Loading...
2007-716 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (DN'r` OCCUPANCY Permit Number. P20070716 Date Issued: Wednesday, June 18, 2008 This is to certify that work requested to be done as shown by Permit Number P20070716 has been completed. Location: 12 BOGART Ct Tax Map Number. 523400-290-017-0002-005-000-0000 Owner: SCHERMERHORN RESIDENTIAL HOLDINGS, L ppliic artNumber. AMEDORE LAND DEVELOPERS LLC Owner. SCHERMERHORN RESIDENTIAL HOLDINGS , L This structure may be occuppied as a: Tax Map Number. 523400-290-017-0002-005-000-0000 Fireplace By Order of Town Board @ME.- 2 Cars AttachecfkMEDORE LAND DEVELOPERS LLC TOWN OF QUEENSBURY Townhouse J 4 t Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY (2t 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070716 Application Number. A20070716 Tax Map No: 523400-290-017-0002-005-000-0000 Permission is hereby granted to: AMEDORE LAND DEVELOPERS LLC For property located at: 12 BOGART Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCHERMERHORN RESIDENTIAL I Fireplace 536 BAY Rd Suite 2 Garage-2 Cars Attached $100,000.00 QUEENSBURY,NY 12804-0000 Townhouse Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2007-716 1550 SQ FT TOWNHOUSE WITH 537 SQ FT ATTACHED GARAGE AND I FIREPLACE $270.70 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,December 04, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tent o-fQueensbttry,. `Tuesday 'December 04,2007 SIGNED BY �, �� '` 4; for the Town of Queensbury. Director of Building&Code Enforcement ___- ----------------------� ---------------------, ' - OFFICE USE ONLY 71 ' ' (CIS , 01 TAX MAP NO. PERMIT NO. PERMIT FEE 0 ; ; , 0 A o APPROVALS: ZONING TOWN CLERK 0 , , / r-------------------------------------------------------- ----------. 1-------__-----_______. APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: INSTALLER: ADDRESS:!1� ADDRESS: PHONE NOS. 5 �� PHONE NOS. LOCATION OF INSTALLATION: NO.OF RESIDENCE INFORMATION: BEDROOMS YEAR BUILT X COMPUTATION= = TOTAL DAILY FLOW GARBAGE GRINDER 1980 or older X 150 gallon per bedroom = INSTALLED? 1981 -1991 X 130 gallon per bedroom = SPA OR HOT TUB 1992-present X 110 gallon per bedroom = INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: Flat rolling Steep slope %Slope ✓ SOIL NATURE: Sand Loam Clay Other ✓ GROUNDWATER: At what depth? ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? ✓ DOMESTIC WATER SUPLY: Municipal Well (If well: Water supply from any septic system absorption is ft.) ✓ PERCOLATION TEST: Rate is per minute per inch. (Test to be completed by a licensed professional engineer or architect.) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). TANK SIZE: GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ft. Each trench X ❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size? ❑ ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? ..... ......... ......... ......... ......... ......... ......... .................::::...... ......... ......... ... i NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. codes@aueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensburv.net Signature of Person Responsible Date Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury,NY 12804 B 5-LGL 6/06 716 Check A, Residential Plan Review: One& Two Family Dwellings YJN/N (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans undation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls a Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width S it Run and Rise Winder Run and Rise piral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. k -1"/ Ed andrails More Than One Riser On Open Sides JR-ailing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation G age Floor Sloped If Attic Access Roo over 30"—22"x 30"/Crawl Spaces 18"x 24"Access arbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ..._ ....._.I. OFFICE USE ONLY r....... ,.. TAX MAP NZ PERMIT NO. 7l" FEES: PERMIT �S " RECREATION ENGINEERING ), (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANC OF A VALID PE MIT FOR CONSTRUCTION. APPLICANT/BUILDER. OWNER: ADDRESS: /ftGt,,P.a�t�-, Al j 44 O� ADDRESS: PHONE NOS. ( S — /OHO PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: HONE: LOCATION OF PROPERTY: 2CIA4C SUBDIVISION NAME: dAy, I J�,�� �( ULc�'►�- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z r O APPLY TO YOUR ZO 1= 0 00 � d O r _ PROJECT O r -1 - w ¢ a- 0 0 � o LL 'L Q � r O z_ z ¢ Q � N � Our- OLL nL ca SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS„) TOWNHOUSE I/ l S O 4n Z 0 6 -1 Z v BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: I6oi 000 FUEL TYPE: HEAT TYPE: A- 6c,,O *HOW MANY FIREPLACE(S):__J _AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? 140 IS THIS A HISTORIC SITE? � PROPOSED USE OF BUILDING OR ADDITION: �s u:�b �"��^-` J. Z � ""'�""' 722w►��v� *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbut-1/ • CommunitU Develovment Office 0 742 Bat/ Road. nuearr.ahvry MY I)RnA ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have remand agre the e. Signed ` Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ....................... / I , , , , o Permission is hereby granted to the above This application / proposed action described 00, o Applicant to erect or alter the building ; herein is found to be in accordance with the 01 o described herein in accordance with said zoning Laws of the Town of Queensbury. 01 o Application: ; ; 10 / 0 0 0 0 1 , /1 / , / , , , , , / , I 10 BUILDING & CODES APPROVAL ZONING APPROVAL ; 0 ' , 0 11 DATE ' % DATE QUESTIONS? CALL 761-8256 OR EMAIL codes0clueensbury.net Office Use Only VISIT OUR WESSITE FOR MORE INFORMATION rv. Operating Permit Issued: Yes No www.gueensbu net Occupancy Type: Construction Classification; ��C; Assembly Occupancy Limit: Special Conditions: Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 /-,-j /r(o Queensbury Building & Code Enforcement - Reside al Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: ) am/pm Date Inspection request received: Inspector's Initials: NAME: APERMIT#: , LOCATION: DATE: TYPE OF STRUCTURE: ;, Comments: Y No WA 4' Building Number Address visible from road Chimney Height 1'13'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,ponlies 36 inches or more Handrail Termination at Newell Post or Wall r Interior/Exterior RailkXW 34 inches to 38 inches or Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade �J Interior privacy/en/doors!main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/WhVow in stairwells safe Interior Smoke ors/Cafion oxi Every level: EvejY Bede de ('-�' ' �•�'Y Outside every bedroom�frea: l Inter Connected: V Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 .ft.-150 .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation Insulation Floor truss,draft stopping finished basement 1,000 sq.It. Emwgency egress below gradex Gas Furnace start-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater o Low water shut-off bolter Relief Va s installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum or- Basement stairs dosed rise>4 inches VY Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure Final Electrical ES Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Se S tern/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 T /Permanent LABuilding&Codes Forms\Suilding&CodesUnspection Fomhs\Resident!W Final Inspection Form_revised_10D405.doc,Revised January 7,2008 Queensbury Building & Code EnforceZnt - R ri/ential Final Inspection A • Office No. (518)761-8256 Arrive: am/pm rt:�anVpm Date Inspection request received: Inspector's Initials: NAME: Vic`% PE IT#: _ LOCATION: DATE: TYPE OF STRUCTURE: Comments" Yes No NIA 4' Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof /Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior RailirW 34 inches to 38 inches Deck Brae /Handicapped Ramp Com Kant Grade away from foundation 6 inches with 10 feet 6 inch clearance to siR plate Gas Valve shut-off exposed/regulator 18 inches move grade Interior privacy I trim/doors I main entrance 36 inches Bathroom/Kdchen watertight S /Window in stairwells safety g!@F�m Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Conned: Battery badku : Attic access 30 inches x 22 inches x 30 inches(height)in acoessible area Crawl Spaces 18 inch x 24 inch acoess,1 sq.ft:i 50 sq.ft.vents BaUhroom Fans,if no window Plumb'Plumbina fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within tine of site Oil Furnace shut-off at entrance to furnace area FumaceMot Water Heater operaft Low water shut-off botier Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inc es Garage Floor Pft hed Garage fireproofing/%hour fire door/door closer Duct work Sealed propedy Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built SelAic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certffmadon,if required Okay to issue C/C or C 10 Tern /Permanent LABuilding&Codes Forms\Suilding&Codesllnspecion Forms\Residential Final Inspection Form revised_100405.doc;Revised January 7,2008 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: X�' NAME: _ _ LOCATION: Z PERMIT#: Final Survey Plot Plan Approved , Denied The attached final survey has been received by the Dept.of Community Development. Upon review tbc- s9yej has b OJI/i - Craig Brown,Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc Town of Queensbury Fire Marshal low 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Iieaort Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# 0-1 Schedule Inspection Time anytime Inspector Name AdW*§W1*Address Appliance Manufacturer. Model# �T((�2m �C Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection 00, Clearances to Combustibles (all sides) 000, Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White—Building Dept. l �— Yellow cm4ter Pink—Fire Marshal Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: j '`.am/pm 742 Bay Road, Queensbury, NY 128N Inspector's Initials: '-A AA 1 NAME: PERMIT#: LOCATION: INSPECT ON: �- TYPE OF STRUCTURE: Y N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping (2ml5minutes Insulation esidential Check/Commercial Check Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Once No. (518)761-8256 Date Inspection request received: 0 g, Queensbury Building &Code Enforcement Arrive: am/pm Depart: a /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: I 1'\ NAME: �� PERMIT LOCATION: ��INSPECT ON: TYPE OF STRUCTURE: f� 9ti. �a -� 4E-�J Y N WA COMMENTS: ming Attic Access 22"x 30" minimum Ja=/Headers /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/W 16 gauge 8 16D naus each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 s#grade LABuilding&Codes Foms-OMBuilding&CodesUnspection FonnsTraming Fib Inspection Report.doc Revised January 7,2008 /-.5 %rV Framing / Firestopping Inspection Rep6rt Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart�'`�am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: APERMIT# r 74 LOCATION: ® INSPECT ON: =� " TYPE OF STRUCTURE: Y N WA Framing COMMENTS: 'Aftiess 22" x 30" minimum Jack 6juds/Headers (B-rati—ngl Bridging ers Jack Posts/ ain Beams Exteriors properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing ' _ Headroom 6 ft. 8 in. t Notches/Holes/Bearing Walls ,w Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wail 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'A inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fonns-OLDSuilding&CodesWupection FonnsTran"Firestopping Inspection Repon.doc Revised January 7,2008 Rough Plumbing / insulation insp ction Report Office No. (518) 761-8256 Date Inspectio,9.request received: Queensbury Building & Code Enforcement Arrive: -0 O5 am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Ins is Initials;k P c/ NAME: PERMIT#: 07_7/ LOCATION: Z 9 INSPECT ON: TYPE OF STRUCTURE: -� Y N/A Bal Plumbingfhlail Plates Plumbs /Vents in Place IV 10- I %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every_100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/ Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly 1 No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 �e Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Ll Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: 7 . INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing D , ffy ' place o do ppr g Fo n Wat r Footing Drain Daylight or Sump Footing Drain Stone: 1 inch width inches above footing mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM t� f� J Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection r ed: Queensbury Building &Code Enforcement Arrive: a part: ;2D a 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: '�_ PERMIT LOCATION: rlG INSPECT ON: - - TYPE OF STRUCTURE: Framing Y N WA COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2 w 16 gauge 8 16D nails each side Draft st sq. ft. floor trusses r Botts ,. or less n center Ice and water shi I ches from wall Fire sepa Mon 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (" 5.7 sf above/below grade 5.0 s#grade LABuilding&Codes Forms-01-MBuilding&CodesUnspection FornisTraming Firestopping Inspection ReporLdoc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: AZA Queensbury Building&Code Enforcement Arrive: am/p Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: ►A----6 M PERMIT#: �✓ �` LOCATION: L{17- 17 Q rP r INSPECT ON: _ TYPE OF STRUCTURE: Comments Y N N/A ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Doting Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials` NAME: PERMIT#: ®' l� LOCATION: INSPECT ON: j o TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Foo ' g Drain Daylight or Sump F tin Drain Stone: 1 inch width 2 f 1 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM ll , Foundation Inspection Report Office No.(518)761-8256 Date Inspectio request received: Queensbury Building&Code Enforcement Arrive: : am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect 's Initials: NAME: ! PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing F ting Drain Daylight or Sump Doting Drain Stone: 12 inch width A , 6 inches above footing 6 mil po1 for wet areas under slab / Backfill Approval r Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection ForinsWoundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: ----! ,Xc s Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initialmc NAME: �3 PERMIT#: LOCATION: INSPECT ON: Mom TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place oundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing V/ 6 mil poly for wet areas under slab Backfill Approval T / Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 62- :ace /v _/? , r� Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ptn� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: f - 7 NAME: PERMIT#: CIO LOCATION: INSPECT ON: / — — TYPE OF STRUCTURE: Comments, Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing J for 48 hours follonming the placement 1 of the con 4 Materi for this on site. Foundati /Wallpour Reinfo ft m lace Footing Dow s or Keyway in place FoundatlQu,6ampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm, Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ��'/ NAME: L PERMIT#: 7, 7 Cr LOCATION: INSPECT ON: ® O TYPE OF STRU TUBE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforce tin Place Foot!j Powels r Keyway in place Founda pproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm . 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: -j ,` L"'- NAME: A)"nL, PERMIT#: V LOCATION: INSPECT ON: t TYPE OF STRUC Comments Y N N/A (IF:ootings �` Monolithic Slab Reinforcement in Place; ��� L The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM t 6 Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Townhomes at The Havilands Report Date: 11/07/07 Data filename: K:\RESCHECK\havilands\12Bogart.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Multifamily Heating Type: Non-Electric Glazing Area Percentage: 7% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 12 Bogart Ct. William Balogh Queensberry,NY 12804 Amedore Homes Inc. 1900 Western Avenue Albany,NY 12203 518-456-1010 wbalogh@amedorehomes.com Compliance:PaSSeS maximum uA:493 . . de U Cavity �.. Ceiling 1:Raised or Energy Truss: 1676 30.0 0.0 54 Wall 1:Wood Frame,16"o.c.: 1602 19.0 0.0 86 Window 1:Wood Frame:Double Pane with Low-E: 109 0.350 38 Door 1:Solid: 56 0.280 16 Door 2:Glass: 11 0.310 3 Basement Wall 1:Solid Concrete or Masonry: 1388 11.0 0.0 96 Furnace 1:Forced Hot Air:90 AFUE Air Conditioner 1:Electric Central Air: 13 SEER The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer Company Name a Townhomes at The Havilands Page 1 of 4 REScheck Software Version 3.7.3 Inspection Checklist Date: 11/07/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/6.0'bg/7.8'insul,R-11.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.280 Comments: ❑ Door 2:Glass,U-factor:0.310 Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:90 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Townhomes at The Havilands Page 2 of 4 r ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to.R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Townhomes at The Havilands Page 3 of 4 r 4 ' Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5'to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Townhomes at The Havilands Page 4 of 4 MAP REFERENCE: HAVILAND ROAD 5UBDIV1510N BY VAN DUSEN + 5TEVE5 DATED OCTOBER 14. 2005 LAST REVISED MARCH 1G. 2000 LOT 4 cn O H.O.A. x rn a LOT 5 AREA 11,658.51 sq. ft. 0.27 acres / n O TILITIE>y 2 STORY WOOD FRAMED O/ TOWNHOUSE / GRUSHED STONE STEPS p2 f DRIVE 0 65- ►•""' I / 163.51 o ne/ N887°0 W LOT 6 2 STORY WOOD FRAMED TOWNHOUSE LOT 11 LOT 10 LOT 9 E...� LOT 7 LOT 8 Date; June 18, 2008 •UNAUIHQ412ED ALTERATION OR ADDITION TO A SURVEY & MAP VIOLATION OF A LICENSED LAND SURVEYORS SEAL IS A Map of a survey made for Scale 1'=z0' NEW YOM of STATE TION nos.sua-awsTON z OF THE S NEW YY C STATE FROM TH ON LAW. 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY NARKED KITH AN ORIGINAL Of THE LAND SURVEYORS Patricia Snyder SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.' ._ "CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE PATH THE Land Surveyors By THE NEW PRACTICE A FOR`�°SURVEYORS ° Lot # 5 RY THE NEW PORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS.SAID CERTIFICATIONS SHALL RUN ONLY TO THEHIS PERSON FOR WHOM THE SURVEY IS PREPARED,AND Haviland Road Subdivision ON NO AN LENDING TO THE TITLE CONPLIST GOVERNMENTAL SHEET 1 OF 1 169 Haviland Road Queensbury New York 12804 AGENCY AND ITHE LENDING LISTED HEREON,AND Town of Queensbury, Warren County, New York � TO THE ASSIGNEES OF THE LENDING INSTiN1)ON.' (518) 792-8474 New York Lie. No. 50135 _ Snyder NO. DATE DESCRIPTION DWG. NO. 0514G_5