Loading...
2007-577 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4z Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20070577 Date Issued: Wednesday, March 05, 2008 This is to certify that work requested to be done as shown by Permit Number P20070577 has been completed. Location: 15 POLLAZZO Ct Tax Map Number: 523400-290-017-0002-021-000-0000 Owner: SCHERMERHORN RESIDENTIAL HOLDINGS, L Tax Map Number: 523400-290-017-0002-021-000-0000 Applicant: AMEDORE HOMES Owner: AMEDORE LAND DEVELOPERS LLC This structure may be occupied as a: Fireplace By Order of Town Board Garage - 1 Car Attached TOWN OF QUEENSBURY Townhouse Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070577 Application Number. A20070577 Tax Map No: 523400-290-017-0002-021-000-0000 Permission is hereby granted to: SCHERMERHORN RESIDENTIAL HOLDINGS, L For property located at: 15 POLLAZZO Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCHERMERHORN RESIDENTIAL I 536 BAY Rd Suite 2 Fireplace g Garage- 1 Car Attached QUEENSBURY,NY 12804-0000 Townhouse $100,000.00 Total Value $100,000.00 Contractor or Builders Name/Address Electrical Inspection Agency AMEDORE HOMES 1900 WESTERN Ave ALBANY,NY 12203-0000 Plans &Specifications 2007-577 2358 sq ft townhouse with 472 sq ft attached garage and 1 fireplace $377.32 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, October 04, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tor o Bens u day October 04,2007 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Check Residential Plan Review: One& Two Family Dwellings Y/N!N/A 2)Full sets of plans Over 1,500 sq. ft. —Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size ti Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. "Max.Height above floor LlResidential Check Paperwork Compliance and Inspectors Checklist: OK proofing/Waterproofing Materials On Plans undation Drainage On Plans,if required Yl� 6"Drop in 10'Exterior Grade &ng Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where equired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls J�a rms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width tair Run and Rise Winder Run and Rise Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location fatety Fixtures Proper Clearance h,36"nun. More Than One Riser On Open Sides d Guards>30"/Basement Stairs Included/Closed Risers More Than 4 in Ht. zing Notes For Required Areas Garage Fire Separation Irleage Floor Sloped Attic Access JkRoof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Community Development Office own, of Queerrsburrl Bail Road • Queenshurif, N'cw fork ^12804 tarihin Ryba, Executive Director• DmPi:i Hatin, Director of Beritdina& Codes ; -raig Brown, Zoning Administrator co-+n-1 i V-N --------------------- - BUILDING PERMIT CALCULATION SHEET: 1 ,s pakct;zzo Gf, NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS REQUIRED ACTUAL ACTUAL LIGHT REQUIRED SQUARE FOOT AREA OF ROOM IN LIGHT VENTILATION HABITABLE ROOM SQUARE FEET 8"OF ROOM AREA SQUARE V F ROOM AREA SQUARE OPENING FOR REMARKS FOOTAGE OF ROOM AREA FOOTAGE EGRESS � D;Nk, ma 141 , (p 11 , 33 cpcp 1? 6011 '3reo k�'asF- 14 .4 11,11 9,2 5- 02?, 3 15.,' a51. o1 0, Qq y�, g Ita q � 5�7 1 3 r 1- 1.21 13,95 14, 1 b,9CP -1 . ,a` CP' Q ` M3 1gy.R(p 151ili 3q, 1 T55 110 Sr QUESTIONS 7 CALL 761-8266 OR EMAIL t codes�gueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.guensbu[y.net B 10-LTR I1-20 dF ,- �Toozlvtl munity Development Office of Queen=burr/ • 742 Bay Road • Queensbury, New 1 ork •1-2804 Marilyn Ryba, Executive Director • David Hatin, Director of Bltildi rg& Cedes Craig Brozon, Zoning Administrator I'VLND O W S CHED LILE - JOB SITE/ADDRESS: f 5 ?clazzo Ck, DATE: € OWNER: APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OP. WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER MODEL/TYPE VENT WIDTH IN INSTRUCTIONS ON PLAN NAME CALL WIDTH HEIGHT OPENING INCHES IN SIZE _ a INCHES 33t4 J063�4r 7y. a �� �0 �p� � ���f�lt �?Cot ���r �I a�cis �9 3i (P5 F ;ac- 7a$ 72 Tea" . / 7-7 7-3111w''l r ucommum Development Office ' own ofQueen_buru • 742 Bay Road • Queensbury, Nez,, lord: •11804 Marilyn Rtiha, Executive Director• David Hatitz, Director o/ Bteildi�Tg F, Cedes Craig Brown, Zoning Administrator ck- I VLND 0 W S CHED ULE JOB SITE/ADDRESS: I J� t?alq zz o <:�,T'j DATE: OWNER: APPLICATION NO.: UNIT OR CLEAR WINDOW- MANUFACTURER WINDOW STOCK ROUGH ROUGH SO CLEAR FT. OPENING NO.OP, WINDOW NUMBER OPENING OPENING SO EGRESS/CLEAR HEIGHT FT. OPENING SPECIAL HARDWARE OR LETTER MODEL/TYPE CALL VENT WIDTH IN IN INSTRUCTIONS ON PLAN NAME SIZE WIDThi HEIGHT OPENING INCHES INCHES .rr..rrrr...r...r...r..rr r.r.r....r.rr...r......r r r..r.........r . ,..rrr....rrrr..••••r-- -i OFFICE USE"NLY - ' '# ii o TAX MAP NO. PERMIT N0. MIT FEE ` ' ► , ► ► ► , ► ` APPROVALS: ZONING TOWN CLERK 0 ► :.....r.r...r...r...rrrr..r.......r...r... .......r....r.! ►...................... APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. A ,�D f��� OWNER: -'o©I�-6' INSTALLER: � L ADDRESS: tco "� '� ADDRESS: PHONE NOS. PHONE NOS. /®l Q ' ✓ �3 LOCATION OF INSTALLATION: �- ......._...................-...........................................................................................................................-...............i...........1..........................................................................t RESIDENCE INFORMATION, YEAR BUILT N0.OF X COMPUTATION= ! _ TOTAL DAILY FLOW i ........ -......................... .BEDROOMS..-�i.. ... .................................................................:a....... _........................................... i GARBAGE GRINDER µµ1980 or older ..X 150 gallon per bedroom _ I INSTALLED? 1981 -1991µ - -- X - 130 gallon per bedroom = SPA OR HOT TUB -1992-present.. ,....X. ...-110 gallon per bedroom. ......_...................................................................::..:..: INSTALLED? .................................................. ........._..4...........................................................ZSTEEPSLOPE- ....................._.............................................m..............� PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING %SLOPE ✓ SSOIL NATURE: SAND LOAM CLAY OTHER ✓ GRQUNDWATER AT WHAT DEPTH? BEDROCOMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub., ✓ SEPTIC TANK: . GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH FT. ✓ TOTAL SYSTEM LENGTH: FT. SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH FT. X FT. ✓ SIZE OF STONE TO BE USED:# /DEPTH OR THICKNESS FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTHANDIOR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO.OF TANKS: I SIZE OF EACH ✓ GALLONS.ITOTAL CAPACITY. GAL. ............................................................................................................................:.............:.....:.......................>....,..,.,.,...:.r..................................................................:.:...........:...................................................,................ ...,...,...,.,.,. 4; NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. is �1....::::.......::..:..::.::...:.:.:.....:......:.......:.:.:............ •......•...........a..... •.v..•;.r.:,.:...:.n;•;•;a•;a•;u•;•;n•:v.•nn:...........:•:.ao:...:•:.............................:.,.:.:...:.::.:.:.:.:.n:..................... o.............. ........•..............on........ For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by.or on behalf of an applicant, shall be void I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761.8256 OR EMAIL Queensbu Sanitar Sewage isposalOrdinance. codes 6gueenaburv.net VISIT OUR WESSITE FOR MORE INFORMATION j� www.aueen>;.burv.net A.Signature f Per n Respo ble Date �� Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 j --- � �- --- OFFICE USE ONLY ________________________ �-------------------- ?2 -ZI TAX MAP NO. PERMIT NO. FEES: PERMIT_ RECREATION. ENGINEERING (if applicable) `.y+YF, ,___....._._..____... PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VAL/IQ PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: OWNER: sa" r ADDRESS:l-1 Ck9 CQJ- c..- ry • �K� �J 1 1Z263 ADDRESS: Sc,_ , PHONE NOS. U PHONE NOS. S � CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: —mc.,K- PHONE: J7��. ZM 7 LOCATION OF PROPERTY: 1 (Co SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS QU D B z CHECK ALL THAT APPLY TO YOUR zz 0 xO p d a W L PROJECT _ W w 0w � LLU w U ~ W J d 0 z nCN � LL z a = 02s i SINGLE FAMILY I I TWO-FAMILY MULTI-FAMILY (NO.of UNITS-) . - - zvT z rG -- - -- f 905 2-3 TOWNHOUSE ✓ , � ZCo BUSINESS OFFICE j RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED --- / y'1Z 1 °w GARAGE(1,2,3) I i I OTHER IF COMMERCIAL OR INDUSTRIAL-N�jME OF BUSINESS: ESTIMATED CONSTRUCTION COST:'(] &6 WO Pl as "plete a separate Application E for F 'jrning Appliances&Chimneys HOW MANY FIREPLACE(S):_ AND/OR WOODSTOVES(S): au„ 0 (nir office 12N_•'= ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: B 3-LGL 1 l-05 Town of'Queensbury • Community Dcvelopnlent Office - 742 Bay Road, Quccnsbuiiy, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? �� ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to a above. Signed G Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits the permit process, application requirements or to schedule an appointment) __________________________________________ ;_____y__..__________._. ..___________________- I I t Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: I t , I - , t ' t I I ' % I I t I t t , ' I t t t BUILDING & CODES APPROVAL ZONING APPROVAL ; t ;I , I , I i DATE DATE I . I t ' I _._-__. --- ----------- --_-____.__-. . . . .____-______._____ I ;QUESTIONS 7 CALL 761-8256 OR EMAIL codes(ab-gueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensbury.net Town c f Queensbury - Community Development 0JfiC(' 1 742 Bay Road, Quccnsbuiy, NY 12804 I �r Rough Plumbing / Insulation Ins ection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: / - O� am/pm,, Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: A , r,�e - f PERMIT #: LOCATION: . INSPECT ON: -11-ZZI TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head w 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air, d .S.I f 15 minutes Insulation JjAesidential Check Commercial Check (41Fent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly No duct tape COMMENTS: LAPam Whiting\Building&CodeOnspection Forms\Rough Plumbing Insulation Rcport.revised Nov 17 2003.doc Revised February 15,2005 Queensbury Building & Code Enforcement - ResideFnspection Office No. (518)761-8256 Arrive: : arn/pmDate Inspection request r ived: Inspector's Initial NAME: __LOCATION: TYPE OF STRUCTURE: Commends: Yes No WA 4' Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brae /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior prtvacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazin /Window in Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battiry backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft Emergencybelow grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operAN Low water shut-off boiler Relief Va s installed/Heat Trap!Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fiWroofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure Final Electriowl Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bond" As Built Septic System/Sewer Dept. Inspection S' er Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Tern l ems L'11� L:\Building&Codes Forms\Suilding&CodesUnspecaon Forms\Resi kmU Final inspection Form_revised_100405.doc;Revised January 7,2008 Final Survey--inspection Dept.of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: -2140Y NAM64�le&)*C LOCATION: 5 ;;*�-/let 770 PERMIT#: do I ` 57 7 Final Survey Plot Plan ARvroved Denied The attached final survey has been received by the Dept.of Community Development. Upon review th sFn�ey has Craig ,Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc MAP REFERENCE; HAVILAND ROAD SUBDIVISION BY VAN DU5EN + 5TEVE5 DATED OCTOBER 14. 2005 LAST REVISED MARC" 16, 2000 LOT O 20 C3 ►.00 4 Sgs038 fig„ .001 ti LOT 21 Q2 G AREA �36 OQ �z 8,323. 11 sq. ft. 0. 19 acres 0 �-1��� n �N , ''VA, r- 0 Vi tv tg•a O j �N 41 ' •O �(ko �W V°QP LOT 23 20' 5EWER EA5EMENT �I LOT ?m E 22 AREA 8,522,53 sq. ft. N.O.A. 0.20 acres 3� �QQ OQ 1. 19�' 20' 5EWER EASEMENT p E C MAN 0 4,. TOWN OF surmlfV & CODS E �� 077 oo7ov 'UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY Dates November 20, 2007 V UAP A LICENSED LAND SURVEYORS� IS A Ma of a Survey made for Scale 1'=20' MOLAROH OF SECTION Tom,SUS-DM%ON z Of THE P y p �t NEw YM surf EDUCATION LAX- 'ONLY t✓ S COPIES CRI TINENAL ORKKTHE AN SUHISRVEYORS SURVEY LIE L NTTN AN oPoaNu of THE LANDS RUE O PI � �DONSIDERED TN�VA�TR�E - AMEDC}RE LAND DEVELOPERS, LLC CERTIFICATIONS INDICATED HEREON suaFY THAT THIS SURVEY WAS PREPARED W ACCORDANCE YATN tHE L a 11 cl S u r v E�y o r s E>05RN0YOW �S FOR LAND OF PROFESSIONAL ADOPTED By THE NEW ORS, STATE ASSOC TION of SHALL RUN ONLY N Y LAND SURVEYORS SAID CERIIFN;AThNiS SHALL RUN OfbY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND ON HAS MAU To THE TITLE COHPANY,MVERIMENTAL SHEET�of 1 AGENCY AND LENEENG INSTITUETIDN LISTED NEREoN,AND 169 a and Road Queensbury, New York 12804 TO THE ASSIGNEES OF THE LENDING INSTITUTION Town of Queensbury, Warren. County, New York 1 3/D3/08 UPDATE SURVEY Amedore (518) 792--8474 New York Lie. No. 50135 NO. I DATE DESCRIPTION DWG. NO. 0514G-21_22 Queensbury Building & Code Enforcement - Resi en ial pection Office No. (518)761-8256 Arrive: 3=L57a pm De rt: a� Date Inspection request received: Inspector's Initials: NAME: ; E IT#: LOCATION: ,-, D E: TYPE OF STRUCTURE: Comments: Y No WA 4' Budding Number Address visible from road Chimney Height/'B'VentUrect Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 irw hes above grade 18 Guard at stairwell at 34 khdies or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Bderior Railings 34 inches to 38 inches Deck Brae /Hand" Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch dearance to sill Plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim I doors/main entrance 36 inches Bathroom/Krtdhen watertight S /Window in stairwells safety a" of Interior Smoke Dete s/Carbon Monoxid�f)etedors Every level: Vaq Bedrg6m: Outside every bed area: / Inter Connected: Battery badw : Attic access 30 inches x 22 indhes x 30 inches in avoessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing Mures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area 10, Furnace/1-lot Water Heater operating Low water shut-off boiler Relief Va s installed I Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Dud work Sealed Properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic S ernQeYwer ggpt. Ins " n Shdker Site Plan /Variance reciuirdff- Flood Plain Certification,if iced Okay to issue C/C or C 10 Temporary/Permanent I-Muilding&Codes FormslBuikling&Codesllnspec ion FormsV2esklential Final inspection Form_revised_100405.doc;Revised January 7,2008 Queensbu Building & Code Enforcement - Residential Final V,64�h> 1� rY 9 Office No. (518)761-8256 q Arrive: a rt: n•Z a Date Inspection request received: � Z/ a Inspector's lnitia NAME: '`�C� e C' S PE IT LOCATION: ►4It A7 Z� cov D TYPE OF STRUCTURE: Comments: Yes No N/A 4' Building Number Address visible from road Chi I'W Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches J Roof /Exterior Finnish Complete1 Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade i._ Guard at stairwell at 34 inches or more "�� ��EL Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall aL j a Ja Interior/Extedor Rail` 34 inches to 38 inches , i Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill Mate Gas Valve shut-off exposed/regulaW 18 inches move arade Interior privacy I trim I doors/main entrance 36 inches Bathroom/Mchen motertight Vy Safety glaziM/Whiglow in stairwells safe �� "A A71 j2 N� Interior Smoke ors/Carbon Mono ` Every level: Ev Bed2o : Outside every bedroom rea: _ /�Inter Connected: B badku L Attic access 30 inures x 22 inches x 30 inches in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents N�ttl k L Bathroom Fans,if no window y Plumbingfixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency below grade / *1 Gas Furnace shut-off within 30 feet or within One of site j T��- 1J Oil Furnace shut-off at entrance to furnace area 77 Fumace/Fbt Water Heater o Low water shut-off boiler Relief Va s installed/Heat Trap/Water Tem 110 Enclosed Stairs Sheetrock Underside minimum''Gypsum Basement stairs dosed rise>4 inches Iff Garage Floor itched Garage fireproofing/'/.hour fire door/door closer Duct worts Sealed propertv55 Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer De .Inspection Sticker Site Plan /Variance cared Flood Plain Certification,if regyired Okay to issue C/C or C 10 T /Permanent L:1Buiiding&Codes Formsftilding&Codesllnspec4on Forms;%Residentiai Final inspection Form revWed_10D405.doc;Revised January 7,2008 �a Twra of Q•eendm•q Fat NLanbal 742 Bay Rand Query,NY 12M 761-SM/761-52®6 fa=7454437 Factory Built Gas Fireolaee/Stove iasnection RO rt Notion New Veit State mgnuu thA t aR UL ice,factory bsdt be i+nstaMed awocdW to the ashraction asd costained is the lustaNation Manual aeaassp=yig the appiaom No&whWw fic+oaa the wafadrrws or ape /� Moss is aaow ed. P*rw*# scbedrde laspectio. V IUW am pr anyae [aspedw-(,t�-45 = Vase Adds / i � � Gam' In Fitad a�• M �7. Dwed V Factory Bait C'buwwy Floe Sine Doablo WA Triple WaR sedated Yea No NIA Oasts Floor Protedion ��'IL 0Fd� �- l? Clearances to Combustibles(a„asiks) rw estop(s) Vertical Cl WA P Vent Clearances to Combustibles d, Vent/Chimney Termination Clsasaey bed and be 3 feet above red ptitetr-"m-;2 fed above my cow ooadrsictim withis to feet Gas Sbut-Off Valve Combustion Air Hearth Extension(if any) Mantel Reqpt above Op Witness Operation Tank Placement Qf LP) Wwk-Ragang Deft. Yc11uw lick_Pone�1Pitnid MIDDLE DEPARTMENT INSPECTION AGENCY, INC. '6W��that the electrical wiring to the electrical equipment listed below has been examined and is approved as i being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. i Owner: Amadore Date: 02/27/2008 i Occupant: Unknown Location: 15 Palaggo Ct. Occupancy: Single Family Dwg. Queensbury,Warren Co. NY f Applicant:F r Immanuel Electric Inc. � � 2 Mohawk Ave. rgz = € Alplaus,NY 12008 , _ V 74 . � JP % Raymond A. Nov , m No. 14086� _ - _ - - W1111%, Equipment: r 1 200 -Amp. Service Equipment 4/G - chest 4 eptacles ixtures ] mAir Corwitioner; 1 - Burner, Wiring & Controls; 1 -Garb h e Disposal; 1 - Dishwasher; 1 - Dryer; 3 -20 Amp. Receptacle ; 3 Vent Fans; 6 Smoke Detectors; 1 Carbon Mfoxid Vi_5 AW z a .:... 0 r This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspe7-ff9am/p uest received: Queensbury Building &Code Enforcement Arrive: part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 6- PERMIT #: LOCATION: L i:5-- Arc-/+z2v CT INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rou h Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test W er Supply Piping it/ Head 50 P.S.I for 15 minutes vJ Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If re uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whitinouilding&CodesUnspection FornulRough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection Cpquest received: Queensbury Building &Code Enforcement Arrive: :Z am/p .9�part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: q`" NAME: A m beRC— PERMIT #: e3-7 7 LOCATION: 1 /04 e Ll-� 2Zo ,� >'. INSPECT ON: _ d TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head /L��}�j 1� jo 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Wa upply Piping / Head 0 P.S.I for 15 minutes Insulation Residential Check Commercial Check Pro er Vent Attic Vent Duct/ Hot Water Piping Insulation Cow pa-fc AT If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape e��' k?rly. 1A) (V6,0-r '1kA0 r11z4 COMMENTS: LAPam Whitinouilding&CodeAnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection realest received: Queensbury Building &Code Enforcement Arrive: A < 166m/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: --� NAME: L-P'01eL= PERMIT #: 0�--5-7 LOCATION: ,�5— , INSPECT ON: ` s' TYPE OF STRUCTURE: Y N NIA Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout eve 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Ajpf Head 0 P.S.I for 15 minutes Insulation Residential Check Commercial Check v Pam Proper Vent Attic Vent ` Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace L_ Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodeAnspection Form sms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 /D--%Z -7) S 1D,QA-1 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ection uest received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's I i ials: �- " NAME: �PERMIT#: - T LOCATION: INSPECT ON: TYPE OF STRUCTURE: ; r Y N N/A COMMENTS =cess 22"x 30"minimum 4— JLC Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly I Rv�1 ��� V S 12"O.C. _A A l,J Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/a w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed _ 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf ade Amr1w Co,P�ero N - -Dr,2C cT 9&tJ I 7 a-f,, 4 o0Zr7,"l 7q Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspe jo�.c'equest received: Queensbury Building&Code Enforcement Arrive: t �am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: ��� �7' LOCATION: 5 INSPECT ON: TYPE OF STRUCTURE: Y N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `/z w) 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour 're wail 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side t/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade C// 4 ao Rough Plum in Insulation nspection Report Office No. (518) 761-8256 Date Inspmrsitials: uest received: Queensbury Building & Code Enforcement Arriveam/M��! part: am/pm 742 Bay Road, Queensbury, NY 12804 Ins NAME: APERMIT #: 427 ,� Z LOCATION: a INSPECT ON: TYPE OF STRUCTURE: Y NIA Rough PlumbirW Nail Plates PlumbingWint Vents in Place nch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction ssure Test Wen Heoard ft. above highest connection for 15 minutes Pressure est er Supply Piping Air / Head P.S.I for 15 minutes Insulation Residential Check I Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Fornis\Rough Plumbing Insulation Report-revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No.(518)761-8256 Date In tio�Nuest received: Queensbury Building&Code Enforcement Arrive: Jam/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto s Initials: �-'�-- NAME: PERMIT#: 6? LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foot' or Keyway in place Fours on pproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width es a ve footing �--- 6 mil 1 or wet areas under slab roval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM i —S Ur-jA e - Framing / Firestopping Inspection Report l —� Office No.(518) 761-8256 Date Inspectionequest received: Queensbury Building&Code Enforcement Arrive:"Z/"6'�am/ m Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: P C--` NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUATUTRE:4 Framing Y N NIA COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses .I' or less on center f l Ice and water shielcl,24 inches from wall G Fire scpamfint-T-,2, 3 hour Fire wall 2, 3,4 hour Firestopping V Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side `/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No.(518)761-8256 Date Inspectionrequest received: Queensbury Building&Code Enforcement Arrive am/ part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: L, PERMIT#: C 7' S7 LOCATION: /°, GG- ?el e 7" INSPECT ON: _ TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Foo ' g Drain Daylight or Sump e-Voting Drain Stone: 12 inch width 6 inches above footing mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection rqRtfe'st received: Queensbury Building&Code Enforcement Arrive: .«n/ epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect is Initials: v NAME: PERMIT#: � LOCATION: INSPECT ON: _ TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing following the placement o e cone te. M erials fo this se on site. Foundation/ llpour Rein entin Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump U Footing Drain Stone: ��bU t'1��� At, bw;r/C0,4L 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior CA&& �_d''e R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection quest received: Queensbury Building&Code Enforcement Arrive: I am/pT Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspectof s Initials: NAME: ->e XC PERMIT#: �0� LOCATION: INSPECT ON: l c � Q'. TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM :�? —Z'/ e4�a'6"l Foundation Inspection Report Office No.(518)761-8256 Date Ins ton:Pr Queensbury Building&Code Enforcement Arrive: epart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi NAME: LOCATION: SPECT ON: — TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Cales\Inspection Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM > -,;� pf%-­ Foundation Inspection Report SJ p Office No.(518)761-8256 Date Inspectiouest received: C ( ( a�� Queensbury Building&Code Enforcement Arrive: _,*jam/pm part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: (All"e -e' VW6,� PERMIT#: 7 — 77 LOCATION: LoT ( " J, INSPECT ON: I 00 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. als for this purpo n site. ounda ion/Wallpo emforcem Place Footinrowel>kr Keyway in place Foun ampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Townhomes at The Havilands Report Date:09/07/07 Data filename: K:\RESCHECK\havilands\15palazzo.rck Energy Code: 2000 IECC Location: Glens Falls,New York Construction Type: Multifamily Glazing Area Percentage: 7% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 15 Palazzo Ct. William Balogh Queensberry,NY 12804 Amedore Homes Inc. 1900 Western Avenue Albany,NY 12203 518-456-1010 wbalogh@amedorehomes.com . • Your __ M E . • Ceiling 1:Raised or Energy Truss: 1753 30.0 0.0 56 Wall 1:Wood Frame,16"o.c.: 3070 19.0 0.0 168 Window 1:Wood Frame:Double Pane with Low-E: 165 0.350 58 Door 1:Solid: 64 0.280 18 Door 2:Glass: 47 0.350 16 Basement Wall 1:Solid Concrete or Masonry: 1433 11.0 0.0 99 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 306 19.0 0.0 14 Furnace 1:Forced Hot Air:90 AFUE Air Conditioner 1:Electric Central Air:13 SEER Compliance Statement:The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date , 5 l �� SSIO�Qy Townhomes at The Havilands Page 1 of 4 REScheck Software Version 3.7.3 Inspection Checklist Date: 09/07/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/6.0'bg/7.8'insul,R-11.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.280 Comments: ❑ Door 2:Glass,U-factor:0.350 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:90 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Townhomes at The Havilands Page 2 of 4 ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5.Ducts outside the building must be insulated to R-8.0. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each dwelling unit(non-dwelling areas must have one thermostat for each system or zone).A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room shall be provided. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Townhomes at The Havilands Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Townhomes at The Havilands Page 4 of 4