Loading...
proposedA TOWN OF QUEENSBURY BUILDING DEPARTMENTBasedonourliitedexamination,compliwithourcommentsshallnotbeéonstued|Palate plans ond specications in{ull compliance with:the Building fNewYorkState. TOWN OF QUEENSBURY BUILDING &CODE:PT. Reviewed By: Date: 2 U nN~Jtxx D ECGEIVE [iL |_may 26 2020 301.12-3-64 SEP-0221-2020 TOWN OF QUEENSBURYAllen,Gerald BUILDING &CODES 12 Zenas Dr Residential Septic Alteration be 12 Zewps CENTER PROJECT Sy RACES 73 Sheridan Street,Glens Falls,NY 12801 Phone ~518-796-2515 May 20,2020 Project #305 George Drellos Sanitary Sewer Service Queensbury,NY 12804 Re:Proposed Replacement Septic 12 Zenas Drive,Queensbury,NY Dear George: At your request,we have reviewed your proposed replacement septic system design of the existing 3-bedroom house at 12 Zenas Drive in Queensbury.As per our conversation the residence has an existing failed septic system. We have reviewed the proposed replacement septic system design and we agree that a standard absorption bed is acceptable.Based upon a design flow rate of 330 GPD and a percolation rate of 1 to 5 minutes,you will need a minimum of 367 sf of absorption area.We recommend using 20 ft wide by 30 ft long absorption bed with 4 -25 ft long laterals.The absorption system can be constructed with the existing 1,000-gallon septic tank,new distribution box,and 4-inch diameter perforated pipe and stone Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely,a7a/~_ mabeas Conte Jr,PE.