Loading...
ResCheck Generated by REScheck-Web Software w w CD w Compliance Certificate a al in BE C E 0 \LIE "--` r.z.. cro, . Project Garage Remodel SUN 25 QO x a 0 i fa RP Energy Code: 2018 IECC --• Location: Warren County, New York TOWN OF QUEENSBURY 5 BUILDING&CODES Construction Type: Single-family n Project Type: Alteration 0 Climate Zone: 6 (8499 HDD) W Permit Date: N N Permit Number: N N O Construction Site: Owner/Agent: Designer/Contractor: �. NC 320 Ridge Road Queensbury, NY 12804 ompliance: Passes using prescriptive requirements for alteration projects Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling: Cathedral Ceiling (no attic) 400 42.0 0.0 0.025 10 Wall: Wood Frame, 16" o.c. 243 40.0 0.0 0.043 10 Window 2: Vinyl Frame 4 0.200 1 Window 1: Vinyl Frame 11 0.200 2 Wall 1: Wood Frame, 16" o.c. 147 40.0 0.0 0.043 6 Door: Solid Door(under 50% glazing) 18 0.100 2 Wall 2: Wood Frame, 16" o.c. 147 40.0 0.0 0.043 6 Wall 3: Wood Frame, 16" o.c. 264 40.0 0.0 0.043 11 Floor: All-Wood joist/Truss 264 30.0 0.0 0.033 9 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in RESc`hey Version : REScheck-Web and to comply with the mandatory re firemen ' ted in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 1 of 9 REScheck Software VersionChecklist: REScheck-Web Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal [Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. [Not Observable Systems serving multiple ENot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ['Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 2 of 9 Section Foundation Inspection Complies? Comments/Assumptions & Re..ID _ 303.2.1 A protective covering is installed to EComplies [FO11]z protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below [Not Observable grade. ElNot Applicable 403.9 Snow-and ice-melting system controls ❑Complies [FO12]2 installed. Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- EComplies See the Envelope Assemblies 402.3.4 EDoes Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- EComplies See the Envelope Assemblies 402.3.1, average). EDoes Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ENot Applicable t 303.1.3 U-factors of fenestration products EComplies [FR4]1 are determined in accordance EDoes Not with the NFRC test procedure or taken from the default table. [Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier EComplies [FR23]1 installed per manufacturer's EDoes Not instructions. ['Not Observable ENot Applicable 402.4.3 Fenestration that is not site built EComplies [FR2O]1 is listed and labeled as meeting EDoes Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ['Not Observable 400 that do not exceed code ENot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures EComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ['Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics EComplies [FR12P insulated >= R-8 where duct is EDoes Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and [Not Observable return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter EComplies [FR13]1 boxes are sealed with EDoes Not joints/seams compliant with International Mechanical Code or ['Not Observable International Residential Code, as ENot Applicable applicable. 403.3.5 Building cavities are not used as EComplies [FR15]3 ducts or plenums. EDoes Not ENot Observable ENot Applicable 403.4 HVAC piping conveying fluids R- R- EComplies [FR17]2 above 105 °F or chilled fluids EDoes Not below 55°F are insulated to 3 ❑Not Observable ENot Applicable 403.4.1 Protection of insulation on HVAC EComplies [FR24]1 piping. EDoes Not ❑Not Observable ENot Applicable 403.5.3 Hot water pipes are insulated to R- R- EComplies [FR18]2 >_R 3. EDoes Not ENot Observable ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 4 of 9 Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air Does Not intakes and exhausts. ['Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) j Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 5 of 9 Section Plans Verified Field Verified • # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel [Not Observable q ❑Not Applicable 303.2, Floor insulation installed per ElComplies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor [Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least l of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior, the exterior insulation ❑ Mass III Mass ❑Not Observable requirement applies (FR10). ❑ Steel El Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 6 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, Wood ❑ Wood ❑Does Not table for values. 402.2.2, Steel ❑ Steel [Not Observable 402.2.6 [Fill' ENot Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]' Blown insulation marked every 300 ft'. ['Not Observable ENot Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ENot Observable ENot Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]' insulation .?:R-value of the ❑Does Not adjacent assembly. ['Not Observable ENot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]' ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ENot Observable ENot Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies [F127]' determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ENot Observable tests, verification may need to ENot Applicable occur during Framing Inspection. 403.3.2.1 Air handler leakage designated ❑Complies [F124]' by manufacturer at <=2%of ❑Does Not design air flow. ['Not Observable ENot Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed for control of primary ElDoes Not heating and cooling systems and initially set by manufacturer to ENot Observable code specifications. ENot Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110J2 on heat pumps. ❑Does Not ENot Observable ENot Applicable 403.5.1 Circulating service hot water ❑Complies [F111]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ENot Applicable Ill High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system EComplies [FI25]2 fans not part of tested and listed EDoes Not HVAC equipment meet efficacy and air flow limits per Table ENot Observable R403.6.1. ENot Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating EDoes Not systems have outdoor setback control to lower boiler water ENot Observable temperature based on outdoor ENot Applicable temperature. 403.5.1.1 Heated water circulation systems EComplies [F128]2 have a circulation pump.The EDoes Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ENot Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ENot Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water EComplies [FI30]2 systems have controls that EDoes Not manage operation of the pump and limit the temperature of the ENot Observable water entering the cold water ENot Applicable piping to <= 1049F. 403.5.4 Drain water heat recovery units EComplies [F131]2 tested in accordance with CSA EDoes Not B55.1. Potable water-side pressure loss of drain water heat [Not Observable recovery units < 3 psi for ENot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90% or more of permanent ❑Complies [F16]1 fixtures have high efficacy lamps. EDoes Not ENot Observable ENot Applicable 404.1.1 Fuel gas lighting systems have EComplies [F123]3 no continuous pilot light. EDoes Not ❑Not Observable ENot Applicable 401.3 Compliance certificate posted. EComplies [F17]2 EDoes Not ENot Observable ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) 1 Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 8 of 9 Section Plans Verified Field Verified • *# Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: Garage Remodel Report date: 06/18/20 Data filename: Page 9 of 9 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 40.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 42.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.20 Door 0.10 Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments