Loading...
ResCheck.REScheck Software Version 4.6.4 1 Yon 1 Compliance Certificate 2838Cegsa=$ibSz5TwEale2Eg Project Foothills Builders Inc |4 bo |vagEnergyCode:2015 1ecc |NSzLocationGlensFalls,New York |Boest"e |aConstructionType:Single-family Ram Conditioned Floor Area:2,182 f2 paxGlazingArea12%eveClimateZone:6 (7635 HDD)s ogPermitDate:6 Permit Number £&o 8Constructionsite:owneriAgent Designer/Contractor:e 8JohnGlendonDriveDanielW.Ryan PE »8os200Glenstreet Queensbury,NY 12804 Ste0 Glens Falls,NY 12801 518-792-9264 <dryan@dwrpe.com Sie nee UA:268Compliance:1.5%Better Than Code Maximum UA:268°Yo) {DOES NOT provide an estimate of energy use or cost relative to 8 miimumT-co Gross Area Cavity _Cont.eee SCE) 990 38.0 00 0.02525 ron eo rcramy Celling 1:Raised or Energy Truss Wall 1:Wood Frame,16"o.c 1275210 00©0.05763 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 93 0200 27 Door 1:Solid 20 0200 5 Door 2:Solid 18 o14o 3 Door 3:Glass 40 0.290 12 Wall 2:Wood Frame,16"o..58210 00 ©0057 48 Window 2:VinylFiberglass Frame:Double Pane with Low-E 105 0.290 30 Door 4:Solid 18 240 4 Floor 1:All-Wood Joist/Truss:Over Outside Air 10 30.0 09 ©0033 oo Basement Wall 1:Solid Concrete or Masonry 1,074 00©190 0.03840Wallheight:7.8' Depth below grade:7.0° Insulation depth:7.8° Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0290 5 04002Window4:VinylFiberglass Frame:Double Pane Report date:03/16/20ProjectTitle:Foothills Builders Inc Page 1 of 10Datafilename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 john Clendon\1534 Rescheck.rck Compliance Statement:The proposed building design described here is consistent with the building plans,specifications,and other Calculations submitted with the permit application,The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requigaments lsgad ip the REScHeck Inspection Checklist, Daniel W.Ryan P.E.|Te 3/16/20 Name -Tite Signature t (J Date ENGINEERS STAMP: Project Title:Foothills Builders Inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\active Projects\1534 -DES -FHB Lot 3 John Page 2 of 10 Clendon\1534 Rescheck.rck .REScheck Software Version 4.6.4 {%Inspection Checklist Energy Code:2015 IECC Requirements:0.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. @ building envelope.Thermal envelope represented on construction documents. [103.1,Construction drawings and 1032,documentation demonstrate |403.7'energy code compliance for [PR3}¢lighting and mechanical systems Systems serving multipleidwellingunitsmustdemonstrate compliance with the IECC Commercial Prov $eaion J"|presnspecionPian Review|Plane Verified|Field Veriied|Compiies?|comments/Assumptions &neqio :103.1,Construction drawings and Ocomplies 103.2 documentation demonstrate Oboes Not fPmait Svergycodecompancs forthe {Not ObservableOotApplicable ‘Cicompties ‘Odoes Not {Not ObservableGotApplicable approved by the code official Heating and cooling equipment is Heating: ized per ACCA Manual S based Btu/hr_ on loads calculated per ACCA Cgoling.Manual)or other methods Btushr. Heating Bturhr, Cooling Btushr. Gicompiies Oboes Not (Not Observable Ginotapplicable Additional Comments/Assumptions: [E]figh impact(ier1)[Bl[medium impact (Tier 2) Project Title:Foothills Builders Inc Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Clendon\1534 Rescheck.rck Bi]ow impact (Tier 3) Report date:03/16/20 Page 3 of 10 Sealey Plans Verified+Foundation Inspection Complies?|Comments/Assumptions &Reg.iD wee iais Value [402.1.1 Conditioned basement wall Cicomplies See the Envelope Assembles [FO4 insulation R-value.Where interior R Cboes Not able for values insulation is used,verification ——e may need to occur during CINot Observable Insulation Inspection.Not Not Appiicable required in warm-humid locations in Climate Zone 3 303.2 Conditioned basement wall Bicomplies (FOS insulation installed per Coes Not°manufacturer's instructions ince Observable ONot Applicable _Conditioned basement wall fe ft ‘complies ‘See the Envelop insulation depth of burial or Ddoes Not ‘able for values. distance from top of wall (Not ObservableNotApplicable ‘A protective covering is installed Gicompties to protect exposed exterior =oes Notinsulationandextendsa:Not Observableminimumof6in.below greimumof6in.below grade.—__GiNot Applicable ‘Snow-and ice-melting system 7 Ccomplies controls installed,Oboes Not [Not ObservableBotApplicable Additional Comments/Assumptions: [1 [ign impact ier) [Bl]Medium impact (Wier?)[S]towimpact ers) Project Title:Foothills Builders Inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 john Page 4 of10 Clendon\1534 Rescheck.rck 3 [Framing /Rough-In Inspection|P19"‘Complies? Door U-factor.u Cicomplies See the Envelope Assemblies i Bboes Not table for values [Not Observable |ONot Applicable ‘Glazing U-factor (area-weighted u Tcomplies “See the Envelope Assembles “average.bees Not ‘abe for vac (Not ObservableDotApplicable Ufactors of fenestration products Ticompties are determined in accordance Oboes NotwiththeNERCtestprocedureorNotObservable%taken from the default table.FiNat apaicste '402.4.1.1 Air barrier and thermal barrier [FR23}"installed per manufacturer's @ instructions [Not ObservableCotApplicable 4024.3 Fenestration that is not site built [FR2O}is listed and labeled as meeting ARMA |WDMAICSA 101/15.2/A440e‘or has infitration rates per NFRC ee400thatdonotexceedcodeOWotApplicable limits.a IG-rated recessed lighting fixtures sealed at housingyinterior finish Oboes Not‘and labeled to indicate =2.0 cfm Not observablefeakageat75seatrtsWotApplicable '403.2.1 Supply and return ducts in attics [FR12}!insulated >=R-8whereductis inches ameter and.i FeRbwhere<3 inches.Supply and [Not Observable return ducts in other portions of Oot Applicable “the building insulated >=R-6 for diameter >=3 inches and R-4.2 for <3 inches in diameter. Building cavities are not used as Hicompies ducts or plenums.——_Lboes Not 3 LNot ObservablenotApplicable HVAC piping conveying fuids Tcomplies above 105 *F or chilled fluids Oboes Not below 55 °F are insulated to =R-IDINot Observable>Not Applicable Protection af insulation on HVAC Cicompties piping.Oboes Not [Not ObservableDotApplicable Hoot water pipes are insulated to Bicomplies BRS,Does Not [Not ObservableNotApplicable ‘Automatic or gravity dampers areinstalledonalloutdoorair [Not ObservableNotApplicable eum packer Project Title:Foothills Builders Inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Page 5 of10 Clendon\1534 Rescheck.rck Additional Comments/Assumptions: [T]Figh impact (Tier 1)[BI]Medium impact (Ter2)_[Si|towimpactriers)|Project Title:Foothills Builders inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Page 6 of 10 Clendon\1534 Rescheck.rck |insulation inspection | Plans Nerifled|FleldVerified eyAllinstalledinsulationislabeled ‘or the installed R-values provided,[Not ObservableDotApplicable 1402.1.1,Floor insulation R-value Cicomplies See the Envelope Assembles 4022.6 Elpoce net «tab forvatuen ya [Not Observable DNot Applicable Floor insulation installed per manufacturer’instructions andSubstantialcontactwiththe underside of the subfloor,or floor DiNot Observable framing cavity insulation is in ‘Onot Applicable contact with the top side of Sheathing,or continuous insulation is installed on the Underside of floor framing and extends from the bottom to the top ofall perimeter floor framingmembers. 4021.1,Wall insulation Revalue.IFthisisa)Licomplies See the Envelope Assembles 1402.2's,mass wall ith atleast %of the]Wood Ciboes Not "able forvalues /402.2.6 wall insulation an the wall Cmess El Mass ICNot ObservableTINS}!exterior,the exterior insulation ry requirement applies (FR10).C Steet C1 Steet not Applicable [303.2 Wall insulation is installed per Hicompties: IN4]!manufacturer's instructions.Oboes Not Not observableDotApplicable Additional Comments/Assumptions: [High impact (Tier 1)[iZi[Medium impact (Tier2) __[Bi]Low impact (Tier 3) Project Title:Foothills Builders inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Page 7 of10 Clendon\1534 Rescheck.rck Section 5 #|Final Inspection Provisions|PMs Nerified|Fleld Verified|Complies?|Comments/AssumptionsValueValue&Reg.iD al1402.1.1,Celling insulation R-value R R Cicomplies “See the Envelope Assemblies 4022.1,Wood (Wood Doves not fable for values eee C Steet D Steel [Not Observable trai Bot Applicable }303.1.1.1,Ceiling insulation installed per p Cicomplies 303.2."manufacturer's instructions.Boves not FIZ"Blown insulation marked every inet OncervabiSernjotObservable - not Applicable ‘Vented attics with air permeable complies insulation include battle adjacent Coes not to soffit and eave vents that extends over insulation.DNot Observable [4022.4 Attic access hatch and door [FI3?"Insulation R-value of the adjacent assembly ILnot Observable Not Applicable a402.4.1.2 Blower door test @ 50 Pa.complies [Fa7K achin Climate Zones 1-2.and boes not‘ach in Climate Zones 3-8.CNet Observeble _‘QNot Applicabl 403.2.3 tightness test result of cfm/100 ‘cfm/00~—Licomplies trae ‘cfm/100 ft2 across the system or |ft?cd Oboes Notcfm/a0 #2 without a handler @ 25 Pa.For rough-in ot Geservable tests,verification may need to INot Applicable ‘occur during Framing Inspection._}403.3.2 Ducts are pressure tested to i cfm/100.‘efmi00~~Licomplies [FIZ7)'determine air leakage with e ®does Not ether:Rough-in test:Total leakage measured with 2 iCINot Observable pressure differential of 0.1 inch Oot Applicable eg.across the system including the manufacturer's air handler tenclosure if installed at time of test,Postconstruction test:Total leakage measured with a pressure diferential of 0.1 inch9,across the entire system including the manufacturer’air handler enclosure.- [403.3.2.1 Air handler leakage designated Bicompiies [FI24)by manufacturer at <=2%of oe Odoes wot aesign airflow +-DNot Observable ONot Applicable _|Programmable thermostats installed for control of primary heating and cooling systems and | Initially set by manufacturer to code specifications. Heat pump thermostat installed on heat pumps.' Circulating service hot water systems have automatic or ‘accessible manual controls, (T]Righ impact i)[|Medium impact ( Cicomplies Oboes Not |CiNot Observable ‘Biot applicable ——Ucomplies Oboes Not [Not Observable Ginot Applicable Cicomplies: Oboes not [DNot ObservableBotApplicable er) [SB Juowimpacttrer3)|Report date:03/16/20 Page 8 of 10ProjectTitle:Foothills Builders Inc Data filename:E:\Dropbox\DWRPE Engineering\active Projects\1534 -DES -FHB Lot 3 John Clendon\1534 Rescheck.rck {All mechanical ventilation systemfansnotpartoftestedandlisted HVAC equipment meet efficacy ‘and airflow limits Hot water boilers supplying heat through one-or two-pipe heating systems have outdoor setbackcontroltolowerboilerwater "|temperature based on outdoor temperature Heated water circulation systemshaveacirculationpump.The system return pipe Is @ dedicated "return pipe or a cold water supplype.Gravity and thermos- ssyphon circulation systems are ‘not present.Controls for Circulating hot water system ‘pumps start the pump with signal for hot water demand within the ‘occupancy.Controls automatically turn off the pumpwhenwaterisincirculationloop is at set-point temperature and tno demand for hot water exists. Electric heat trace systems ‘comply with IEEE 515.1 or UL 515.Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping, Water distribution systems that hhave recirculation pumps that ‘pump water from a heated water ‘supply pipe back to the heated water source through a cold ‘water supply pipe have a ‘demand recirculation water system.Pumps have controls that manage operation of the ‘pump and limit the temperature ‘of the water entering the coldaterpipingto104°F. ‘Drain water heat recovery unitstestedinaccordancewithCSA 855.1.Potable water-side pressure loss of drain water heat recovery units <3 psi for individual units connected to one ‘or two showers.Potable water- ‘side pressure loss of drain water heat recovery units <2 psi for~_individual units connected to three or more showers. [404.1 75%of lamps in permanentFI6Pfixturesor75%of permanentfixtureshavehighefficacylamps. Does not apply to low-voltage lighting. Fuel gas lighting systems have ‘no continuous pilot light. iCompliesoesNot [Not ObservableDotApplicable HicomptiesdoesNot [Not Observable Dot Applicable HicomptiesdoesNot [Not ObservableDotApplicable Ticomplies Ciboes Not Not observable iNet Applicable DicompiiesoesNot [Not ObservableDotApplicable complies:Oboes Not [Not observable DiNot Applicable Dicompiies Ciboes not Not Observable | Dot Applicable compliesOboesNot (Not Observable GiNnot Applicable High impact (ier 1)[ai| Medium impact (Tier2) [Bl]Low impact (Wier 3) Project Title:Foothills Builders Inc Report date:03/16/20 Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Page 9 of 10 Clendon\1534 Rescheck.rck ES‘Compliance certificate posted. ‘Manufacturer manuals for ‘mechanical and water heating systems have been provided, Additional Comments/Assumptions: ‘High impact (Tier 1) Field Verified Vale ‘Complies?“Comments/Assumptions Medium impact (Tier 2) complies Oboes Not [Not ObservableNotApplicable Hicompties Oboes not CiNot observableNotApplicable Project Title:Foothills Builders Inc Data filename:E:\Dropbox\DWRPE Engineering\Active Projects\1534 -DES -FHB Lot 3 John Clendon\1534 Rescheck.rck Report date:03/16/20 Page 10 of 10 :N 2015 IECC Energy Efficiency Certificate Insulation Rating ar ‘Above-Grade Wall 0 Below-Grade Wall 19.00 Floor 30.00 Ceiling /Roof 38.00 Ductwork (unconditioned spaces):eee aaa)ecWindow0.29 Door 0.29Peeeenee Heating System: Cooling System: Water Heat Name: ‘Comments