Loading...
PLANS DocuSign Envelope ID 556M08B-2AEC4A81-915E-514280043258 Att4641 Prepared by: Prepared for • Dave Lacroix Mare Hannan liosemmeill acroix(aadirondacxbasement.corn mhannan1955 - C�gmaii.com Adirondack Basement Systems P (718)344-6108 www.ad,rondackbasement.coxn Job location: TF 900 752 5807 19 Woodshire Ct 0 518-371-9621 Queens bur ,NY 12804-9405 F 518.371-5a88 Prepared on: FILE COPY 6-5-20 Product List Egress Window Weal,Premy r Large .. .... 1 Egress Cover.Premier Large .. foundation Cutting,Poured 1 Egress Window Excavation,Ahni- Tie into Exterior Drainage I Egress Windom.Large 1 excavator au cis Special order Pella Slider , ......, 1 Project Sum nary Add Means of Egress ... $7,Sa2.00 Total lnve5*"ient S7,582.00 TOWN OF QUEENSBUBY1 Total Contract Price .. $7,582.00 BUILDING DE=ti.P T MENT Deposit Requ red-25% eased on our limited e ;t:''!.F�uon,comp ance 31.895.50 with our comments sh:: ^e conrtr d as Deocisit Paid indicating the plans anti et:itications re in $1.895.50 fui{ compliance with the::,6ui(oing Co s of Amount Due Upon Installation .... $5,686.50 New York State. Customer Consent Any alteration from the above sokifications and corresponding price adjustment(if necessary)will be made only at the Customer's request or approval. Completing the work in this Proposal at the time scheduled is contingent upon accidents or delays beyond our control,This Proposal is baser primarily on the Customers description of the problem,This Proposal may be withdrawn it not accepted by the Customer within 30days. Authorized Signature ✓ 1—LZL_4 ay' Date 6/5/2020 Acceptance of Contract— amrwe Ore aware of and agree to the contents of this Proposal,the attached Job Detail sheet(s),and the attached Limited Warranty.;together.the":ontract').You are authorized to do the work as specified in the Contract liwe will make the payment set forth in this Contract at the time the project is cempieteci.I/we will pay your service charge of 1-1/3%per month(16%per annum)if my/our account is 30days or more past due. plus your attorney's fees and costs o collect and enforce this Contract 1p a ) CustomerSignatu$a ,_. Date 6/5/2020 ae•IEDs.'.7"1438 Customer has received a copy of the"Repair Science"book __ Initial A full perimeter system ha been recommended (Q ' d w -r I itiai J _ LJ�] 308.7-1-14 RC-0354-2020 If JUN 2 9 7021 Hannan, Mark I TOWN OF;_.__..._a.-._,._._..�r-...._�...� r Y 19 Woodshire Ct -4` rtiNv ° r -- tf QUEENSBURY Egress Window BUILDING & CODES DEPT. Reviewed y: 'date: f 7"a Adirondack Basement Sy ems Job location Pap 115 4 Jones Rd Halt+rocr NY 1 Uo5 19 Woodshire Ct Queenshury NY 12804-9405 6-5-20 DocnSign Envelope ID 556AA088-2AEC-4A81-9156-51428DD43258 Job Details 1.1"..."Im."1".... .............. Niiii............... ..........,„„.....6 Type of Wall Poured Concrete Existing Wall Finish Plain Existing Floor Finish Concrete ..- Adirondack Basement Systems Job Location Page VS 4 Jones Rd Haltrroor NY 1t065 19 Woodshire Ct Queensbury NY 121304-9405 6-5-20 • DocuSign Envelope ID 556A4088-2 EC4A81-9156-51428DD43258 Job Details ( ontinued) Specifications Rockwell Size 3 Rock ell coy r Connect drainage from bottom of Rockwell into existing exterior drainage system.Pella Slider window Contractor Will 1.)Remove and repla.-concr-te as necessary in the workplace. Customer Will 1.1 Move items at leas 10 fee away from the work area 2.)Repair any sprinkl: lines t at may be damaged during the installation. 3.)Mark any private li es tha•may be hidden underground.and assumes all liability if damage should occur to such lines. Additional Notes 1 Customer has read an r under tands warranty Customer Initi I Pfkit Customer acknowled--s that •rey Rockwell window well and Pella window will ie spec I ordered and deposit will be non-refundable. Adirondack Basement 5 ems Job Location Page 3/5 4 Jonei Re Naltrnoon NY '•065 19 WoodshireCt Queensbury NY 12804-9405 6-5-20 DOcuSign Envelope ID 556 08B-2 EC 1-9156.51428DD43258 Limited ar anty Standard Exclusions Perm ed By a Law This f eundat ion L united W r rally)' arranty')is made in lieu at and excludes all other warranties.express or implied,and al other obligations on the part of Adirondack Basement Systems!-Contr tor-1 tot customer;"Customer-I.There are no other verbal or written warranties and no warranties that extend beyond the description on the face hereof.including NO RRANT 5 OF EXPRESS OR IMPLIED MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE General Term For the apple able t iris peel . indica below.this Warranty is transferable at no charge to future owners of the structure on which the work specified in Etas Contract is completed This Warranty i in effect i the job specified in this Contract is completed and paid in hill and,alternatively,is null and void if full payment is not received.Contractor does not warrant products •t mint• ed below,but some of such products may be covered by a manufacturers warranty.All material used is warranted to be as specified in this Contract.All work will complet in a workmanlike manner according to the standard practices of the industry Exclusions THIS WARRANTY DOES N T COVE• CO4iITRAC TOP SPECIFICALLY DISCLAIMS LIABILITY FOR AND CUSTOMER HOLDS CONTRACTOR l-IARMLtSs FROM Iterterior waterproofing;2i plumbing age.3 Customer-caused damage-4)dust from installation 5 i damage to real or personal property such as walle countertop.or floor coverings. framing sheetrock.exterior aterials. areinets appliances.and sn on.including any damage alleged to have been done by the Contractor's use of heavy equipment necessary to complete the job:6)any inju or dam .e caused by mold to property or person;71 failure or delay in per or mance or damage caused by acts of C,od!flood ire storm methane gas.etc.).arts of civil or mill authc ty.or arty cause outside Contractor's control:8S damage from a lifting operation;9)basement water seepage.and 101 damage from heave. lateral movements/forces a illsde c •.land sliding,or slumping of fill soils While Contractor assumes responsibility for utility damage that occurs as a result of Contractors installation such protcrtion.limited.••edacingirepau the area Contractor damaged and does not include any upgrades to utilities for code compliance or other reasons Items For Which Customer s R .• 'bb use�rner shall 1)make tali .ynrent t the crew leader upon completion of work:21 prepare the work area for installation:31 be responsible for any finish carpentry.oatnhng paneling.landscaping.etc. t may be essary after Contractors work is finished:41 mark private lines'Satellite.propane.sprinkler etc.!S)maintain positive drainage away from the repaired wales);6) -k gust s clean and in good working order:7)direct downspouts a sufficient distance away from the repaired wales):8)maintain proper expana-inn joints in concrete late.that e adjacent to the repaired walks):and 9)any items mentioned in this Contract under'Customer Will'or'Additional Notes. Warrant v is in effect when r-•is cone led and paid in full THIS WARRANTY DOES N COVER AND THE CONTRACTOR SPECIFICALLY DISCLAIMS LIABILITY FOR WATER DAMAGE TO FLOOR COVERINGS.FURNITURE STORED ITEMS.FINISHED ALLSA a OTHER OBJECTS INSIDE THE FOUNDATION.Contractor will not be responsible for any damages caused by mold.to include but not be limited to property da .-. ,person injury.loss of income.emotional distress death,loss of use,loss of value.and adverse health effecte or any other effects.Homeowner agrees to keep area dry and .. ill n her obligations on contractors part.There are no other warranties verbal or written Adirondack Basement Sy elm Job Location Page4/5 IonesRc etdlfrnoanNr fU65 19WoodshireCtQueensburyNY12804.9405 6•S-20 • DocuSign Envelope ID 5567,A08B-24EC-4A8'-9156-514280D43258 Notice o Right to Cancel Yoe are entering into:contr.ct.If that contract is a result of,or in connection with a salesman's direct contact with.or call to you at your residence without yo r solici ing the contract or call,then you have a legal right to void the contract or sale by notifying us within three business days from icheve of the following events occurs last: 1.The date of the tra saction which is: 6/5/2020 or 2.The date you recei -d this otice of cancellation. Adirondack Basemen Syste s extends this right of cancellation to a 14 day period from the date the contract is signed by Customer.In the event of cancellat.n.if t -permit has been obtained,permit fees shall not be refundable.If the permit fee is not a separate item in the contract.the fee i $250. •ny custom ordered items shall not be refundable;the amount retained snail be materials cost with shipping plus 1596_ It credit and was used for a transaction,any associated creo t card processing fees are non-refundable. How to Cancel If you decide to cance this tra saction,you may do so by notifying us in writing at: Adirondack Basemen Syste 4 Jones Rd Halfmoon,NY 12065 Adirondack Baseme Syste TF 800-752-5807 0 518-371-9621 F 518.371-5888 www.adirondackbase ent-co 4 Jones Rd Halfmoon.NY 12065 You may use any writt n state ent that is signed and dated by you and states your intentions to cancel,or you may use this notice by dating and signing bel. .Kee.one copy of the notice because it contains important information about your rights. I wish to cancel. Owner s Signature Date Owner's Signature Date The undersigned ackn.wledBes receipt of the two copies of the Notice of Right to Cancel. DocuSigreo by '. 6/5/2020 \—amosiefidissmee Data °enter's Signature Date Adirondack Basement Job Location Page VS 4 Jones Rd Haitmoon NY 2065 19 Woodshire Ct Queensbury NY 12804-9405 6-5-20 E GRES • MEASUREMENT SHEET 4� r �"°� 4R c�b WINDOW SITE 8-E-3 5= HEIGHT WIDTH SLIDER IS 48'STANDARD i a INSWING IS 36' OR 48' MAX CUSTOM Ff./1 S RI QUIRE APPROvat WINDOW SIIF i _ I ,` I to • * !T ' , -D: a _- A. 71 SEE CHART FOR EGRESS SIZING E IS HEEGHT WINDOW TOP NEEDS TO BE LOWERED FOR CEILING OR HEADER ETC i ;__ I i STAKWEL 54'wide I 1 modu!e- 13' max window wroth-48' C each addtl- *15` • -s SCAPEWEI 42' or 54'wide r4048-XX-40' max window width- 1.,. 4862-XX- 54' 36' &48' ROCKWELI. 66"wide size 1- 40' max window width-60' p I size2- i I � slze 3 CUSTOM WINDOWS NUED SEPARATE PRICING, ,I t csr name M f , r , ,, I, ' address date t • I _ EGRESS WORKSHEET • IDEN—IFY HERE ALL UTILITIES ENTER THE HOME AND WHERE I THEY RU UNDERGROUND + 4 ' - • MEASURE AND MARK THE DISTANCE FROM THE EGRESS TO THE i PROFER LINE r • DOES TH GRADE FALL AWAY FROM THE HOUSE WHERE THE EGRESS I GOING? ' ' • IS THERE PROPER CLEARANCE FOR THE EQUIPMENT NEEDED? ' • WHAT IS 71HE TYPE OF SOIL? ' ' - • ARE 1HER FOOTER DRAINS? • IS THE CU TOMER KEEPING THE REMAINING SOIL? t10- T•-Er _. - _ • IS THE BA EMENT CURRENTLY FINISHED? • IS THERE WATER AND ELECTRICITY AVAILABLE? ! • IS THERE LANDSCAPING OR EQUIPMENT IN THE WAY-) rJ i (_CC-1rt 1___. • I. -4--.. _. H-_. . 1 Pi P F Q- IC��Ss �.aE 3 l __._.._. I , 1 1 I A [ ' / 1 r .... [- i i Front of house csr name address date ,R. Top View Isometric View • • • • • • • • Front View Side View • 4.1....-.1.101.14 Y.OW P.. LOA•,• 01.10,4,0Alibi'*:.a., in.. UN,.Maw ,10.4401-11 .1141,0 RockWell. LIC Tit Premier Window Well rIP C 66 x 39 60 WPT-663960 nowt •it Therm St r by Pella Left-Operable Vinyl New Const cti n Egress White Exterior Sliding Window (Roug 0 ening: 48-in x 48-in; Actual: 47.5-in x 47.5-in) Actual Heig t(Inc es) 47.5 Actual Wid (Inches) 47.5 i Jamb Dept (Inches) 1.63 Series N/A Interior Col.r/Finish White Exterior Col.r/Finish White Hardware C.lor/Finish White Paintable No Color/Finish Family White Frame Mate ial Vinyl Grid Type N/A Grid Width N/A Grid Profile N/A Grid Pattern N/A Glazing Ty. Double pane Argon Gas Insulated Yes Glass Stren: Annealed Obscure GIa•. No Frame Profil: Flat Screen Inclu. -d Half Screen Type Fiberglass mesh Screen Fram: Type Roll-form Roller Type Vinyl rollers CI § 2 0 2 0 2 2 , o m c 7 a o ¢ < c E 3 n 0, o K o £ co § rn fp X) 3 XI X7 _ ■ / { i § , 7 ] I \ £ - $ ° rD -• 7- 7- n $ Cl -< $ in I n k ' 7 E 2 3 3 3 n 0 E n ® m o v 4 -I -I a a 3 E i c3 m ® » m T. ¢ k I -' r \ J E r } . $ \ ; - P. 2:1 �.2 rt. § a n , r, \ \ \ 3 o k ^ 2 I e ai a 11 . a . . . . . . . _ - c a. a a a / ■ n 2 ■ M oC 0C 0 E \ ® E � / 00 i G (0 et ] I -.el n o .4 .- o , 2 - $ 2 / f f -< K - 9 -< % ƒ / F ® 0 z k k 2 / -< % w ~ . > _ D. •n• n 3 2 $ _] _ \ K \ m rID % 7 } ) = (a O. a / $ i / E 7 eb _ i i 1 i 15 "'�y'� I • _• „Pt title 4r7- • - dlia“ • FIELOCON FROLS 'IL:E COPY FRESH AIR VENTILATION t Ax\A Ai IN 49 LEI ' 4-14. 4 _ hy+ r _- _ Fresh o o at re sh Air. Simple. Precise. Reliable. Fresh Air Ventilation . -7441 • Delivers fresh air automatically, year round. -' • Enables system to meet ASHRAE 62.2 � p= ventilation standard* • Creates uniform temperature and humidity throughout the home. • Enhances effectiveness of whole house "'' filtration and air purification. 41 ►AirCycler The Fresh Air System Your home needs to be energy efficient. Fresh Air Control It also needs fresh air. Efforts to make your home It's important to deliver fresh air more energy efficient such as replacing windows and in a way that maintains energy y doors, adding insulation, and applying sealants will efficiency. The Field Controls - - reduce natural air exchange with the outdoors. The Fresh Air System does just that, FAC result is compromised indoor air quality with increased providing tempered,fresh air using concentrations of airborne bacteria, mold,viruses and the existing air handler and duct system. The AirCycler® other allergens. Fresh Air Control operates the HVAC system blower to deliver fresh air throughout the entire home. The To address indoor air quality,fresh air FAC is set by the contractor and works independently ventilation is recommended by HVAC engineers and is of the thermostat, providing better control and more prescribed in ASHRAE standard 62.2. In many states, consistent operation. fresh air ventilation is required to meet building codes for new construction or to obtain energy tax credits in existing homes. The FAS Fresh Air System from Field Fresh Air Damper Controls meets these requirements by delivering fresh air Our Fresh Air Damper remains i automatically and efficiently.The FAS includes proven closed until instructed to open components for simple, reliable,fresh air delivery for by the Fresh Air Control. It then improved indoor air quality. opens to allow fresh air to be FAD pulled into the return plenum where it is mixed with conditioned air, filtered, and distributed to the rest of the house. 'The American Society of Heating,Refrigerating,and Air-Conditioning Engineers(ASHRAE)has determined how much fresh air is needed to provide an acceptable F I E L D C ( level of indoor air quality,specified in ASHRAE Standard 62.2,which states that we need to provide 7.5 cfm of fresh air per bedroom,plus the ability to get an additional 0.01 dm of fresh air per square foot of floor area. .,-,,,,,I, • }tip t • C• 5".j4. P, How it Works The AirCycler Fresh Air Control monitors the central system fan operates and uses the normal operating HVAC system and activates the Fresh Air Damper and the cycles to supply fresh air without added energy use. central system fan when fresh air is needed in the home. During periods when the central system is not operating, The FAS ensures better temperature and humidity control the AirCycler activates the system fan, providing effective, by enhancing air circulation during and between heating/ efficient fresh air ventilation all year round. cooling cycles.The AirCycler knows when the central FRESH AIR DAMPER (FAD) Allows fresh air flow when activated by FAC FRESH, CLEAN, PURE AIR To all rooms RETURN UV Aire® p !vr from all rooms Air Purifier f�'�, `�.. . �� ( Zaps airborne �j i \�_ germs,bacteria& it l UV Aire® mold,l cl keeps i � t_ Ultraviolet m coil clean �`� � i Treatment �►h F0 Zone jJ _ _ �b l; AC coil Furnace AC ! a ;!1 J Duct �' __ , Iv% --ill I A I: i4 4.°14 k*IT' *kk14*f k, — — - —..,_._._— "1-jiL" i`` _ FRESH AIR • ..., Media Air Cleaner'" ` �, � `` Traps pollen,dust,and dander CONTROL (FAC) 4 ri }� Improves circulation ' liY-1. and fresh air flow n. PAPFor a whole house solution that cleans and purifies the air, ask about the Field Media Air Cleaner and the UV-Aire®Air Purifier.Ask for the Indoor Air Quality Guide (form #4283) wherever Field products are sold. ) NTROLS Fresh Air Ventilation Specifications The Field Controls Fresh Air System (FAS-1) " 20- V - �r`irJ`- combines the AirCycler® Fresh Air Control (_. _, (FAC)with the 6" Fresh Air Damper(FAD-6). 4r� ) 1 4414 AirCyder Fresh Air System Model Product Features Voltage Amps Hz Watts Part No. Fan ON and OFF delay settings Fresh Air Control Vent ON and OFF delay settings 24 0.07 — — 1-199 minutes in 1 minute increments, plus an FAS-1 unlimited setting for both ON and OFF. 46590600 Fresh Air Damper Stainless steel construction, providing superior 24 — 60 3 Fits 6"duct or pipe size corrosion resistance. Power open/close in 15 sec. Notes:The AirCycler ON/OFF function enables or disables the fan recycling function,but all thermostat control signals operate regardless of the switch position.All outputs protected by a 3A self-resetting fuse,impossible to damage with wiring errors. Fresh Air Products Model Product Description Voltage Amps Hz Watts Part No. -a- FAC Fresh Air Control AirCycler 24 0.07 — — 46590400 4 FAD-4 Fresh Air Damper Fits 4"duct or pipe size 24 — 60 3 46590504 FAD-6 Fresh Air Damper Fits 6"duct or pipe size 24 — 60 3 46590506 :'. FAD-8 Fresh Air Damper Fits 8"duct or pipe size 24 — 60 3 46590508 FAD-10 Fresh Air Damper Fits 10"duct or pipe size 24 — 60 3 46590510 AFI-6 Air Flow Indicator 6",indicates cfm — — — — 46590900 SEC SmartExhaust Programmable control 120 — — — 46591000 '\. . for exhaust fans 4G1110 FIELDCO NTROLS fieldcontrols.com Field Controls,LLC 2630 Airport Road Kinston,NC 28504 TEL:252.522.3031 FAX:252.522.0214 02010 Field Controls Form#4331 Printed in U.S.A.(RS10) SUPPLY • 'N.' 4. c=i Q —� N '...I a 0 /••� LV J W N N N N N N N N Na N ,p CC. V O, lr N O) C. W W W Q O = U, W N O ,O O V T Vl W N O �O m V O. t.n - C. N -� O r m T O A O O O O O O O O . . .=, . . . . 4. . . . O O O O O O O O O O O O /�1 0 .- .- O y D O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Z `1■ f f -, W Os N) f"1 ,w EI T N r. O V, N U+ A A A A A A A A A A W CO CO Co W CO CO CO Co W N N N N N N N N N N = �• C 0 ,O N V O, Cn A CO N 0 ,O CO V O, CA A W N O ,O CO V O, U, A W Di m —. ° D 0 _ =c.n 0 T Ci a = O 11 W U, O ,� c•`� O 2 Cn (n Cr, Cr, Cn (n Cr, Cn (n A A A A A A A A A A W CO CO CO W CO Co W W CO N N 7� H M _ O CO V O, CA A Co N O ,O CO V O, Cr, A Co N O ,O Co V O, Cn A CO N O ,O CoN Z D C /1 Ili T 0 B O` _ —I lig I. A V C7 CD D c !V = O v CD3 3 IV ciZ 3 N U . O, P P U CA Cn w Cn N CA Cn Cr, (n N A A A A A A A A A A co co co co co .��, v �+ �^ CI, A CO N 0 ,O CO V O, Cr, A W N — 0 ,O CO V P Cr. A CON 0 ,O CO V O, Cl, .... W IV O o A ,O O, CJ Cn 0I 07co C C0 C _ o O Y CD 0 a �. o _ Cn — N W o. -0 O N V V V V O• O, O- O, O- P O, O- O, O, Cn CA Cr CA CA CA U, CA Cn CA A A A A A A A c C 7� o N C O CO = �• �• O CO N O ,O CO V O, CA A W N O ,O CO V O• CA A W N — O ,O CO V O, Cr, A W •A C C Z.O m > 13 _v o o_ 3 r O, N A V O co n CD a T N N N W A a T O O V V V V V V V V V V O• O, O. O, CT Cr O. O, O, O, Cr, CA Cn CT, N Cn (n CA Cr, Cr, tr, n O ,O CID V O. Cn A W N — O ,O CO V CACn A Co Ai --. O 0O CO V O, U., A co AO O In V A CT O co ry 'CD O = 0_ CO H O CO CO CO CO CO CO CO Co CO V V V V V V V V V V O, O, O, 0, O, O, O, 0, P CT U, Cn T O CO V O, U., A Co N O ,O N V OsCr, A W N O ,O CO V O, CA A Li N O ,O OD ,O CO N C...) 0 N .. r. O 7 CD 0 `Q cr +. W W W W W W N N N N N N N IV J N .V Large Pipe Size l.n - ON O -O OD V O, In . W N O ,O CO V T CA a W N —. O .O m V O, Ln a 3- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 = 0 0 0 0 0 0 0 0 0 0 0 IX C. a m 0 0 0 0 0 0 0 o O 0 0 0 0 0 0 0 0 o O o O 0 0 0 0 0 0 0 0 0 0 T N o `O m V O, t.n A W C 7 = coo N v C N � O O O ,O ,O ,O ,O CO CO CO V V V O, O, CAO, Cn Cn Cr, A A A Co W W LiD - . . 7 O V A co0., N ,O O, W O V A — Co CA N ,O O, COO V N A � CO Cr,C ,O O, COO N CO CO V V O, Cr, A N CD L. T CO = = COD N a O —' a m N N N N N O O O so ,O co co CO CO V V V O, O, O, CA Cn Cr, CA A A A W co CO V (n A N O - O p CO Cn N ,O O, W O V A W CA N ,O O, C. 0 V A CO U, N ,O O, CO0 V A � CON Z N C C - O 0 O a IV O coC 0 V O, A N 0 = c CD a- W co N N N N O O O sO '0 -0 -0 CO CO CO V V V O, O, O, O, Cn CA Cr, A A 2., _ O 0^ O C. W O V A CO Cr, N b O, CO0 V A. co01 �'''� (0 - C a Cr,Cn N ,O P coW O V A CO Cn N00 W 0 N ,C, m a N CD CO CT cn w -- O o_ N 0 0 0 0 �co" C A A CO CO Li N N N � ,O ,O ,O CD W CO V V V O. O, O, Cn U., Cn .A O` O co V A — coCn N .O 0.. co O O O CO U., N ,O O, W 0 V A CO N AO ,O O, Co 1� CD n '0 fa N 0 V CDA 3 _� n N O 0 T H `<01 CD Cn A A A Co CO CO N N N N 0 0 0 ,O ,O CO ,O '4 CO Cb V V V O. O, P O C .Z -43 N W A N O cm 1 �• O V A CO Cn N ,O O, W 0 V A co Cn N ,O a W 0 V A CO (n N •O O, CO O U1 G. ` d i CD N �. c O• N O so CD 3 Cn (n Cn A A A A Co Co CO N N N O O O 0 sO sO CO CO CO CO V N ,O O, CO O V A V W �` W = T CT- CJ, N ..0 O, co V A coU, N ,O O, W O -J A —_ CO 0.) l A O O• o CO ' .--. ' Fresh Air Dampe SIZING & SELECTION Example of Fresh Air Damper Sizing using the Design Method: Step 1: 1500 sq. ft. home, 3 bedrooms, ASHRAE62.2-2010 standard. From Table 1, continuous ventilation required is 45 CFM. For damper sizing multiply continuous ventilation value by 3 equates to 135 CFM for fresh air damper size. Step 2:Static pressure in the return is 0.15 inches WC (measured) Step 3: Ductwork system design consists of: • From Table 3, two 6" diameter 45° Elbow (10 equivalent feet) • 10 feet of straight 6"smooth diameter ductwork (10 equivalent feet), • The system has 20 equivalent feet of smooth duct (10 feet + 10 feet = 20 feet) Step 4: From Table 5, the 6" Fresh Air Damper delivers 136 CFM in flex duct at 30 equivalent feet and would be the appropriate damper for this system. Table 5: Damper Air Flow based on Pressure Measurement (in (FM) Return Air Static Pressure("WC) 0.05* 0.1* 0.15 0.2 Damper&Intake Equivalent Feet of Duct Flex Smooth Flex Smooth Flex Smooth Flex Smooth Hood Length 10 40 32 57 45 70 56 80 64 4"FAD Damper 30 33 26 47 37 57 46 66 53 50 29 23 41 33 50 40 58 46 10 67 54 95 73 117 94 135 108 5"FAD Damper 30 56 45 80 64 97 78 113 90 50 49 39 70 56 85 68 99 79 10 90 72 128 102 157 126 181 145 6'FAD Damper 30 79 63 111 89 136 109 157 126 ' 50 71 57 100 80 122 98 141 113 10 154 123 218 174 266 213 308 246 7"FAD Damper 30 129 103 183 146 224 179 258 207 50 113 91 160 128 196 157 227 181 10 174 139 246 197 301 241 348 278 8"FAD Damper 30 154 123 218 174 267 214 308 246 50 140 112 197 158 242 194 279 223 10 262 210 371 297 454 363 525 420 10"FAD Damper 30 239 191 338 270 414 331 478 382 50 221 177 312 250 383 306 442 354 *.05 are new modulating appliance parameters. 0.1 are the traditional appliances. Once the design gets out of range, additional electrical consumption begins to take place. Technical Service: 800.742.8368 • fieldcontrols.com 13