Loading...
ResCheck03-072,Permit Number ID 7 REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release la Data filename:C:\Program Files\Check\REScheck\2283-01 CATERBERRY-F ARONE-LOT 72-12 RUSH HOLLOW, QUEENSBURY .rck ‘TITLE:PLAN NO.2283-01 CANTERBERRY COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:02/05/03, DATE OF PLANS:FEBRUARY 4,2003 PROJECT INFORMATION: THOMAS J.FARONE AND SON LOT 72-12 RUSH HOLLOW QUEENSBURY COMPANY INFORMATION: WILLIAMS &WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=416 ‘Your Home UA=332 20.2%Better Than Code (UA) Gross Glazing Areaor Cavity Cont.or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 14030000 40 Wall I:Wood Frame,16"o.c sd 19000 56 Window I:Vinyl Frame:Double Pane with Low-E 131 0.320 42 Door I:Solid 21 0.130 3 Door 2:Solid 35 0.130 5 Door 3:Glass 42 0330 14 Wall 2:Wood Frame,16"0.c.1129 1900.0 37 Window 2:Vinyl Frame:Double Pane with Low-E,179 0320 57 Floor 1:All-Wood Joist’Truss:Over Unconditioned Space 123819000 58 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT:The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.‘The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements,When a Registered Design Professional has stamped and signed this page,they are attesti est of his/her knowledge,belief,and professional judgment,such plans or vue 1 4-09 sREScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release la DATE:02/05/03, ‘TITLE:PLAN NO.2283-01 CANTERBERRY Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: 1.Wall 1:Wood Frame,16"0.c.,R-19.0 cavity insulation Comments: 2.Wall 2;Wood Frame, Comments: 0 cavity insulati ‘Windows: 1.Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features; Panes Frame Type_‘Thermal Break?{]Yes[_]No Comments: 2.Window2:Vinyl Frame:Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features; #Panes___Frame Type__Thermal Break?]Yes[_]No Comments: 1.Door 1:Solid,U-factor:0.130 Comments te2.Door 2:Solid,U-factor:0.130 Comments: 3.Door 3:Glass,U-factor:0.330 Comments: Floors: 1,Floor1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity i‘Comments: Heating and Cooling Equipment: 1.Fumace 1:Forced Hot Air,92 AFUE or higher Make and Model Number | | | | | | | | | | | | | | i | | | | | | |Doors: | I | i | | I | | | I | | | i |Air Leakage: |Joints,penetrations,and all other such openings in the building envelope that are sources of air |leakage must be sealed. |Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly |with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a |3"clearance from insulation. | Vapor Retarder:[1|Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions, Materials and equipment must be identified so that compliance can be determined, Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-I1 Return ducts in unconditioned attics or outside the building must be insulated to R-6, ‘Supply ducts in unconditioned spaces must be insulated to R-I Return ducts in unconditioned spaces (except basements)must be insulated to R-2. Insulation is not required on return duets in basements. Duet Construction: All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes.Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. ‘The HVAC system must provide a means for balancing air and water systems, ‘Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the ‘water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1 Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table | ‘Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources.Pool pumps require a time clock Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F orchilled fluids below 55 °F must be insulated to the levels in Table 2 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes irculating Mains and Runouts Over 2" Heated Water Non-Circulating Runouts ‘Temperature (F)Upto 1.25"1.5"to 2.0" 170-180 10 1S 140-160 0s 10 100-130 05 05 Table 2:Minimum Insulation Thickness for HVAC Pipes. Fluid Temp.Insulation Thickness in Inches by Pipe Sizes Piping System Types,Range(F)2"Runouts I"and Less 1.25"to"2.5"to4" Heating Sys Low Pressure/Temperature 201-250 1.0 1s 1s 20 Low Temperature 120-200 0.5 10 10 15 Steam Condensate (for feed water)Any 10 10 1s 20 Cooling Systems Chilled Water,Refrigerant,40-55 05 05 0.75 10 and Brine Below40 1.0 Lo Ls 15 NOTES TO FIELD (Building Department Use Only)