Loading...
as built KEVIN L. HASTINGS, P.E. CONSULTING ENGINEER Mailing Address: 3 Jackson Avenue South Glens Falls,New York 12803 Tel: (518) 222-1338 �� June 3 2020 -t'L z Mr. Charles Dyer 013 ;, c. Building Inspector C 742 Bay Road t--i r � ' fa) 0; . Queensbury,New York 12804 —I co•f ' Re: 523 Ridge Road L.--- Sewage Disposal Field-Engineer's Certification SC-_-Q- 07-16-- Z02C Dear Mr. Dyer, The construction of a replacement sewage disposal field for the residence at 523 Ridge Road (TM#297.14-1-5)has been completed. The installation was completed by Lou DeRidder of Morning Star Septic Service,who was also present for the final inspection. As the design professional of record,I certify to the following statements: 1. Engineering design report with specifications and details were prepared May 11, 2020 by Kevin L. Hastings, PE for a 3 bedroom maximum(330 gpd) single family home; 2. Design documents were compliant with the Town sanitary health codes, and the NYS Health Department Appendix 75-A,as applicable; 3. Field observation of constructed works on June 1, 2020,by Kevin L. Hastings,PE and prior to earth backfill of trenches and structures; 4. Completion of the work appeared to be in substantial conformance with the design engineering report,with the following exceptions: - final turf stabilization& lawn maintenance to be completed in 2020 by owner. The as-built schematic of the replacement sewage disposal field with location ties to the dwelling is attached for your records. If you have any questions 2 ikegQicNEW, . .s al information,please contact me immediately. Sincerely, c, r t, tdim. 161i .•-• }.10 illit-r..0115,k) 04 Kevin L. Hastings,PE9 j��' 'P°FESS1(#' __ ___ �__ __ _._ ;; 523 Ridge Road . ._,, i (T) Queensbury, NY 1 y I. f/ c a K� rTh "'- ' ' `It I , } - ' ,a O i t O CLrEnS'aJ«Y AN ~ a.11 _ :` ✓ . !J `: .y ` iI t : ,e Ia IY" Q L — .s ? 5, - m.-..—... ...—._.' '' - _ Installation contractor � T45; - - - - " ' - , 1 Morning Star Septic Service ' y'�",'y�knT'u," • AS BUILT 5� �� * Eh:` *,*.� •S ter' 4+ ` r View of existing 1, 000 gallon 4 =' , concrete septic tank with new ` .mot P 4" PVC outlet baffle (map node 1) , 4:} - :` • i _ effluent cartridge filter (yellow component) installed. R 9{ M t i. ., t x {F 4 4 s. -,,i,,,-.,.:........ ice` d a,,s y1 f ,l! ( �1r A,7E i { . - r a erk ,« h ' 0 .i ,a �, ' ' View of installed d-box, 4" PVC S` r '' .t header pipes and trench laterals, t .`, } -i,,- 't, 4 n f looking west. 31i* I-, & i#Y ,.'.- ,,, t ,,x4a..4 5„ ., �;;,, _ \\ „\\\ . ,,,#,-ie,-,...., c...,. ....:, ,.. ..,-. .:, \., -,.. ,,,,...,:.,-.:,4,„,.,-,-;, ,,,....., ,, ......),....,.. .,... ,:,,,,,:,: , . t 4,... :., .\. '.4.,t ,,. .....f.g-'4, . ._ n I , ,n KEVIN L. HASTINGS, PE 3 Jackson Avenue So. Glens Falls, NY 12803 eo, va..:�:-' ` '.' J 523 Ridge Road '}'Vt . 4 (T) Queensbury, NY '1 k' r ?•!rj11-'srY?x 7 Zl �e a r ya} 1ril � ��., �" :„ ., $ u r, f ' WU W. 4" ,•, 0'41 lit. '• '� . View of new 6 outlet polyethylene ,; .tkr distribution box (map node 2) , . '.., ,..., 7 1Y�* r ` with speed levelers installed. iiir ' ` It Liquid level test ' w K :� '� A,:o -.1„�•`1 ` • " -y +�•.,.:•_ �;., PASSED -�srs i&� �A N n Y . ice.t 4.i. - ' L14 • '..? Lid f 1 • }, t ..t' :A. s'we 'r'' a 4.,,t 't Ft• •. )-f' t i �+- e '. f ,. ., I View of absorption trench #1, s ;'' 4 ` with 8 Eljen B43 GSF modules ' + � • ,-).' system sand, 4" PVC lateral• }�� — pipe, soil barrier fabric, and Kv partial backfill, looking south ' + F ' east . '" i t 'Y 4 f* ,r, ' -. _ ' '' ':''''''" ..'' l:tt 1-Y ..r 4 '`ice - c r•16, +N �A], p 01 `,T�t J1�f ,3t �}� �, t a ' ,`�" 1 ,; View of absorption trench #2, �f, -f J ,t> , t� �_, ' , 1 '*4, �= with 8 Eljen B43 GSF modules, ,' ' ,1/; �� - A .,,, , r system sand, 4" PVC lateral ;:mot=r .I J J .a'.", : \ l ;�. '. `• . f ' pipe, 4" PVC 90 degree bend f �;" s,,,-•,, . .., . ! r f (map node 3) , soil barrier 'r , , � + ite "' r ,' . ,' fabric, and partial backfill, t li �, } .. 4 rt'* 1 w i.11w looking south east . x _ tt4•' 'k ` ��tt'v''x v sl ri a ',C' t��g 7 1 kIf q r :, t , t f i `t: �d (� ' "„ i KEVIN L. HASTINGS, PE 3 Jackson Avenue So. Glens Falls, NY 12803 • . • 1,•,a r 523 Ridge Road t (T) Queensbury, NY tom.•'. t ,.s 4 va .& ra` "?s xa + . a' t x4,,.' 4s,, : fib. _.' ' '.., ,.:",,w.,ir:*''f, py �. . View of absorption trench #1, r j '' „ ;�'Z' ' � 'y'`•k `q `' with 8 Eljen B43 GSF modules, 11. i � t` system sand, 4" PVC lateral • ' , 2,p :b pipe, 4" PVC end cap P ; '' ' , , - 1 N. , w 1 , (map node 4) , soil barrier 4 1*.`- 1t; h fabric, prior to trench r # a„''!'` �s.i •: `Y�'" backfill, looking north west . f T § R J ''iett F '#'� 'Ek�a 6 "t-,:tto,;'- Pikl 0 ,"- *A "' :,t , -.;-, -Je'fr':art,i i 0.:' - i��� tom. ,. „f� r 1*4„' x';'N , xti •' j u'd .. V f• �4 r� a { l.-� ,�t1*t' ` "4 ' `, ' '� View of absorption trench #2, *;T "i»°�t. , ' . 1 } ""Ip , , _ with 8 Eljen B43 GSF modules, '`";te ._ V . 41= t , system sand, 4" PVC lateral "'1' i ` {k pipe, 4" PVC end cap, soil -,' r, ., ., n+` 'x <� .. - `: barrier fabric, and fun trench f : .. `' ' ,. -, backfill, looking north west . 1- ),-* =::Attg-' .-44''''',:.:, •,µta :,,11, %ie ', �5 1, •a ) P.. y $• jai 1 µ , ir k.{ !fir ,',A cups-. KEVIN L. HASTINGS, PE 3 Jackson Avenue So. Glens Falls, NY 12803