ResCheck rGenerated by REScheck-Web Software ‘%4 Compliance Certificate Project Entwistle - New Residence Energy Code: 2018 IECC g C 0 3 ,2O 2l� Location: Glens Falls, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,625 ft2 Glazing Area 13% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 1434 Bay Road Eli & Kristen Entwistle Ethan P. Hall Queensbury, NY 12804 1434 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave 518-744-8977 Glens Falls, NY 12801 entwisee@hotmail ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 1.5%Better Than Code Maximum UA: 326 Your UA: 321 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 1,625 49.0 0.0 0.020 33 Wall 1: Wood Frame, 16" o.c. 1,973 21.0 3.6 0.046 77 Door 1: Solid 28 0.300 8 Door 5: Solid 18 0.300 5 Door 4: Solid 18 0.300 5 Door 2: Glass 40 0.320 13 Door 3: Glass 36 0.320 12 Window 1: Wood Frame:Double Pane with Low-E 153 0.290 44 Wall 2: Wood Frame, 16" o.c. 448 21.0 3.6 0.046 16 Door 6: Glass 40 0.320 13 Window 2: Wood Frame:Double Pane with Low-E 52 0.290 15 Floor 2: All-Wood Joist/Truss:Over Outside Air 72 30.0 0.0 0.033 2 Floor 1: Slab-On-Grade:Unheated 22 14.0 0.730 16 Insulation depth: 4.0' Basement Wall 1: Solid Concrete or Masonry 1,186 19.0 0.0 0.052 62 Wall height: 8.9' Depth below grade: 6.0' Insulation depth: 8.5' Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory r ireme li t t REScheck Inspection Checklist. fl.tpa 1? ON-— 42.6 1 44- Zo Jut 2ozo Name-Title Signat e Date Project Title: Entwistle- New Residence Report date: 07/20/20 Data filename: Page 2 of10 • REScheck Software VersionChecklist: REScheck-Web Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review I Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and 1icomplies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate f, ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ONot Observable Systems serving multiple DNot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Eeomplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Entwistle- New Residence Report date: 07/20/20 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value I Value Complies? Comments/Assumptions di Req.ID 111 l 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. V ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [F03]1 depth/length. ❑Does Not table for values. v. ['Not Observable ❑Not Applicable 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value. Where interior R- R- ❑Does Not table for values. b insulation is used, verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not 4. manufacturer's instructions. ❑Not Observable ElNot Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06I1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not V ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 1 3 1Low Impact(Tier 3) Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 4 of10 Section Plans Verified Field Verified # Framing/ Rough-In Inspections Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- EComplies See the Envelope Assemblies 402.3.1, average). EDoes Not table for values. 402.3.3, 402.5 ENot Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ENot Observable taken from the default table. ENot Applicable 402.4.1.1 Air barrier and thermal barrier EComplies [FR23]1 installed per manufacturer's ❑Does Not instructions. ENot Observable ENot Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ENot Observable or has infiltration rates per NFRC 400 that do not exceed code ENot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures EComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ENot Observable ENot Applicable 403.3.1 Supply and return ducts in attics EComplies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ENot Observable return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter EComplies [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as ❑Not Applicable applicable. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not b ['Not Observable ❑Not Applicable 1 'High Impact(Tier 1) 12 !Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 5 of10 9 P Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Rect.ID 403.3.7 Ducts declared to be within the ❑Complies [FR2813 conditioned space are either 1) ❑Does Not completely within the continuous air barrier and within the building [Not Observable thermal envelope, 2) buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm/ 100 square feet of conditioned floor area served by the duct system, or 3)the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R-value, less the R- value of the insulation on the 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]z above 105 4F or chilled fluids ❑Does Not below 55 4F are insulated to >_R- 3 ENot Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 zR-3. ElDoes Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19)2 installed on all outdoor air ❑Does Not intakes and exhausts. ['Not Observable ENot Applicable Additional Comments/Assumptions: i1JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1Low Impact (Tier 3) Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not d provided. ONot Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 0 Steel ❑ Steel :Not Observable V, ❑Not Applicable 303.2, Floor insulation installed per DComplies 402.2.7 manufacturer's instructions and ODoes Not [IN2]1 in substantial contact with the d underside of the subfloor,or floor ❑Not Observable framing cavity insulation is in DNot Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood 0 Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass 0 Mass ❑Not Observable [IN3]1 exterior,the exterior insulation d requirement applies(FR10). ❑ Steel 0 Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 j High Impact(Tier 1) 2 Medium Impact(Tier 2) j 3 [Low Impact(Tier 3) I Project Title: Entwistle- New Residence Report date: 07/20/20 Data filename: Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel :Not Observable 402.2.6 [FI1]' ONot Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]' Blown insulation marked every 300 ft2. ['Not Observable ONot Applicable 402.2.3 Vented attics with air permeable OComplies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ONot Observable ONot Applicable 402.2.4 Attic access hatch and door , R- R- ❑Complies [FI3]' insulation zR-value of the ❑Does Not adjacent assembly. ['Not Observable ONot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [F1171' ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. DNot Observable ONot Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]' determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ONot Observable pressure differential of 0.1 inch ONot Applicable w.g,across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ONot Observable tests,verification may need to ONot Applicable occur during Framing Inspection. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]' by manufacturer at<=2%of ❑Does Not design air flow. :Not Observable ONot Applicable 403.1.1 Programmable thermostats ❑Complies [FI912 installed for control of primary ODoes Not heating and cooling systems and initially set by manufacturer to ONot Observable code specifications. ONot Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ONot Applicable 403.5.1 Circulating service hot water ❑Complies [FI1112 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Entwistle- New Residence Report date: 07/20/20 Data filename: Page 8 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system EComplies [FI25]2 fans not part of tested and listed EDoes Not HVAC equipment meet efficacy and air flow limits per Table ['Not Observable R403.6.1. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26)2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. -- 403.5.1.1 Heated water circulation systems ❑Complies [FI28)2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply [Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ElComplies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Complies [FI30]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the [Not Observable water entering the cold water ❑Not Applicable piping to <= 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ['Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90%or more of permanent ❑Complies [F16]' fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable .404.1.1 Fuel gas lighting systems have Complies [FI23]3 no continuous pilot light. ❑Does Not ENot Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [F17]2 ❑Does Not ❑Not Observable ❑Not Applicable [1 High Impact(Tier 1) [ijMedium Impact(Tier 2) 3 (Low Impact(Tier 3) Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID1 303.3 Manufacturer manuals for ❑Complies [FI18)3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J Project Title: Entwistle - New Residence Report date: 07/20/20 Data filename: Page 10 of10 r2018 IECC Energy ‘%6 Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 24.60 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.29 Door 0.32 Heating & Cooling Equipment Efficiency Heating System: _ Cooling System: Water Heater: Name: Date: Comments