proposedCENTER PROJECT
SERVICES
73 Sheridan Street,Glens Falls,NY 12801
Phone -518-796-2515
May 11,2020
Project #303IvanBell
IBS Septic
Queensbury,NY 12804
Re:Proposed Replacement Septic
46 Caroline Street,Queensbury,NY FILE COPY
Dear Ivan:
At your request we have reviewed your proposed replacement septic system design of theexisting3bedroomhouseat46CarolineStreet,in Queensbury.As per our conversation theresidencehasanexistingfailedsepticsystem
We have reviewed the proposed replacement septic system design and we agree that a standardabsorptionbedisacceptable.Based upon a design flow rate of 330 GPD and a percolation rate of|to 5 minutes,you will need a minimum of 367 sf of absorption area.We recommend using 15ftwideby30ftlongabsorptionbedwith3-25 ft long laterals.The absorption system can beconstructedwiththeexisting1,000 gallon septic tank,new distribution box,and 4 inch diameterperforatedpipeandstone.
Please feel free to contact me at 796-2515 if you have any questions and that you for yourassistancewiththisrequest.
Sincerel,
Thomas R.Center Jr,PE.
309.15-1-48 SEP-0257-2020
McCane,Randy
46 Caronline St
Residential Septic Alteration
Parcel ID :309
VSS GIs Program Of
Map Produced by Queensbury GIS.Ma i for Gana Reference Purposes Oty