Clearance to Electrical Electric Whing Enclosed/labeled Combustible Waste vehicle impact Protection Knox Box F.D.Si na e-MY Rooms No Smoking Signs Maximum Qcc anc Si Emergency Evacuation Plan O Approved (If no other approvals apply,the B&C Office win issue the ific e o ccupancy) rail 1 call for Recheck Inspected By: L-\FheMarshai\New Folder\permitto occupyform.doc 1L)��-- Rough Plumbing / Insulation Inspectioti Report Office No. (518) 761-8256 Date Inspection requ, reqeiv r, r� , Queensbury Building &Code Enforcement Arrive: ', - am part: E71 _ 8 an)/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Ini NAME: G 0L) PERMIt #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent cr-��-��� Air/ Head vo3b 5 P.S.I. or 10 ft. above highest connection for 15 minutes t t� Pressure Test Water Supply Piping ead 50 P.S. for 15 minutes nsulation Residential Check Commercial Check o er Vet Attic Vent Du Water Piping Insulation If re ulred unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection r ues rec v Queensbury Building&Code Enforcement Arrive: p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: JI - PERMIT#: — LOCATION: t INSPECT ON: j TYPE OF STRUCTURE: Framing Y N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ectio e s ive Queensbury Building&Code Enforcement Arrive: rt: Z-- am/ m 742 Bay Road, Queensbury,NY 12804 Inspector's Initi s: ��— NAME: �� 1w�J�� PERMIT#: LOCATION: \ \U-rc 9 — INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENT Framin Attic Access 22"x 30"minimum Jack Studs/Headers Bracin /Bridging �-- oist angers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. F► 5� R��,�� Headroom 6 ft. 8 in. Stairwells 36 in. or more � 7 Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls i Metal Strapping for Notches Top Plate I 1 %z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ! p Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour 7i Fire wall 2, 3,4 hour irestoppin enetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade (bei; -- /� Framing Firestopping Inspection Repo ;/ Office No. (518) 761-8256 Date:inspection requ eive Queensbury Building&Code Enforcement Arrive: �a p D a � am/Am 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: P`� /1 , 1/�l /l�.. £� PERMIT#: 07— W--� LOCATION: s INSPECT ON: — u—U TYPE OF STRUCTURE: Y N /A COMMENTS Framing 5� A0- ttic ess 22"x 30"minimum `� '�(�17 t7 k C_\7*,".) Jack Studs/Headers (? �C -E:N l] Bracing/Bridging '( Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly " _ Headroom ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. 16t� 6/' Notches/Holes/Bearing Walls f Metal Strapping for Notches Top Plate 1 `/s w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Septic Inspection Report Office No.(518) 761-8256 Date Inspectiorequest received: Queensbury Building&Code Enforcement Arrive: 2l fo am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: e c l PERMIT NO.: (37' t/ 3 LOCATION: , / INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/Loam!Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: $, Absorption Field: Total length ft. -Length of each trench ft. _Dqpth of trenches $. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N / Y Engineer Report and As-Built Y Ni— �� Q Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use St s• Approved Partial Approved and needs to be re-inspected,please call the Building& Codes Office Disapproved Last revised 1/6/05 -30 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date ins ction re es c iv S Queensbury Building&Code Enforcement Arrive: O art: a pm 742 Bay Road,Queensbury,NY 12804 Inspecto s Initi s. " NAME: okC PERMIT#: G LOCATION: L n' ,1 t INSPECT ON: �� TYPE OF STRUCTURE: raming Y N N/A COMMENTS v` Attic Access 22"x 30"minimum / Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams �-- � Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / FirestoPPing Inspection Report 1 Office No. (518) 761-8256 Date'In71nitia e re iv Queensbury Building&Code Enforcement Arriv": m rt: `m/ 742 Bay Road,Queensbury,NY 12804 Inspect NAME: �,;,� y� ��f 1 (L _ _ PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 �/s w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses c or less on center Ice and water shie 24 inches from wall _Tli ion 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X i Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Y Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection req _ Queensbury Building &Code Enforcement Arrive: = �' 742 Bay Road, Queensbury, NY 12804 Inspector's Init s. NAME: j4ztvull� Pct4 PERM #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y IN N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pr T st—� D nt Ai P.S. . aboveV, hi hest connection for 15 minutes re Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: ;?6 am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: - - NAME: �4 r PERMIT #: CI— LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping A' d 0 P.S.I ' r 15 minutes Insu Ftion Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If re uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whitinouilding&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 ao kk4l��daj to Septic Inspection Report Office No. (518) 761-8256 Date Ins request received: Queensbury Building&Code Enforcement Arrive: t am/ Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT NO.: 12z r4/3, LOCATION: S INSPECT ON: RECHECK: Comments and/or diagram Sail T : Sand Loa CI Type of Water: urnci I ell Wa Waterline separation distance ft. Well separation distance `7 2Q0 ft. Other wells: ft. -Absorption Field: Total leng1t ft. Length of each trench ft. Depth of trenches 2 ft. Size of Stone .Seepage Pits: Number Size: x Stone Size: Piping Size Type Building W tank u Tank to Distribution Box Distribution Box tiFleld Pit I'll I O ning Sealed N Partial End Ca �y Inle Outset Pipes&Baffles Y N rf ATIZI �el' Location/ Se rations � S pe� IQ�ln, IA. Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N , � /,n et, �< ell Location of System on Property: Front Rear "�$ Right Side Middle Front Middle Rear Lee,4 7 /V � System Use Status: S c � � ��� e s � � RJ ��I L7• /� Approved �i�� Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 Foundation Inspection Report Office No.(518)761-8256 Date Inspectio es eceiv Queensbury Building&Code Enforcement Arrive: b� part: am/ 742 Bay Rd.,Queensbury,NY 12804 Inspector's i 7 NAME: 11 � PERMIT#: LOCATION: 1 I FL INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings • � 4t Monolithic Sla Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: 'am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: C-11 NAME: c� QLre` )-iS L4' PERMIT #: 0' LOCATION: r INSPECT ON: TYPE OF STRUCTURE: YL N/A M-Rough Plumbing Nail Plates ! t)06- Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct to e PVC- COMMENTS: LAPam Whitinouilding&CodeAnspection FormslRough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 1 S,2005 Foundation Inspection Report Office No.(518)761-8256 Date Inspection quest received: Queensbury Building&Code Enforcement Arrive: . P Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: I 6 U PERMIT#: 0 7-zl 3 LOCATION: 2wj i INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab Foundation In tion ri /Exterior Rough Grade 6 mch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518)761-8256 Date Inspection st r 7 7 Queensbury Building&Code Enforcement Arrive: r pm Depart: - 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi s: v NA> P T#: /v bt 0 7 LOCATION: 4 SPECT ON: ` IA?f2 7-17 —O TYPE OF STRUCTURE: Comments 7A �" r ID Y N NIA I� Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM .� 0? -Z/4 F TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 5 18-761-8201 July 17, 2007 Ethan Hall Rucinski Hall Architects 627 Maple Avenue Saratoga Springs, NY 12866 Dear Ethan: The following items need to be addressed on the plans for the new recreation center building at Jenkinsville Park. 1. Truss ID signage needs to be provided at all entrance doors to the structure. 2. There is currently no attic access shown on the plans. Please provide appropriate attic access. 3. We need all structural loads, calculations for seismic, wind, and snow load. 4. The handicap toilet grab bars are not shown for the appropriate widths on side and rear. 5. There is no sink wrap shown on the plans for the handicap sink. 6. There is no height for the urinals shown above finished floor. 7. Under the Energy Code, the top of the foundation insulation is required to have a 45 degree angle cut. Please change the detail accordingly. 8. The ice and snow shield is shown on the plans two feet from the exterior of the outside walls instead of the interior of the outside walls for the 24 inch dimension. Please correct. 9. Change all emergency lights to a combination of emergency exit lights over all doors leading to the exterior of the building. Once the above issues have been addressed on the plans, this Department can issue a permit for the project. "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763 If you have any questions, please don't hesitate to contact me. Sincerely, TOWN OF QUEENSBURY j° David Hatin, Director Building and Code Enforcement D H/mg ui/11/2007 TUE 11:11 FAX 5187454437 Community Development 12001 *** FAX TX REPORT *** ********************* TRANSMISSION OK JOB NO. 1528 DESTINATION ADDRESS 95845012 PSWD/SUBADDRESS DESTINATION ID ST. TIME 07/17 11:10 USAGE T 00, 58 PGS. 2 RESULT OK TOWN OF QUEENSBURY 742 Say Road. Queensbury, NY 12804-5002 S 18-761.8201 i July 17, 2007 i Ethan Hall Rucinski Hall Architects 627 Maple Avenue Saratoga Springs, NY 12866 Dear Ethan: The following Items need to be addressed on the plans for the new recreation center building at Jenkinsville Park, 1. Truss I©signage needs to be provided at all entrance doors to the structure. 2. There Is currently no attic access shown on the plans. Please provide appropriate attic access. 3. We need all structural loads, calculations for seismic,wind, and snow load. 4. The handicap toilet grab bars are not shown for the appropriate widths on side and rear. 5. There is no sink wrap shown on the plans for the handicap sink. 6. There is no height for the urinals shown above finished floor. 7. Under the Energy Code, the top of the foundation insulation Is required to have a 45 degree angle cut. Please change the detail accordingly. 8. The ice and snow shield is shown on the plans two feet from the exterior of the outside wells Instead of the interior of the outside walls for the 24 inch dimension. Please correct. 9. Change all emergency lights to a combination of emergency exit lights over all doors leading to the exterior of the building. Once the above Issues have been addressed on the plans, this Department can issue a hermit for the oroiect. RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall C 627 Maple Avenue Saratoga Springs NY 12866 Voice 518 580 1905 Fax 518 584 5012 Email ronrr@nycap.rr.com ephall@nycap.rr.com Transmittal To: David Hatin—Code Enforcement Officer—Town of Queensbury From: Ethan Hall Date: 20 July, 2007 Re: Jenkinsville Field —Recreation Department Concessions Facility In response to your fax of 17 July 2007 we offer the following responses; • Truss ID signage has been added to the revised drawings • Attic access panel has been added to the revised drawings • Structural calculations are enclosed • Grab bar lengths have been indicated • Knee protection is indicated on the toilet room elevation details • Urinal height has been added to the toilet room elevation detail • Foundation wall 45 degree angle cut has been added • Ice &water shield has been revised on the drawings • Emergency lights have been changed to combination exit & emergency light fixtures and have been relocated to be above all exterior doors. I believe this addresses all items indicated on your fax. If there are additional questions please give me a call to discuss. Regards, Ethan P. Hall Architect CAAC"Queensbury Rec.DeptUenkinsville fieldhouseTaperworkUransminal 20 July 2007.doc RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski D [E C E Ethan Peter Hall 627 Maple Avenue SEP 13 2007 Saratoga Springs NY 12866 TOWN OF QUEENSBURY Voice 518 580 1905 BUILDING >' CODES Fax 518 584 5012 Email ronrr@nycap.rr.com ephall@nycap.rr.com Letter of Special Inspections To: John O'Brien—Code Enforcement Officer—Town of Queensbury From: Ethan Hall Date: 12 September, 2007 - - Re: Jenkinsville Field—Recreation Department Concessions Facility Per our conversation on 11 September I visited the site for the above referenced project. Based on my site visit it appears that all items have been installed in accordance with the construction drawings and conversations between myself and Pinchook & Buckley Construction and all installations to this point are acceptable to this office. If there are additional questions please give me a call to discuss. A e Regar s, r I d +�F 4 Ethan P. Half r Architect CAACAD\Queensbury Rec.DeptUenkinsville fieldhouseTaperworiASpecial Inspection Letter 12 Sept 2007.doc 1 o- .y r a SE COMM .. „G �.. yam: f � ..�� �,.. �, .� ..:. . .�. � .' y ± �," ,.,.:, r� e ., �_,. _ . _ _ riv ,. _ >}�; �:' �,� �_ �. -� ., . . _ —.�.u, a„ _ . _ ,� __ �tI��°,��t4U�� y; for SY cars o-f= 41 .01 } 4 , 4 • _ c Z `4 lot" t �L_ �—�_ �� � ' _.�. ��. �� �__� � � v .: �- ,�y •-:.v f .. a ... is yet _�'F�I l�i'�, YR _4�--�.��"_ �I, «_T„ t � __mow Z� � "� ,�,. x �. �� w e -.�., x, .w. 'tea �k p ��t'�1�'F° g � --�'"""wue"'� _ �, � �; _. F, a , :�_ Y. __�.�_€�