Loading...
2003-190 QUE TOWN OF E NSBURY cow742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20030190 Date Issued: Monday, July 27, 2009 This is to certify that work requested to be done as shown by Permit Number P20030190 has been completed. Location: 1689 RIDGE Rd Tax Map Number. 523400-266-001-0002-015-000-0000 Owner. JOHN & ALICE BRUHNS Applicant: JOHN & ALICE BRUHNS This structure may be occupied as a: Garage - 2 Cars Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the4 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY iT*AT 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030190 Application Number: A20030190 Tax Map No: 523400-266-001-0002-015-000-0000 Permission is hereby granted to: JOHN & AT,TCE BRI JHNS For property located at: 1689 RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Owner Address: JOHN & ALICE BRUHNS 1689 RIDGE Rd QUEENSBURY,NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency MI INNS. JOHN 1689 RIDGE ROAD OIJEENSBTJRY_NY Plans&Specifications 2003-190 483 SQ FT 2-CAR DETACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $48.30 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,April 29, 2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of uee ty,� u 1 April 29,2003 �d SIGNED BY t for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 • (7 ^1 Q./6 A permit must be obtained before beginning construction. Permit File No. ;DPAS � No inspection will be made until applicant has received a Fee Paid $ valid building permit. All applicants' spaces on this Rec.Fee Paid application must be completed and must appear on the Reviewed B /.PPrr1 application form. Applicant: '`)0/4,` S Owner: ' Address: f�G. ,e "d, Address: I gi , 9.550 z 5.�v�- Y - `�� Phone#(_) - � � Phone#(_) OP C u:~ Property Location: Lot Number: / House Number / t I7 mod, Subdivision Name: Tax Map Number: ❑ New Building: residence /commercial Estimated Market Value of Construction:$ G/6 � o Addition: residence/ commercial If an Addition,what will use of new addition be? Alteration: si•ence►commercial �AQ,4 l o No change to exterior size: residence/com'l o Other work(describe ) Check Occupancylnformation 1"Floor 2°d Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet o Single family dwelling o Two family dwelling o Townhouse o Multifamily dwelling #of units ❑ Office o Mercantile o Manufacturing ❑ 1 car detached garage AK car detached garage 1 '3 , (fi O 3 car detached garage u 1 car attached garage ❑ 2 car attached garage ❑ 3 car attached garage o Storage building- commercial ❑ Storage building- residential • ❑ Other / What is the proposed height of the structure ? feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed C Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder & Z,ec.., it.v S -- .A/44.-P 77 ? 7 Plumber Mason ,j/h,`e A lc/ C /31G 54 7 keo. Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Dir •r of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all ' • cons' tion. Signature: i owner,owner's agent,architect,contractor Queensbury Building & Code Enforcement - Residential 'na pection Office No. (518) 761-8256 Arrive:• t . ��+• ter`;;rt: Date Inspection request received: Inspector's Initi- NAME: de,NZ B RM #: f — LOCATION: PNO r 'T-. —7 7--U9 TYPE OF STRUCTURE: Comments: NA 4" Building Number Address visible from road Chimney Height/"IT'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate — Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed I Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing I%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C I O[Tempor ry/Permanent] 2) L:\Building&Codes Forms\Building&Codes\Inspectioon Forms1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: - rt: am/pm Date Inspection request received: Inspector's Initials: �, NAME: k1 P IT#: / 3 /7r) LOCATION: (�` ,� /P D E: ( ..— tom—09 TYPE OF STRUCTURE: Comments: Yes No ' N/A /z ci/c 4" Building Number Address visible from roadevcp 4 ��1�Y1( Chimney Height/ fr Vent/Direct Vent Location _ Fresh Air Intake7/1- 7 - _ 3 inch Plumbing Vent through roof minimum 6 inchesmp Complete �� , Roof Complete/Exterior Finish _c-' Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more A i-V V Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet F V \-\ ► i wlh;pl, 6 inch clearance to sill plate C)Q- iaHF ANAiN ,, Cz, Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation I Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/.hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure _ Final Electrical Final Survey Plot Plan - Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker Site Plan I Variance required Flood Plain Certification,if required Okay to issue C/C or C I 0(Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 Queensbury Building & Code Enforcement - Resi s - tial final Inspection Office No. 518 ( )761-8256 Arrive: -.art: am/pm Date Inspection request received: Inspector's Initia s: ar NAME: LOCATION: A S P .'� IT#: 03'-170 TYPE OF STRUCTURE �� D 'Ita�C$ (9arex).€ Comments Yes No N/A Building Number/Address visible from road f Chimney Height/"B"Vent/Direct Vent Location c//j Fresh Air Intake / �Y 3 inch Plumbing Vent ouch roof minimum 6 inches �� �! "Q/Ced Roof Complete/ 'xterior Finish Complete �/ G Platform ail exterior doors /-7 ( �� 3/I4Guards at stairs,decks,patios more than 30 inches above grade 7 Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more ie / cz _ Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches 2- Or Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Pf\ov3 _. Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: " F% .1-V Carbon Monoxide Detector -1-1A 6 p�r t� SAD Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents t-1/41•-\EZ Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. M R� ` C���9�Q Emergency egress below grade `1 f9\ Gas Furnace shut-off within 30 feet or within line of site Q t• u v 0E Z�-M 1 t V Oil Furnace shut-off at entrance to furnace area • Furnace/Hot Water Heater operating t 1 N ��-, 4 Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Farm revised_100405.doc 511. Queensbury Building & Code Enforcement - Resi ial Fi Inspection Office No. (518)761-8256 Arrive: - m am/pm I ,/t Date Inspection request received: Inspector's Initia s: v NAME: a r r- v�it4 ( E: #: rTh S- TYPE OF STRUCTU : ��o - v`Cc' Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent t miniuuam6 inches Roof Complete/ terior Finish Complete ✓ f� �� Platform at all exterio Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft. vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain.Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised 100405.doc Queensbury Building & Code Enforcement - Re '. - 'al F. al Inspection Office No. (518)761-8256 Arrive: j: '�. �. • 1-1r) � � D•�art: • .� i��' Date Inspection request received: LL Inspector's Initi NAME: C \--�'J PE• IT#: `0t 3 —190 LOCATION: Lp P' D C-,E O 1R V) D TE: TYPE OF STRUCTURE: J ETf C- F Q C-,A,P�1PC Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete') �1L—T E 9 \Uc IJ -EQb \ t Platform at all exterior doors BE_ PF't \E.0 0 9\ .6 IN ) Guards at stairs,decks,patios more than 30 inches above grade c] �C�E \1 jf�' 'z ct Guard at stairwell at 34 inches or more 4� Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%x"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker _Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc ` ,Queensbury Building & Code Enforcement - Re '•e tia al Inspection Office No. (518)761-8256 Arrive: am/p - �-.art: i�( am/ m Date Inspection request received: Inspector's Init..ls• „ rl NAME: —,NilfkV“\"4 -'? cz : RMIT#: ... � 9�JLOCATION: a ATE: 1TYPE OF STRUCTURE: vi�ic� 6 1:7- C am Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete � Guard 30 in.or more @ stairs,decks,patios 0 iJ Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 'h" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors I main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing I' hour fire door/door closer I Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Framing / Firestopping Inspection Report er v i Office No. (518) 761-8256 Date Inspection reque receiv : Queensbury Building&Code Enforcement Arrive: a p art: \ \ � • 742 Bay Road,Queensbury,NY 12804 Inspector's Initial • NAME: =r-e,-()\, __. :›S-\A`,:\C\_,Q PERMIT#: O 5T / 9,0 LOCATION: r INSPECT ON: / _03 TYPE OF STRUCTURE: cN 8_, Y N N/A COMMENTS •� raming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly VJ 12"O.C. N� Headroom 6 ft. 8 in. Stairwells 36 in. or more U� +�\' Headroom 6 ft. 8 in. -\UU \_ • Notches/Holes/Bearing Walls t \ �� Metal Strapping for Notches Top Plate AN) 1 V2(w) 16 gauge (8) 16D nails each side c.., -� �� dd Draft stopping 1,000 sq. ft. floor trusses d`' �" \h' Anchor Bolts 6 ft. or less on center ✓ cL ` �� Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Ha;� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 - / 0 Foundation Inspection Report 1 Office No. (518) 761-8256 Date Inspection request received: _ Queensbury Building&Code Enforcement Arrive: am/ �j,-�//'' Depart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: (P, 1�� NAME: A '(\` ` `; ' PERMIT#: C) — / n i LOCATION: c:r r \ _ . !(� y__ (�! INSPECT ON: TYPE OF STRUCTURE: - Comments Y N N/A Footings Pier • onolithic Slab Reinforcement in Place a / The contractor is responsible fo rv/ providing protection from freezi g for 48 hours following the placement of the concrete. Materials for this purpose on site. 1 Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 (f `/COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. /—�, Main Office 176 Doe Run Road-Manheim,PA 17545 L/ `CI MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL IJN 1N kin nr, 'ermit No .ii.r- Cert. N 9 U I U 7 Cut-in Card No. )wner �.l ' eel( 1. .ocation ! g ! nstallation Consisting of..6 4 c r.P Q' ic.'.e../ fif2xr nstalled By .k/144. Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ntroduction of additional equipment or alterations,application shall promptly made for inspection. Inspectors of this Company shall have the privilege of mak g i spections at any time, and if its ules are violated,the Company shall have the right to r v ke th' certific i. )ate —�—t3 7 INSPECTOR Member N.F.P.A.,I.A.E.I. 22 '----4:2 " 1 i I 4--------- 1 i1 1 i ; 1 1 1 I , 1 I 1 i! .., ; 1 1 i I tiii , 3 J 1 i LI ,, , j:HI I) iNli , : I ' 1 , - ' P i ii C:i i 1 ,:.....:i--' <I' i I1 ' I I 11 . di 1 71 1 , 1 i i ,- t i t , I 1 1i „,.. I - 1 '1 Ni ' , , ,..../ , i CI . i ii ,......' !, I c,.-Ze.--5" 'X- -1 .-e,..-7-," -... .)-V.7-11 )-2... . C;2.4-,: -D‘.V..---7 .--2-..D 4 :).1.-k . .- 7.cZ,,• 1 MIII . t / \ 4 J 4 ,.._--' ,,.. +fir yy , . f, �,,...., ...�,.�u�.,.:r�«w:«:,,o.,,.r..�n•�.,+,n,..._..e,�,.-�:.,.,..,..,�.....�,:.� ..,....,.....µ....,»,.._..--a+-. �S ... ABM.- ,'',`' ... ....,- 1, ,...., 4 1 ,,,,,,,,,,, -;,_ .,,,,"� �' ,), , ife, . R � ___._._._.___ r`F dEC)„ __ pg '11,b 1 If �pp yk({k 9 1 ... , k9n4AYnewtLNS.~91 "�!� /✓ / / J' i"...�� „, lI / .)s/,f/Z z j., —, ±V.9 p/ S - ..21/d x X '-"F. , 'y-fr _--) / 4 'L /