Loading...
BINS-002408-2019 05032019INSPECTION WORKSHEET (BINS-002408-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0023-2019 Case Module:Permit Inspection Date:Fri May 3, 2019 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Building Framing Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Granted Permission 63 Quaker, LLC Applicant 63 Quaker, LLC Primary Owner Fiacco, Michael Contractor J & P Builders Architect KPB Architecture Checklist Item Passed Comments Building Inspector Notes NO 5/2/19 Framing Not Approved - Remove carriage bolts from post to beam connections and install hex head bolts. - Install Truss Bracing as per Truss Bracing Sheets. - Remove all screws from truss hanger toe nail locations and install specified hanger nails or screws. - Verify all Existing and new trusses are anchored to the beam. - Submit 3rd party engineer's structural inspection of all canopy framing. CALL FOR RECHECK WHEN READY FOR INSPECTION! May 03, 2019 Page (1) INSPECTION WORKSHEET (BINS-002408-2019) Checklist Item Passed Comments Framing NO 5/2/19 Framing Not Approved - Remove carriage bolts from post to beam connections and install hex head bolts. - Install Truss Bracing as per Truss Bracing Sheets. - Remove all screws from truss hanger toe nail locations and install specified hanger nails or screws. - Verify all Existing and new trusses are anchored to the beam. - Submit 3rd party engineer's structural inspection of all canopy framing. CALL FOR RECHECK WHEN READY FOR INSPECTION! Jack Studs Headers NO Continuous Header for Garage Doors with Straping NO Truss Specification Provided NO Bracing Bridging NO Hurricane Clips/Uplift Screws/Nail Holes Filled NO Air Seal all Plates and Sills NO Air Seal All Registers at Floor NO Air Sealing all Joints Before Insulation NO Joist hangers NO Jack Posts Main Beams NO Exterior sheeting nailed properly NO May 03, 2019 Page (2) INSPECTION WORKSHEET (BINS-002408-2019) Checklist Item Passed Comments 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing Walls NO Metal Strapping for Notches Top Plate NO Anchor Bolts 6 ft. or less on center NO Ice and water shield 24 inches from wall NO Soffits-Insulation Baffel NO Windows Habitable Space Bedrooms NO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below grade NO 5.0 sf grade NO Design Professional Sign-off, if required NO May 03, 2019 Page (3) O'Brien, John (Inspector)