Loading...
2005-497 TOWN OF QUEENSBURY 742 Ba Road ueensbu NY 12804-5902 518 761-8201 ,�_ Y >Q ry, � ) Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050497 Date Issued: Wednesday, August 13, 2008 This is to certify that work requested to be done as shown by Permit Number P20050497 has been completed. Location: 971 BAY Rd Tax Map Number: 523400-289-008-0001-033-000-0000 Owner: JOSEPH & CATHLEEN FULLER Applicant: JOSEPH & CATHLEEN FULLER This structure may be occupied as a: Garage - 2 Cars Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, f` Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enfor ement Planning Board or Zoning Board of Appeals. " TOWN OF QUEENSBURY cf,ro 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050497 Application Number. A20050497 Tax Map No: 523400-289-008-0001-033-000-0000 Permission is hereby granted to: JOSEPH & CATHLEEN FULLER For property located at: 971 BAY Rd 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other• . .tion hereto filed and approved and in compliance with the NYS Unifonn Building Codes and the Quee •. oning Ordinance. Type of Cons. tion Value Owner Address: JOSEPH &CATHLEEN FULLER AY Rd Gar - 'ars Attached QUE NSBURY,NY 12804 ntial Addition $13,000.00 otal Value $13,000.00 0 Contractor . Builder'. Nam, Electrical ..:.ection Agency Plans &Specifications 2005-497 526 SQ FT RESIDENTIAL ADDITION (LIVING SPACE ABOVE GARAGE)AND 2-CAR ATTACHED GARAGE $137.40 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, September 26,2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Quee)ury;4No day, September 26, 2005 SIGNED BYci) for the Town of Queensbury. ury Director of Building Co nforcement cp-0(4,5; g7 Project Name: BP# Address: 12005 Building Permit Submission SFD NSBURY Checklist 2-Farris ;;; '_,.._.__, '`i CODE All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of Queensbury Building Department. If any of the below items are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Permit Application Completed ............ . yes ❑no ❑n/a 2. Energy Form or CheckMate Energy Code Compliance Forms Complete.. ❑yes ❑no ❑n/a (2 copies) 3. Energy Code Inspector's Report from CheckMate Program_ ❑yes ❑no ❑n/a (2 copies) 4. Septic application completely filled out(if applicable)......... yes ❑no ❑n/a 5. Solid Fuel Burning or Gas Appliance Form... ... ... ... ...... ...... ... ... ... ... .Oyes Ono ❑n/a 6. Electrical Inspection Form... ... ... ... ... ... ... ... ...... ...... ...... ...... ... ..... 54yes Duo ❑n/a 7. Two(2) complete sets of structural drawings .•• •-• ••• • ❑ ❑ .. ... ... . no n/a a) floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule 8. Two(2)site plans showing location of the structure to be built,... ... ... ... `gyes Ono ❑n/a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure... ...... ... ......... ...... ... .. Myes Ono On/a 10. Setbacks to neighboring wells and septic systems,including onsite well... . Dyes lino ❑n/a and septic systems (if applicable) 11. Driveway Permit... ... ...... ... ... ... ... ... ... ......... .................. ... ... ... ❑yam ❑ ° ❑ a n Date: Staff Initial: L:\SueHemingw.0BuildingrernutFORMS\Generic(iiecklist.doc January 28,2003 Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury, (518)761-8256 �14 47 7 A permit must be obtained before beginning construction. Permit File No. 7 No inspection will be made until applicant has received a Fee Paid PrOit-0 �' valid building permit. All applicants' spaces on this Rec.Fee Paid $_ application must be completed and must appear on the Reviewed B application form. Y c Applicant: 1 - e ! ii u e - Owner: g� CSC-�.f'�'1 � L.Address: , J Address: ram`f►'!. '-CL Phone#( i 7415- c ter S c) ' S� Phone#( ) - Si U L 0 1 21105 L�°� : `1 f DoZ� TOWN OF QU ENSEUR'r Property Location: Lot Number: / House Number 97// t34-l"la AO BUILD:',! ,-,ND CODE Subdivision Name: Tax Map Number: ag1 .3- t -33 New Building: residence /commercial Estimated Market Value of Construction: $ /3 ; G CC' QICAddition: residence/ commercial `ddition,what will e f new CI Alteration: residence/ commercial aV r Cj e_. E. - ,addition be? i e--ck m,Se i o FFi a No change to exterior size: residence/coral a Other work(describe ) ' Check OccupancyInformation 1"Floor 2' Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet o Single family dwelling ` word'eL /,--7_S a o Two family dwellin ` " k. •rs o Townhouse •�,� ti` a Multifamily dwelling / c. #of units a a Office a Mercantile a Manufacturing a 1 car detached garage . a 2 car detached garage 6 d'4-° a 3 car detached garage a 1 oar attached garage --r; a 2 car attached garage 5?-6„ff x)y rt. p/ks beIry z,-,,,s 44,-fre 14!lp0 3 car a 0 Storage buildingea$-age ' '� /:/ �'rt/ commercial 0 Storage building- residential • a Other What is the proposed height of the structure cx - �� �qL ("S«" t ram, p p gh feet inches Will any second-hand or ungraded lumber be used? If so,for what? NO Type of Heating System: electri / oil gas/wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed © Number of Woodstoves to be installed 0 List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder -p P_ /A. l I P _9 7_ 0 ,Z� Plumber Q 7�S�S�c$' j Mason Electrician Declaration: please sign below after you have carefully read the statement To the best of my lmowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall•submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construedo t Signs . . _:_f --------- owner,owner's agent,architect,contractor fleaSA Queensbury Building & Code Enforcement - Residential Fin Inspection Office No. (518)761-8256 Arrive: am/pm : t5)i3 ) am/pm Date Inspection request received: Inspector's Initials: /i► NAME: [" AA), PERMIT#: LOCATION: '77 j DATE: (?5:71/71 -2..)? TYPE OF STRUCTURE: Comments: Yes No WA 4" Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at ail exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade t privacy/elm/doors/main entrance 36 inches VIC141X Bathroom/Kitchen watertight Safety glazing/Window in ty g - ; Interior Smoke Detectors -rbon noxide ► - :« - Every level: , ery Bed Outside every .-' . area: , Inter Connected: Battery backup: S r�.e v Attic access 30 inches x 22 inches x 30 inches(height)in accessible area l� Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/tY4 hour fire door/door closer • Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure 7 Final Survey Electrical � !`./ `�� Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Jnspection Forms\Residential Final Inspection Form revised_100405.doc;Revised January 7,2008 Imo.. Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 / /d 5 a v Arrive: am/pm Depart: t,r��!Nam/pm Date Inspection request received: / Inspector's Initials: NAME: r I kr. PERMIT#: d 5� V,7 LOCATION: 01 / /3 i�. y -6 DATE: 7/30t TYPE OF STRUCTURE: Comments: Yes No WA 4' Building Number Address visible from road Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon oxide Detectors < C`?L�l1'l^ �! " Every level: Every Bedr ., Outside every bedroom area: // do�~� \ Inter Connected: Battery backup: II Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 _ dizk(. Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure I/� Final Electrical 1T Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:Building&Codes Forms1Buitdirg&Codes\Inspection Fomhs\Residential Final Inspection Forn_revised_100405.doc;Revised January 7,2008 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL No 'ermit No. 4 .1 t Cert. 2344t. Cut-in Card No. )wner ri,te ,ocation 9.7/ env /2 nstallation Consisting of I �6V! / ,, nstalled By J Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ltroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of ma inspections at any time, and if its Liles are violated,the Company shall have the right to re ke t is certifi e. )ate g-(D -6 7 INSPECTOR Member N.F.P.A.,1.A.E.1. ( 87 ' 3o ) Vedrve / / ,10 -7 Rough Plumbing / Insulationinspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:�am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: r ` NAME: 6'4r PERMIT #: _ S�1fl LOCATION: T? / 1-35tiTcYf rAle- - INSPECT ON: tTYPE OF STRUCTURE: /Rer Add. ��se can Y N N/A ',Lc) C( 3 os� rv� e ► f ky **; Rough Plumbing / Nail Plates 7 4c_S, Plumbing Vent/ Vents in Place ,,,, 1 1/2 inch minimum Drain Size (j;r// r :Y-Le.���� Washing Machine Drain 2 inch minimum 17t2 I C � Cleanout every 100 feet/ change of direction Pressure Test — Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping - --I 50 Q.S.I fo 15 minutes Insulation I esidential Check/ Commercial Check Proper Ve. , Attic Vent /7- . i i 'of Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COM MENTS: R- t_at f/ R, te:t ee_g-_,,, wi,3t.,. — mik-y PC-tzok124.--' i•-kovak- re p. ; Wk L.... zc .; ATM \ftRr -6 1R pou°mac\- - i t.A i _. L3- L ( , s"--' , (.4,tA--.0&- ft5re.... 12,_k. 0,4.4 . L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report' Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: . Lcam/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: elm-, NAME: 6/kr PERMIT #: -21 LOCATION: 9> ? / INSPECT ON: TYPE OF STRUCTURE: Y N N/A_ Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping d 0 P.S. f 15 minutes Insulation / esidential Check/ Commercial Check Proper Ve , Attic Vent of Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape COMMENTS: R. --3cg R__ 41.4 L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 - l CJ ( be rope_ -7 : C)C) / f- oiL,CV 3/ j --rft 7C Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request uest received: 7-- Queensbury Building&Code Enforcement Arrive: am/pm Depa t m/pm './ 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:, ,, ' ) k NAME: r� J PERMIT#: Q5 ? r�- LOCATION: q�/ �( r INSPECT ON: 7— 7 —06- TYPE OF STRUCTURE: Y N N Framing COMMENTS is Access 22"x 30"minimum Co—A! 71/$--6-7S0 Jack Studs/Headers Ced _ ©�,Se r Bracing/Bridging Joist hangers (J:)_ � , �'l Ca j) Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. s A„Le.. -5e5r Stairwells 36 in. or more 1�� Headroom 6 ft. 8 in. Ps- Notches/Holes/Bearing Walls IA- 1 c5 -1 — Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses c_15-41 /11/4"itC4, Anchor Bolts 6 ft. or less on center ' , Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour y^ Fire wall 2, 3,4 hour tiAe"L -• 4 5�•3l��GC Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (II) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: 6-',./) am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: G'w NAME: c 't\( PERMIT#: 01 LOCATION: INSPECT ON: c TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers /cy Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor olts 6 ft. or less on center ce and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade f 71\ ,t Foundation Inspection Report 'f Office No. (518) 761-8256 Date Inspection request received: il Queensbury Building& Code Enforcement Arrive: anvpl �/ , Depart: 7 . 3�am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _ I'V NAME: F GX_ PERMIT#: ®5_ ` / / LOCATION: 474.1 Kr. , _ INSPECT ON: t I /U' S _ TYPE OF STRUCTURE: Comments — — ----- Y N N/A Footings — -- —-- — — Piers i Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. . Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place f Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval / . Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. I L:\SucHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 3 / r Foundation Inspection Reporta't \ Office No. (518) 761-8256 Date Inspection request received: �' Queensbury Building&Code Enforcement Arrive: anvpr4 Depart: 1 ' 7/4/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: — NAME: cc"- 1 _ PERMIT#: a LOCATION: 6 _ INSPECT ON: _ _ i 0 V_ TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. M rials for this purpose on site. te ndation/Wallpour /7/ Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing _ Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval 1 Plumbing Under Slab _ PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Suefcmingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: / Queensbury Building&Code Enforcement Arrive: ami 1� p Depart: —am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: 1'Ut.0 G PERMIT#: _O5_�_�V 7 LOCATION: C�O _ INSPECT ON: 0 / TYPE OF STRUCTURE: jJ). Comments ----------- Y N N/A Footings — — -- — — Piers Monolithic Slab Reinforcement in Place The contractor is responsible"':r providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SucHemingway\Building.Codcs.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Queensbury Building & Code Enforcement - Residential Final Inspection I � Mice No.(518)761-8256 Arrive: am/pd�77D part//:U (f�am/pm Date Inspection request received: Inspector's Initials: 1' 6' P NAME: ` PERMIT#: LOCATION: Z S` E r. .c2_ c r i :3, DATE: __ TYPE OF STRUCTURE:, y - � ` Comments ! Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake (.d 3 inch Plumb Vent through roof minimum 6" 10.. Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more (� �� Guard at deck,porches 36 in.or more / e Exterior Finish Complete / / Interior/Exterior Railings 34 in.to 38 in. pR J l b6_ _� 1 (ZV djJ g nQ We Platform at all exterior doors f C Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 'A" Gypsum Grade away from foundation 6 in.with 10 ft. Q Handrail Termination at Newell Post or Wall t/ ATr'_ (sh-r / I 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating • Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: i Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft,-150 sq. ft. vents Building No./Address visible from road Final Electrical �(rC�ij �C��� /U 5P Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 )f)) Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: amiprik 1 / _Depart: c-am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ' Os- NAME: _ v '� PERMIT#: / 7 LOCATION: _ - INSPECT ON: /O^� - TYPE OF STRUCTU . Comments N N/A ngs - — - -- /oDl//)6 tivi Piers ^- t Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing 4(1 D ltG �i()DO?,e 4i 7z-o( ie..‹ for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place �+� 4) p� ,t n& Foundation Dampproofing t/�Z 1"` I Foundation!Waterproofing /A) To ex i41-it)v Type of Dampproofing/Waterproofing ��UN b4-Tld Footing Drain Daylight or Sump Footing Drain Stone: / ��5 C� ��c_ � 12 inch width FV2y0 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval — I rr Plumbing Under SIab � re Q t i -c/( PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SucHcmingway\Building.Codes.Inspcction.FORMS\Foundation Inspection Report.doc January 28,2003 WINDOW SCHEDULE .. Job Site/Address: cm 4\/ P.cl- 01 u ec ei\I Stxxilj N y LA,c i , Date: Owner: Application- , Application No. 2acs q 97 Window Window Window Unit or Rough Rough SQ.FT. SQ.FT. SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening GlassNis . Egress/Cle Opening Opening or Instructions Letter on Name Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches Size , 411 4 ra5SC4 Vi441. Haft, /I 11' i 40 6..70 S. 9 (9 3 1. 5 ..2 7. QS , us lipAici...... aiNice, 4- Double So si-.5 (30 .cyutzt. We ZoNe - _ 2 , - . C Example Entry A Andersen Narroline 3062 3' 2 6'51/2 15.30 8.36 6.01 34 24 15/35" nin8 Tempg1 Double 1/3" it 11/16 '-* Gla F---z c.... Hung 0 0 a 0— >a 6rrpi 1,--k. Winffalga 0= cm —k rnx -‹ 0 C:\Documents and Settings\Sue\Local Settingaemp\Window Schedule.doc Job Site Address: _ Date:. • Owner: - � (; � ,�°, Application No. File No. ~' ` 17 Building Peril-lit Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req.Light Actual Req.Vent .Actual Sq.Ft. Remarks 1 Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet etarooml 33 ,38 I I ,H 40.0 17 I ' 40 IN,A -Lite hi 9 40 .67'90 1/45. cUp ' L:\SueHemingway\Building.PermitFORMS\NatLight Ventil.Calculation.Sheetdoc s JUL 0 1 2005 TOWN OF OUEE SBURY Q006`11.19 7 BUILDING AND CODE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.6 Release 1 Data filename:Untitled.rck PROJECT TITLE:Joe Fuller CITY: Glens Falls STATE:New York HDD:7635 CONSTRUCTION TYPE: Single Family WINDOW/WALL RATIO:0.10 DATE: 06/23/05 DATE OF PLANS:6/23/05 PROJECT DESCRIPTION: addition COMPLIANCE:Passes Maximum UA= 127 Your Home UA= 120 5.5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter ,R-Valu@ R-Value U-Factor I1A Ceiling 1:Flat Ceiling or Scissor Truss 624 30.0 0.0 22 Wall 1:Wood Frame, 16"o.c. 725 19.0 0.0 39 Window 1: Vinyl Frame:Double Pane 75 0.510 38 Floor 1:All-Wood JoisdTruss:Over Unconditioned Space 624 30.0 0.0 21 Furnace 1:Forced Hot Air,78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.6 Release 1 (formerly MECchec11 and to comply with the mandatory requirements listed in the RESchecklnspection Checklist. /j Builder/Designer Date / / Q REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.6 Release 1 DATE:06/23/05 PROJECT TITLE: Joe Fuller Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane,U-factor:0.510 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,78 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ I Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Si7ef Piping System Types Range(F) ,2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)