2005-003 i TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (JF OCCUPANCY Permit Number. P20050003 Date Issued: Wednesday, January 31, 2007 This is to certify that work requested to be done as shown by Permit Number P20050003 has been completed. Tax Map Number. 523400-295-020-0001-007-001-0000 Location: 19 FOX FARM Rd Owner. ERNEST & NANCY STEVES Applicant: ERNEST & NANCY STEVES This structure maybe occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the J, / 6 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&CocYe Enfo ement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20050003 Application Number: A20050003 Tax ivlap No: 523400-295-020-0001-007-001-0000 Permission is hereby granted to: ERNEST &NANCY STEVES For property located at: 19 FOX FARM Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ERNEST &NANCY STEVES Residential Addition $10,000.00 19 FOX FARM Rd Total Value $10,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-003 490 SQ FT WORKSHOP $38.40 PERMIT FEE PAID -THIS PERMIT EXPIRES: Sunday, January 21, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the own o s ur� r' a January 21, 2005 SIGNED BY � uee V for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050003 Application Number: A20050003 Tax Map No: 523400-295-020-0001-007-001-0000 Permission is hereby granted to: F,RNF,ST &NANC'Y STF,VF.S For property located at: 19 FOX FARM Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ERNEST &NANCY STEVES 19 FOX FARM Rd Residential Addition $10,000.00 Total Value $10,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-003 480 SQ FT WORKSHOP $38.40 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday, January 21, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Friday, January 21, 2005 SIGNED BY for the Town of Queensbury. r t ui NEnforcement Building Permit Application 'E Town of ueensbu ry—De t of Community Dcvelo men�742 Bay Road,Queensb�Y,NY(518)761.8256 !u t F� My Npermit erection will be made untilapplicant beginning has rocei ed a ction. Permit File No. "0/ND 4�� 6o URY pFoe Paid $ 6 DE valid building permit. All applicants' spaces on this Rec.Fee Paid $ application rnustbe completed and must appear on the Reviewed B application form y' Applicant: 1�jPft/c_.j� Owner: �c Address: 9 Address: ft 4, A1Y 1-2 k-41�K- QJJI,,,,��,6rw,., g /VX- -1.2 C,q, Phone# zi- Phone#(4210 2f�- Property Location: Lot Number: House Number %q / �3c 7& .w � Subdivision Name: Ti; Map Number: -.2 qs- . t o New Building: residence /commercial Estimated Market Value of Construction: $ }$ Addition: real a -,jPommereial If an Addition,what will use of new addition be o Alteration: ms commercial !d?C -L�..�S�a. C No change to exterior size: residence/com 1 v Other work(describe Check OccupancyWormation 1' Floor 2 Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet cl Single fimily dwelling o Two fim3fly dwelling v Townhouse 1Z �D o Multifamily dwelling #of units DEC 1 04 o Office 10 o Mercantile I I ®�y Manufactutin o i car detached prage a 2 car detached em a 3 car detached prage O 1 car attached garage o 2 oar attached pmp - a 3 car attached garage o Storage building- commercial o Storage building- residential c Other We 1{ 2 What is the proposed height of the structure l feet „�o _inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System electric/ o*2:ii3xvood / orced hot air baseboard/other: Number of Fireplaces to be installed C2 Number of W odatoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder i . /71 6C 6 3 Plumber Mason Electrician peclaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an as Built Survey by a licensed surveyor;drawn to scale,showing actual location of all natruetioq.- Signature: /!/ owner,owner's agent,architect,contractor Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: Iam/pzn pepart: am/pm Date Inspection request received: Inspector's Initials: .J- NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: �` Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade (DK Q Guard at stairwell at 34 inches or more Guard at deck,.porches 36 inches or more Handrail Termination at Newell Post or Wall C O(> 0 Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches 1, Bathroom/Kitchen watertight -! Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft. vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc BI L E Bldg. Permit File No. a66-603 Final E Inspection Approval COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit Nol � ....Cert. N'_ 93343 Cut-in Card No..................................... ............ ................... Owner..................1..n 12. :,?.%............ .l.s~.u.. .. ................................................................................... Location...........1..c1. ........................ .us: .�? 5:..!✓..4 :?. ........... Installation Consisting of..... ...... ........1az..... may........... .......... ........4...T....S........................................................................................................................ .................................................................................................................................................................................... InstalledBy.....,.A.rx.2.0 .................................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date.............. ........... INSPECTOR....�fer. ... ��......................... Member N.F.P.A.,I.A.E.I. Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive• � �am/p D art: am/pm Date Inspection request received: _ Inspector's Initials: NAME: PERMIT#: LOCATION: DATE:TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,_patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical ( � ��� — Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc o_ Framing / Firestopping Inspection Report -` ' Office No. (518) 761-8256 Date Inspection request received: 3 U Queensbury Building& Code Enforcement Arrive: _am/p eeppart: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Sy ' NAME: PERMIT#: , LOCATION: c r,, (,_- INSPECT ON: TYPE OF STRUCTURE: 14 / Y N N/A COMMENTS Framing, Jack Studs/Headers Bracing/Bridging Joist hangers D �� Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: an ea. am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ' cc- PERMIT#: LOCATION: o rA_rW_t#_ _ INSPECT ON: '-7 2,0 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing F ��� Jack Studs/Headers /141 ej jA-Z.z— ('j�,(r Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. -^— Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. J J Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate �2vU �� 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses/An chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L\SueHemingway\BuiIdin&Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 AN1 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: — Queensbury Building& Code Enforcement Arrive: am/ epart: am/pm 742 Bay Road, Queensbury, NY 12804 Jnspector's Initials: -- it f f� f/ NAME: ���� �j/'t�� PERMIT#: -c6 3 LOCATION: i Fk INSPECT ON: a TYPE OF STRUCTURE: I Framing Y N N/A (/ COMMENTS ac Studs/Headers Bracing/Bridging I c� Joist hangers L� �exo 6ie� Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms , 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 � � Foundation Inspection Report Office No. (518) 761-8256 Date Inspection!25 d: Queensbury Building &Code Enforcement Arrive: Depart: a 742 Bay Rd., Queensbury,NY 12804 Inspector's InitiNAME: t Q 5�_�-�J LOCATION: , x- INSPECT ON: Ca TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab T VITM Reinforcement in Place � TZ� The contractor is responsible for ,t� providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width inc es above footing 6 poly for wet areas under slab _ ckfill Approval Plumbing Under Slab VC/Cast/Copper Foundation Insulation 'o erior R- t� _ Rough Grade 6 inch drop within 10 ft. L\SueHerningway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/gAgC Depart:-// ami,pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials- PERMIT _ T#: � �D NAME: N� LOCATION INSPECT ON: TYPE OF STRUCTURE: �7 r Comments —_ Y N N/A ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible�or , providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORNIS\Foundation Inspection Report.doc January 29,2003 ® Permit Number Checked By/Date Generated by REScheck-Web Software Compliance Certificate Project Title: workshop Energy Code: 1995 MEC Location: Warren County,New York Construction Type: Single Family window-to-wall Ratio: 0.02 Heating Decree Days: 8499 Report Date: Date of Plans: Project Informatkrrr: Builder Iniomration: 16x24 addition on side of garage for a workshop.Will be self built on slab. Compliance:Invalid U-Factor(s) Maximum U& Your Home U& Wall 1:Wood Frame,16in.o.c. 560 19.0 0.0 32 Window 1:Wood Frame,Double Pane 12 0.000 0 Door 1:Solid 21 0.000 0 Floor1:Heated Slab-On-Grade 56 0.0 58 Ceiling 1:Flat or Scissor Truss 388 30.0 0.0 14 Fumace 1:Forced Hot Air(Non-Electric):78 AFUE Generated by REScheck-Web Software REScheck Inspection Checklist Project Title: workshop Ceilings: ❑ Ceiling 1:Fiat or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade wafts: ❑Waft 1:Wood Frame,16in.o.c.,R-19.0 cavity insulation Comments: Windows: ❑Window 1:Wood Frame,Double Pane,U-fmc .0.000 For windows without labeled U-fadors,describe feahuea: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,1.146ctor.0.000 Comments: Floors: ❑ Floor 1:Heated Slab-On-Grade,R-0(uninsulated) Comments: Pleating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air(Non-Electric):78 AFUE or higher Make and Model Number. Air Leakage: ❑Joints,penetratwns,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5'clearance from combustible materials.ff non-IC rated,the fixture must be installed with a 3'clearance from insulation. Vapor Retarder: ❑ Required on the warmAn-winter side of all non-vented framed ceilings,walls,and floors. Materials klernti8catkm: ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-vahues and glazing U-factors must be dearly marked on the building plans or specifications- Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5_Duds outside the building must be insulated to R-8.0. Duct Construction: ❑All duds must be sealed with mastic and fibrous backing tape.Pressure-sensitive tape may be used for fibrous ducts.Duct tape Page 2 is not permitted. [a The HVAC system must provide a means for balancing air and water systems. Temperature Controls: j Thermostats are required for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating andlor cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: Ll Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: Ll All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time dock. Heating and Cooling Piping Insulallon: ❑ HVAC piping conveying fluids above 120°F or chilled fluids below WF must be Insulated to the levels in Table 2. Page 3 i Table 1:Mbdmmn Insulation Thickness for CircuisMV Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2:Minimum insulation Thickness for HVAC Pipes Hot Water Pipes Fluid Temp. Insulation Thickness in Inches by Plpe Sizes Piping System Types Range("F) �2"Runoyts 1"and Less 1.25"to 2.0" 2.5"to 4" Head"Systems Low Pressurefrenperature 201-250 1.0 1.5 1.6 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooking Systems Chilied Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Page 4