Loading...
Manual J (" F Load Short Form - Job: 1434BaYRood t n�'w Entire House JUN i{ : : Date: Jute 26th,2020 Web REPS ! �\ J U N 2 2O� 1 I: By: Craig C Brooks WebREPS LLC. „i Plan: 1434 Bay Road 1-800-810-3280 i ---�"�""�.: ^1N.! OF Ci Et;wx.:`,;. 112, 8r.CO LIES 1880 82nd/venue Suttee 203,vero Bead,,FL 32966 Phone:800 810-3280 Fax 888 971-2999 enea:liaintJa repn�ca,eom tiesnse:CAC054709 Project Informatio For. Chris J Patten,Patten Property Development 265.-1-73.12 RC-0353-2020 7 Jackson Road,South Glens Falls,NY 12803 Entwistle, Eli Phone:518 796-4654 Fax 518 798-3069 1434 BayRd Email:patten84 BLigmail.com SFD w/gas FP 1625 s.f., Gar. 624 s.f. Design Informatio Htg Cig Infiltration Outside db(°F) -4 85 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 74 10 Fireplaces 1 (right) Daily range - M Inside humidity(%) 50 50 Moisture difference(grub) 52 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN MANUFACTURING CO.,LP. Trade GOODMAN Model GMVM970804CNA Cond GSX130301L AHRI ref 7424266 Coil CAPFA3022D6A++EEP AHRI ref 202379658 Efficiency 98AFUE Efficiency 11.0 EER,13 SEER Heating input 80000 Btuh Sensible cooling 21714 Btuh Heating output 78000 Btuh Latent cooling 6486 Btuh Temperature rise 76 °F Total cooling 28200 Btuh Actual airflow 940 an Actual airflow 940 dm Airflow factor 0.031 cfm/Btuh Airflow factor 0.051 cflnu3tuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF ( ) (Mull) (Btuh) (dm) (cfm) DINING AREA 75 4610 2755 145 140 LIVING ROOM 367 6154 3453 193 176 KITCHEN 270 1655 3590 52 183 M CLOS 16 0 0 0 0 MASTER BEDROOM 210 4497 1719 141 88 BATH 78 771 133 24 7 BEDROOM 138 4030 1398 126 71 STUDY 125 2091 2185 66 111 BR CL1 10 0 0 0 0 BRCL2 11 0 0 0 0 STAIR 44 0 0 0 0 CL 8 0 0 0 0 LAUNDRY CL 12 0 0 0 0 STUDY CL 13 0 0 0 ' 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pk wrightisoft°" 2020Jun 26 08:4225 .,., RightSuite®Universal201919.0.20 RSU16998 ___... Page 1 .. ...C`Patten Property Developrnent11434 Bay Road.rup Calc=MJ8 Front Door faces:S MUDROOM LAUNDRY 96 299 667 9 34 STAIR. 43 0 0 0 0 MASTER BATH 108 1228 562 38 29 FAMILY ROOM 456 4646 1984 146 101 Entire House 2081 29981 18448 940 940 Other equip loads 15139 2629 Equip.@ 1.00 RSM 21077 Latent cooling 6401 TOTALS 2081 45121 27478 940 940 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W rightSO'ft' 2020Jun-26 08:4225 .. - „,.„,...:._,,,,,,,„,„,.,„., RightSuite®Universal 201919.020 RSU16996 ...C`Patten Pro Page 2 perry Developmenfl1434 Bay Road.rup Calc=NU8 Front Door faces:S `i Project Summary Job: 1434 Bay Road Date: June 26th,2020 Web REPS Entire House By: Craig C Brooks 1-800-810-3280 WebREPS LLC. Plan: 1434 Bay Road 1880 82nd Aenue Suite*203,vbro Beads,FL 32968 Phone:800 810-3280 Fax:888 971-2999 Erroll:manualb@webrepsusa.com License:CAC054709 Pro'ect Information For: Chris J Patten,Patten Property Development 7 Jackson Road,South Glens Falls,NY 12803 Phone:518 796-4654 Fax 518 798-3069 Email:patten84Lgmail.com Notes: 1434 Bay Road, Queensbury,NY Desi•n Information Weather: Glens Falls AP,NY,US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 74 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 28455 Btuh Structure 18049 Btuh Duds 1526 Btuh Ducts 398 Btuh Central vent(85 cfm) 6783 Btuh Central vent(85 dm) 923 Btuh Outside air Outside air Humidification 8357 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 45121 Btuh Use manufaduler's data y Rate/swing multiplier 1.00 infiltration Equipment sensible load 21077 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 4158 Btuh Ducts 730 Btuh Central vent(85 elm) 1512 Btuh Heating Cooling Outside air Area(tt2) 208T 2081 Equipment latent load 6401 Btuh Volume(ft3) 15078 15078 Air changes/hour 0.41 0.08 Equipment Total Load(Sen+Lat) 27478 Btuh Equiv.AVF(cfm) 103 20 Req.tote(capacity at 0.77 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mt,. Make Goodman Mfg. Trade GOODMAN MANUFACTURING CO.,LP. Trade GOODMAN Model GMVM970804CNA Cond GSX130301 L AHRI ref 7424266 Coil CAPFA3022D6A++EEP AHRI ref 202379658 Efficiency 98AFUE Efficiency 11.0 EER,13 SEER Heating input 80000 Btuh Sensible cooling 21714 Btuh Heating output 78000 Btuh Latent cooling 6486 Btuh Temperature rise 76 °F Total cooling 28200 Btuh Actual airflow 940 cfm Actual airflow 940 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.77 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wr lisp htsoft." 2020-Jun•2608:42:25 .. ..„,,...r,,m. Right-Sulte®Universa1201919.020 RSU18998 Page 1 ...CPatten Property Develapment11434 Bay Road.nip Cale=MJ8 Front Door faces:S • 4.,7- 1st Floor DINING AREA rA ,:fro 1 I! 11 I GLOS j i MASTE.R3EDRCCM KITCHEN Z18',dn XI 193 c r 141dm LIVING ROOM i CL 1 STAIR 1 ig MASTER BAT;-i 34 t Tt MUDROOM LAU^CRY NDRY CL BATH ' i i ,i j 1 i._ SIlJDY �� 24 — Ir r STAIR S LIDY CL1:21 111 der i i BR 0_1 BRCL2 GARAGE Job#: 1434 Bay Road WebREPS LLC. Scale:1 :98 Performed by Craig C Brooks for: Pagel Chris J Patten 1880 82nd Avenue Suite#203 Riga It UPI 2019 7 Jackson Road Vero Beach,FL 32966 19.020 RSU16998 South Glens Falls,NY 12803 Phone:800 810-3280 Fax 888 971 2999 � ����� Phone:518 796-4654 Fax 518 798-3069 1Y�1 �YR �p patten84©gmaii.com manualewebrepsusa.com Basement UTILITY STORAGE FAMILY ROOM 10 940 dm ® 146 cfm ROOT CELLAR STORAGE Jab#: 1434 Bay Road WebREPS LL.C. Scale:1 :98 Performed by Craig C Brooks for: Page 2 Chits J Patten 1880 82nd Avenue Suite#203 Right-s"IteZ UfliwrseI 2019 7 Jackson Road Vero Beach,FL 32988 19.020RSU16998 South Glens Falls,f 1V 12803 2020-Jun-2808:42:42 etie Phone:518 796-4654 Fax 518 796-3069 Phone:800 810-3280 Fax 888 971-2999 tyDlopma>h1434 Say Roadrup patten84©gmail.com Manua©webrepsusa.com l F/A V Fresh Air Ventilation s st.___ ,..., . em ...... . .._ ,..... - cn NmN N \ y e 0) `< Wa 10 \ I 27 5 Y ' tn E DrEAlr ipn V! C) w N. . ,__ ,,,,„,., , . t . 4:1 NJ TOWN car i.—.. ry y BUILDi "'G& CODES Fresh Air Damper(FAD) Dam er and Control Combo The FAV is an intelligent, automatic, year-round ventilation system that integrates with an existing HVAC system and thermostat to meet ASHRAE 62.2 requirements. Features Benefits • Fresh Air Ventilation Control utilizes the central fan to supply • Delivers fresh air automatically,year round outdoor air from a known source through a controlled duct • Creates uniform temperature and humidity in home • Fresh Air Damper prevents infiltration during off periods • Reduces heating and cooling costs • Enhances effectiveness of media air cleaner and UV air purifiers Exclusive Fresh Air Ventilation Control Features The FAVC can monitor up to 4 appliances and apply credit from those fans.The FAVC can monitor a variety of fan types and CFM Appliance Ventilation Credit ran es,from bathroom fans andpERV/HRVs(20-225 CFM and clothes dryer and standard kitchen range hoods(80-400 CFM), to fireplace and commercial range hoods(100-1600 CFM. Indoor Temperature/Humidity The FAVC has built-in Indoor Temperature/Humidity sensor to continuously sense actual return air duct conditions.The FAVC can be Monitoring installed directly to the return air plenum of the HVAC system,or it can also be installed on the wall in air closet application. Plenum Protection& The FAVC continuously monitors indoor Relative Humidity in the return plenum to regulate humidity in the winter months and to Winter Dehumidification prevent humid conditions in the summer months by reducing the ventilation during periods of high dew points.The FAVC`also monitors outdoor air temperature.The FAVC inhibits condensation,reducing mold and corrosion of the heat exchanger. With a 30 minute cycle period,the FAVC introduces fresh air more frequently and regularly,which means the air is more evenly 30 Minute Cycle Period balanced and HVAC system does not have to work hard to catch up with a wide range of temperatures that con occur over a 60 minute time period. LExclusive Fresh Air Damper Features Neoprene Seal The damper uses a quiet neoprene no-leak seal so unwanted air and humidity are controlled.The seal is tested 500,000+cycles and meets flammability fMVSPS-302 requirements. The power open/power close damper means the motor uses very little power unlike competitive dampers that use a spring close/ Power Open, Power Close power open motor which stay fully powered during the open cycle an waste energy.Most reliable damper on the market rated over 100,000 cycles. '' l" ' - How It Works Outdoor Temperature Light The fresh Air System (FAV) is a 3 color ODT light indicates whether outside air temperature meets motor driven damper activated CFM Continuous dial ventilation requirements or if ventilation will be limited due to temperature or humiditylevels. by the Fresh Air Ventilation The CFM Continuous dial controls the continuous P ventilation rate based on size of the home and number of Control (FAVC). When there is bedrooms ond is pre-set at 100CFM. a call for fresh air, the control opens the damper allowing fresh air to enter the HVAC return. When the control is satisfied, the CFM Cool/Heat Vent _ 0 `' �� i damper is closed. dial ;'. qt , I The CFM Cool Vent dial and r . CFM Heat Vent dial ore both 1. .1,1 'm ! preset at 400 CFM each and �1t i i1� �jO-�¢ r r can be used to set the air Row ��` � I rate through a Fresh Air Damper r a(001 t,a „7"41.19.14M u hhlake�r I ,+!Ws ' t ' or HRV/ERV unit when central *�' A -- OS t$ r r i• fan is running in cooling mode I b, .;"9r.1 ..:d N.:. ar - and heating mode. 11 l! _,a a a ions,,,N t Fresh Air ,0. ,. �1` Veal .,.t . .-• Healthy Horne System' r al" sComol �.., - Optional Appliance Montoring Controls Appliance Appliance Dial Appliance Type CFM S'andard Con`ig.ra'ic Op`ional Contigcra'ion Energy Saving Mode Offers balanced ventilation by monitoring Con drive appliance#1 fan in lieu of central fan Bathroom fon, the appliance and takes credit for ventilation . Takes credit for ventilation with damper when heating or cooling #1 25-225 PP Drives appliance#1 fanwhen additional ventilation is requires within HRV ERV Unit requirement when appliance#1 fan runs, / preset at 75 CFM the heating/cooling cycle • Gets energy credit when bathroom fan is used(non ECM central fon blower) #2 Bathroom Fan 20-140 Monitors appliance#2,preset at 75 CFM Clothes Dry er, Passive Make up Air Mode #3 80-400 Opens damper when appliance#3 is on, Active Make up Air Mode Standard Range Hood preset at 200 CFM • Turns on central fan and opens damper when appliance#3 runs Fireplace, Active Make up Air Mode #4 100-160 Monitors appliance#4,preset at 850 CFM ▪ Turns on central fan and opens damper when appliance#4 runs Commercail Range Hood p p pp Specifications Model Product Description Voltage Amps Watts a. FAV-4 FAVC and FAD Motorized,stainless steel,power open/close in 15 sec.increments,Fits 4"duct 24 0.07 3 i FAV-5 FAVC and FAD Motorized,stainless steel,power open/close in 15 sec.increments,Fits 5"duct 24 0.07 3 it FAV-6 FAVC and FAD Motorized,stainless steel,power open/close in 15 sec.increments,fits 6"duct 24 0.07 3 to FAV-7 FAVC and FAD Motorized,stainless steel,power open/close in 15 sec.increments,Fits 7"duct 24 0.07 3 FAV-8 FAVC ond FAD Motorized,stainless steel,power open/close in 15 sec.increments,fits 8"duct 24 0.07 3 f r FAV-10 FAVC and FAD Motorized,stainless steel,power open/close in 15 sec.increments,Fits 10"duct 24 0.07 3 io 0 Corporate Office West Coast Office it F I i L D C O N T R O L S t w Sales/Manufactring/Engineering improving indoor Environrnenrs Distribution/Manufactring '6 o Kinston,NCCorona,CA 252.522.3031 feldcontrols.corn 951,277 0304