proposed 40 b tri--- '
Am(if, S(du-ea-t"
FILE COPY
J
'.� TOM OF QU: '� ,
,� 1 BUILDING & .r ii. k girl
o Reviewed By. 11
Date:
/f
/ V .
Dom J .
[-r ")°
re -1 3
qt a CO \ili
\'�����
a 54)8 1 ( illj f b 1
= o o
e
5
S
J
u
CENTER PROJECT
•
SERVICES
73 Sheridan Street, Glens Falls,NY 12801
Phone-518-796-2515
June 19, 2020
George Drellos Project#308
g D
Sanitary Sewer Service
Queensbury,NY 12804 JUN 2 2 2020
tui
WNRe: Proposed Replacement Septic TO UI D NG�ECO ESRY
29 June Drive, Queensbury,NY
Dear George:
At your request, we have reviewed your proposed replacement septic system design of the
existing 4-bedroom house at 29 June Drive in Queensbury. As per our conversation the residence
has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable. Based upon a design flow rate of 440 GPD and a percolation rate of
1 to 5 minutes, you will need a minimum of 489 sf of absorption area. We recommend using 20
ft wide by 35 ft long absorption bed with 4 - 30 ft long laterals. The absorption system can be
constructed with the existing 1,250-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone. Due to the depth of the existing septic tank an air vent will be required
on the end of the absorption bed pipe system.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely;:..-- ;_ - __ ._ _ — --
11-264/4,
Thomas R. Center Jr, P.E.