Loading...
2007-722 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20070722 Date Issued: Thursday, July 10, 2008 This is to certify that work requested to be done as shown by Permit Number P20070722 has been completed. Location: 8 POLLAZZO Ct Tax Map Number: 523400-290-017-0002-025-000-0000 Owner: SCHERMERHORN RESIDENTIAL HOLDINGS, L Tax Map Number: 523400-290-017-0002-025-000-0000 Applicant: AMEDORE LAND DEVELOPERS LLC Owner: SCHERMERHORN RESIDENTIAL HOLDINGS, L This structure may be occupied as a: Tax Map Number: 523400-290-017-0002-025-000-0000 Fireplace By Order of Town Board affw&- 2 Cars AttachedkMEDORE LAND DEVELOPERS LLC TOWN OF QUEENSBURY Townhouse Issuance of this Certificate of Occupancy DOES NOT relieve the ; property owner of the responsibility for compliance with Site Plan, ` Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070722 Application Number. A20070722 Tax Map No: 523400-290-017-0002-025-000-0000 Permission is hereby granted to: AMEDORE LAND DEVELOPERS LLC For property located at: 8 POLLAZZO Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: AMEDORE LAND DEVELOPERS L Garage-2 Cars Attached 8 POLLAZZO Ct Townhouse $100,000.00 QUEENSBURY,NY 12804-0000 Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2007-722 1550 SQ FT TOWNHOUSE WITH 537 SQ FT GARAGE $270.70 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, December 10, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the o tluee ry P wRday, December 10, 2007 SIGNED BY for the Town of Queensbury. Director of Building&Coctknforcement 0?-- 7z-Z--" Check Residential Plan Review: One& Two Family Dwellings Y!N/N/A I/ Full sets of plans Over 1,500 sq. ft. —Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: indow Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq. ft. Grade,5.0 sq. ft. 2 "(h)x 20"(w)min. 'Wax.Height above floor idential Check Paperwork Compliance and Inspectors Checklist: OK proofing/Waterproofing Materials On Plans oundation Drainage On Plans,if required " p in 10' Exterior Grade ng Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where uired ce and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors tairway Headroom 6' 8'All Stairs 36"Width f tair Run and Rise , Winder Run and Rise Spiral Not Allowed From 2d Story oke Detectors Battery Backup and Proper Location B oom Fixtures Proper Clearance al Width,36"min. ails More Than One Riser On Open Sides 'ling and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation vl Garage Floor Sloped Attic Access f over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ---------------- --- - --- Conur3unity Development Office � owii> o,� Queerrsburu • 742 hai/ Road • Queens1mry, \leer York -12804 1 l ai7hpa R1ba, Executiz°e Director• Do,»:' Hahn, Director of Buildirra & Codas rain Brown, —Iunitto Administrator _ 1 ---------------- --- -- -- BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS REQUIRED ACTUAL ACTUAL LIGHT REQUIRED SQUARE FOOT AREA OF ROOM IN LIGHT VENTILATION HABITABLE ROOM SQUARE FEET B"OF ROOM AREA SQUARE VENTILATION-4% SQUARE OPENING FOR REMARKS FOOTAGE OF ROOM AREA FOOTAGE EGRESS i I� 1 QUESTIONS 7 CALL 761-8256 OR EMAIL i codes&bgueensbury-net VISIT OUR WEBSITE FOR MORE INFORMATION www- net-net B 10-LTR 11-20 _ _ _ °;:- ___ Community Development Office ; TOYU11 0f Queen-sburl/ • 742 Bay Roat i • Qitet t=burL/, Nei,' � ,� 1. •� ?�l)1 , Alarililn Rt b , B.recutiue Director • Daulii Hatiti. Director f ButLtirtg a CLJ; ; Cram Brorori. Zortino Admlmstrator WIND 01 V S CHED LIL E JOB SITE/ADDRESS. CJ?CkjQt 9 �o GT DAT=: OWNER: APPLICATION No .- UNIT OR CLEAR WINDO�,%/- CLEAR NO. OR WINDOW STOCK ROUGH ROl GH SO FT OPENING WINDOW SO FT )PENING SPECIAL HARDWARE OR FACTURER MANUFACTURER NUMBER OPENING OP�flItJG EGRESSiCLEAf'. HEIGHT LETTER MODELTl'PE VENT VIDTH IN INSTRUCTIONS ON PLAN NAME CALL H' Fi'E'ft;f9T OPENING IN SIZE Wj�olk�- _W i ba INCHES h INCHES C e It a. D i� H ISq 'A I / q 7,32- �(� 'A tie lac, I� 375 14 �3, g U. 33 f d a b lq - _ T _ direMarshal's Office f Queensbary- 742 Bay Road - Queer sour y, ivew Vork -12oll4 ................ Nlichact J. Palmer, Fire Mandial- Gary Stillman, 0epity Fire Alarshal f Eb 0 209B `TOVIN- F- 6 Rt1RY APPLICATION FOR FUEL BURNING APPL BU DING & CODES Application is hereby made to the Building&Codes Office for the issuance of a Building& Use Permit pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply with all applicable laws,ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT'NOTE TO APPLICA : ROUGH-IN AND FINAL INSPECTIONS ARE RECA)IRED. OWNER: /,A �11_0 441� INSTALLER/BUILDER: r ADDRESS:_/Cf '� ADDRESS: nuplcs PHONE NOS. q5-(-o- (o I PHONE NOS. LOCATION OF PROPERTY. SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: A, C PHONE: K5_2 L76 ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: P G7lG ----MODEL NO. LISTED BY: NUMBER: QUESTIONS? CALL 7614205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshaIg—bg ueens bury.net MASONRY" CHECK ONE ✓ VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES wwwauftoRtAntag! FLUE CHECK ONE ✓ DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY CHIMNEY MATERIAL CHECK ONE ✓ WALL LINER V/ **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO ADDITIONAL NOTE., CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. -----OFFICE - " OFFICE USE ONLY--- NLY______________________.,___% ---------------------- 1 ' r 1 1 ' 1 TAX MAP NO. PERMIT NO -' (' 'PERMIT FEE A APPROVALS: ZONING TOWN CLERK ; --------------------- APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. Pa� 4e�5 OWNER: 6/'-�— INSTALLER: ADDRESS: / ADDRESS: PHONE NOS. 'MA/ ��C'S 2�g� PHONE NOS. LOCATION OF INSTALLATION: �'�E�/f NO.OF RESIDENCE INFORMATION: YEAR BUILT BEDROOMS X COMPUTATION= = TOTAL DAILY FLOW GARBAGE GRINDER 1980 or older X 150 gallon per bedroom = INSTALLED? 1981'-1991 X 130 gallon per bedroom = SPA OR HOT TUB 1992-present X 110 gallon per bedroom = INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: Flat rolling - Steep slope %Slope ✓ SOIL NATURE: Sand Loam Clay Other ✓ GROUNDWATER: At what depth? ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? DOMESTIC WATER SUPLY: Municipal Well (If well: Water supply from any septic system absorption is ft.) ✓ PERCOLATION TEST: Rate is per minute per inch. (Test to be completed by a licensed professional engineer or architect.) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). TANK SIZE: GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ft. Each trench X ❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size? ❑ ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? t Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. codes@queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensburv.net Signature of Person Responsible Date Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury,.NY 12804 B 5-LGL 6/06 1 QFFICE USE ONLY TAX MAP NO. PERMIT NO. r.. FEES: PERMITRECREAATION ENGINEERING (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VAL1 PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: '�nnn OWNER:z�j(,kp ADDRESS:l oo oy,,, ,- d4 F/'� �ZZ�� ADDRESS: PHONE NOS. �t� �t 5(s'- (a PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: LOCATION OF PROPERTY: _ � d I al16zZU Cow SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z 0 O a UJ w APPLY TO YOUR O �- O O p = PROJECT t= O � -j ti W Q O 0 z_ LL z Q Q c- Ci NU) 0 u- O LLLL GL = «S SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) l� r TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: ( ) QOr� FUEL TYPE: t��.-� /(__c� a *HOW MANY FIREPLACE(S):��_AND/OR WOODSTOVES(S): HEAT TYPE: lS� ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? X(5 IS THIS A HISTORIC SITE? Wc � PROPOSED USE OF BUILDING OR ADDITION: *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3ArjL t 1-05 Town of Qu eensbuYU Coyi2yYttlnitl! DP2)P1()rMPf1t (ifF(r'v • 7A.? Rni Rnnd (7e,oav,cl7a,r+, 1XTV 97411A ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? a ARE THERE EASEMENTS ON PROPERTY? No I acknowledge no construction activities shall be co menced prior to issuance of a valid permit. I certify that the application, plans, and sup orting materials are a true and complete statement/description of the work propose , that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I ackno ledge that prior to occupying the facilities proposed, I or my agents will obtain a certif cate of occupancy. 1 also understand that I/we are required to provide an as-built survey y a licensed land surveyor of all newly constructed facilities prior to issuance of a certificat of occupancy. I have read and agree tot a above. Signed Director, of Building & Codes: 761-8256 (for question regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regar ing required permits, the permit process, application requirements or to schedule an appointor nt) ................................................... .._.._._.._............ I , 11 Permission is hereby granted to the above S his application / proposed action described Applicant to erect or alter the building erein is found to be in accordance with the described herein in accordance with said oning Laws of the Town of Queensbury. Application: ; ; 00 , / , I , BUILDING & CODES APPROVAL 0 11ONING APPROVAL 11 , , 11 DATE DATE 11 ...................... ,..,..,..,......................................... QUESTIONS? CALL 761.8256 OR EMAIL codes@—Queensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes q0 www.gueensbury.net Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbun • Community Development 0 ce • 742 Bay Road, Queensburly, NY 12804 Queensbury Bul ding & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: arn/pm Date Inspection request received: Inspecto s initials: NAME: PERMIT#: "' LOCATION: DATE: TYPE OF STRUCTURE: ' Comments: Yes A No NIA 4' Bukling Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location01 Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete PlaWrm at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guam at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate VA Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/tram/doors/main entrance 36 inches Bathroom/ICbchen watertight Safety glazing/Window in stainwelis safety glazky Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency below grade Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Fumace/I-W Water Heater operaft Low water shut-off boiler Relief Va s installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitcied Garage fireproofing/%hour fire door/door closer Dud work Sealed Gas Loge in Sealed or G re Final Electrical Final Su Plot Plan Arc Fault Breaker in Bedrooms F.Flex Gas Pipe Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance Muired Flood Plain Certification,if requWed Okay to issue C I C or C/O Temporary/Permanent LABuilding&Codes FormsTudding&CodesUnspedion Forms%Residential Final inspection Form revised_1004054m Revised January 7,2008 MAP REFERENCE: HAVILAND ROAD SUBDIVISION 0� BY VAN DUSEN&STEVES DATED OCTOBER 14, 2005 LAST REVISED MARCH 16, 2006 0 98 �O 0 4� 13 a x a �a LOT #26 cv, E p GOV 011155 09c� N$ 121 •58, `� a .p co c O off' 2 5 FR M�� WO00`9 0V5E J LOT #27 N O / \ 0 Z9.a c LOT #25 8,673.54 sq. ft. 0.20 acres / A\ 0 / 03 LOT #24 •o coo o / 20' DRAINAGE & ACCESS / EASEMENT �Al � LAN Date, June 23, 2008 a Du S � ,UNAMORIZED ALTERAATION OR AMIM TO A SURWY Map of a Survey made for MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A S c a t e 1'=2 0' & NYON STATE IONEDUCATION ATIO SUB DIMSION z�, William C . C a s p e r s o n NEV(Ew iroac STATE EDucAnoN uw.• 'ONLY COPIES ORIGINAL THE ORIGINAL OF SURVEYORS SURVEY Steves MARKED TNTH AN ORIGINAL OF THE LAND SURVEYORS SEAL SNAIL BE CONSIDERED TO BE VALID TRUE COPIES.' 'CERTIFICATIONS WAS PREPNOfCARED HEREON DANCE THAT Mar y J. C a s p e r s o n Tws SURVEY WAS PREPARED w ACCORDANCE MNH THE Land Surveyors BY 1WOnIIN NECODW R PRACTICE A FOR LAND SURVEYORS PROFESSIONAL ADOPTED Lot #25 SHEET BY 7HE NEW YORIC STATE ASSOCIATION OF PROFES90NAL LAND SURVEYORS SAN)CERTIFICATIONS SHALL RUN ONLY TO THE PERSON FOR W4OM THE SURVEY IS PREPARED.AND �7HE 1 1 OF 1 ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL HaVlland Road Subdivision 169 Haviland Road ueensbur TO Y,�GN`°'�ITHE LE OI IN "°�°"'""°Q y New York 12$04 1 7/02/08 TITLE COMPANY (518) 792-8474 New York Lie. No. 50135 Town of Queensbury, Warren County, New York Amedore NO. DATE DESCRIPTION DWG. NO. 0514G-25 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 r Date received: NAME: , LOCATION: PERMIT#: T � , Final Survey Plot Plan AwDroved Denied The attached final survey has been received by the Dept.of / Community (/ Development. Upon review the survev has b' C rown,Zoning Administrator Notes: ,1 L:\,.SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey Zoning Adminishatordoc k; Rough Plumbing / Insulation Inspecti n -Report Office No. (518) 761-8256 Date IInscti "uest received: Queensbury Building & Code Enforcement Arrive - T am/p Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Ins Initials: r NAME: - PERMIT #: '"t;F LOCATION: �' INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping ea r i 50 P.S.I for 15 minutesJ � Insulation esidential Check/Commercial Check or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 i_1_/� �- Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request receiv Queensbury Building &Code Enforcement Arrive: am/ rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT# 0 " 7 I-- LOCATION: INSPECT ON: G TYPE OF STRUCTURE: N N/A COMMENTS: aming Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers ��a J i V& Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y w 16 gauge 8 16D nails each We Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side h inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (M 5.7 sf above/below grade 5.0 sf grade � / G 1. LABuilding&Codes Forms-01-Muilding&CodesUnspec*ion FornisTraming Firestopping Ins)sdion ReporLdoc Revised January 7, !/ Jt,p2 Iz7 06 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: APERMIT#: - 2 LOCATION: G INSPECT ON:-7&—. - — TYPE OF STRUC Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width ting 6 mil poly for wet as under slab Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LABuilding&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM ( r d GCS) / -3 WKeSddu Rough Plumbing / insulation lnspecti n Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: etQj am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ` NAME: &-Jorc— PERMIT#: � LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head . . tx 1 <�higconnection for 15 minutes Pressure Test upp Piping Air/Head 50 P.S.1 for 15 minutes Insulation/ Residential Check/Commercial Check I - Tyvikk or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation if required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: I/VP- Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building S Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: I" PERMIT t. LOCATION: -> INSPECT ON: TYPE OF STRUCTURE: �vU�3 Framing Y N WA COMMENTS: Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headman 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft st?R0pg.J,000 sq. ft.floor trusses 6 ft. less on center elc7�76;andwater shie 24 inches from wall TZiaLsen1, 2, 3hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side i4 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fo►ms-01-Muilding&CodesUnspection FomtisTraming Firestopping inspection Reportdoc Revised January 7,2008 I/0 co 6bl�c Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p I_ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials NAME: l� PERMIT#: _ LOCATION: INSPECT ON: TYPE OF STRUC Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Founda on Waterproofing Footing Drg' r Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil PO1 for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /O—1,7 '4alzsc, 3 X Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: /(/)' -�7 LOCATION: INSPECT ON: — TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the conc Material r this se on site. Foundatio /Wallpour Reinforcem Footing o e or Keyway in place Foundation ampproofmg Foundation Waterproofmg Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /U /2_ 0,�2w,es Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:_ I NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials r is se on site. Foundation Wallpour Reinfor, in Place Footiii�Dowel or Keyway in place Foundati pproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast J Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date InspeotiPnequest received: Queensbury Building&Code Enforcement Arrive: .0 5 am/pmDepart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: R NAME: tML�afZC PERMIT#: 2' LOCATION: INSPECT ON: 1 //9 d TYPE OF STRUCTURE: Comments Y N N/A Footings � � ���� �(� � ✓ ' 1� J Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pmj pp Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: r ''` NAME: PERMIT#: 7 7 LOCATION: 4t_.A'Zr2-b INSPECT ON: _ F © 3 TYPE OF STRUCTURE: Comments f YA N/A Footings Piers Monolithic Slab Reinforcement in Place �y / Y The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report-doc Last printed 12/20/2005 9:24:00 AM (IM) Z —1/ ZIE-jf5- 417 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: ks, Zjr-Cl PERMIT#: 2 LOCATION: ck INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footin Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofmg Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM SL-750TR-D 36" TOP/REAR VENTED DIRECT VENT GAS FIREPLACE SL-750TR-D Direct Vent Unit $1,610 $2,136 SL-750TRLP-D Direct Vent LP Unit $1,610 $2,136 Note:Includes standard top and bottom louvers Pricing Includes Horizontal Installaion Pricing Valid from March 2005 thru February 2006 ----------- FecWbwes, Fr 3 e4A,P,¢iZk___-_------ • Top/Rear Venting Options • Installation Versatility • Slim Dimensions 161/4"Deep with 4"x 6-5/8" • Easy histallation with Little or No Chase Required Venting Top/5"x 8-5/8" Venting Rear • Ceramic Fiber Split Style Logs • The Most Realistic Burn Available • 13,500-23,000 BTU Input/Hr.(NG) • Generous Flames 13,500-23,000 BTU Input/Hr. (LP) • High Thermal Efficiency • Heater Rated-Keeps You Warm&Cozy • Sealed Combustion Chamber • Works in Negative Pressure Situations&No Cold Drafts • Wall Switch Wire Provided • Easy Installation • Optional Polished Brass or Brushed Nickel Trim • Attractive Finishing Trim • Optional Decorative Front • Create Your Own Elegant Look • Optional Ceramic Firebox Refractory • Enhanced Realism u� •s usTcv • Safety Tested,Approved for Installation in Aftermarket Mobile Homes&UL Listed to UL307B -------------- --------- ---- 45-1/16 51-118 [1145] 39-r/8129 81 36-9/16 10141 (929] 248 22-3/16 [563.6] xI- 30-3/4 [650] [7811 (240] 12413 16-5/16 [414-3] 15-3/8 1/2 [391] [12.7] 403] (222] [416] r�l [165][165] 3-5/8 Z [1618] [93q 31-13/16 Vr [809] J37-7/8 0 20-3/4 [962] 1oiq 34-/8 (5 7] 3-9/16 8 2-3/16 [879] [90.5) 0 (55.6] II GAS LINE-7h�—19181 —►� 6-7/8 ACCESS ACCESS 6 (918] [175] ACCESS [152.41 41 11041] J SPECIFICATIONS Model Height Front Width Back Width Depth [972] GlasSL-750TR-D Sizes BTU Input 1416]8 Actual Framing Actual Framing Actual Framing Actual Framing Inches 37-7/8 38-1/4 40-7/8 42 30-3/4 42 16-3/8 16-3/8 36 x 24-3/4 Reference dimensions only. We recommend measuring individual units at installation. 2 [1067] February 2004-Rev A HEAT-N-GLO L-4 Permit# Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Townhomes at The Havilands Report Date: 11/09/07 Data filename: K:\RESCHECK\havilands\8palazzo.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County, New York Construction Type: Multifamily Heating Type: Non-Electric Glazing Area Percentage: 8% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 8 Palazzo Ct. William Balogh Queensberry,NY 12804 Amedore Homes Inc. 1900 Western Avenue Albany,NY 12203 518-456-1010 wbalogh@amedorehomes.com . :liance:;Passes Maximum UA.494 Your Ho .0mm ,ffl- mm��w Ceiling 1:Raised or Energy Truss: 1676 30.0 0.0 54 Wall 1:Wood Frame, 16"o.c.: 1602 19.0 0.0 85 Window 1:Wood Frame:Double Pane with Low-E: 100 0.350 35 Door 1:Solid: 56 0.280 16 Door 2:Glass: 24 0.310 7 Basement Wall 1:Solid Concrete or Masonry: 1388 11.0 0.0 96 Furnace 1:Forced Hot Air:90 AFUE Air Conditioner 1:Electric Central Air: 13 SEER The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer Company Name ��• 8 �11n ri I� d � Sql Townhomes at The Havilands Page 1 of 4 CEScheck Software Version 3.7.3 �j( Inspection Checklist Date: 11/09/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/6.0'bg/7.8'insul,R-11.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.280 Comments: ❑ Door 2:Glass,U-factor:0.310 Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:90 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air: 13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Townhomes at The Havilands Page 2 of 4 ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. . Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Townhomes at The Havilands Page 3 of 4 Y Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1,5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Townhomes at The Havilands Page 4 of 4