proposedA
TOWN OF QUEENSBURY
BUILDING DEPARTMENTBasedonourliitedexamination,compliwithourcommentsshallnotbeéonstued|Palate plans ond specications in{ull compliance with:the Building fNewYorkState.
TOWN OF QUEENSBURY
BUILDING &CODE:PT.
Reviewed By:
Date:
2
U
nN~Jtxx
D ECGEIVE
[iL |_may 26 2020
301.12-3-64 SEP-0221-2020 TOWN
OF
QUEENSBURYAllen,Gerald BUILDING &CODES
12 Zenas Dr
Residential Septic Alteration
be
12
Zewps
CENTER PROJECT
Sy RACES
73 Sheridan Street,Glens Falls,NY 12801
Phone ~518-796-2515
May 20,2020
Project #305
George Drellos
Sanitary Sewer Service
Queensbury,NY 12804
Re:Proposed Replacement Septic
12 Zenas Drive,Queensbury,NY
Dear George:
At your request,we have reviewed your proposed replacement septic system design of the
existing 3-bedroom house at 12 Zenas Drive in Queensbury.As per our conversation the
residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable.Based upon a design flow rate of 330 GPD and a percolation rate of
1 to 5 minutes,you will need a minimum of 367 sf of absorption area.We recommend using 20
ft wide by 30 ft long absorption bed with 4 -25 ft long laterals.The absorption system can be
constructed with the existing 1,000-gallon septic tank,new distribution box,and 4-inch diameter
perforated pipe and stone
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,a7a/~_
mabeas Conte Jr,PE.