Loading...
proposeda Lay. £ FILE COPY | CENTER PROJECTSAY(Ol oS 73 Sheridan Street,Glens Falls.NY 12801 Phone -518-796-9578 June 19,2020 Project #309GeorgeDretlos Sanitary Sewer Service Queensbury,NY 12804 Re:Proposed Replacement Septic28LerrissDrive,Queensbury,NY Dear George Mi your request,we have reviewed your proposed replacement seplic system design of theexistingJ-bedroom house al 25 Ferriss Drive in Queensbury.As per our conversation theresidencehasanexislingfaitedsepticsystem We heve reviewed the proposed ceplacoment septic system design and we aptee that a standandabsorptionbedisacceptable.Based upon a desian low rate of 330 GPD and percolation rate of\10 5 minutes,you will aved a minimum of 368 s!of absorption area,We recommend using 20Bwideby25filongabsorptionbedwith4-20 ft long laterals,The uhsomption system can beconstructedwiththeexisting£,000-xallon septic tank,now distribution hox,und 4-inch diaineterperforatedpipeandstone.Dae to the depth of the existing septic lank sin air vent wil he requiredontheendoftheabsorptionbedpipesystem Please tecl Hee to contact me at 796-2515 if you have any questions and that you for yourassistancewiththisrequest Sincerely. Thomas R.Center Jr,PLE.