Loading...
2005-150 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050150 Date Issued: Friday, September 23, 2005 This is to certify that work requested to be done as shown by Permit Number P20050150 has been completed. Tax Map Number: 523400-315-006-0001-014-000-0000 Location: 17 FOUNDERS Way Owner: KENNETH & LAURA COLLETTE Applicant: KENNETH &LAURA COLLETTE This structure may be occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the / property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enfo etnent Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 (21W Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050150 Application Number: A20050150 Tax Map No: 523400-315-006-0001-014-000-0000 Yermission is hereby granted to: KF,NNETH& T,ATIRA COLLETTE For property located at: FOUNDERS Way in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with die NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: KENNETH&LAURA COLLETTE Fireplace 36 FRONT St Garage-2 Cars Attached LAKE GEORGE, NY 12845 Single Family Dwelling $265,000.00 Total Value $265,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency COLLETTE CONSTRUCTION 9 COLLETTE LANE HITDSON FALLS_ NEW YORK Plans&Specifications 2005-150 Lot 157, House No. 17 Founders Way Bedford Close, Section 6 2325 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE $346.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, April 05, 2006 (if it longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the 7W119VbT sd , April 05, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement GS- so C A—Residential Plan Review: One & Two Family Dwellings Y I / /A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor r' Residential Check Paperwork Compliance and Inspectors Checklist: OK JDampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width, 36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: n Office Use Location of installation: File Permit No. Tax Map No. tL M Fee Paid Owner's Name: e ,�n; e Address: _ / ;, �. . 2. INSTALLER'S NAME 'P COR ` PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gallbdrm = 1980— 1991 x 130 gal/bdrm = 9 —prey 3 / x 110 gal/bdrm = 33� Garbage Grinder Installed yes ✓ / no Spa or Hot Tub Installed yes i / no i, 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) St-� `►V1st o)") To-ooizraDby Soil Nature Ground Water Bedrock or impervious Material Domestic Water Su 1 la sa at what depth at what depth municipal Rolling loam feet feet well Steep slope clay if well;water supply ,%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: Q-5'C'>' gallon(min. size 1,000 gal.) Tile Field: each trench ft. Total System Length: ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: ! Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signature of responsible person b ate t i 5r•.wt:r;t :uitl St;wsiP.t= I>i:�j�n�al tatssjstt`e' Appinidi x t A11-SO i.1''• ION I�'J I;I,I.) SEP/1ItM ION It1,311.31 H ICI P1t TS' n �� POND. 1^t�LL, tµ »�rrt•h• .. ' •� 147 j c•oar�. � ./� • sct•t1c. c � �� c u,��n�rul�n�•ri ' 6`tR.t.�i �+T •�� ►�{�p�+ y� �1 • '•• �j�'.,���}�{ �,T /gyp Q{�� :. i. .•i;;s 7, SlrT A URE (L Xl`IL'QitLY ATIO.4'?1/i"�.USrVN;$lOV'�'o rz0h,SVL'1 V1►Olia�awvJ Permit No. �S' Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid `f 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subiect to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder (_.0 //etfvr �v �i Owner: �/,1,ae Address: 1 :7 a,,AX p A< V�i A. Address: rZr a X Home Phone: p a/4 Home Phone: Email Address: Email Address: Cell Phone: 3 6S' Cell Phone: �j" FAX Phone: 46'k 'i<- FAX Phone: 11 Person responsible for supervision of work with respect to building and codes compliance: / Name: /et-n) C .a//e Address: _'74i-97c Phone Location of proposed construction: Lot N {Legal^l A,ddress: Tax Map Number: �'�(�a'�-/ Subdivision Name: Estimated Cost of Construction: $ d-C crc ' Proposed construction is for: ZResidential Use _Commercial Use Name of Business: - If proposed construction is an addition, what will use of new addition be? New Addition Alteration Proposed Construction V Floor 2^d floor Other Total Proposed structure (Occupancy Type) Sq. Ft. sq.ft. Sq. Ft. Square feet Height Ft.&in. Single-Family Dwelling 1 Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office C Mercantile J �� Manufacturing5 Other: Attached Gara a 1, 2, 3 Type of Heating System: Electric, Oil, as Wood, orced Hot Air Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. i/ Yes _No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new,construction. Date: Applicant/Builder Signature: The application of ted is hereby approved and permission granted for th c nstruction, reconstruction or alter tion of uildin Land or accessory structure as set forth above. Date: Authorized Signature: L:\Sue Hemingway\Buiiding.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 k Town of Queensbury Fire Marshal low 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Insliection Report 1 Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructii#ns and ifi speccations contained in the Installation Manual accompanying the appliance.No deviation from the manufac urer°s instructions or iecifi ' ns is allowed. �-f 45 Permit# 0 Schedule Inspection 1U Time am pm anytime Inspectod Name 00u� _ Address- 17 YOUR _95�� Rough In___ Final Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Double Wall_ Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Will Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) WMte—� SDe Yellow r pink—Fire Mar" Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date . 20±�,S� Permit No. Application is hereby made to the Building& Codes Off ce for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: Stove: wood coal pellet gas Fireplace insert Address: t _ ,�_r it ace factu,ij wood Fireplace, masonry: wood gas Furnace: wood.: gas oil Phone: If non-masonary applicance, please provide Owner: � h`� Manufacturer Name: /r'n Address: Model Number: Ll w — Chimney Information Phone: ` ` ' (circle appropriate words) Masonry block brick stone _ Flue tile steel size: inches Exact Address: 7 r u s (t j,. y of construction orinstallation f Factory-Built 1"ter K f V,,r Manufacturer name: Model Number: Note: Listed By: Number: _ Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting Chimney Liner C&zmL tle -Aiv Department—Z'omu o.PQsxeeambuzy, Wezw Yoz-lK— - i i Fires Marshal Code# $Collected $Ref ended Received fr-onz (refunded = address: — --- — ----- ---- - A 173 3389 (190) Public Safetyf A 233 2655 (230)Ml/or Saley DATC: , t yv�wa�i-vL�— Town. �i�ct.�c oa mad, , White(Applicant} /. Green(a,ire,'Marshatl) ! ellow(BIM. Dept.) / Pink K Goldenrod(Cashier's Dept.) Queensbury Building & Code Enforcement - Residential Final Inspection&� Office No.(518)761-8256 Arrive: am/pfh D part am/pm Date Inspection request received: Inspector's Initials: NAME: U 1, — _ PERMIT#: LOCATION: QQ-Jbe-'R—1 IS DATE: TYPE OF STRUCTURE: — _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler R of Valves installed/Heat Trap/Water Temp 110 _ terior privacy/trim/doors/main entrance 36 in. athroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing_ Interior Smoke Detectors: Every level: i Every Bedroom: _ Outside every bedroom area: Mt)47, GO Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure is access 30 in.x 22 in.x 30 in.(ht.)In accessible area yawl Spaces 18"x 24"acc s, I s . ft,-150 s . ft. vents Buildin No./Address isi e f m roa Final Electrical D Site Plan /Variance r'&quirfd Final Survey Plot Plan As Built Septic System/Sewer Dept Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection 4 Office No.(518)761-8256 Arrive: am/pJ`q �<7—'-��'pm Date Inspection request received: / — as Inspector's Initials: .i PP j NAME: PERMIT#: �7 LOCATION: eel DATE: 04 3 TYPE OF STRUCTURE: _ Comm is G Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more(a)stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior FinishComplete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum _ Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate 1�� C�Cj ���• �� Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. athroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"a cess, s . ft.-150 s . ft. vents Building No./Addr s sible rom Final Electrical 7 1i Site Plan /Varian a ut d Final Survey Pint Plan As Built Septic Sys m/Sewer De' t.Inn Sticker Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent ��O ✓ VV L:\PamW\Building&Codes\lnsvection Forrns\Res. Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection /Q Office No.(518)761-8256 Arrive: am/p part: D i Sam/pm Date Inspection request received: Inspector's Initials: NAME: �CG !%C'� PERMIT#: l LOCATION: /�l.�t! DATE: Z-t TYPE OF STRUCTURE: fComments Y N N/A F { Chimney Ht./"B"Vent/Direct Vent Location. Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a?,stairs,decks patios Guard at stairwell at 34 in.or more uard at deck,porches 36 in.or more xterior Finish Co lete terior/Exterior Railings 34 in.to 38 in. Vo Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/a" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tenip 110 I tenor privacy/trim/doors/main entrance 36 in. athroom/Kitchen watertight Safet lazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: 1 Every Bedroom: __ �(v(j� d t/� '�✓ Outside every bedroom area: Inter Connected: / Battery backup: / Carbon Monoxide Detector �� —SA) Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency a Tess below grade asement stairs closed rise>4 inches (Garage Floor Pitched _ Garage fireproofing/%hour fire door/door closer Duct work Seated properly _ Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24"access, 1 s . ft,150 s . ft. vents uildin No./Address visible from road Final Electrical N � /�I/q�— C'��• Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Oka to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codesunsvection Forms\Res. Final Insv. form 2.docLast printed 2/12/04 Final Survey Inspection Dept. of Community Dev , Town of QueensburyWrag 742 Bay Road Queensbury,NY 12804 $E p 2 0 2005 Date received: •�-- - -- --- NAME: %C—U 6,US LOCATION: PERMIT#: Final Survey Plot Plan AwDroved Denied The attached final survey has been received by the Dept.of / Community / Development. 4120 Upon review the survey has been: Craig Brown, Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspectim.FORMS\Final Survey Zoning Administrator.doc o F i L Cod - �4 h N r P 1 o� O GIL 0 Queensbury Building & Code Enforcement - Residential Final Inspection �518)761-8256 ✓ Arrive: am/pm epart: am/ptn /,¢ection request received: Inspector's Initials: LOCATION: PERMIT#: DATE: TYPE OF STRUCTURE: __ Com eats _ Y N N/A a Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent throu h roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in,or more rG stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 i . Platform at all exterior doors �Z 4terie Handrails stairs 2 or more risers �Q Enclosed Stairs Sheetrock Underside minimum ''/2" / Gypsum V Grade away from foundation 6 in.with 10 ft. V, �r✓�f � le 4t L-- Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. gA,��•t, Rt 6Lk44' �lJ STD Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: i Every Bedroom: Outside every bedroom area: t,,J a,A{L t, .$A-It' T" liC/bil°C� Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixturesL L Foundation insulation b -fbrj_47rC (fs Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched / GL Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure 1^6 *x L A-re-1� Attic access 30 in.x 22 in._x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical t, Site Plan /Variance required Final Survey Plot Plan V / P,L,�/_ CEC. As Built Septic System/Sewer Dept Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/U Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res, Final Inso. form 2.docLast printed 2/12/04 Septic Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/i D part: — Pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: / NAME: ' PERMIT NO.: ( �� LOCATION: T<\rtQwk INSPECT ON: RECHECK: _ Comments and/or diasram Soil Type: an la Type of Water: Municip /Well Water Waterline se ara istance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length 'Zug ft. Length of each trench - ft. -Depth of trenches ?/ ft. Size of Stone -� Seepage Pits: Number Size: x Stone Size: _Pliping SizQ Type Building to tank c p Tank to DistributioD Box 14. L% Distribution Boxp F ld/Pit ►► Opening Sealed: N/Partial End Caps Location/Separations Foundation to tank Foundation to absorption ZS ft. Separation of Pits ft. Conforms as per Plot Plan N En 'veer Report and As-Built Y N 41ev- A4— & Location of Syste on Property: Front ea Left Side Right Side Middle Front Middle Rear System Use Status Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 1/6/05 Framing / Firestopping Inspection Report Office No. 518 ( ) 761-8256 Date Inspection request received: 7 UJ Queensbury Building& Code Enforcement Arrive: _am. Dep/art: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:�aJ�_v e �1 NAME: PERMIT#: LOCATION: 17 h INSPECT ON: � TYPE OF STRUCTURE: Y N N/A Framin ?�c COMME S Jack Stud /Hea ers Braci /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour >r stopping ; Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 36 LASueHerning% ay\Building.Codes.inspection.FORv1S\Framing Firestopping Inspection Report.doc January 28,2003�! D) (R6`'-:fT VC-0,1— Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: c-- 5 U5 Queensbury Building & Code Enforcement Arrive: am/ Depart: am/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: PERMIT I #: a LOCATION: Fa,Jer5 INSPECT ON: A e-o TYPE OF STRUCTURE: . Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head .I for 15 minutes nsuiatio / Residential Check / Commercial Check NftpLs�r Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ft - pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: _ _ J/ It Y N N/A Framing COMMEN iS/ Jack Studs/Headers Bracing/Bridging Joist hangers —z—/ Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour stopping Penetration sealed 16 inch insulation in cavity min. �A- C Lc— �� Garage Fire Separation House side '/2 inch or 5/8 inch Type X �` �� n /� Garage side 5/8 inch Type X J f l Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) A)c V 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemin-way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Town of Queensbury Fire Marshal 1 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 , fax 745-4437 Factory Built Gas Fireplace/Stove Inspection_Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the islstructi0 and specifications contained in the Installation Manual accompanying the appliance.No deviation from the minufact r°s instructions or specifications is allowed. Permit#05- /50 Schedule Inspection � Time J� (-- pm anytime '--E Name ���1 Addr s ��Rough In Final_ Appliance Manufacturer Model# Direct vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection { Clearances to Combustibles (all sides) Firestop(s) Vertical Chaste Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White—Badidfna Dept. 1'eIIow r Pink—Fire Marshal 1a—q lc>l� Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request receiv d: Queensbury Building & Code Enforcement Arrive: —am/"part: am pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Q—\ 0 PERMIT #: S l S D LOCATION: Y� INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates PlumbingVent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 5P P.S.I for 15 minutes sulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: —7 2 o ( Queensbury.Building & Code Enforcement Arrive: am/_ art: a/ m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: v NAME: S S c c' PERMIT #: 0 �— LOCATION: t 0� '�s S �- INSPECT ON: TYPE OF STRUCTURE: i Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test n�(�' Water Supply Piping Air/ Head 50 P.S.I for 15 minutes �6nsulation / Residential Check Commercial Check V Proper Vent Attic Vent lrb Duct/ Hot Water Piping Insulation If required unheated spaces Ambustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: 41&6D '1(Z�i�o1� bc�e�1 Wert l� }—�{ INCH [,J 649 LAPam Whiting\Building&CodeAnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req st received: Queensbury Building& Code Enforcement Arrive: ` _a epa am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: PERMIT#: LOCATION: ONA INSPECT ON: T E OF STRUCTURE: Y N N/A COMMENTS rFraming /Headers /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall i Fir7 separation 1, 2, 3 hour F" e wall 2, 3, 4 hour irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) i 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemin-,way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's InitialsT� NAME: PERMIT #: 0 LOCATION: , INSPECT ON: TYPE OF STRUCTURE: Y ,. N/ — u h Plumbing / Nail Plates Plumbing Vent/ Vents in Place T7 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum le nout every 100 feet / change of direction Pre ure Test- .n / Vent Head .I. or 10 ft. above highest connection for 15 minutes ressure T st Water ly Piping Air/ ead 50 P. J 15 minutes Insulation Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing / Firestopping Inspection Report V —� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: _am/ D part: _ m/pm Inspector's Initial 742 Bay Road, Queensbury, NY 12804 NAME: PERMIT#: S LOCATION: Ql�jl� INSPECT ON: - r' TYPE OF STRUCTURE: Y iv/a m COMMENTS F ing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour estopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation V` House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) _ 5.7 sf above/below grade VL �D C ksot- 5.0 sf grade I—AsueHemingway\Building.Codes.inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re est ec v Queensbury Building&Code Enforcement Arrive: pm art: a in j 742 Bay Road,Queensbury,NY 12804 Inspector's Initi s: f✓ NAME: �Z_ ` PERMIT#: LOCATION: INSPECT ON: ( n- :7:� TYPE OF STRUCTURE: �� Y N COMMENTS Xining Attic Access 22"x 30"min' m Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. O� Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `./z w) 16 gauge(8) 16D nails each side .,l�, Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received:,--, Queensbury Building&Code Enforcement Arrive: am/ �-���e art: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: J t f NAME: PERMIT#: LOCATION: INSPECT ON: 05 TYPE OF STRUCTURE: V Y N N/A COMMENTS Fr ing � Attic Access 22"x 30"minimm "���u -zC1 Jack Studs/Headers Bracing/Bridging Joist hangers )4�IAV— �`Jack Posts/Main Beams A �q�� G� �J 6 t,5 Exterior sheeting nailed properly 12"O.C. r Headroom 6 ft. 8 in. _ (� Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate n 1 `/z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour ire wall 2, 3,4 hour ✓` Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report i Office No. (518) 761-8256 Date Inspection request received: ` Queensbury Building&Code Enforcement Arrive:-am/ epart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: Y� \ PERMIT#. D S )S v LOCATION: INSPECT ON: { TYPE OF STRUCT 1 Y N N/A raining COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers 7 Jack Posts/Main Beams IAv�I,%L Exterior sheeting nailed properly J , 12"O.C. VA,C✓Z01 Headroom 6 ft. 8 in. Stairwells 36 in. or more �� Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls � G.� ��`.; ' L O SC Metal Strapping for Notches Top Plate 1 '/s w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trussesjbL/ '-���5 -tU _ q Anchor Bolts 6 ft. or less on center r/ Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour �' Firestopping _ 44c Penetration sealed 6A, 16 inch insulation in cavity min. Garage Fire Separation House side'/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade �d(�� �C /4�� I(� 27 j Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re est r c ve Queensbury Building& Code Enforcement Arrive: p rt: 742 Bay Road,Queensbury,NY 12804 Inspector's Initi '�-- NAME: PERMIT#: Z LOCATION: INSPECT ON: 10 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestoppin€; Inspection Report Office No. (518) 761-8256 Date Iispectijrre Div d: / Queensbury Building&Code Enforcement Arrive: part: �;�742 Bay Road,Queensbury,NY 12804 Inspector's Ini 1 ISc> NAME: �Iefn 1 PERMIT#: LOCATION: i INSPECT ON: TYPE OF STRUCT Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum I Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I 1 '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour ! > Firestopping ! I Penetration sealed 16 inch insulation in cavity min. j Garage Fire Separation House side % inch or 5/8 inch Type X 1 Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade L 5.0 sf grade Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ Queensbury Building& Code Enforcement Arrive: Iam/p ff epart: c am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ OCGf��%C PERMIT #: LOCATION: _ moo-u,�/!�r G(� INSPECT ON: TYPE. OF STRUCTURE: Comments Footings ------------------�__---- Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. — Foundation/Wallpour Re' forcemeat in Place oundation Dampproofing Foundation/Waterproofing Type of Dampproofing;Waterproofing i Footing Drain Daylight or Sump — Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper _ Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway`,Building.Codes.Inspection.FORM SToundati on Inspection Report.doc January 28.2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/� e Depart: � /�rri pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: Y cs�\\A� PERMIT#: LOCATION: > >" q . INSPECT ON: -� TYPE OF STRUCTURE: Comments �~ Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concret . Materia r this purpose on site. Fo ion/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. T.ASueHemingway\Building.Codes,Inspection.FORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection requ r v d: !� Queensbury Building &Code Enforcement Arrive: a p Depart: ` 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi - 1 r NAME: l P�1 `QOERMIT#: ^ 0 /50 LOCATION: \� E✓S LUC„ INSPECT ON: _�_ � TYPE OF STRUCTU E: Comments i _ Y N N/A—I otings 0 Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. h:\SueHemingwayiBuilding.Codes.InspectionTORMS\Poundation Inspection Report.doc January 28,2003 as_ Permit Number RFScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck Solware Version 3.6 Release la Data filename: C:\Program Files\Check\REScheck\2325-05 STEVENS-17 FOUNDERS WAY, QUEENSBURY.rck PROJECT TITLE: PLAN NO. 2325-05 COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.19 DATE: 03/21/05 DATE OF PLANS: MARCH 21, 2005 PROJECT DESCRIPTION: DREW & COURTNEY STEVENS 17 FOUNDERS WAY QUEENSBURY, NEW YORK 12804 DESIGNER/CONTRACTOR: WILLIAMS & WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS, NEW YORK 12801 COMPLIANCE: Passes Maximum UA= 557 Your Home UA= 450 19.2%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R-Value IMF.cto TEA Ceiling 1: Flat Ceiling or Scissor Truss 1064 38.0 0.0 32 Ceiling 2: Cathedral Ceiling(no attic) 1272 38.0 0.0 34 Wall 1: Wood Frame, I6" o.c. 1279 19.0 0.0 57 Window 1: Wood Frame:Double Pane with Low-E 252 0.320 81 Door 1: Solid 34 0.130 4 Door 2: Solid 20 0.130 3 Door 3: Solid 20 0.130 3 Wall 2: Wood Frame, 16" o.c. 1166 19.0 0.0 57 Window 2: Wood Frame:Double Pane with Low-E 212 0.320 68 Basement Wall l: Solid Concrete or Masonry 1211 11.0 0.0 76 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Floor 1: All-Wood Joist/T russ:Over Unconditioned Space 746 19.0 0.0 35 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and igned this page, they are attesting that to the best ofhis/her knowledge, belief and prokssional judgm t, uch s s ifications are in compliance with this Code. gne�r, E Date Jul_0 f REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck So$ware Version 3.6 Release l a DATE: 03/21/05 PROJECT TITLE: PLAN NO. 2325-05 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: [ ) ( 2. Ceiling 2: Cathedral Ceiling (no attic), R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: [ ) 1. Basement Wall 1: Solid Concrete or Masonry, 8.0'ht/7.0'bg/8.0' insul, R-11.0 cavity insulation Comments: Windows: [ J 1. Window 1: Wood Frame:Double Pane with Low-E, U-fcctor. 0.320 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ j Yes [ ]No Comments: [ ] 2. Window 2: Wood Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ j Yes [ J No Comments: Doors: [ ) 1. Door 1: Solid, U-factor 0.130 Comments: [ J 2. Door 2: Solid, U-factor: 0.130 Comments: [ ) j 3. Door 3: Solid, U-factor: 0.130 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/T russ:Over Unconditioned Space, R-19.0 cavity insulation Comments: i Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] ( Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. I Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and 11oors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manuficturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating 1 equipment must be provided. [ ] Insulation R-values, glazing U-fictors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Dud Insulation: [ ] 1 Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R- [ ] Retum ducts in unconditioned spaces (except basements)must be insulated to R-2.. 1 Insulation is not required on return ducts in basements. I Dud Construction: [ ) I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics(adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. 1 Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means f>r balancing air and water systems. 1 Temperature Controls: [ ) ( Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point ofthe largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ) Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. I Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 IF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(Fl 1 too 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in hiches by Pipe Sizes Ding System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5, to 4„ Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(tor fed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) f 1 Gj10 i 0 b 0 2n i fi ins __