Loading...
2000-801 TOWN OF QUEENSBURY FoN 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20000801 Application Number: A20000801 Tax Map No: 523400-054-000-0006-005-000-0000 Permission is hereby granted to: ROBERT & ELLEN BULMAN For property located at: 1113 RIDGE Rd in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ',,\ROBERT & ELLEN BULMAN Septic Alteration Residential 1113 RIDGE Rd QUEENSBURY, NY 12804 Total Value Contractor or Builder's Name / Address Electrical Inspection Agency I.B.S. SEPTIC, IVAN BELL NY Plans &Specifications Septic System Permit for 3 bedroom house 1113 Ridge Road $25.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Sunday, October 20, 2002 (If a longer period is required, an application for an extension must be made to the code Enforcement Officer Dated at the Town eensbu ; Frida , October 20, 2000 ' SIGNED BY 441 for the Town of Queensbury. Director of Building&C de En rcement Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: / E Location of installation: 0 idL C t^v Office Use Q� File Permit No.;.Q �O - v (J/ Tax Map No.5 4/ (Q / S i.L' / Fee Paid �l 72/,3:3z' Owner's Name: n p cc r / d 6 c� (..7(J Address: ._.__, .&4° 111-3 '_ fi I` / 2. INSTALLER'S NAME : .E 18 - _ c -/ f PHONE NO. 2 -v 19 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply# of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older ----)--- x 150 gal/bdrm = (:,5-0 1980- 1991 x 130 gal/bdrm = 1991 -present x 110 gal/bdrm = Garbage Grinder Installed yes / no Spa or Whirlpool Installed yes_ / no Robert Bulman 2000-801 Septic System / Residential 4. PARCEL INFORMATION: (circle applicable information 1113 Ridge Road 40#_raphy re Ground Water Bedr IBS Septic/Ivan Bell sand at what depth a ling - am feet feet well Steep slope clay if well; water supply _%slope other from any septic-system depth: absorption is fl. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. r' I Septic Tank: 41� .9 gallon (min. size 1,000 gal.) Z Z6' l ` Tile Field: each trench ,6 ft. Total System Length: ft. Seepage Pit(s): number of size of each: ft. by ft. r Size of Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the To of Queensbury Sa ' Ty Sewage Disposal Ordinance. la 41\ '..04 ID bi Sig ature of responsible person Date TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518)761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name ,,. i_ Yh Location ;� � ��,(,� .- Date t 'cro j,:ic, Permit # ' SOIL TYPE: Sand-Loam-Clay- Results of Percolation T-st (if applicable) Rate-Mi ute/Inch TYPE OF SYSTEM: ABSORPTION FIELD: Total Lengtl\ Length of each trench Depth of trenches Size of stone - SEEPAGE PITS: Number-r Size - ft. x t. Stone size PIPING: ' size Type Bldg. to Tank Tank to Dist. Box Dist. Box to Field/Pii Openings Sealed? Yws No Partial LOCATION/SEPARATIONS: Foundation to Tank feet Foundation to Absorption feet Separation of Pits _ feet Conforms as per Plot P an Yes No LOCATION OF SYSTEM ON 'ROPERTY: (circle one) Front - Rear - Left Sile - Right Side Middle Front - Middle 'ear COMMENTS: I1I SYSTEM USE APPROVED: YES NO Arrived: Departed:Building Inspector "<it e)4rjb?; '1.6)t1-- 41 TOWN OF QUEENSBURY PR, tyll) BUILDIN6__b_OODE ENFORCEMENT 742 Bay Road r Queensbury NY 12804 114 (518)761-8256 W, SEPT DISPOS`4L SYSTEM INSPECTION r Name impiain. - —,—. °-1/1?- ii 1 i- Loca 1 i,' Date tE) 1 Permit # -RO s 108 SOIL TY E: Sand-Loam Clay- / Results of Pereoi-ation Test- (if applicable) Rate-Minute/Inch TYPE OF SYSTEM: i ABSORPTION FIELD: otal Leith 17' Length of each tr- h 1 _ `_ Depth of trenche• l Size of stone �i L I t.,vfi--�,,;t� SEEPAGE PITS: umb_r- Size - t. • ft. Stone siz= PIPING: Size ype Bldg. to Tan' il, LI " 1;1( Tank to Dist. :ox Dist. Box to ' ield/PI ,A by Openings Sealed? 'Ye`sl No Partial LOCATION/SEP RATIONS: _ Foundation . Tank '3,- feet Foundation o Absorption () feet Separation .f Pits _ ---ffet Conforms a per Plot Plan Yes/ No LOCATION I ; SYSTEM ON PROPERT (circle..o ; 1 Front ( Re:r ' Left Side - Right Side Middle Print - Middle Rear COMMENTS- 1 j , ram.11I L-- ,i,717 SYSTEM USE APPROVED: YES NO;' Arrived: ,-1 Departed: . I 1 l Building Inspector Jo. 94-._ • *JARRETT - MARrIN, LLP Professional Engineering Robert Bulman 2000-801 Septic System / Residential October 6, 2000 - 1113 Ridge Road IBS Septic/Ivan Bell Mr. Robert Bulman Ridge Road Queensbury,NY 12854 Dear Mr. Bulman: On Tuesday September 19, 2000 staff from this office witnessed deep test pits and percolation tests on your Ridge Road property in the town of Queensbury. An area in the backyard approximate 150'± behind the existing garage structure was investigated to determine the presence of suitable soils to locate a new replacement wastewater disposal system. The results and locations of the Test Pits and Percolation Tests in this area are as follows: Test Pit#1 Location: 89'± West of Garage, 31'± South of North Property Line Depth below Grade Soil Description 0 - 11" Dark Brown Silty Loam Topsoil 11" - 32" Yellowish Brown Sandy Silt 32" - 52" Medium to Dark Brown Silt w/ Sand & Clay 52" - 64" Medium to Dark Brown Silt (Saturated) 64" Bottom of Hole Mottling Noted @ 26" (Increases w/Depth) Test Pit #2 Location: 175'± West of Garage, 60'± South of North Property Line Depth below Grade Soil Description 0 - 10" Dark Brown Silty Loam Topsoil 10" - 26" Yellowish Brown Sandy Silt 26" - 50" Medium Brown Silt w/ Some Sand & Heavy Clay 50" - 86" Medium Dark Brown Silt(Saturated) 86" Bottom of Hole Mottling Noted @ 24" (Increases w/Depth) 12 East Washington St. • Glens Falls, NY 12801 518-792-2907 / 518-792-2996 Fax °Printed on Recycled Paper Mr. Robert Bulman Page 2 Re: Ridge Road Property, Town of Queensbury 70" Water Entering Hole Percolation Test#1 Location: 137'± West of Garage, 45'± South of North Property Line Depth: 23" Soil: Yellowish Brown Sandy Silt Stabilized percolation rate of 7 minutes 50 seconds The town of Queensbury Septic code and the New York State Dept. of Health Wastewater Treatment design standards state that a minimum of 2' of vertical separation, in this location, is required between the bottom of a leaching device and seasonal high ground water or bedrock. As indicated by the mottling from Test Pit #2, stated above, seasonal high ground water can be found at 24"+ below existing grade in the area investigated for a new wastewater disposal system. The town of Queensbury definition of a "fill system" is any sewage disposal system that requires fill above existing natural grade. In order to maintain 2' of vertical separation the construction of a "fill system" appears necessary. In addition to maintaining 2' of vertical separation all horizontal separation distances required by both the town of Queensbury and the New York State Dept. of Health (i.e.: 100' setback to a well, 10' setback to property lines, etc.) must be provided. Based on visual observations at the time of the investigation, the locations of your well as well as your neighbors to the north and south are as follows: 1) Bulman Property—Along north side of residence under the driveway. 2) Neighbor to North — In Driveway immediately to the south-southeast of the residence. 3) Neighbor to South — (Bay Ridge Rescue Squad) under landscaping shrubbery north of the Rescue Squad parking area in the northeast corner of their property. No other wells in the immediate area of the proposed replacement wastewater disposal system were observed. Prior to construction of a new wastewater disposal system, locations of all known wells, stated above, as well as all other wells not observed by this office are to be verified and documented as to their exact location to insure that the minimum 100' horizontal separation distance to the new wastewater disposal system is met. For further information regarding vertical and horizontal separation requirements refer to the Town of Queensbury Septic Code Appendix "A" & "B" and the New York State Mr. Robert Bulman Page 3 Re: Ridge Road Property, Town of Queensbury Dept. of Health "Individual Residential Wastewater Treatment Systems Design Handbook". If you have any questions or comments regarding this letter please feel free to contact myself at 792-2907. Sincerely, T rn" d r • Robert U. Holmes II na Project Engineer H. Thomas Jarrett, P.E. Partner F/:2000/0078100100 cc: Ivan Bell, I.B.S. Septic , 1 6-, .,..L., 0 c--- 1 i 1 , 1 / IA, -) \ Cl \ ., 111 ( Z , ! .. I _ i I 1- 5: •:-- ,,,..), f 2%; 1''''.-.. ;' -1 c•-•-:: --'4 , I j...A"ki 1 L, ....o.. 1 , 1 t kt N. t ((,it k-' I UEENSBURY TOWN OF C4, ( A 1 Robert Bulman 2000-801 / 1 Septic System / Residential , C BUILDING &I 00ES *Pt 1113 Ridge Road REVIEWED BY \4......,.,7,t..:,i41'.L........ 1 , -,7 , ,. IBS Septic/Ivan Bell DATE 1 1 -- i) ro (.s. (' 1