2007-593 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20070593 Date Issued: Tuesday, November 13, 2007
This is to certify that work requested to be done as shown by Permit Number P20070593
has been completed.
Location: 100 FOURTH St EXT
Tax Map Number. 523400-309-011-0001-070-000-0000
Owner. ROBERT & SHIRLEY GILMAN
Applicant: ROBERT & SHIRLEY GILMAN
This structure may be occupied as a:
Garage - 2 Cars Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
owner of the responsibility for compliance with Site Planf -
property P tY P ,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20070593 Application Number. A20070593
Tax Map No: 523400-309-011-0001-070-000-0000
Permission is hereby granted to: ROBERT & SHIRLEY GILMAN
For property located at: 100 FOURTH St EXT
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ROBERT& SHIRLEY GILMAN
100 FOURTH ST. EXT Garage-2 Cars Detached $3,000.00
QUEENSBURY,NY 12804 Total Value $3,000.00
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
2007-593
existing 616 sq ft garage, new trusses (22'x 28') &new metal roof
$40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Sunday, October 05,2008
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T i tober 05,2007
o eens ry;
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
J/y / __ )QFFICE USE ONLY----- .......-...,.., ...----- _.._-
TAX MAP NO. PERMIT NO.
FEE PAID BLDG.&CODES APPROVAL
sEP 20 2007
........................... ...-.._------------------ -.TOWN O Q.....
P
.....
ACCESSORY STRUCTURE BUILDING PE 'N
Use this application for any structure other than the Principal Structure (house) to include, but
not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3
entitled Accessory Structures-Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS
RECEIVED A VALID BUILDING PERMIT.
OWNER: lCdr �" L INSTALLER/BUILDER:
ADDRESS: _/C o t�ly �T GX T ADDRESS:
PHONE NOS._ S!� "7 V 3 p o l PHONE NOS.
LOCATION OF PROPERTY:f 6O y�yST�.K T SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: Ld
---
ESTIMATED COST OF CONSTRUCTION: $-���� ANY OTHER ACCESSORY STRUCTURES ON PROPERTY?Q
IF YES,PLEASE LIST:
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: ,"e_,,, PHONE:
PROPOSED CONSTRUCTION 1st Nc PROPOSED FLOOR 2 FLOOR TOTAL HEIGHT
$0.FT. SQ.FT. SO.FT. FT.&
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH"
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK f4
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: 616
OTHER ACCESSORY STRUCTURE: 2X/
*CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with, whether specified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested
by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed
surveyor, drawn to scale, showing actual location of all new
construction.
QUESTIONS? CALL 761-8256 OR EMAIL
1 have read and agree to the above. codes(ftueensburv.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Signed {�o�r�1 Dated: 1 � U www.aueensburv.net
Town of Queensbury- Community Development Office- 742 Bay Road, Queensbury, NY 12804
B I-LGL 11-05
Queensbury Building & Code Enforcement - Res' ent 1 Final spection,
Office No. (518)761-8256 Arrive: I epa m
Date Inspection request received: 1t 7, f}U� Inspector's I ti /
a
NAME: , PE T
LOCATION: D T L/ J00 7
TYPE OF STRUCTURE: qs r
S n w'�e�C d Iments
Yes No N/A
Building Number!Address visible from road
Chimney Height/'B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches ��D
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safely glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft. u ,
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum''/Z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/N hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
rlood
Se tic S stem/Sewer Dept.Inspection Sticker
/Variance re uired `
ain Certification,if required
issue C/C or C/O[Temporary/ rmane
L:\Building&Codes Forms\Building&Codes\Inspection Forms�Residential Final Inspection Form revised 100405.doc
Parcel Information
Municipality:p ty Q ueens bury MEp New Tax Ma Number: 309.11-1-70
Old Tax Map Number: 131.-3-11 OWN o
Location: 100 FOURTH ST. EXBv+LD'A� QUEENSSU Y IMPORTANT NOTICE AND DISCLAIMER
Frontage: 0 r•G 8t CO THIS MAP AND INFORMATION IS PROVIDED
v AS I'AN)
AND WARREN COUNTY MAKES NO
Depth: 0 Rev' WARRANTIES OR GUARANTEES,EXPRESSED
Acres: 0.43000000715 ed ,/a OR IMPLIED,INCLUDING WARRANTIES OF
TITLE,NON-INFRINGEMENT,
Property Class: 1 Family Res ate. �'a,���A MERCHANTABILITY,AND THAT OF FITNESS
Owner: Gilman, Robert FOR A PARTICULAR PURPOSE CONCERNING
THIS MAP AND THE INFORMATION
Current Land Assessment: 18100 CONTAINED HEREIN. USER ASSUMES ALL
Current Total Assessment: 108100 RISKS AND RESPONSIBILITY FOR
/+
- DETERMINING WHETHER THIS MAP IS
Neighborhood Code: 166 SUFFICIENT FOR PURPOSES INTENDED.
Year Built: 1971 - GIS MAPS ARE NOT LAND SURVEYS!
Square Footage: 1 152 This GIS map is computer generated using data acquired by the
Stories: - 1 Warren County Planning Department from various
Bathrooms: 1 sources and is intended only for reference,conceptual,planning
and presentation purposes. While we
Bedrooms: 3 work hard to include reliable data for the stated
purposes,this map is not intended for and should
Sewer: Private not be used to establish boundaries,lines,locations of objects
Water: Comm/ UbIIC or to provide any other information
p typically needed for construction,excavation or any
Utilities, Gas&elec other purpose when engineered drawings/plans or
n surveys are 1)required by law;2)required for any
Heat: Hot wtr/stm y legal document or 3)needed to assure accuracy
C (// and/or that certain standards are met.
Style: R
Book: _ - Warren County Real Property Tax-2005 Roll. Building Footprints
Page, were compiled from 1988 aerial photography and have
not been updated or checked for accuracy.
Saes Dates: 18991230 TOWN OFQUEENSBU;RYSUILDINCDEFPRr Ac
Sales Prices: 0 - Based on our i,mjtea ex Y„M r Nr
compliance With our rc r
( not be const
i rued as lnd ca 0 "Pie
pens and specifications are i" full
compliance With the Suiiding
�$ New York State. � I
co
150
309 - 70
A 50
IS-
,� Cple 1
r
t 150 �I
75
CD75 A 0
1:600 N
5 4
j
_.r e
_t
ti
c�
IZ
X ��s
44
_moo ,
SEP U 2007
Top Chord 2x4 SpF#1*2 110 mph Wind,17.20 ff rneein h9t,ASCE 7-53.CLOSED Mfg,k"Ied anWvfwn,in roof.100 mi from cous4 CAT I,EXP a.wind
Sol cho d 2x4 SPF#1.12 TC Mt4.2 ps',wir i BC DL-2 0 p4
Webs W SPF Stuc tr
All plates are 2X4 exQept as noted C
Gable and supports 8"max rake overhang, See DWGS At 1030EN1103&GBLLET1N44081or more mqu remerrs.
Deflection mass U240 Ova and U180 total load. 0
1 Plates shed for a minimum of 2.40 sq.ln.rysiece. Truss designed fur unbalanced snow lmd u"0.00 windward factor and i;i c.—my m
�n� O
r` ro
w
o v_0 I
o -�-�
- Ui� w
mp
LAj
o
t to
12
6 p r
0
2 4(A1)� _..- -_— - 2X4(A1)
3X4 s
10' 12' -- 1
,gip
2 r..`'�""A{ Rv=257pif U=100p1f W=10'
Rv=234plf U=100pif W=12'
r
U1
J
i w
I O
J
j .h
. O
LEFT RAKE =117 RIGHT RAKE= 1'1"7
LEFT JIG=12'5'8 RIGHT JIG-12'5"8
tAG= T2 SEQ= 177032
PLT,TYP.-WAVE lecaM002tsTDJ WrRT-1.00(i 20y10f of QTY=2 TOTAL.= REV. 7.25.0411.15 SCALE=0.2500
This is a preliminary drawing that can be used TO LL 65.5psf REF
only for trusses fabricated by S.R.Sloan,lnc. TC OL 7.0psf DATE 06-0&2007
R represents loading,span and pi(ch. SO,M.
S.R.Slaan,lnc.re
reseres the right io adjust 10.Opsf DRwG
S. R,3, L fOA NINO materials and design at the f me of production. DC Ll_ Ups f WW
The structural integrity will not be
ROOF&FLOOR TRUSSES CXJSTOM STAIRS&STAIR PARTS compromises.Sealed drawings will be TOT.L13, 32.5ps-f C#A LEN. 22
W
WHITESBORO.NY • ORWIGSBJRG,PA furnished upon request. DUR.FAC, 1.15
V*1-g waG Poscalya ,.woxe-76iz ........._..._..__...._ .....___._..- ---.
wIu,-5-1 uv I&W, �w HvlkvO.Nr Q-0 F„,rs;r�o-rr�, SPACING 24.0" 7yPr GABL
eot ohwd 2x4 SPF#!1N2 TC,60-4.2 psf,wind 11C a32.4 Psf.
WaW 10$PF Stud Lj
Oelbatlon meets L1240 Ova and 11,1160 btal k►rid. C
Trwa daalgntw for UntmbmVd snow bad using 0,00 windwnd fads and 1.80Issward factor. Alat98 shad for a minlmUm Of 2.40 Bq,lhlpbc0,
G9
N
ti O
ra
Q W
�1 CQ
CL
5X7
12
O
;0 3xa 3X4 M
mH
4X10(83)
4X10(B3)
22' — -----Ij
Rv=2243# U=248# W=5"8 Rv=2243# U=248# W�5"8� �.
W
r
Lfl
. +J
W
O
v
.7
O
LEFT RAKE=1'1"7 R1C8HT RAKE=1'1'7
=12'S"S
G T JIG=12,5"S Al HT JIG= T1 90 a 177013
PLT.TYP,-WAVE IWMP1M2(ST7)0:MT•1 txp1.213y13;aI QTY=i3 TOTALn 13 REV. 7,26.0411.15 SCALE-0,2600
This is a preliminary drawing that can be used TC LL 66.5psf REF -
only for trusses fabricated by S.R.Sloon,{nc• TC DL 7.Upsf pATC 08.08 2U07
So � n rt.Slosnts Ioodi ,spar)and pitc fS.R.Sloan,inc,reaerveathe r{ghtl~o adJust BC DI.. , 1Q.4psf pRwG
REL: 0 NINC materials and design at the Ume o1 production. BC LL p,qp$ ww
ROOF&FLOOR TRUSSES CUSTOM STAIRS&STAIR PARTS The compromised.
rote led dra not be i 1'PT.LC.� 82.5psf OIA LEN.~'22
compromised.Sealed drawing:will be ly
WHiTESSORO,NY • 0RWIOS8URr3,PA furnished upon request. p�JR,pgp, 1.15
UIt-rrq•An Pd R"t eiA 1•dC9�?U-r;t
eVa.eto/oNvt�4v� NaMlMixrt.�v,�i:J �m.(iiel' •:ac SPACING 24.U" TYAG CQMN