Loading...
1999-054 CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Date Jl'1Y 29 19 -99 • This is to certify that work requested to be done as shown by Permit No. 99054 • . has been completed. • This structure may be occupied as a COMMERCIAL NEW BUILD 1195 RIDGE RD. Location Owner COUNTRY KITTY TAX MAP NO. 51 . --1.a•21 . 2 By Order Town Board TOWN OF QUEENSBURY (1Dat," Director of Bldg. & Code Enforcement BLDG. PERMIT NO. 9 9-0 5 4 FILE COPY APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 1195 Ridge Road for the following uses: The Country Kitty B & B • dirm,i4)/P 7/6P/99° - fiO4 DATE SIG,URE OF A'PLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby ('APPROVED ( )DISAPPROVED with the following conditions: Certificate of Occupancy to be issued upon completion of: Install 42" Grab Bar on side of Toilet, Install 36" on rear of toilet, finish handicapped ramp, Final Electrical Inspection, Sheetrock basement, Handicapped Bathroom Sign and parking Sign, no Parking Sign, Tie smoke alarm into HVAC for fan shutdown, final survey TEMPORARY CERTIFICATE OF OCCUPANCY FEE: 04(10.00 POSIT: (4100.00 received on (c-.0 Date of Issua c Director of Bld . & Code Enforcement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES C10 DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. BUILDING PERMIT VALUE $ 120000TOWN OF QUEENSBURY No. 99054 TAX MAP NO. 51 .-1-21 . 2 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to GRANT, CLIFFORD, JR. & OWNER of property located at 1195 RIDGE RD. Street,Road or Ave. in the Town of Queensbury,To Construct or place a COMMERCIAL NEW BUILD at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is JEAN COUNTRY KITTY 1195 RIDGE RD. QUEENSBURY, NY 12804 2. CONTRACTOR or BUILDER'S Name FOX HOLLOW CONSTRUCTION 3. CONTRACTOR or BUILDERS Address 13 FOX HOLLOW LANE QUEENSBURY, NEW YORK 12804 4. ARCHITECT'S Name NEW YORK BOARD 5. ARCHITECTS Address NEW YORK BOARD OF FIRE UNDERWRITERS 6. TYPE of Construction—(Please indicate by X) ( )Wood Frame ( 1 Masonry ( )Steel 1 1 7. PLANS and Specifications 124r• sq ft COMMERCIAL NEW BUILD (THE COUNTRY KITTY) AS PER PLOT PLAN SPECIFICATIONS 8. Proposed Use COMMERCIAL NEW BUILD 180 March 5 2001 $ PERMIT FEE PAID —THIS PERMIT EXPIRES 19 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) 5 March 1999 Dated at the Town of Queensbury his Day of 19 SIGNED BY for the Town of Queensbury Building and Zoning Inspector Building Permit Application Town of Queensbury - Dept. of Community Development, 742 Bay Road, Queensbury, NY 12804 [761-8256] N -D BUILDING & CODE ENFORCEMENT OTICE Requirements prior to issuance -' of this permit: PERMIT FILE NO. CA01 -05� A permit must be obtained before �O beginning construction. No inspections `� will be made until applicant has received n ZoningPERMIT FEE PAID$Board Action I OIL./I, a VALID BUILDING PERMIT. All Area /Use RECREATION FEE PAID$ .-,1 ' applicants' spaces on this application MUST be completed and the signature ED Planning Board Action REVIEWED BE of the applicant must appear on the SPR / Subdivision /Other uilding Inspector implication form. you. J Recreation Fee Payment Applicant: Clifford A. Grant Owner: Same ' Address: 1195 Ridge Rd . Queensbury , NYAddress: ' Phone # (518 ) 798-8291 Phone # ( ) - Property Location: Same Tax Map Number 5� 1 / 21 . 2 Subdivision Name: N/A Section Block Tot NATURE OF PROPOSED WORK: ESTIMATED MARKET VALUE OF THE x New Building: CONSTRUCTION: $ 120 , 000 . xixex9l404143.0( / commercial Addition to Building: residence / commercial OCCUPANCY INFORMATION: Alteration to Building: Primary Building - residence / commercial Single Family Dwelling Residence / Commercial Two Family Dwelt) no change to exterior size Family D QQ.�a Office Other Work (describe below) Mercantile DEB �' 4 1�9g Manufacturing x Other 'C�VJN OF OUEENSBUR�P GROSS AREA OF PROPOSED STRUCTURE: BUfLDING,gND ,nnF If ADDITION, what will use 1st Floor 1248 sq. ft. of new addition be? : 2nd ,Floor N/A sq. ft. Other Floors N/A sq. ft. (not unfinished cellar or basement) ACCESSORY BUILDINGS: Detached Garage 1, 2 car TOTAL FLOOR AREA: 1248 SQ. FT. Attached Garage 1, 2 car Private Storage Building SIZE OF NEW STRUCTURE: Commercial Storage Building Other 32 FEET X 46 FEET Foundation Type: Poured Concrete Will any second-hand or ungraded Number of Stories : 1 lumber be used? If so, for what? (habitable space only) No Height (grade to ridge) : 21 feet TYPE OF HEATING SYSTEM: Number of fireplaces and/or woodstove (circle all which applies) to be installed: 0 *bootx cx0oiix txGracscx/Sc> xx Forced Hot Air Ax cI Other Person responsible for supervision of work as regards to building codes is : Terry Brand 13 Fox Hollow Ln . Queensbury , N. Y . 1P804 Name Addresss Phone Builder: Fox Hollow Cnnat _ 1"R Fnx Hnl l nw In (phiiry 7c1R-R981 Plumber: Same as above Mason: Dale Balwin 621 Buttermilk Falls Rd . Fort Ann 79P- 1371 Electrician: Fox Hollow Const . DECLARATION: Please sign below after you have carefully read the statement. To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a Certificate •`Occupancy'or Certificate of Compliance being issued, an AS BUILT PLOT PLAN by a licensed s , ' or; drawn to ale, showing actual location of project on premises. Signature: 1 1 A_, 4 c (owner, own i is agent, arc it contras r) Application for SEPTIC DISPOSAL PERMIT Town of Queensbury Dept. of Community Development Permit No. Building &Codes Office 742 Bay Road Fee Paid $ Queensbury, NY 12804 1 Location of property for installation: 1195 Ridge R d . Property Owner's Name: Clifford A . Grant Property Owner's Mailing Address: 1195 Ridge Rd . Queensbury , N. Y. 12804 Installer's Name: Bill Threw Inc . Phone # 793-3781 Number of bedrooms (if residential): N/A Total daily flow: 450 (residential - compute Qa 150 gal./bdrm.) Topography: flat, x rolling, steep slope % of slope Soil Nature: sand, x loam, clay, other /depth: Ground water: at what depth? N/A feet / edrock or Impervious Material: at what depth? N/A feet Percolation test: not required, required [rate 2- min. per inch J Domestic water supply: municipal, x well, other If domestic water supply is a WELL, water supply from any septic absorption is 120 feet. _ PROPOSED SYSTEM Septic tank- 1250 gallon (minimum size: 1,000 gal.) Tile field: each trench 50 feet / Total system length: 150 feet Seepage pit(s): number of N/A / size each: . ft. by ft. Size of stone to be used: # 2 / depth or thickness feet HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gallons Alarm system and associated electrical work to be inspected by a certified agency.J For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. /-7/1- / ____, Signature of responsible person: � . =d%: -.7 � Date: 2y7r/99 i - ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 3 9000 HEATING DEGREE DAYS a _ Compliance Methods : PART 5 - Acceptable Practice Method - 1&2 Family Dwellings (only) PART 6* - Thermal Rating - Component Trade Offs 1&2 Family Dwellings; Multi-Family Dwellings (3 stories or less) PART 4* Design by Component Performance ' Commercial Buildings-Hi Rise Residential *Requires submission of worksheets rliFFnrri ;' Trani- 1195 Ridge Rd. Queensbury , N. Y. 12804 APPLICANT' S NAME: PROPERTY LOCATION: Clifford A . Grant 1195 Ridge Rd. Queensbury N. Y . 12804 PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1 . Gross Floor Area - 1248 square feet 2 . Type of Heat - Electric Oil Gas x Other 3 . Is building mechanically cooled? x Yes No 4 . Percentage of area of windows and doors Over 17% x Under 17% 5 . R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R-VALUES AS SHOWN ON PLANS SUBMITTED: a . Roof R 30 b . Exterior walls R 18 . 3 c . Glazed areas R 1 . 7 d . Exterior doors R 10 e . Floors over unheated spaces R N/A f . Edge of slab on grade (heated building) R N/A g. Basement/cellar walls (above grade) R 11 h . Basement/cellar walls (below grade) R 11 i . Heating/cooling-ducts-piping in unheated space R N/A 6 . Service (domestic) hot water heating device Conforms to minimum efficiency per codq x Yes No TEMPERATURE CONTROL MAXIMUM SETTING 1400 - WILL NOT BE EXCEEDED Appli ant ' '' gn Lure Date Phone Number Cam = r=i/27 798-8P91 INSTOR' S REMARKS : GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road ' Queensbury,NY 12804 Arrive am/pm Depart Inspector's Initials NAME: k -k/ 4-5 Co oile PERMIT# f: k ° i LOCATION: DATE : Auk" TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers 1 1 Monolithic Pour Form Reinforcement in Place_ The contractor is responsible for providing protection from frt • fing for 48 hours following the p cement of the ncrete. Materials fo his purpose on s tc FoundationFoundation/W. pour Reinforcement in lace J___ ' Foundation/Damppr ing_ Backfill Approval / Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In _ Insulation Foundation Walls lnt rior R- Foundation Walls E,• crior R- _ Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers _ Bracing/Bridging Joist Hangers__________.__ Jack Posts/Main Beam Air Infiltration Barrier T_ Fire Separation 1, 2, 3, hour tration Scaled Pe Wall 2, 3,4 hour Firestopping COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: `7 2/4 9 Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive3t1p am/ epart 1 ;C 742 Bay Road Inspector's Initials 1-- Queensbury,NY 12804 NAME PERMIT# � LOCATION l( I /. DATE TYPE OF STRUCTURE �f/r ! r-•.` (`ZI 'G7 1Z-----_ N/A YESE NO COMMENTS Chimney/'3"Vent/Direct Vent location Plumbing Vent V/ Roof Complete J Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks Ji Interior/exterior ballasters 4 in.spacing platform/decks ✓/ Stair handrail 34,in.-38 in. ,/i Step rises 7 3/4 in. ✓/✓ Main door 44 in, ✓J/ All others 36 in.'. Lever handles f Exits at grade or platform �1/ Canopy to cover req.,,exit doors +/ Gas valve shut-off exposed&regulator(18 in.)above grade ' Floor bathroom watertight Other floors okay Hot water relief valve \ Boiler/furnace enclosure} <250,000 BTU N/R 250.000 BTU to 1,00flk000 BTU's(1 hour) >1.000,000 BTU's(2 hour) Gas furnace shut off within 30 R.or within line of site /. Oil furnace shut off at entrance to furnace area J// Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/2 doors \if 1 1.2 hour doors and closers / '4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete ‘// Fire dampers,2 hour fire wall/separation or greater 1,. Fire door/shutters 1 '/2 hour,3 hour V, Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware i Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in.Handicapped ramp/handrails continuous/12 in.beyond jj Active listening system and signage assembly space �, Final Electrical Site Plan/Variance required _ Final Survey,new structures lj .As-built septic system layout required Okay to issue temp.C/O(Calif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Calif.of Compliance) GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive' am/pm Depart an/pm Inspector's Initials / NAME: PERMIT# LOCATION: !C�, II DATE : ' l� TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers I l Monolithic Pour Form Reinforcement in Place The contractor is responsible for / providing protection from freezing Ide 6,J, re.role'b for 48 hours following the placement of the concrete. / tI; i►/.� Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vent,in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping NEW YORK FIRE & SIGNAL CORP. 4 Glens Falls Technical Park Glens Falls N.Y. 12801 (518) 798-9551 - (518) 792-5199 fax July 22, 1999 Kip & Jean Grant Country Kitty B & B 1195 Ridge Road Queensbury, N.Y. 12804 Re. Alarm Certification To whom it may concern: Please accept this letter as confirmation that as of July 22, 1999, a fire alarm system has been installed at the Country Kitty B & B located at 1195 Ridge Rd Queensbury N.Y. The system consists of a commercial U.L. rated Ademco vista 128 fire alarm control panel / communicator with smoke / heat detectors , heat detectors , strobe / horns and an exterior siren. Upon alarm, the interior strobe / horns will flash and sound, the exterior siren will sound, and a digital signal will be transmitted to a 24 hour U.L. rated central station known as Emergency 24 (registration number S2585N). The signals will then be processed, and acted upon by operators, who will notify the proper authorities as well as persons designated to us by the subscriber. If you have any questions, or require any further information , please give me a call at your earliest convenience. Sincerely urs, Ernie Sacco General Manager Page 1 COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arriv part 742 Bay Road Inspector's Queensbury,NY 12804 1 NAME COO T�`� I`1\ \ 1 4 PERMIT LOCATION E \ gj R t DC'�E V\ DATE TYPE OF STRUCTURE N/A YES NO COMMENTS Chimneyr'B"Vent/Direct Vent location Plumbing Vent V/ Roof Complete Y Exterior finish moire V / Interior/exterior guardrails 42 in.platform/dedcs V -1 Thu-- G ARQ2:F1 1 L '- 61 C) R RCA Interior/exterior ballasters 4 in.spacing platform/decks � / Stair handrail 34 in.-38 in. Y , F00OV P11-`o13 'NJ )UT°� Step risers 7 3ii m. Main door 44 in. 's/ � � _ B�Eu- F)F M 116b01 T\C'*( %6 Au ethers 36 in.Dever handles V � � l� ` �1 t � � A Exits at grade or platform \, 1 r+�© 1►� tl L R"\9 t W3bLAJPITk \ Canopy to cover req.exit doors ", ° 1 Gas valve shut-off exposed&regulator(18 . e grade 1 �' Floor bathroom watertight Other floors okay f' — r=t t3Ptt--. ELEC-MGPL_ Hot water relief valve V/ {� Boiler/furnace enclosure_ V — CCANL-EVE AU- t'L-CIA j\'�t�7 <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(I our) — \t bT A Lt Tc,A P t ci p Olv NN6p\C j >1,000,000 BTU's(2 hour) J 1�`) Gas furnace shut off within 30 ft.or within ine of site ✓/ 1"1 Oil furnace shut off at entrance to furnace ea ✓ \ 1 F}� \\R►vO1� n j(�`1-. Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 'h doors / Al 1 1/2 hour doors and closers -- 1)\F1L� \�\ \�- U 3 4 hour corridor doors and closers ,/ Firewalls/fire separation,2 hour,3 hour complete 1,•.-` VeW-A IJ ) ,j\CI \ ixec ES Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 'h hour,3 hour ✓/ Nt bL, Ceiling fire stopping vents or fa sq.I' V , ,�1� HAe3t �Fan shutdown,smoke vents or fan ..� Q 1-t t Exit door/panic bars assembly hardware Elevators / 11 Cr C.OUZWg_ Elevator signage ✓ Off- Handicapped bathroom grab bars/sinkshoilets / \JP1L , Handicapped bath/parking kit signage V Handicapped servicem counters 34 in., 12 6 in. / �� - cjj'Handicapped ramp/handrails continuous/12 in.beyond I .�/ ..__ �'�� Active listening system and signage assembly space Final Electrical \I Site PlanNariance required _ J / I`�7 Final Survey,new structures i {�'` As-built septic system layout required -c-'TE� VCR-- ` — Okay to issue temp.C/O(Calif.of Occupancy) \ F- Okav to issue C/C permanent(Calif. /Of (Certif.of Occupancy) Pr, ) L5�y VI Okay to issue C/C(Cif.of Compliance) �j COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive k° am/ Yt Depart 742 Bay Road Inspector's Initials Queensbury,NY 12804 NAME C0i).0—rjRq 1 1 `t PERMIT y LOCATION 11Q5 VI 1 S E_ R DAD DATE — — TYPE OF STRUCTURE ,130 t 1 C) N/A YES NO COMMENTS Chimneyr'B"Vent/Direct Vent location PC IEUM 1 �� FI Plumbing Vent Roof Complete Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks Interior/exterior ballasters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7 3ia in. J Main door 44 in. / All others 36 in. Lever handles V/ Exits at grade or platform Canopy to oov req.exit d s s V Gas valve shut 4 ff exposed&regulate (18 in.)above grade Floor bathroom 'ght Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,100,000 BTU's(1 hour) >1,000,000 BTU's( hour) Gas furnace shut off w' in 30 ft.or within line of site Oil furnace shut off at- . ce to furnace area Stockroom enclosure(1 hour),3/4 hour door Storagelreceiving/shipp g room(2 hour), 1 '/z doors I 'z hour doors and cl 3 4 hour corridor doors d closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Alive listening system and signage assembly space ` Final Electrical J -Site Plan/Variance required Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Ceatif.of Occupancy) �( Okay to issue permanent CIO(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)'761-8256 Dept. of Community Development Town of Queensbury Arrive//' am/pm Depart am/pm 742 Bay Road Inspector's Initials Queensbury, NY 12804 ' NAME t Yr°,, PERMIT# 1*--05 LOCATION j4E_Rc:7 DATE 3 C TYPE OF STRUCTURE N/A YES NO COMMENTS Chinmey/"B"Vent/Direct Vent location Plumbing Vent Roof Complete '7,//j / Exterior finish grade complete A c// 4.04 "'`' G"// hiaior/exterior guardrails 42 in.platform/decks Interior/exterior ballaslers 4 in.spacing platform/decks (5 /it s t, . e x�e CV/ Stair handrail 34 in. -38 in. Step risers 7 3/4 in._ Main door 44 in. �11 others 36 in. Lever handles Exits at grade or platform ok ,l G /4° -e- Canopy to cover req.exit doors — ���`� Gas valve shut-off exposed&regu . or(1: m.) ...ve grade Floor bathroom watertight f/` a h C J.z i) Cent Other floors okay 9 Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 B 's(I hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft. . within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/z doors 1 'i hour doors and closers 3 4 hour corridor doors and closers Firewalls/fue separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures .As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent CIO(Calif.of Occupancy) Okay to issue C/C(Certif.of Compliance) GENERAL INSPECTION REPORT I). Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depa •a • ,; Inspector's Initials 4 NAME: 12 9,N T PERMIT# -©5- LOCATION: K I o20,6- k,') . DATE : 5 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is - ••nsibl: for providing p otection •m :- ing for 48 hours ollowin_ the play -ment of the concre . Materials for thi urpo.- on site Foundation/Wall ur Reinforcement in ace Foundation/Damppr • s g Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in lace RoughPlumbing �= I �'A3D eating Rou ation griki * I Foundation Walls Interio R- Foundation Walls Exterior R- Floors R- / Walls R- q `/ Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam , Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping i/41. 6-- GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road 2 Queensbury,NY 12804 Arrive am/pm Depart I '`' am/pm Inspector's Initials NAME: (Poe*)% PERMIT# LOCATION: /Oe_ DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is re .•nsible for providing protection om freez'• for 48 ours folio : the place ent of the co te. Materials for ' ••se on • Foundation/Wallpour Reinforcement in P1• - Foundation/Damppr' •fing Backfill Approval Plumbing Under S b Plumbing Vent/V- is in Place Rough Plumbing 1 Heating Rough-Ini Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- :per Vent, Attic Vent naming Jack Studs/Headers V/ Bracing/Bridging V Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping L a---c- (-' 6KA . GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depart .0 am/pry Inspector's Initials ' " PERMIT# 03 NAME: �- �--'F���4 �i II]`1 LOCATION: K,0476' DATE : 2► TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form '\ Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place R ugh Plumbing eating Rou -In i` Insulation ARTi/ &)5r ' © / . Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- \ Walls R- 1 / \'\ Ceiling R- `t ✓ Duct work or piping in unheated spaces R- �' \ Proper Vent, Attic Vent i Framing t! Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping TORN OF QUEENSBURY BUILDING b CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name Location Date Pe i # ___ SOIL TY E and-Loa Clay- Results of P lation Test- (if applicab e) Rate-Minute/Inch TYPE OF SYS EM: 1 ABSORPTION IELD: Total Leng V r`J� 0Length e h trench Depth of tre ches 3 ' Size of stun * -- SEEPAGE PITS: Number Size - ft. x ; ft. Stone size PIPING: Si��e Type Bldg. to Tank T Tank to Dist. Box h --�'—cj Dist. Box to Field/Pit t4 4 Openings Sealed? �� No Partial LOCATION/SEPARATI0 : Foundation to Tank 1-V feet Foundation to Absorption z5 feet Separation of Pits+ _ eet Conforms as per Plot Plan es No LOCATION OF SYSTEM ON PROPER (circle Front - Rear Left Side - Right Side Middle - Middle Rear COMMENTS: /}`r/Uk1 '_ 0 K SYSTEM USE APPROVED: YES NO Arrived: _�7 Departed: 4){./// Building Inspector 9 ;ooPi TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 R,c),/ TQJD (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name Location X� _ c, Dates/.1_C'1ei Permit # —� SOIL TYPE: Sand-Loam-Clay- Results of Percolation Test- (if applicable) Rate-Minute/Inch TYPE OF SYSTEM: ABSORPTION FIELD: Total Length Length of each tr h Depth of trenches Size of stone SEEPAGE PITS: Nu ber Size - ft.,, x ft. Stone size PIPING: ' ' Size Type Bldg. to Tank r Tank to Dist Box Dist. Box to ' t Openings Sealed? Yes No Partial LOCATION/SEPARATIONS: Foundation to Tank feet Foundation to Absorption feet Separation of Pills of Plan Yes No LOCATION OF SYSTEM ON PROPERTY: (circle one) Front - Rear -/Left Side - Right Side Middle Front Middle Rear COMMENTS: 6Q \ '`:5 Sr Zpo 2 *t . /fU6 SYSTEM USE APPROVED: YES 0 Arrived: Departed: Building Inspector GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road - •ems % ` Queensbury,NY 12804 Arrive am/pm Depart //• m Inspector's Initials NAME: aQ,44.1.c PERMIT# - 05 LOCATION: 1 2 e 49, DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers, I I Monolithic Po , Form \ Reinforcement i. Place 1 The contracto 's re •,,nsible for providing pro =• 'on '1 •m freezing for 48 hours folio 1 the placeme t of the concrete. Materials for this p •.se on site Foundation/Wallpour Reinforcement in Pl. Foundation/Dampproo s .g Backfill Approval Plumbing Under Slab Plumbing Vent/Vents i Place Rough Plumbing Keating Rough-I?) _ /� . ,'insulation /) c�t64'/ (,o M.Pa—TE tea (usuL . 1 R- Ict Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- A L� �46o VG 6 8,4-�c— q--L 5 t e.'S i Walls R- l�J / 6 . ,q 19 Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depart - am// m Inspector's Initials NAME: CQ( A tJ PERMIT# LOCATION: DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsibl, for providing protection from ; =- ing for 48 hours fol wing the .lacemmnt of the concrete. Materials for this p se o site Foundation/Wallpo Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab , Plumbing Vent/Vents in Pace Lei Plumbing eating Rough-In C-< _ � I/05 UL • /4.5 ation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive •>' am/pm Depart am/pm Inspector's Initials 'DX NAME: (jJ, AA, PERMIT# � .s LOCATION: /�.{ DATE : TYPE OF STRUCTURE: f RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form A Reinforcement in Place `" j� Eve � 4i The contractor is response le fo providing protection from s .u g for 48 hours following the pl..: ,entY of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road II Queensbury,NY 12804 Arrive /C 1J am/pm Depart am/pm Inspector's Initials NAME: C// 401 61-fr,k PERMIT# LOCATION: Gf i DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Place Ax F 1 UfiQ* 4 ( /N ty2 /G The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Back fill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping jot; L GENERAL INSPECTION REPORT Town of Queensbury • Dept.of Community Development Date inspection request received: 3 f /( Building& Code Enforcement I 742 Bay Road 3 Queensbury,NY 12804 Arrive am/pm Depart Inspector's Initials NAME: 6Gcn`--/ C:).4 if/e',./— PERMIT# `d s1 LOCATION: --" DATE : ,3`3 a `�i' 9JY TYPE OF STRUCI a / RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the place • -nt of the concrete. Materials for this se on site Foundation/Wallpo Reinforcement in Place ($ undation/Dampproofing v Backfill Approval Plumbing Under Slab Plumbing Vent/Vents i• Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2. 3, 4 hour Firestopping GENERAL INSPECTION REPORT 3 -:._ (:) Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depart pm Inspector's Initials., 6 i NAME: CND`\ ERMIT# J TYPE OFLOCATIOSTRUCTURE: A, Q u � , I� ATE : — / RECHECK /1N/A YE NO COMMENTS tings/Piers V t Monolithic Pour Form Reinforcement in Place _4� /' The contractor is responsible for g)5/ emir (i_f, / providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing I Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping I _ 143, . x g 0 , . . , J-10 ;V - �ry w-) 1 ---71 1 ci -)C U = x .ram ;r1 Yw....NW4 : _ _ — . 66 ‘-) Ilv -.' . ------' r"-C p. 71 I cm a 7a.ew j NO3'07'00" \boo - 250.00 0 - - - _ -I • 23.76' ' A1=1(1E3';NIGM 20 Ni.1O-1. !C O h �21 tia. Z sF Oo ✓ IN) 1s' Nll 0 N O03 ..) O• lb N O , ' ON ^51 - . A r. l W 7) Z f*t I ,,, N -I O N u 0 A . 250.00 S03'07'00"W D (NEW YORK STATE �.0 UTE gL) W Co • ct U Ck 0 ir W � W 0 _> Z U W o W C7 Si- LLZ V Lu Oo E W r*'" 3 0 om OTHER LANDS OF KENNETH H. SHELDON z b w ♦� tp r z U 1 x1 ' S8T24'00"E O � 797.00 LR.F S87'24'00"E Ca �mq p; o 30 F 250.00 m w `� I w 0 3 H I t'�� s a Or O 0 0o AR 1p N LANDS OF SHELDON j� eUflpti o _ CONVEYED TO G�GINT Z 4.57 acres LANDS OF o r4 GRANT o !�►D e 1.43 acres f o O O N MO W N 1- IO of 0 �� . " Z Parr z- g Hull I wII� a�g�� R / d11111wit11a[l�Re I �� I.P.F. ji 797.00 i� E" F BLAZED LINE FOUND x y, x 1 U) � � � R N87'4 00"W x " x x = 25 .00 I. I.R.F. R.F.!_ N87'24'00"W . W LANDS N\F OF 4 Co EMIL & BERTHA YAGER A CQ CD CD In v V1 z '.�. � A -� ;> W r %7 C0 ra 0 Ulm Dates 21.1D�6 scab T-W u S- 1 SHEET 1 aF 1 DWG. NO. 87207