Loading...
blower door results Envelope Leakage Test Testing Company: Technician: Name: LoCascio Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury , NEW YORK 12804 Phone: 5188573144 Email: tony@locascioenergysolutions.com Building Information: Customer Information: Project ID: 98 Richmond Name: Hodorowski Homes Address:, 98 Richmond Hill Dr Address: Queensbury, NY 12804 Geo-Tag Data: Latitude: 43.304973 Longitude: -73.708123 Timestamp: 2020-08-03 15:20:01 Measured Leakage: 1,287.9 CFM50 Test ID: 98 Richmond Purpose of Test: 50 Pa Env. Leakage Measured ACH50: 2.98 Effective Leakage Area: 70.8 in2 Building Volume: 25,964.0 ft3 Enclosure Surface Area: 3,113.0 ft2 Coefficient (C): 101.3 Exponent (n): 0.650 (assumed) Test Standard: RESNET 380 One-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 68 °F Outdoor Temp: 80 °F Altitude: 404.0 ft Time Average Period: 10 seconds • Test Date and Time: 2020-08-03 15:34:22 • 2000 i • Depressurize 1888 ci800 700. . ._ rn 500 • C -s 400 m 300 . : _ 200 4 5 6 7 8 910 20 30 40 50 60 Building Pressure(Pa) 14 ^2e2° RECEBVEn AUG 0 4 2020 I Envelope Leakage Test Test Readings: Target(Pa) Bldg(Pa) Adj Bldg_(Pa) Fan (Pa) Flow (cfm) Config Baseline 1.2 -50.0 -48.6 -49.8 -48.1 1,256.8 Ring A Test Equipment: Flow Device: Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge: DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: • None Comments: None Report by TEC Auto Test 1.7.2 (87), ©2020 The Energy Conservatory, Inc. Page 2 of 2