Loading...
2007-739 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20070739 Date Issued: Friday, November 14, 2008 This is to certify that work requested to be done as shown by Permit Number P20070739 has been completed. Location: 25 CEDARWOOD Dr Tax Map Number. 523400-296-009-0002-023-000-0000 Owner. JOSEPH & CLAIRE TROMBLEY Applicant: JOSEPH & CLAIRE TROMBLEY This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUE E NSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070739 Application Number. A20070739 Tax Map No: 523400-296-009-0002-023-000-0000 Permission is hereby granted to: JOSEPH &CLAIRE TROMBLEY For property located at: 25 CEDARWOOD Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH& CLAIRE TROMBLEY Residential Addition $10,000.00 25 CEDARWOOD Dr Total value $10,000.00 QUEENSBURY,NY 12804 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2007-739 68 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,December 10, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T of eens g� jdlj"�;�; '�0�°d , ecember 10,2007 �. . r SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ,.._..-- -.... ___._-.- FFICE USE ONLY................................ __-__- _- ,------- 0 01 TAX MAP NO. PERMIT NO. z2 0 0 FEES: PER RECREATION ENGINEERING % % " . (. applicable}__.___../ _.,-_,_ ._•_..-�--.-._. PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. /� APPLICANT/BUILDER:,EU7'L✓�� /�IICT/v� OWNER:✓DSEP9-f CAAMFE lftm 3LEV 33a?au..c � Ave'p z C��RRx M--bg1.1e. ADDRESS: dR}� /V Y ADDRESS: Lly 12jyoq_ tw" �SS-0357 3 qo/S PHONE NOS.PAk � PHON OS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 11I7z APHONE: gSS 035'7 LOCATION OF PROPERTY: a ��d L`T i���►��' SUBDIVISION NAME: �1�`}L L L'c' , of /3 rw y4:,et„'acus t-ec.,' 12:f PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p a w u- APPLY TO YOUR ZQQ _� O OO O PROJECT O i a- . U. �==z n Z Q 04 Cr,cr, sa t F GLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: �" DWo FUEL TYPE: --- 4044S43 P40,6AND/OR WOODSTOVES(S):__!�' ____ HEAT TYPE:Mff W,07 ?"HOW MANY FIREPLACE(S):_ d_ _. ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? Z4 Q IS THIS A HISTORIC SITE? Azo ---� PROPOSED USE OF BUILDING OR ADDITION:_ itl�Q� ?`� 2�'� *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 0- Town of Queensbury • Community Development Office • 742 Ball Road, Oueensburu, NY 12904 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above.Signed Lti:��6 -S Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ...............................I "__ . _______._......""".._.. 1 , 1 1 , , Permission is hereby granted to the above s This application / proposed action described Applicant to erect or alter the building ; herein is found to be in accordance with the01 described herein in accordance with said Soo zoning Laws of the Town of Queensbury. Application: ; 10 I 1 1 , , , 1 1 1 1 1 1 i , 1 1 1 1 1 1 1 1 1 1 1 1 , 1 , 1 1 1 1 / 1 / BUILDING & CODES APPROVAL "0 0 ZONING APPROVAL 11 1 1 1 1 1 1 1 1 / 1 1 1 1 DATE ; ; DATE 1 1 I 1 / (QUESTIONS? CALL 761-8256 OR EMAIL codes(ftueensbu rv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes No www.queensbu!y.net Occupancy Type: K� Construction Classification: Assembly Occupancy Limit: _ Special Conditions: Tozvn of Queensbunj • Community Development Office • 742 Bay Road, Queensbury, NY 12804 h - Community Development Office 07141 ofQm'wtsbury • 742 Reel Road• (�nr:nsburu, .`d ;i 1r� .IZ fI� wxlvDow SCHEDULE ��(( '/ JOB SITE/ADDRESS: aS ��� �iIIQ;�D cU ��� DATE: OWNER:, DSE/�f� .� //CE fflGlN9Bl{"r APPLICATION NO.: UNIT OR 1INDOW CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. CLEAR OPENING NO.OR WINDOW SQ.FT, OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESSICLEAR HEIGHT LETTER NAME MODELITYPE CALL WIDTH HEIGHT VENT OPENING WIDTH IN IN INSTRUCTIONS ON PLAN SSE INCHES INCHES r�r�✓in,� 3W -qe, ZV iZ 3.8' `/. 2a � Ar p TkTw.1 aR -/ W)Y DOS A(A /T w 4/�J i i I P ! 1 B?G-I.TR 11-05 ----------------------------------- OFFICE USE ONLY PROJECT NAME: STAFF INITIALS: BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: ------------------------------------- SINGLE FAMILY DWELLING ............ 1. Building Permit Application Completed? YE NO N /A 2. Energy Form or CheckMate Energy Code Compliance Forms Complete?(2-copies) Energy Code Inspector's Report from Checkmate Energy 3. P I rogram? (2-copies) ✓ 4. Sep tic application completely filled out? I (if applicable) .................................-.................------------- 5. TElectrical Inspection Form complete? V/ 6. j Two (2) sets of the plans each of the following: YES NO N /A a. Floor plans (s)? V/ b. Foundation plan? c. Cross sections (s)? d. Elevations? ___.__---..._.__.._.--..______.._...__._a_.._.._._..-__.__.__ e. Window and door schedule? g. Plans signed and sealed by registered architect or engineer? h. Window and door schedule? Two (2)site plans showing location of the structure to be 7. built, location-ofAvelt-or-vvater line location..of septic sltEe -or sewer-hrie?-- 8. Setbacks from property lines to new structure? 8. Setbacks to neighboring wells and septic systems, including onsite well and septic systems (if applicable)? T 9. Driveway Permit? V/ Town of Queensbury- Community Development Office - 742 Bay Road, Queensbury, NY 12804 PROJECT NAME: OFFICE USE ONLY STAFF INITIALS: BUILDING PERMIT SUBMISSION % DATE: CHECKLIST FOR: ' MULTIPLE DWELLING or COMMERCIAL PROJECTS 1. ! Building Permit Application Completed? YES NO N /A �Forms .__. .. .............2. gy Form or CheckMate Energy Code Compliance Complete? (2-copies) Energy Code Inspector's Report from Checkmate 3. Program? (2-copies) r--- ' Septic application completely filled out? 4' (if applicable) 5. Electrical Inspection Form complete? 6. Two (2) sets of the plans each of the following: YES NO I N /A� I f a. Floor plans (s)? b. Foundation plan? c. Cross sections (s)? I d. Elevations? e. Design loads including floor, snow load, and wind load? f. Seismic design (required after January 2003)? —j g. Plans signed and sealed by registered architect or engineer? _ i � 1 I h. Window and door schedule? i ! i Two(2) site plans showing location of the structure to be built, location of well or water lines, location of septic 7' system or sewer line with all setbacks and separation distances shown, and all improvements to the property? i 8. Solid Fuel Burning or Gas Appliance Form (if applicable)? E f I 9. Driveway Permit j Town of Queensbury• Community Development Office • 742 Bay Roml, Queensbury, NY 12804 t Coygntt1Uty Deyelopyient Off c Twon of Quecusbury• 742 Bay Rd. r Queensburil, Nezv York •12804 PLOT PLAN Show all existing and proposed structures. Indicate the setbacks of all structures and buildings from all property lines. SIDE PROPERTY LINE 1-37 ` � W � v7 v z �( z k LLI \ 0 p p. Ul p �dd r W Z m 137 � SIDE PROPERTY LINE 1 SQUARE = FT. 7-6137 y : 101 0,4 Z- a , � r '*a t'S < Litt t F)v BU NAME of 500UivtStc>t T I W OW%-4t R-.5 — V.C. Ich , E.C.TvitcvAEt_L C w !i I I U�t ��Fistir 1J'hc�DtJ r��� fit }�« U1+r ;,. W CIO (,* t� 4 rcrna�?� cl y F OOYW(n � . ..� J44 fp•eL i � 'a..L �� ck 3�Q _ ��I jS�►�t1 1�e.�i Do+rt C 1+L/Ck*-l0Yti LSy%bW* V j � 2 K`G Y"A��•Ily(. �XrS1tn CD03r };ts 930 r � ( ; J �,:•�-.cr 'tom. l(J ci(Uf iJ.t ,ram q� �p fCi�G',n Lj z try✓S JF Y'4�� c • • � ,. i11P' 'ZI�l F 1 Queensbury Building & Code Enforcement - Re ential Final Inspection Office No. 518 761-8256 -, ( ) Arrive: ,�,�aml= Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Com fete/Exterior Finish Complete Iff Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wail Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Fumace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Game fire roofin /%hour fire door/door closer Duct work Sealed Properlv Gas LW*in Sealed or GlaslEndbsure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept, Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent L.\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 a , MIDDLE DEPARTMENT INSPECTION AGENCY, INC. that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Joe Trombley Date: 11/12/2008 Occupant: House Location: 25 Cedarwood Occupancy: Single Family Dwg. Queensbury, Warren Co. NY Applicant: 7 Joe Trombley a. w 25 Cedarwood woe OF Queensbury,NY 1.213 (— �� J Raymond A. No�k m No. -- —- 31804 - - Equipment: 11 - Switches; 16 - RecepAples, 1 , FC ecep ace; Fixtures, 1"=wryer, 1 - mp. eptacle; 1 - Ceiling Fan �^ This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency, Inc. An application for inspection must be submitted to Middle ed to, the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. /1 UJ Y -(U Rough Plumbing / Insulation Inspection Re ort Office No. (518) 761-8256 Date Ins ct' guest received: l 02 o Queensbury Building & Code Enforcement Arrive: S am/!JJ _ epart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: vv NAME. /T) PERMIT#: LOCATION: 02_ Pcxs INSPECT ON: TYPE OF STRUCTURE: � v l Y N NIA �R,ough Plum in /Nail Plates P um in ent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum leanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces CorWustion Air Supply for Furnace D ct work sealed properly/No duct tape Y�✓�i�l� COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 aTr4&,A-C jj Rough Plumbing j Insulation Inspection Rep,go rt Office No. (518) 761-8256 Date Inspect' �r est received: ma s Queensbury Building & Code Enforcement Arrive: am/pm D art: am/pm 742 Bay Road, Queensbury, NY 12804 Insp or's Initials: A4 NAME:_ PERMIT #: 07�7 LOCATION:_ INSPECT ON: fd TYPE OF STRUCTURE: Y N N/A Rough-Plumbing Nail Plates 617-c�- Cull Plumbing Vent Vents in Place Qv 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection FormsURough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Rough Plumbing / insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ art: i , am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 0 PERMIT #: 077— LOCATION: INSPECT ON: F -- 5`'- �'' TYPE OF STRUCTURE: Y N N/A Rough Plumbing/Nail Plates Plumbing Vent I Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping 50 P.S.I for 15 minutes Insulation IAPsidential Check/Commercial Check Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: -2A Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Repo Office No. (518)761-8256 E:M:is Queensbury Building &Code Enforcement part: am/pm 742 Bay Road, Queensbury, NY 12804 NAME: PERMIT#: LOCATION: INSPECT ON: — — TYPE OF STRUCTURE: Y-1 N WA COMMENTS: Framing c ccess 22° x 30" minimum Jack Studs/Headers Bracing f Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches f Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses t�chor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in paivity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-01.131Building&Codesunspedion Fams\Fmn*q Firestopping inspection ReporLdoc Revised January 7,2008 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:,A_ NAME: PERMIT#: +Q LOCATION: f7 INSPECT ON: TYPE OF STRUC . Comments Y N NIA Footings Piers Monolithic Slab Reinforcement in Place The contractor is respo ible for , providing protection m freezin R" for 48 hours following a placeme t of the concrete. Materials for this p se on site. Foundation/Wallpour " Reinforcement in Place Footing Dowels or Ke mty in place Foundation Dampproofu Foundation Waterproofing Footing Drain Daylight or Sum Footing Drain Stone: 12 inch width 6 inches above footin 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Bullding&Codes\Inspedtion Forms\Fou Inspection Report.doc Last printed 12/20/2005 9:24:00 AM s IUO l Vlc °r/'� Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart-2 rbn am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: A� NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 mil poly for wet areas under slab royal Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM p �, - to Q Foundation Inspection Rep Office No.(518)761-8256 Date Inspection request received: (0 la 6FF Queensbury Building&Code Enforcement Arrive: am/pm Depart. \7 am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: Er / NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRU �Tt �``� _" Comments Y N N/A Footings N J Piers + , Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. s purpose on site. po Reinforcement in Place Footing Dowels or Keyway in place oe Foundation Dampproofmg Foundation Waterproofing r ` Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM �0 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Q-r D 9" Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Rd.,queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: - 739 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footin Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. U Building&Codes Forms\Building&Codes\lnspecdon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report �1 Office No.(518)761-8256 Date InsM%on�e„quest received: Queensbury Building&Code Enforcement Arrive: pm epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: '��'�f 'C r�.4!. ? PERMIT#: LOCATION: 2 -4p,4) e -'&,q 0 R INSPECT ON: 6 0 7 TYPE OF STRUCTURE: Comments Y N N/A c �� U &s'- Footings Piers Monolithic Slab Reinforcement in Place t h(l 1/ "N The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspecdon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1 y 07 ' Generated by REScheck Package Generator Compliance Certificate Project Title: Trombley Addition Report Date: 11/01/07 Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 5% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 25 Cedarwood Dr Trombley Patrick Burke Queensbury,NY 12804 Patrick Burke Construction Inc. 936 Bay Rd Queensbury,NY 12804 518-222-9765 pat@pbcatwork.com Compliance: 777 Assembly Cavity R-Value Cont. R-Value Glazing . Door U-Factor Ceiling: 38.0 Wall: 21.0 0.0 Window: 0.300 Door: 0.350 Floor: 30.0 Other Boiler.80 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Name-Title Signature Date Trombley Addition Page 1 of 4 Generated by REScheck Package Generator Inspection Checklist Date: 11/01/07 Ceilings: ❑ Ceiling:R-38.0 cavity insulation Comments: Note:The ceiling R-values do not assume a raised or oversized truss construction.If the insulation achieves the full insulation thickness over the plate lines of exterior walls,R-30 insulation may be substituted for R-38 insulation and R-38 insulation may be substituted for R-49 insulation.Ceiling R-values represent the sum of cavity insulation plus insulating sheathing(if used). Above-Grade Walls: ❑ Wall:R-21.0 cavity insulation Comments: Note:Wall requirements apply to wood-frame wall constructions.Metal-frame wall or mass(concrete,masonry,log)wall equivalent R-values can be found in the Help User's Guide. Windows: ❑ Window:U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Note:Up to 1%of the total allowed glazing area may be excluded from the U-value requirement.For example,3 ft2 of decorative glass may be excluded from a building design with 300 ft2 of glazing area. Doors: ❑ Door:U-factor:0.350 Comments:Front door exempt Note:Door U-values must be tested and documented by the manufacturer in accordance with the NFRC test procedure or taken from the door U-factor table in the Help User's Guide.If a door contains glass and an aggregate U-factor rating for that door is not available,include the glass area of the door with your windows and use the opaque door U-factor to determine compliance for the door.One door may be excluded from this requirement(i.e.,may hav a U-factor greater than 0.35). Floors: ❑ Floor:R-30.0 cavity insulation Comments: Note:The floor requirements apply to floors over unconditioned spaces(such as unconditioned crawlspaces,basements or garages). Floors over outside air must meet the ceiling requirements. Note:Add an additional R-2 for heated slabs.The insulation must extend 1)down from the top of the slab,or 2)down from the top of the slab to the bottom of the slab and then horizontally underneath the slab,or 3)down from the top of the slab to the bottom of the slab and then horizontally away from the slab,with pavement or at least 10 inches of soil covering the horizontal insulation. Heating and Cooling Equipment: ❑ Other Boiler::80 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: Trombley Addition Page 2 of 4 Ll Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment are installed in accordance with the manufacturer's installation instructions. Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R-values and glazing U-factors are dearly marked on the building plans or specifications. Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Lj Supply ducts in unconditioned attics or outside the building are insulated to R-11. Return duds in unconditioned attics or outside the building are insulated to R-6. Lj Supply ducts in unconditioned spaces are insulated to R-11. Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: Lj All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Lj The HVAC system provides a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Fireplaces are installed with tight fitting non-combustible fireplace doors. Lj Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. El Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Ll All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: LI HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Trombley Addition Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature("F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Trombley Addition Page 4 of 4