Loading...
2007-458 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070458 Application Number: A20070458 Tax Map No: 523400-308-019-0002-003-000-0000 Permission is hereby granted to: MICHAELS GROUP LLC, THE For property located at: 12 ESSEX Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP LLC, THE 10 BLACKSMITH Dr Suite 1 Fireplace MALTA, NY 12020-0000 Garage-2 Cars Attached Single Family Dwelling $204,000.00 Total Value $204,000.00 Contractor or Builder's Name / Address Electrical Inspection Agency Plans&Specifications 2007-458 2751 SQ FT SINGLE FAMILY DWELLING WITH 596 SQ FT GARAGE & 1 FIREPLACE $389.72 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,August 07, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Irueen ry; ues 07, 2007 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement 07- ��- ---------------------10 "T007U nity Development`Office Queensbury - 742 Bay Road - Queensbury, New York -12804 Date Stamp Marilyn Ryba,Executive Director-David Hatin,Director of Building&Codes ; ; Craig Brown,Zoning Administrator-Michael J.Palmer,Fire Marshal ', - ; , APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building &Use Permit pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED OWNER: 1 E M�C3-{A�E�_ _,L�_ SfZ�,`Q INSTALLER/BUILDER: ADDRESS: Ln ?=X.t'+fe-1�SI.11T1-{ _bZ. rrl1��'{A ADDRESS: PHONE NOS. PHONE NOS. LOCATION OF PROPERTY: lZ 7C L.Irur_r SUBDIVISION AMNAME: C^� LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: SZ 01 K'©C"CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:. \-z CIO PHONE: 3 2551- Air it- STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: M-b_-SDI C- MODEL NO. 'U 5bO LISTED BY: NUMBER: QUESTIONS? CALL 761-8205 or 761-8206 OR EMAIL: firemarshalCa gueensbury.net MASONRY** CHECK ONE ✓ VISIT OUR WEBSITE s FOR MORE INFORMATION =�,v ,. WN www.gueensbury-net FLUE CHECK ONE ✓ 777 TnY ` CHIMNEY MATERIAL CHECKONE ✓ x **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR j MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. i i Check Residential Plan Review: One& Two Family Dwellings N/N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Wbere Required Ice and Snow shield 24"Inside Exterior Watt/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width .Stair Run and Rise index Run and Rise Spiral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped ttic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level . ^yi 0 Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed • ............. r.------r... • , .... r..r �w................rr..� OFFICE USE ONLY ' 0 + TAX MAP NO. PERMIT NO. .. 7 kRMIT FEE ' i + ' + APPROVALS: ZONING TOWN CLERK- ------------------ , APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMITi A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: �IC44P,E5-S C� � INSTALLER: ADDRESS: 10 G - � i ADDRESS: �-� PHONE NOS. ��1q '��—'` PHONE NOS. LOCATION OF INSTALLATION: 1- �tsG�C Cculn - SLyrrot.� I�LP i RESIDENCE INFORMATION: YEAR BUILT' »..NO•.. F.•»•» ~X»� COMPUTATION= » 1 :TOTAL DAILY FLOW~».......I _ BEDROOMS GARBAGE GRINDER 1980 or older. »..».».»»»»..».....»»..... .»X. .....150 gallon per bedroom..... ... .. . ..........................._...........»................ i INSTALLED? ...... ..... 1981.»1.... ................».............. ..X. ....130 gallon per bedroom»»#. __..»...»..»..._.....»..•.••...•......_•m........................; SPA OR HOT TUB ..............r..........».„.»...•...».................•..................................».....• ...........»..»...».........•..».....•..........»•».............d.».......•...........,........................•....... 1 1992•present X 110 gallon per bedroom i »# ............ INSTALLED? »»»»»»........»...............». •».....,..............»•......................r....................................................I.......»...»..». a......... PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE ✓ S01L NATURE: SAND x LOAM CLAY OTHER ✓ CQR,OUNDWATER: AT WHAT DEPTH? BEDROCKf1MPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL-,X— WELL (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. 1 ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK: ov o GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH S FT. ✓ TOTAL SYSTEM LENGTH: I S bb FT. SEEPAGE PIT{S1: HOW MANY? ✓ SIZE OF EACH_FT. X FT. ✓ SIZE OF STONE TO BE USED: # 2— I DEPTH OR THICKNESSL—JL—FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: _ _ _ LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM:(if required) NO. OF TANKS: I SIZE OF EACH ✓ GALLONS./TOTAL CAPACITY: GAL. .•.•Y{•.x4.1.1•.wN.•V1•YNNYNNYi.{•H3•Y34.1.1.1.1•i•i••.1.14.1.1.••.x•.•in+...x•.•N...•f•.•.•ivf•{•.•1•.•+•3.1.1•yNl•..1.V•{'Ix4.14xxxx»x•N+•{x•YY....•1•.•....1•.'...x•....•...•.•.•3•.•Y.•uNlx•3•Yl•3•...•:4..•.•.....•.•N....3•.•..i.fr.•1•..:•....."W........... •3•VN••1•N.•.•YYY..W..•.•3 I NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN '! APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. 'I I r .4•NIx•YI•.xx4•Ix44x.Yi4.YIrl•.•..3•.4•.•{•..1•.•..Y.•{x•1•Ixx•i•1•i4•i•.4x4•:•i•N:4•Yt•Ix•.•1.3 V•ix•V.x•.•1•.•i•t•Ni•i•:•N.••44•i•{4.3x•F:•i•YI.14•Nf•Nl•Yf•1•.•:•.'Y.4.14•.4•Nt444rix•V Y14..»•:...:.....3..•e•+•�•:•i.:.•.Y••»44•Y.•{.{x.Y..NNl.t4.14...i44x•14xx'1•NN.•+4.1•+•1•)� For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by:or on behalf of an applicant, shall be void I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL n j56 EMAIL Queensbury Sanitary Se ge Disposal Ordinance. godes�laueen3burburvnet VISIT OUR WEBSITE FOR MORE,INFORMATION www:auegns burv.net Signatur IrPerson Responsible Date Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 ....�...a....a..................... ................w... ...... . �.. .. � R+r::........�' � OFFICE USE ONLY - ; ` TAXMAP f0. PERMIT NO, FEES: PERMITi RECREATION ENGINEERING , _ �� (If applicable) , :......................... .._......I.......-------......� .................... PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANTIBUILDER: -THE M%CWA:15-S�J750,A'" OWNER: ADDRESS: 0rSM►11t �Tz, - Y ADDRESS: ' PHONE NOS. ��G 3ti PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:T- Lo C,A:-cio PHONE: be)-7 314 4 LOCATION OF PROPERTY: - C—zr-� cc>uz-T SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p d d w APPLY TO YOUR z0 i-- M O cn w PROJECT F- ad O w a X v 0 z a a 19co Minn oU- Clad SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS_ i TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(103) 1� 5� OTHER IF COMMERCIAL OR INDUSTRIAL--NAME OF B'UIINNC SS: ESTIMATED CONSTRUCTION COST: 2O 4+C>ZmD FUEL TYPE: C►A-s HEAT TYPE: Flo A` "HOW MANY FIREPLACES): AND/OR WOODS�T)OVES(S): '- ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?IS THIS A HISTORIC SITE? AID PROPOSED USE OF BUILDING OR ADDITION: *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 AIM Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 v .....:.....................OFFICE USE ONLY -----...............----- i %............----.. 1. TAX MAP NO. PERMIT NO. ; FEES: PERMIT RECREATION ENGINEERING ' (If applicable) o ; ...................................................................... i...........,......... PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: OWNER: ADDRESS: ADDRESS: PHONE NOS. PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z p O Lou PROJECT o w O tLL _ a. U w o d ° C1 I— OI— w z ¢ a CO N to O LL a x xs SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS!) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: FUEL TYPE: HEAT TYPE: "HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL i 1-OS a Town of Queensbury- Community Development Office - 742 Bay Road, Queensbury, NY 12804 r ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to t ab Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the ; described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING &CODES APPROVAL ZONING APPROVAL DATE DATE , , i 4UESTIONS? CALL 761-8256 OR EMAIL codes0gueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION WWW.aueensbury.net y`< Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p epart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: ,,YP% NAME: V PERMIT NO.: LOCATION: 2 INSPECT ON: Zt v RECHECK: Comments and/or diagram Soil Type: Sand Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: Y N End Cap Y N Inlet/Outlet Pipes &Baffles Y N L 60A) Location Separations Foundation to tank Foundation to absorption Z ft. Separation of Pits ft. Conforms as per Plot Plan N Engineer Report and As-Built Y N Location of System on Prop rty: Front Rear Left Side Right Side Middle Front Middle Rear SyAem Use t Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: _ //�l(•bJ �� i' LOCATION: PERMIT#: Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the survey CraWroWh,Zoning Administrator Notes: L:1SueHemingway\Buildmg.Codes.Inspection.FORMS\Final Survey Zoning Administrator_doc MAP REFERENCE: M0)jjr X SUTTON PLACE SUBDIVISION DATED SEPTEMBER4 23, 2003 LAST REVISED MARCH 20, 2006 BY VAN DUSEN & STEVES LAND SURVEYORS A O 06� COURT L. �� .°° ESSEX a- E"4 11--�� o o H�y O I PpRGN S TORI 24. *0014D�� LOT D 4 Q N 9 1000 GAL. 11 N LOT N 5EPTIC TANK Cb CA 2 C! O O N N , 55.0' w 26, OEM N m D15TRI13UTION BOX sg G A1350RPTION TRENCHES I 3Q49' LOT I 3 21,397 sq. ft. 0.49 acres THOMAS R. CUT ZONE CENTER,JR. 92.98 N77�g6 38 wE =rr $2.1 r\. SEPTIC SYSTEM - AS - BUILT BY NACE ENGINEERING , P . C . a e� February , Du ,� 'IMA{AJM A<D AL7El LA 9,W,M TO NNaET A Map of a Survey made for Scale 1'=30' & e,n M NENNON A MOM LAM R�,�� MAIM OF NEc1NM r�o Nu�awsa s,ar'RE "YM STALE pMMATM LAW S t e v e s 'ONLY WW QN A Cr IM �7FNN VE"M MNL r11N AN O1N0NIN.OF 7!C LAND SUIYEIdIi S_ 1 . �N�E M BE VALN)AO=M= IM Danny E. & Carman L. Howe "CE WnFr 1TM M M=IM NF7 M M@EY 7NAT 7NNi 9NlYEY NMS PIEPAREO N AOCOININlCE w1N if! Land Surveyors V IM" 0 STAN R"`" WPOMMM N`�° BY TiE NENi Y7NN STATE A89ODA1NM�PNOFE7NNONAL LAW SIINVEIm SAD cuawl"7M owu NUN OILY m IM Mn Fat*M 1W"M M NWAMM" M M New M 7NE lme CWNW.OOVE70Smax � 169 HavUand Road Queensbury, New York 12804 7W OF� "° Town of Queensbury, Warren County, New York 0 2/17/08 SEPTIC SYSTEM AS—BUILT HOWE (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 05197—LOT 3 z%. 7Z,-s� . Queensbury Building & Code Enforcement - Residential Final InspectionOffi DateInspection) �pm Depart: am/pm request Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Y o MIA ,V Building Number Address visible from road Chimney Height/'B"Vent/Direct Vent Location V,Fresh Air Intake f 3 inch Plumbing Vent thr h roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railkys 34 inches to 38 inches Deck Brad / Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill PWW Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim I doors I main entrance 36 inches Bathroom/Krthen watertight Safety glazm I Window in sta"wetis safety g§—zkN Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Baftery backup: Attic access 30 inches x 22 inches x 30 inches in acoessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft Effwgency egress below grade IT k Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Fumace/Fiot Water Heater operaft Low water shut-off boiler Relief Va s installed I Heat Trap/Water Te 110 Enclosed Stairs Sheetrock Underside minimum W G m Basement stairs dosed rise>4 inches f GaMe Floor Pkhed v Garage fireproofing/%hour fire door/door doser Duct work Sealed Properly Gas Logs in Sealed orGWAskgMMre Final Ekx*ical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept.Ins lion Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes FormslBuifding&Codes\lnspec don Forms\Residential Final inspection Form revised_100405.doc,Revised January 7,2008 c Z7., Foundation Inspection Report Office No.(518)761-8256 Date Inspectljgn request received: Queensbury Building&Code Enforcement Arrive:i am/pip Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: l/ NAME: 1 91-(-�1 Cx-e �" � PERMIT LOCATION: INSPECT ON: -& TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing areas under slab ackfill Approval- Plumbing Under Slab opper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r uest received: Queensbury Building &Code Enforcement Arrive: I 0 • am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Ins is Initials: NAME: �' c l '�-� PERMIT #: 07 LOCATION: G—h�j INSPECT ON: -�Z— TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum eanout every 100 feet change of direction Pressure Test Drain Air/Ueal5 P.Sft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No.(518)761-8256 Date Inspection r st received: Queensbury Building&Code Enforcement Arrive: pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: /", PERMIT#: LOCATION: / INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Foo Piers i is Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fors\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM a�- /�� Septic Inspection Report Office No. (518)761-8256 Date InV Queensbury Building&Code Enforcement Arrive: rt: = L742 Bay Rd., Queensbury, NY 12804 InspectoNAME: `LOCATION: RECHECK: Comments and/or diagram Sal T : nd 69§PV Clay Type of Water; unicipaP Well Water Waterline separation distance ' ft• Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench t. Depth of trenches - ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank H11 Tank to Distribution Box +' Distribution Box Id Pit " F, Opening Sea : Y I End Ca Inlet/Outlet Pipes&Baffles N Location/ Separations rc fZ Foundation to tank ft. LP Aa.)SE Foundation to absombon ft. Se `,+ t n ineer Report and As-Built Y N D 11 Location of System on Property: Front Rear Left Side -_-- Middle Front Middle Rear VJEVV T 1\6— DQ(L1 System Use Stags:. Io illLL 66CF F►.� V3C&Q_% proved , p needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspecti n request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials�i2-` ' NAME: fvti' _ - PERMIT #: LOCATION: INSPECT ON: /f TYPE OF STRUCTURE: Y N NIA Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Testy if C Water Supply Piping Air/ Head r 15 minutes (-Prapec-Ver�,In ulation Residential Check Commercial Check Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection For ns\Rough Plumbing Insulation Report-revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No.(518)761-8256 Date Inspection west received: Queensbury Building&Code Enforcement Arrive: ; 2 pp Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials. Z_ NAME: r.LiJ PERMIT#: a7 LOCATION: , �C— "'Jo w INSPECT ON: I t 0 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. F dation/Wallpour einforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received b 7 Queensbury Building & Code Enforcement Arrive: am/ epart: m/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: p",� NAME: rl al / e,( S &C"P PERMIT #: 0 LOCATION: I SS e- Cv✓f-r INSPECT ON: TYPE OF STRUCTURE: Y 1JN N/A -Rough Plumbing Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report 1) Office No.(518) 761-8256 Date Inspectio equest received: V Queensbury Building&Code Enforcement Arrive.,,,, ` am/ Depart: a pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: tiC NAME: l� C U) 61 ro✓- PERMIT#: 07' LOCATION: - S INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing ' Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. i Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Town of Queenibury Fire Marshal 4DW 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Renort Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is alloyed. Permit# `C�s Schedule Inspection r L- C'7Time �L am pm anytime r C-4 S 6-0 2 f- S G UU/ F Name �"1 P� Address � f Rough In Final Appliance Manufacturer�6 S4-t� Model Direct Vent Factory Built Chimney Atue Size Double Wall____ Triple Wall Insulated Yes :No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White-HWidin=Dept. Yellow r Pink-Fin Marshal / S� P- Rough Plumbing J Insulation Inspection Report Office No. (518) 761-8256 Date Inspection uest received: �. 007 Queensbury Building & Code Enforcement Arrive. �am/n art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: X�' NAME: 9-d4JPERMIT #: c;�)X7 S� LOCATION: l INSPECT ON: owl TYPE OF STRUCTURE: Y N N/A Rauch Plumb! ail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction fS re Test / Vent Head .I. or 10 ft. above highest connection for 15 minutes ressure Test er Supply Piping /SF) Head .S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct-tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ctio quest received: Queensbury Building&Code Enforcement Arrive: m/p a am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's)Initials: NAME: ti t�. PERMIT#: ✓�� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour I' i Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:/tAn ' NAME: PERMIT#: L1/-T 45(�� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z w) 16 gauge(8) 16D nails eac e D ft ing 1,000 sq. ft. fl sses chor olts ft. or lesse6k6enter Ice and water sOield,24 inches from all Fire se on 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade rye Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection';equest received: Queensbury Building&Code Enforcement Arrive._ 1. 1 am/pm Dep am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's—Initials:� R . NAME: ( - PERMIT#: LOCATION: INSPECT ON: / TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 361. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge(8) 16D nails each side Draft sto 1,000 sq. ft. floor trusses -Agelhoir-Rolts 6 ft,or ess on center p 1 Ice and water shield 4 inches from wall � l+ Fir on 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed I 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: �1�� Queensbury Building&Code Enforcement Arrive: am/pm Depart: A� am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: I "l,l PERMIT#: 4�s LOCATION: INSPECT ON: TYPE OF STRUC Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Ins tion request received: Queensbury Building&Code Enforcement Arrive. ' am/pm Departix-/am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect s tials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour �4 Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footin in Daylight or Sump Footing Drain Stone: 12 me above footing 6 mil po for wet areas under slab Backfill roval 111�mg Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection,�uest received: Queensbury Building&Code Enforcement Arrive: :�am/pm� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: .,_ NAME: q . rj PERMIT#: D LOCATION: INSPECT ON: 5 TYPE OF STRUCTURE: Comments Y N NIA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspec:ion Forms\Foundation Inspection Report doc Last printed 12/20/2005 9:24:00 AM 2 Foundation Inspection Report Office No.(518)761-8256 Date Inspectlqn request received: Queensbury Building&Code Enforcement Arrive: am/pn Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's itials: NAME: ;r 4 1< PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUC �e Comments Y N NIA Footings ���(1 Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM S Permit# Permit Date NotREScheck Software Version 3.7.3 Compliance Certificate C)F Re Project Title: The Devonshire �P ��\A D RvA O Report Date:07/16/07 *co Data filename: F:\SHARE\Design\Res-Check\Sutton Place\12 Essex Court.rck b er Energy Code: New York State Energy Conservation n _ w Construction Code 2 Location: Warren County, New York Construction Type: Detached 1 or 2 Family ,p 6668 '3 Heating Type: Non-Electric O Glazing Area Percentage: 16% " S ION Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/ ontra or: 12 Essex Court(Lot#3) The Michaels Group Queensbury,NY 10 Blacksmith Drive Permit Date:July 16,2007 Malta,NY 899-6311 • • Your . .• - __ I=N �.. Ceiling 1:Raised or Energy Truss: 1896 30.0 0.0 61 First Floor Walls:Wood Frame, 16"o.c.: 1728 19.0 0.0 82 1x Home Office(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Mud#20:Solid: 19 0.240 5 1x Master Bath(Y):Wood Frame,Double Pane with Low-E: 16 0.340 5 1x Master Suite(AG):Wood Frame,Double Pane with Low-E: 9 0.340 3 1x Master Suite(AO):Wood Frame,Double Pane with Low-E: 35 0.340 12 2x Great Room(Y):Wood Frame,Double Pane with Low-E: 31 0.340 11 2x Great Room(AA):Wood Frame,Double Pane with Low-E: 13 0.340 4 2x Great Room(AR):Wood Frame,Double Pane with Low-E: 31 0.340 11 1x Great Room(AL):Wood Frame,Double Pane with Low-E: 25 0.340 9 1x Great Room(AK):Wood Frame,Double Pane with Low-E: 11 0.340 4 1x Great Room(AQ):Wood Frame,Double Pane with Low-E: 27 0.340 9 Brkfst#17:Glass: 54 0.350 19 1x Dining(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Foyer#1:Glass: 21 0.350 7 2nd Story Walls:Wood Frame, 16"o.c.: 1184 19.0 0.0 63 1x Foyer(AP):Wood Frame,Double Pane with Low-E: 11 0.340 4 1x Bed#3(AB):Wood Frame,Double Pane with Law-E: 31 0.340 11 1x Loft(AB):Wood Frame,Double Pane with Low-E: 31 0,340 11 2x Loft(Y):Wood Frame,Double Pane with Low-E: 31 0.340 11 1x Bed#2(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Bsmnt Wall 1:Solid Concrete or Masonry: 1480 0.0 11.0 94 3x Std Bsmt Wins:Wood Frame,Double Pane with Low-E: 10 0.520 5 2868 Stl Door:Solid: 19 0.240 5 Furnace 1:Forced Hot Air:92 AFUE The Devonshire Page 1 of 6 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requir ments.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best is/her kn wledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. 7-17-0 esigner Company Name Date Proje Note Pell Prolin indows The Devonshire Page 2 of 6 Cj( REScheck Software Version 3.7.3 Inspection Checklist Date: 07/16/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ First Floor Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: ❑ 2nd Story Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Bsmnt Wall 1:Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Windows: ❑ 1x Home Office(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Bath(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Suite(AG):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Suite(AO):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(AA):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AL):Wood Frame,Double Pane with Low-E,U-factor:0.340 The Devonshire Page 3 of 6 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AK):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AQ):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Dining(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Foyer(AP):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Bed#3(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Loft(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Loft(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Bed#2(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3x Std Bsmt Wins:Wood Frame,Double Pane with Low-E,U-factor:0.520 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Mud#20:Solid,U-factor:0.240 Comments: ❑ Brkfst#17:Glass,U-factor:0.350 Comments: ❑ Foyer#1:Glass,U-factor:0.350 Comments: ❑ 2868 Stl Door:Solid,U-factor:0.240 Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:92 AFUE or higher Make and Model Number: Air Leakage: The Devonshire Page 4 of 6 ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. The Devonshire Page 5 of 6 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) The Devonshire Page 6 of 6 Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate .�e0E- w Project Title: The Devonshire .�P �I H D ,, � � Jo O Report Date: 07/16/07 # .�- F,9�'per Data filename: F:\SHARE\Design\Res-Check\Sutton Place\12 Essex Court.rck Energy Code: New York State Energy Conservation m W Construction Code Z v Location: Warren County, New York Construction Type: Detached 1 or 2 Family �o �6684 Heating Type: Non-Electric 9 Glazing Area Percentage: 16% FESS NPR Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/ ontra r: 12 Essex Court(Lot#3) The Michaels Group Queensbury,NY 10 Blacksmith Drive Permit Date:July 16,2007 Malta,NY 899-6311 Compliance: . . .. Cavity Cont • �.. Ceiling 1:Raised or Energy Truss: 1896 30.0 0.0 61 First Floor Walls:Wood Frame, 16"o.c.: 1728 19.0 0.0 82 1x Home Office(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Mud#20:Solid: 19 0.240 5 1x Master Bath(Y):Wood Frame,Double Pane with Low-E: 16 0.340 5 1x Master Suite(AG):Wood Frame,Double Pane with Low-E: 9 0.340 3 1x Master Suite(AO):Wood Frame,Double Pane with Low-E: 35 0.340 12 2x Great Room(Y):Wood Frame,Double Pane with Low-E: 31 0.340 11 2x Great Room(AA):Wood Frame,Double Pane with Low-E: 13 0.340 4 2x Great Room(AR):Wood Frame,Double Pane with Low-E: 31 0.340 11 1x Great Room(AL):Wood Frame,Double Pane with Low-E: 25 0.340 9 1x Great Room(AK):Wood Frame,Double Pane with Low-E: 11 0.340 4 1x Great Room(AQ):Wood Frame,Double Pane with Low-E: 27 0.340 9 Brkfst#17:Glass: 54 0.350 19 1x Dining(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Foyer#1:Glass: 21 0.350 7 2nd Story Walls:Wood Frame, 16"o.c.: 1184 19.0 _ 0.0 63 1x Foyer(AP):Wood Frame,Double Pane with Low-E: 11 0.340 4 1x Bed#3(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 1x Loft(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 2x Loft(Y):Wood Frame,Double Pane with Low-E: 31 0.340 11 1x Bed#2(AB):Wood Frame,Double Pane with Low-E: 31 0.340 11 Bsmnt Wall 1:Solid Concrete or Masonry: 1480 0.0 11.0 94 3x Std Bsmt Wins:Wood Frame,Double Pane with Low-E: 10 0.520 5 2868 Stl Door:Solid: 19 0.240 5 Furnace 1:Forced Hot Air:92 AFUE The Devonshire Page 1 of 6 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Co quirem s.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of hi er kno ge,belief,and professional judgment,such plans or specifications are in compliance with this Code. C' < - / Builder/D/Ntes: /ndows; Company Nam Date Project Pella P The Devonshire Page 2 of 6 CREScheck Software Version 3.7.3 NJ/ Inspection Checklist Date:07/16/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ First Floor Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: ❑ 2nd Story Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Bsmnt Wall 1:Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Windows: ❑ 1x Home Office(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Bath(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Suite(AG):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Master Suite(AO):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(AA):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Great Room(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AL):Wood Frame,Double Pane with Low-E,U-factor:0.340 The Devonshire Page 3 of 6 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AK):Wood Frame,Double Pane with Low-E, U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Great Room(AQ):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Dining(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Foyer(AP):Wood Frame,Double Pane with Low-E, U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Bed#3(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Loft(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2x Loft(Y):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1x Bed#2(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3x Std Bsmt Wins:Wood Frame,Double Pane with Low-E,U-factor:0.520 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Mud#20:Solid,U-factor:0.240 Comments: ❑ Brkfst#17:Glass,U-factor:0.350 Comments: ❑ Foyer#1:Glass,U-factor:0.350 Comments: ❑ 2868 Stl Door:Solid,U-factor:0.240 Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:92 AFUE or higher Make and Model Number: Air Leakage: ._� . ._......_...__.....- The Devonshire Page 4 of 6 ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. The Devonshire Page 5 of 6 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5'to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) The Devonshire Page 6 of 6 - NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-8511 February 19, 2007 Job#46216 New York State Dept. of Health 77 Mohican Street Glens Falls,NY 12801 RE: Sutton Place Subdivision - Queensbury(T) 12 Essex Court (Lot # 3) Septic System Dear Sir/Ma'am: This letter is to inform you that we inspected the completed septic system for the house at 12 Essex Court (Lot#3) in the Sutton Place Subdivision on December 11, 2007. The septic system as installed was for a four bedroom house and consisted of a 1,000 gallon septic tank and 150 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, E Thomas R. Center Jr., PE cc: Dave Hatin, Town of Queensbury FEB Eric Wilson, The Michaels Group