special inspection CONSTRUCTION TECHNOLOGY
INSPECTION &TESTING DIVISION,P.D.&T.S., INC.
4 William Street,Ballston Lake,New York 12019
Phone: (518)399-1848 Fax: (518) 399-1913
CLIENT: AJ CATALFAMO CONSTRUCTION, INC. REPORT NUMBER: 1 :PAGE: 1
5 SIXTH AVENUE INSPECTION DATE: 02/25/20
HUDSON FALLS,NEW YORK 12839 OUR FILE NUMBER: 100.126
FIELD INSPECTOR: DAVE CASAW
ATT'N: MR.NEIL KIERNAN
PROJECT: JENKINSVILLE PARK MAINTENANCE FACILITY, OUEENSBURY, NEW YORK
REINFORCING, STRUCTURAL & LIGHT GAUGE STEEL :: FIELD OBSERVATION REPORT
SPECIFICATION FOR BOLTED CONNECTIONS: AISC:AMERICAN INSTITUTE OF STEEL CONSTRUCTION
SPECIFICATION FOR COLUMN PLUMBNESS: AISC:AMERICAN INSTITUTE OF STEEL CONSTRUCTION
SPECIFICATION FOR FIELD WELDING: AWS:STRUCTURAL WELDING CODE-STEEL(A.W.S.D1.1)
SPECIFICATION FOR CONCRETE REINFORCEMENT: CRSI:CONCRETE REINFORCING STEEL INSTITUTE
COLUMN ELEVATION SHOP/FIELD COLUMN THREADED
LINE OR LOCATION FABRICATION PLUMBNESS FASTENERS REMARKS:
ITEM: 1
COL/LINE ROOF
ACCEPTABLE COLUMNS PLUMBED TO WITHIN 1:500.
A/B @ 1/4 ELEVATION
ITEM: 2
COL/LINE ROOF ACCEPTABLE THREADED FASTENERS INSTALLED AND
A/B @ 1/4 ELEVATION TENSIONED TO BEYOND HAND-TIGHT.
ITEM: 3
COL/LINE ROOF ROD TYPE X-BRACING PROPERLY
A/B @ 2/3 ELEVATION ACCEPTABLE INSTALLED AND TENSIONED.
ITEM: 4
COL/LINE WALL ACCEPTABLE ROD TYPE X-BRACING WITH TURNBUCKLE
A/1 -B/1 PROPERLY INSTALLED AND TENSIONED.
ITEM: 5
REPORT DISTRIBUTION: RESPECTFULLY SUBMITTED,
I:FILE 5: CONSTRUCTION TECHNOLOGY
2: 6: Rete&tf
3: 7: ROBERT BEHAN(NICET)
4: R: MANAGER TECHNICAL SERVICES