envelope leakage test Envelope Leakage Test ZD\ Testing Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury , NEW YORK 12804 Phone: 5188573144 Email: tony@locascioenergysolutions.com Building Information: Customer Information: Project ID: 58 Wedgewood Name: Schermerhorn Holdings Address: 58 Wedgewood Dr Address: 536 Bay Rd Queensbury, NY 12804 Queensbury, NY 12804 Geo-Tag Data: Latitude: 43.325645 Longitude: -73.684659 Ti mesta m p: 2020-03-06 11:13:14 Measured Leakage: 829.7 CFM50 Test ID: 58 Wedgwood Purpose of Test: RESNET Multi-Pt Env. Leakage Measured ACH50: 4.92 (+/-2.2%) Effective Leakage Area: 40.6 in2 Building Volume: 10,127.0 ft3 Enclosure Surface Area: 1,066.0 ft2 Flow Coefficient(C): 54.5 (+/-9.8%) Exponent(n): 0.696 (+/-0.028) Correlation Coefficient: 0.99976 Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 67 °F Outdoor Temp: 40 °F Altitude: 455.0 ft Time Average Period: 10 seconds Test Date and Time: 2020-03-06 11:55:08 2000 • Depressurize — R 600 500 J 400 c 300 c 200 100 4 5 6 7 8 910 20 30 40 50 60 70 Building Pressure(Pa) Envelope Leakage Test (Page 2) Test Readings: Target(Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow(cfm) Config Baseline -1.7 -60.0 -61.2 -59.5 -28.4 971.3 Ring A -48.0 -49.4 -47.7 -205.5 849.0 Ring B -35.0 -37.5 -35.8 -139.3 700.2 Ring B -23.0 -23.6 -21.9 -68.5 492.6 Ring B -10.0 -13.5 -11.8 -28.2 317.5 Ring B Test Equipment: Flow Device: Model 3 110V Fan Serial#: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge: DG1000 Serial#: 3173 Calibration Date: 2019-02-18 Deviations from Standard: • None Comments: Report generated by TEC Auto Test version 1.6.3 (2), ©2019 by The Energy Conservatory, Inc. Envelope Leakage Test Testing Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury , NEW YORK 12804 Phone: 5188573144 Email: tony@locascioenergysolutions.com Building Information: Customer Information: Project ID: 62 Wedgewood Name: Schermerhorn Holdings Address: 62 Wedgewood Dr Address: 536 Bay Rd Queensbury, NY 12804 Queensbury , NY 12804 Geo-Tag Data: Latitude: 43.325585 Longitude: -73.684774 Ti mesta m p: 2020-03-06 11:10:34 Measured Leakage: 451.4 CFM50 Test ID: 62 Wedgwood Purpose of Test: RESNET Multi-Pt Env. Leakage Measured ACH50: 2.57 (+/- 3.2%) Effective Leakage Area: 19.2 in2 Building Volume: 10,530.0 ft3 Enclosure Surface Area: 1,170.0 ft2 Flow Coefficient(C): 23.9 (+/- 14.0%) Exponent(n): 0.751 (+/-0.040) Correlation Coefficient: 0.99957 Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 65 °F Outdoor Temp: 40 °F Altitude: 518.0 ft Time Average Period: 10 seconds Test Date and Time: 2020-03-06 11:43:05 600 500 • Depressurize — E 400 w 6- 300 fa 200 3 188 m 80 70 60 4 5 6 7 8 910 20 30 40 50 60 70 Building Pressure(Pa) Envelope Leakage Test (Page 2) Test Readings: Target(Pa) Bldg (Pa) Adj Bldg (Pa). Fan (Pa). Flow(cfm) Config Baseline -2.4 -60.0 -62.5 -60.0 -82.0 538.6 Ring B -48.0 -50.2 -47.8 -59.7 460.1 Ring B -35.0 -36.9 -34.5 -38.0 367.7 Ring B -23.0 -24.0 -21.6 -126.2 255.9 Ring C -10.0 -13.7 -11.3 -46.7 153.7 Ring C Test Equipment: Flow Device: Model 3 110V Fan Serial#: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge: DG1000 Serial#: 3173 Calibration Date: 2019-02-18 Deviations from Standard: • None Comments: Report generated by TEC Auto Test version 1.6.3 (2), ©2019 by The Energy Conservatory, Inc. Envelope Leakage Test Testing Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury , NEW YORK 12804 Phone: 5188573144 Email: tony@locascioenergysolutions.com Building Information: Customer Information: Project ID: 64 Wedgewood Name: Schermerhorn Holdings Address: 64 Wedgewood Dr Address: 536 Bay Rd Queensbury, NY 12804 Queensbury, NY 12804 Geo-Tag Data: Latitude: 43.325591 Longitude: -73.684814 Ti m esta m p: 2020-03-06 11:08:17 Measured Leakage: 715.9 CFM50 Test ID: 64 wedge Purpose of Test: RESNET Multi-Pt Env. Leakage Measured ACH50: 3.83 (+/-4.7%) Effective Leakage Area: 28.3 in' Building Volume: 11,223.0 ft3 Enclosure Surface Area: 1,247.0 ft' Flow Coefficient(C): 33.8 (+/- 19.1%) Exponent(n): 0.780 (+/-0.055) Correlation Coefficient: 0.99926 Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 65 °F Outdoor Temp: 40 °F Altitude: 420.0 ft Time Average Period: 10 seconds Test Date and Time: 2020-03-06 11:30:13 11Of. 700 • Depressurize — E 600 0. w 500 400 m 300 C 200 188 4 5 6 7 8 910 20 30 40 50 60 70 Building Pressure(Pa) Envelope Leakage Test (Page 2) Test Readings: Target(Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow(cfm) Config Baseline -2.6 -60.0 -63.0 -60.4 -213.5 865.3 Ring B -48.0 -51.4 -48.8 -155.4 739.2 Ring B -35.0 -38.3 -35.7 -98.5 589.8 Ring B -23.0 -26.3 -23.7 -54.3 439.2 Ring B -10.0 -11.5 -8.9 -73.8 194.3 Ring C Test Equipment: Flow Device: Model 3 110V Fan Serial#: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge: DG1000 Serial#: 3173 Calibration Date: 2019-02-18 Deviations from Standard: • None Comments: Report generated by TEC Auto Test version 1.6.3 (2), ©2019 by The Energy Conservatory, Inc.