Loading...
98-661 CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK May 4 99 Date 19 _ • This is to certify that work requested to be done as shown by Permit No. 98661 1 . has been completed. 2 ,796 SQ. FT. COMMERCIAL ALTERATION • This structure may be occupied as a 1382 RIDGE RD. Location OwnerAMERICADE/ DUTCHER, WILLIAM TAX MAP NO. 52 . -1-1 By Order Town Board TOWN OF QUEENSBURY r / at" ___.,...„ ,__) Director of Bldg. & Code Enforcement BUILDING PERMIT VALUE $ 20000 TOWN OF QUEENSBURY No. 98661 TAX MAP NO. 52 . -1-1 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to AMERICADE, DUTCHER, WILLIAM OWNER of property located at 1382 RIDGE RD. Street,Road or Ave. in the Town of Oueensbury,To Construct or place a 2,796 SQ_ FT_ COMMF..RCTAT. AT.TF,RATTON at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNERS Address is 1875 PILOT KNOB ROAD KATTSKILL BAY, NY 12844 2. CONTRACTOR or BUILDERS Name DUTCHER, BILL 3. CONTRACTOR or BUILDERS Address 1875 PILOT KNOB ROAD KATTSKILL BAY, NY 12844 4. ARCHITECTS Name 5. ARCHITECTS Address 6. TYPE of Construction—(Please indicate by X) COMMERCIAL ALTERATIONS ( 1 Wood Frame ( )Masonry ( 1 Steel ( 1 7. PLANS and Specifications 2,7448• SQ. FT. COMMERCIAL ALTERATION AS PER PLOT PLAN AND SPECIFICATIONS 8. Proposed Use 2,796 SQ. FT. COMMERCIAL ALTERATION $ 140 2000 PERMIT FEE PAID —THIS PERMIT EXPIRES November 13 19 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Oueensbury before the expiration date.) 13 November 1998 Dated at the Town of Queens y this Day of 19 SIGNED BY for the Town of Queensbury Building and Zoning Inspector Building Permit Application Town of Queensbury - Dept. of Community Development, 742 Bay Road, Queensbury, NY 12804 1761-82561 BUILDING & CODE ENFORCEMENT NOTICE Requirements prior to issuance M A permit must be obtained before of this permit: PERMIT FILE NO. qp• 6‘,1 beginning construction. No inspections PERMIT FEE PAID$ ifei will be made until applicant has received n Zoning Board Action L(J a VALID BUILDING PERMIT. All Area /Use RECREATION FEE PAID$ applicants' spaces on this application MUST be completed aad the signature IT Planning Board Action REVIEWED BY: iiii of the applicant must appear on the SPR / Subdivision /Other Building Inspector pplication form. n, , ReJftrTWX( eation Fee Pay' ent t,�' Applicant: Y�/i 1 kiurcl 't-oty.sc A i �,er: V v t i G-hr1�k-kC lr l.,e Ir • Address: 1 g 1 5 g c 10 knO1, RC-S, Address: 'f CA ( \ BaN a4 IZJ Phone # ( 5 l8- )664 - c(6 to'--) Phone # ( ) - Property Location: 13 4o1 `-i;a.se.. Tax Map Number 52, i / 1 Subdivision Name: -- Section Block I.nt NATURE OF PROPOSED WORK: ESTIMATED MARKET yALUE OF THE New Building: CONSTRUCTION: $ 'j,4 o .•o residence / commercial Addition to Building: X residence / commercial OCCUPANCY INFORMATION: Alteration to Buil. • 8 . • Primary Building - / commercia Single Family Dwelling Residence / Commercia Two Family Dwelling no change to exterior size Family Dwelling Office Other Work (describe below) Mercantile Manufacturing . Other GROSS AREA OF PROPOSED STRUCTURE: 1st Floor 11,7iIf ADDITION, what will use sq. ft, of new addition be? : 2nd .Floor ° sq. ft. Other Floors sq. ft. (not unfinished cellar or basement) ACCESSORY BUILDINGS: q �x(5T Detached Garage 1 2 car TOTAL FLOOR AREA: 11 14 SQ. FT. Attached Garage I, 2 car Private Storage Building SIZE OF NEW STRUCTURE: Commercial Storage Building Other FEET X "'""Rs FEET Foundation Type: giiht Will any second-hand or ungraded Number of Stories : lumber used? If so, for what? (habitable space only) 4e Height (grade to ridge) : 151. feet TYPE OF HEATING SYSTEM: Number of fireplaces and/or woodstove (circle all ich applies) to be installed: Q Electric / 411.1, / = -. Forced Hot .ir / :aseboard / Other Person reqponsible for s�z e ,visio o work as regards to buildiag codes is : 011A. C71�'rcki 1 ta" fro-orI . cosce• cf3tO7 Name Addresss Phone Builder: Plumber: . Mason: Electrician: k..1,J4P,6 13 Haa7.1 Uzi* iday 3- 524 DECLARATION: Please sign below after you have carefully read the statement. To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, an AS BUILT PLOT PLAN by a licensed surveyor; drawn to scal-, sho.. ng actual location of project on premises. Signature: __.- �----/f ,Alii► _...rA4.b, (owner, owner's is gent , contractor) //Fr 4%2 // z lK -_ ENERGY CODE COMPLIANCE APPLICATION Tlawma TAW TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Compliance Methods : PART 5 - Acceptable Practice Method - 1&2 Family Dwellings (only) • PART 6* - Thermal Rating - Component Trade Offs 1&2 Family Dwellings; Multi-Family Dwellings (3 stories or less) PART 4* Design by Component Performance Commercial Buildings-Hi Rise Residential *Requires submission of worksheets AAPPPPLICANT' S NAME:( PROPERTY LOCATION: t,/ J h)sok) LI tq tk CiIV i� c PART 5 METHOD OF COMPLIANCE_ BY ACCEPTABLE PRACTICE: 1 . Gross Floor Area - '� J '/ Cf square feet 2 . Type of Heat - Electric Oil Gas Other 3 . Is building mechanically cooled? Yes X No 4 . Percentage of area of windows and doors Over 17% )( Under 17% 5 . R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R-VALUES AS SHOWN ON PLANS SUBMITTED: a . Roof R b . Exterior walls R c . Glazed areas R d. Exterior doors R e . Floors over unheated spaces R oa1t f . Edge of slab on grade (heated building) R 'cfi g. Basement/cellar walls (above grade) R 0 h. Basement/cellar walls (below grade) R i . Heating/cooling-ducts-piping in unheated space R olJ 6 . Service (domestic) hot water heating device Conforms to minimum efficiency per code )( Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140° - WILL NOT BE EXCEEDED Appl • a ' s • ure Date Phone Number •/Z. s83 •cx� INSPECTOR' S REMARKS: COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive!'JC am/pm Depart am/pm 742 Bay Road Inspector's Initials Cp/i— Queensbury, NY 12804 NAME Nc\-Ne.,Ne PERMIT#C LOCATION TYPE OF STRUCTURE . .Y1 N/A YES NO COMMENTS Chinmeyr'B"VenUDired Vent location Plumbing Vent Roof Complete Exterior finish grade complete interior/exterior guardrails 42 in.platform/decks Interior/exterior ballasters 4 in.spacing platform/dedcs Stair handrail 34 in.-38 in. Step rises 7 3/a in. Main door 44 in. Allin.Le , Levyer handles andll es Fv is at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regu ator(18 in.)above grade Floor bathroom watertight Other floors o ay Hot water relief . ve Boiler/furnace eiclos - <250.000 BTU N/R 250.000 BTU to 1,000,000 : 's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 IL • within line of site Oil furnace shut off at entrance to mace area Stockroom enclosure(1 hour),3/4h.ur door Storage/receiving/shipping room( hour), 1 '/2 doors 1 '2 hour doors and closers 34 hour corridor doors and closers ✓ Firewalls/fire separation,2 hour,3 our complete Fire dampers,2 hour fire wall/sep. .1 ion or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq ft.__ Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators \ Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required_ Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) I/ Okay to issue C/C(Certif.of Compliance) . t L-'V YL-t1�' COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive 9'`71 am/pm Depart am/pm 742 Bay Road Inspector's Initials Queensbu ,NY 12804 NAME PERMIT# S 4.-C6 LOCATION DATE TYPE OF STR CTURE N/A YES NO COMMENTS Chimney/"B"Vent/Direct Vent location Plumbing Vent Roof Complete Exterior finish grade complete ��� h7�r. , interior/exterior guardrails 42 in.platform/decks haerior/exterior ballasters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. �] vi R j H�i,.0 o_` trmyn ;it Step risers 7 3/4 in. 1/ J 'f Main door 44.in. Cc,i cre t� All others 36 id\ Lever handles F> s at grade or pla't(orm Canopy to cover req.eldt d.• Gas valve shut-off exp. ,• : regulator(18 in. above grade Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250.000 BTU N/R 250.000 BTU to 1,000,00' BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 or within line of site Oil furnace shut off at entrance •furnace area Stockroom enclosure(1 hour),3 hour door Storageheceiving/shipping r•• (2 hour), 1 '/2 doors 1 ''z hour doors and closes 3 4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space • Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required_ Okay to issue temp.C/O(Certif of Occupancy) Okay to issue permanent C/O(Cetif.of Occupancy) Okay to issue C/C(Certif of Compliance) COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)'161-8256 Dept. of Community Development Town of Queensbury Arrive/>am/pm Depart am/pm 742 Bay Road Inspector's Initials '/)I- Queensbury, NY 12804 '1 NAME hty ` L. PERMIT# LOCATION P ti t DATE Zi:- TYPE OF STRUCTURE ` N/A YES NO COMMENTS Chimneyf'B"Vent/Direct Vein locationVent A// ,(1 Roofbing Complete . 4 �`7 /V 0 YC' £5 ' Exterior finish grade complete J 1 - Interior/exterior guardrails 42 in.platform/decks =; c 0 l r /e 5/4- hi.erior/exterior ballasters 4 in.spacing platform/decks Stair handrail 34 in. -38 in. Step risers 7 3/4 in._ Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18 in.)above grade Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/2 doors 1 1/2 hour doors and closers_ J ,`pj '.hour corridor doors and closers 1 ik Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft.Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures .-as-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) ✓ Okay to issue C/C(Certif.of Compliance) 4 COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive / am/pm Depart am/pm 742 Bay Road Inspector's Initials 'N.— Queensb ,NY 128Q4 �� ,- NAME PERMIT (0 LOCATION DATE TYPE OF STR CT �� �� N/A YES NO COMMENTS Chiamey/"B"Vent/Direct Vent location "� Plumbing Vest ,X // I h / 2 4 r -L '� Roof Complete _ Exterior finish grade complete interior/exterior guardrails 42 in.pl arm/deck� e.. / r/der in erior/exterior allasters 4 in.spa gplatfofmdc/des Stair handrail 34 .-38 in. Step risers 7'/sin. f Main door 44 in. l 2 k All others 36 in. �srL *. � '�i j ��� c Lever handles Exits at grade or platform SK,i 1 Canopy to cover req.exit doors Gas valve shut-off exposed&r,Egulator(18 in.)above grade / / (2 7r Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft_or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),'/s hour door Storage/receiving/shipping room(2 hour), 1 %doors 1 'i hour doors and closers 3 4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire walllseparation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking Id signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Alive listening system and signage assembly space Final Electrical Site PlanNariance required _ Final Survey,new structures As-built septic system layout required Okay to issue temp.CIO(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.�' Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL `(/, 'anel Board No Cert.No 6 6 2 7 2 Cut-in Card No. 6/ )wner fL L 1 U re, ,ocation /e! ,p G AO. 0..LL nstallation Consisting of..©I'"e e a N L P - Q. - S14'I Tr ig6 7 /26'c-eno if L� ,�. -S p_ L f-<eg /rc 0 c=�c r r 4-1 7-. '-5f ,,/,c/#.t i nstalled By -/r' .6/L- Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the itroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making i tions at any time, and if its ules are violated,the Company shall have the right to re o this c te. 9 )ate d 3.�` [ INSPECTOR Member N.F.P.A.,I.A E.I. COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)'761-8256 Dept. of Community Development Town of Queensbury Arrive /j?o am/pm Depart am/pm 742 Bay Road Inspector's Initials Queensbury, NY 12804 NAME 109t4W PERMIT# 4 LOCATION / 7- L/d" DATE a2j f TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney/'3"Vent/Direct Vent location Plumbing Vent -- 4/71,;Jr _-1--r"-r go)rs - lre Cir"'C),r Roof Complete V :,/ Exterior finish grade complete Vj Interior/exterior guardrails 42 in.platform/decks V cj Ai/y rot Interior/exterior ballasters 4 in.spacing platform/decks i// �° J /f ¢ 1� Stair handrail 34 in. -38 in. !� / - 24s c,// ii / Ft yet Step risers 7 3/4 in. ✓ /� %. �� Main door 44 in. +�/ C t- ...yd.,;, , 4�''"' -"" -ei All others 36 in. ,,// r Lever handles i7^ / -'je / rr' 1�f �.tsr Exits at grade or plat form i// -Can to cower r exit d e. ✓ ,4 v /i Gras valve shut-off exposed& -: lator(18 above Floor bathroom watertight t,, Other floor,okay i A s t,rc.A./ ` Hat water relief valve ✓ .— ,. // Se Vein S7' -4,- %/ e Boiler/furnaceearclosure j <250,000 BTU N/R t� 250,000 BTU to 1,000,000 BTU' (1 hour) — l 44, 7l�' -St `,,,. , , >1,000,000 BTU's(2 hour) Vf _ / // + -, . J'Axle-AV,* Gas furnace shut off within 30 ft_or ithin line of site S.:l�� i% Oil furnace shut off at entrance to ' ace area Stockroom enclosure(I hour),3/4 .ur door t7 4),.. L' ' - Storagureceiving/shippingroom ► hour), 1 '/z doors , i/� / _ f /� % /9 � ,, 4i,. 1 z hour doors and closers ✓ f� b f 3 4 hour corridor doors and cl•. Ftrewalls/fire separation,2 hour,3 hour complete ✓ 7 / /V v/ 1247 ) "' /' Fire dampers,2 hour fire wall/se paration or greater V .' / � Fire door/shutters 1 '/2 hour,3 hour V 167 4v U Ceiling fire stopping 3,000/5,000 sq.ft. / / V /1 Fan shutdown,smoke vents or fan — C,�"�► ,_ Y/si.4 fr.,,, (�:"./.';'e"'e,- Exit door/panic bars assembly hardware _ ✓ Elevators Elevator signage V / Handicapped bathroom grab bars/sinks/toilets r „. Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space ,/ Final Electrical Site Plan/Variance required Final Survey,new structures r� .-Ns-built septic system layout required V Okay to issue temp.C/O(Cetif of Occupancy) / Okay to issue permanent C/O(Certif.of Occupancy) V Okay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive am/pm Depart am/pm 742 Bay Road Inspector's Initials c!) Queensbury,NY 12804 NAMENocv:?:),(-- J PERMIT#, ,S (2. LOCATION 3 Z DATE —a.3-C C1 TYPE OF STRUCTURE ( \ ,� N/A YES NO COMMENTS Chimneyr'B"Vent/Direct Vat location , Plumbing Vat � b Roof Complete i' Vidtsii hier e- 47, fish Exterior finish grade oompl= hrterior/exterior guardrails 4 in.platform/ / d c hrteior/exterior ballasters 4 .spacing platf decks %flu&. (i-0"/"cc f4, L- Stair handrail 34 in.-38 in. C' ter- /Jh� c.` tl Step risers 7 3/4 cot. N e� :��� >°/nf Main door 44 in. -- - Cj�� All others 36 in. Lever handles Exits at grade or platf. Canopy to cover req.e doors Gas valve shut-off exp &regulator(18 in.)above grade Floor bathroomw:, : git Other floors okay Hat water relief valv Boiler/fu mace encl.: e <250,000 BTU P 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 'h doors I Li hour doors and closers 3 4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 'h hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan_ Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required _ Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive JO?c am/pm Depart am/pm 742 Bay Road Inspector's Initials ;— Queensbury,NY 12804 1 NAMES Q�`s .• PERMIT# — I LOCATION (e, DATE .P Afir TYPE OF STRUCTURE N/A YES NO COMMENTS ChimneyP'B"Vent/Direct Vent location Plumbing Vent !) Az., / u�d� ‘rrerc�k Roof Complete Cs Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks CC rE�i G/X e c.. ✓•�� A Interior/exterior ballasters 4 in.spacing platform/decks / Stair handrail 34 in.-38 in. Co�/ Step risers 7 3/4 in. '"� Cd� Main door 44 in. All others 36 in. / �✓e( ✓ Lever handles 0 Exits at grade or platform Canopy to cover req.exit d Gas valve shut-off exp regulator(18 in.)above grade Floor bathroom w Other floors okay Hat water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/z doors I !'z hour doors and closers '.hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,chedcout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance)_ e- G Q z,5� � `i GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: /°11)11/1 Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive lee►L am Depart m Inspector's In' ' NAME: ,�� PERMIT# LOCATION: 1 J>S� is 1 DATE : _ _ TYPE OF STRUCTURE: t RECHECK N/A YES NO COMMENTS Footings/Piers 1 1 Monolithic Pour Form Reinforcement in Place The contractor is responsi'le for providing protection from ing for 48 hours following the pla., i e of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing A-fcv,eiv ccd..at V Heating Rough-In elation y� Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- \ Ceiling R- :1F6 Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT 1 Town of Queensbury \\ , Dept. of Community Development Date inspection request received: /� �� Building& Code Enforcement tos 742 Bay Road Queensbury,NY 12804 Arrive f(4)am/pm Depart am/pm Inspector's Initials o ' NAME: C ( / ° PERMIT# S LOCATION: g DATE : •!') r TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the place of the concrete. Materials for this purpose o ite Foundation/Wallpour Reinforcement in,PI Foundation/Dam fing Backfill Approv Plumbing Un r Slab Plumbing nt/Vents in Place Rough P1 bing -In -`- ---- 'otr ails Interior R- reht .----finuttdah Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Pror Vent, Attic Vent ng Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT -61 ,ram. Town of Queensbury Dept. of Community Development Date inspection request received: lc)--i `V Building& Code Enforcement 742 Bay Road • Queensbury,NY 12804 Arrive Depart t-r.‘ f:, Inspector's Initi NAME: AY 1 '171'1L' /6 Fyn yo5 5-tvre) PERNIIT# r 1 - — -�J LOCATION: i 3SSP2 `�t llc/i 1 DATE : Pro. 3 .� r. TYPE OF STRUCTURE: RECHECK igt,0 •V_� N/A YES NO COMMENTS Footings/Piers F I Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing p .tection from ing for 48 hou • following pl cement of the concre -. Materials for this ,urpo:• on s' Foundation/Wallpo Reinforcement in P . • Foundation/Dam.•roofing Backfill Approv. Plumbing Una- Slab Plumbing Ven ents in Place Rough Plumbing Heating Rou ation ‘(asFloandatio s Interior R- Foundation Walls Exterior R- Floors R- . . -'a. Walls R- P_ ' Ceiling R- o Duct work or piping in L unheated spaces R- Proper Vent, Attic Vent rFramingo RUA / Jack Stu �eaders �J� Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2. 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive /(,t) am/pm Depart am/pm Inspector's Initials Oh f NAME: 'L;ci - PERMIT# 471(Q 1 G LOCATION: (r e Q• DATE : Z x TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers I I Monolithic Pour Form Reinforcement in Place p c a The contractor is respo: ible fo "."./�fc`- CV ele providing protection • •m ing , ` for 48 hours folio •: the cement cr�M i..44 e•/e, , c r '��- el of the concrete. Materials for this p , • - •n site Foundation/Wal • Reinforcement in Pl. - Foundation/Dam•• , •fing Backfill Approval Plumbing Under S1:.: Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping Q00-)3f 1 TOWN OF QUEENSBURY n\, BUILDING b CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name C' 'VJ1Th 0.1\V-61-- Locati on ! 0\ C `\ 1 1 ,. ! Date / - ,-lx �� Permit # O - i SOIL TYP' Loam-Clay- Results of Percolation Test- (if applicable) Rate-Minute/Inch TYPE OF SYSTEM: (('''' t,If 1- ABSORPTION FIELD: Total LLength Length of each trench Depth of trenches Size of stone SEEPAGE PITS: N ,ber- Size - ft. x Stone size Ali PIPING: 141101111, ype'.` Bldg. to Tank 4 O To S� Tank to Dist. Box !1/ ' 2 3 Dist. Box to Fiel . • - Openings Sealed? dip No Partial LOCATION/SEPA' • II Foundation to Tank / 0 feet Foundation to Absorption _ feet Separation of Pits feet onforms as per Plot Plan No LOCATION OF SYS M ON PROPER (circl on ) Fron - Rea - Left Side - Right Side Middl nt - Middle Rear COMMENTS: -, )66: 14.< —1 ) ' 'i I ' ( ‘ fj e",e;-- ,,-, v 1 it - ,,,,,, %' > cbv,1446 it) 5X-10 Cc.6A-V— 0C- I ,) ��.(6 SYSTEM USE APPROVED: YES NO Arrived: Departed: ,_gc. ' Building Inspector FIRE MARSHAL �il TOWN OF QUEENSBURYNY12 QUEENSBURY4 (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED PERMIT# g% � NAME /,X;/ _//t4))/- LOCATION ; �_ `�2 /<i-`77 e, SCHEDULE INSPECTION ON AM PM ANYTIME APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING \ FIRE EXTINGUISHERS �,� 3/) FIRE ALARM SYSTEM / FIRE SPRINKLER SYSTEI FIRE SUPPRESSION SYSTEM __ HOOD INSTALLATION \ -� INTERIOR FINISHES STORAGE: CLEARANCE TO SPRI CLEARANCE TO HE I UNITS REQUIRED SIGNAGE CHIMNEY i WOOD STOVE 7 FIREPLACE-MASONRY - _ FIREPLACE-FACTORY BUILT REMARKS: D OK TO THIS DATE (}, cP,_/*///� / - y INSPSLIP.PUB INSPECTOR GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive /0 2 am/pm Depart am/pm Inspector's Initials NAME: PERMIT# LOCATION: p�J ca DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers F I Monolithic Pour Form � ,� ��f � C'B6/'� /�t�oe S Reinforcement in Place �L°��" The contractor is responsible for / providing protection from freezing /✓r 6 '✓�j for 48 ours following the placement of the crete. Materials fo this purpose on s' Foundatio alipour Reinforcement ' P1 Foundation/D oofing Backfill Appr al Plumbin nder Slab P1 ing Vent/Vents in Place R ugh Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Bather Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping %L GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive lea am/pm Depart am/pm Inspector's Initials ), - NAME: fner!c PERMIT# 7r-66/ LOCATION: / .£ DATE : 3 7 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place ��- "e The contractor is responsible for r4 providing protection from freezing r for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour FiFE mlace roo g Plumbing Under Slab Plumbing Vent/Vents in ace Rough Plumbing Heating Rough-I Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces ,R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL BUILDING CONSTRUCTION CHECKLIST Subchapter E Applications Owner: P'✓e,A,<11— Reviewed by: nor' Location: a (O Date: //) 0; Type of Work: I� Within Fire Limits: Date of Substantial Completion: Note: Topics listed in italics_ areavailable only to buildings which are 10 years or older. Is this a Minor Building ? See Table I-1233 Yes or No No Topic ' Code Required or Actual Section Allowed 1 Occupancy proposed 701.4 Fire Hazard Class 702 C 2 Construction Type 704.1 3 Height & Fire Area 705.4 Basic Area Tables 705 0Z2.3 Basic Height Accessibility 705.5b Sprinkler Increase 705.5c 10% allowance 1233.2c 3 Story wood frame 1233.2d 4 Space Requirements Ceiling Height 762.3 762.4 99 Existing Ceiling 1233.3b 7 r4 ,�,j 5 Light & Ventilation _ 763 �' Artificial Light 763.1 Natural Light 763.2rap► Ventilation 763.3 Existing 1233.3c 6 Special Stairs 764.1 ,,v4 • 61/14,06,,,j -X P`e trvrF Awl 114 C-1 1 No Topic Code Required or Actual Section Allowed 7a Exits Number 765.8 One Exit Permitted Tb X-765 •Units of Exit Width Distance of Travel Tb VI-765 Dead End Corridor 765.1j Enclosure Tb 1II-704 Existing Enclosure 1233.4c Corridor Width Tb I-765 Door Width Tb V-765 Existing Doors 1233 .4b Smoke Stops 765.2a Opening Protectives Tb 1II-771 Panic Hardware ' 765.5a4 Door Alarms 1060.9a 7b Stairways 765.4 Access to Roof 765.4a Dimensions Tb IV-765 Existing Dimensions 1233.4a4 Combustible stairs 765.4b2 765.4c3 Existing Comb. Stair 1233.4a2 Minor Bldg 1233.4a6&7 Handrails 765.4all 8. Safety Glazing 1766.1 9. Garages and•Parking 767 Structures 10 Malls and Passageways Passageways 768.1 Malls 768.2 11 Atriums 769 Existing 1233.8 12 Exterior Fire Spread Part 770 Distance Separation Tb I-770 Existing 1233.5b Tb IV-1233 Construction Limits 770.2c&d Type 4b & 5 1233.5c Party Walls.. 770.6 Parapet 1233.5a Finishes 770.8 f v1t V ` No Topic Code Required or Actual Section Allowed s�.. 13 Interior Fire Spread Part 771 / At- Fire Separation Tb II-771 Mixed Occupancy - 771.4a6 .Allowable Mix 1233.6b - Openings 771.41 Existing Openings 1233.6a Fire Stopping 771.5c 14 Interior Finish -772.2 Existing 1233.7 15 Plastic Materials Part 773 Part 1120 /4k,, Existing 1237.3 • 16 Fire Protection Equip Fire Alarm System 774.2 Zoned System 1060.2a5 Battery Backup 1060.2d1 Pull Box travel Tb I-1060 Fire Dept Connection 774.lb Detection system 774.3 Sprinkler System 774.4 Standpipe System 774.5 Yard Hydrants 774.6 Watchman System 774.7 Auto Vent Alarm 774.8 Coodinated Fire Safety 774.9 17 SPECIAL HAZARDS Areas of Pub. Assemb. Fire & Smoke Det. 791 Sprinkler System 792 Gas Pumps 774.10 1231.3e Emergency Ventilation 1004.2f Fan Shutdown 1004.2e l( Exhaust Hood1System 1064.2b 18 Design Loads Snow 803.3 Floor Tb 111-803 Wind Tb V-803 f 1 Tb VI-803 Existing Adequate 1237.2 &Lit. R'E< iy►✓dG h z Tai 7`�Cihdr fc f� " /1.c lu•.f�, t" " " C-3 No Topic Code Required or Actual Section Allowed .c---- 19 Plumbing / Fixtures 900.2 �s� Cr, 904. E C4r// _Freezing 850.7 Existing Adequate 123 7.1 20 Heat Producing Equip. Prohibited Locations 1000.2d Enclosure 771.4j Air Supply 1000.2g Vents and Chimneys Prohibited Uses 1005.2 Outlet Location Tb I-1005 Existing Adequate , 1237.1 ' 21 Electrical Metal Veneers 1030.1g 1 Emergency Power 1032.2 Emergency Lights Tb 1-1032 N,/ Exit Lights 1033 Existing Adequate 1237.1 22 Accessibility A117.1-92 - Exterior Facilities 1101.1 Interior Routes 1101.3 Interior Elements 1101.4 Areas of Refuge 1101.5c Assembly Space 1101.6 Specific Occupancies 1102 E`xi-sting(,Bui1ldings Part 1236 Jam-( C,-C�L (.0.),i le- N,c.. �1rt'pJii..; l<c d.0 tirds r (.t,ti. 'j 23 Energy Requirements Energy Code Certification 7810.10 4 47A.o� ��FI sV /41,1% 4 ,74./3 ri---y A �,� m �t�t 000"'� i y� £/ tt t dC�c t+ l�inn /VQeis . ill • . • C-4 i