Loading...
2005-195 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20050195 Date Issued: Monday, March 26, 2007 This is to certify that work requested to be done as shown by Permit Number P20050195 has been completed. Tax Map Number. 523400-309-011-0001-0 10-000-0000 Location: 125 FOURTH St EXT Owner. JACQUELINE & DAVID COON Applicant: JACQUELINE & DAVID COON This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050195 Application Number: A20050195 Tax 1N1ap No: 523400-309-011-0001-010-000-0000 Permission is liereby granted to: JAC,OITFLFNF. & DAVIT) COON For property located at: 125 FOURTH St EXT in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JACQUELINE &DAVID COON 125 FOURTH ST. EXT Residential Addition $10,000.00 Total Value $10,000.00 QUEENSBURY, N.Y. 12804 Contractor or Builder's Name /Address Electrical Inspection Agency CACCAVO. CONSTRUCTION 15 CASHMERE DRIVE FORT EDWARD. NY Plans&Specifications 2005-195 224 sq ft RESIDENTIAL ADDITION(SUNROOM) $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, May 05, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Queens ury; Thursday, May 05, 2005 SIGNED BY04100007: for the Town of Queensbury. Director of Building Co nforcement 57 Permit No. _ Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid -,L\C ' 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder i 11'LE,fr1Z� ►°Y1 f1 WA V Owner: C ° ��L3� ( ( Address: i 5- 2�A5 K Oft"__ %`•___ Address: Home Phone: 51 9) `1c1g - fa Z. Home Phone: Email Address: Wt, w, fo o 0rs n1g1L - 9r dress: Cell Phone: 5-19 3b I -4'0 i-I Cell Phone: FAX Phone: 5-I6 r745'_V%4y- FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: l -.Q wt CA0_66ty Address: A5 cry C(- '� i 7-12-� Phone 6 f{`yD Z- Location of proposed construction: Lot No. 10 Legal Address: Tax Map Number: _::�©! • // 1 ` Subdivision Name: Estimated Cost of Construction: $ 10,a 0 0 , — E C E I VE Proposed construction is for: Residential Use _Commercial Use APR t 1 2005 Name of Business: C,4 0"e-4y1) TOWN OF QUEENSBURY BUILDING AND CODE If proposed construction is an addition, what will use of new addition be? Sul1 r'00 m New Addition Alteration Proposed Construction 1fi Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq. Ft. sq.ff. Sq. Ft. Square feet Height Ft.&in. Single-Family Dwelling Two-family Dwelling Townhouse Multifamily Dwelling , Number of Office Mercantile Manufactur( Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil, Gas, Wood, Forced Hot Air, Baseboard, Other: &SC board W+wq��" Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes A No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Direc r of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location P;MV�,Z_ l ew construcDate: 3D 0� Applicant/Builder Signature: 1rrVA� ►'Yl The application of dated is hereby approved and permission granted for the ns ction, reconstruction or alteratio of a buil g/and ccessory structure as set forth above. — i Date: S 05 Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Queensbury Building & Code Enforce ent - Residential Final Inspection Office No.(518)761-8256 Arrive: 02am/pm De _am/pm Date Inspection request received: _ Inspectors Initials: c� NAME: PERMIT#:LOCATION: DATE: DATE: TYPE OF STRUCTURE: Comments Yes No N/A n / Building Number/Address visible from road /' /S/�� ChimneyHeight/"B"Vent/Direct Vent Location / Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Vol Platform at all exterior doors y/ Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall p � Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet _ I�C ` 6 inch clearance to sill plate _ y Gas Valve shut-off exposed/regulator 18 inches above grade Yo L) 7f � �� Interior privacy/trim/doors/main entrance 36 inches `�.. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: p Outside every bedroom area: }' Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly '$ Gas Logs in Sealed o Glas Enclosure Final Electrical Final SurveyPlot Pl As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:1Building&Codes Forms\Building&Codes\Inspection FormslResidential Final Inspection Form revised_100405.doc UUMMUINWEALIH ELEU"IRIUAL INSPECTION SERVICE,INC.Q Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL .............Cert. N 2 90106 Cut-in Card � K No �.....�................. . ... )wner............. rtX.LJ.................................................................................................. ..... xcationlg...'.........l!14; 5 4.`. ...................................................... . ................. nstallation Consisting ` f G1!.c. ........................_ ............. ..................... ......................................................................................................... .................................................................................................................................................................................. nstalled By......!Q..../}�U'1`l/",Q l-0..............................................Lic.No................................................... ................ The conditions following governed the issuance of this certificate,and any certificate previously issued is ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ttroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making i ctions at any time, and if its iles are violated,the Company shall have the right to rev k hi ce if ate. Tate... .::. . ............ INSPECTOR............................................................................................... Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Cade Enforcement Arrive: am/p art: � 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: !75' J 5 LOCATION: 57rol. INSPECT ON: a TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. � � Head or Air Supply Test (L Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If Wquired unheated spaces Co bustion Air Supply for Furnace ct work sealed properly/No duct tape COMMENTS: ^� V � ,vim A T- '��5�—tju,&/J L:\SueHemingway\Building.Codes.hvspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ epart: .# am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: c,1,,i PERMIT #: 0 5 I )% 1-0_� LOCATION: INSPECT ON: 05' TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Wat Supply Piping ooper Commercial Coo er,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/�n�I3epart: �am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: j NAME: �,l P A PERMIT#: (4� LOCATION: INSPECT ON: TYPE OF STRUCTU : Y N N/A aming COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report 2— q Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pry �art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: - INSPECT ON: TYPE OF STRUCTU Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anch r Bolts 6 ft. or less on center and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORNIS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection reque received: Queensbury Building &Code Enforcement Arrive: am/p Depart: I amlpm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: C)4- / q NAME: _ _ PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments _ Y N N/!A Footings Piers ^� Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpos,,on site. Foundation/Wallpour Reinforcement in Place T Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 ine s above footing it poly for wet areas under slab _ ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I.\.SueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Js6-e-- Vol Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: ' ���—�---- Queensbury Building &Code Enforcement Arrive: am/p_AL_ Depart: "Jam`pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: (200/) PERMIT#: LOCATION: I a r INSPECT ON: TYPE OF STRUCTURE: Comments _ Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place _ T Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I,\SueHern ngway\Building.Codes,Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 2005-195 ' �o ,,►o -� - t JACOUELINE & DAVID COONp,EC@\jED Es °c�L . 125 FOURTH ST EXT �►r t� � .1 20a5 TAX ID 309.11- -10 iI TOWN OF QUEENSIBBURY � BUILDING AND C � TOWN Of- Based UEENSBURY EUILDING DEPARTMENT ^) on 0'UT ited examination, th our cons comments shall not plan and s ed as indicating the NOTICEI. cam is �ications are in full m� a t! fiance h the Budding Codes �g[ (/] [��p,��@p gg I /� of Ne York,S te. 3 t I ISOLATION f�Ol�'6,% Rry�o Py"INUTE THERMAL -- T �I X I .__ I ov NOTICE xo r} E KRAFT PAPER INSULATION MUST BE `I COVERED BY NON-COMBUSTIBLE BARRIER --- � � ---- 15as I UL PFULDING .4 IPE+ kEVIEVVED B DATE !�`—'' trlzt- 57 C' � LH 04 f � Lf\ _`( ��, ` u [ � iW3 23 r1J rA �A A) I Ot v ZLu x 17 r C o O n� �,�•� t t��.r'7 c� PA&,Z Z 6A it Al l a Z O r � F i( I I (� i I _ Ardar5enl Andersm Windows-Abbreviated Quote Report. Project Name: CACCAVO/COON JOB Qaotc#. 017317 Print Date- 03M/2005 Quote Date: 03123t-?WS io Vernon: iQ5b-- -Pue er. CURTIS LUMBER COI%OANY j Customer: $85 RT 67 milting BALLSTON SPA NY 12020 Addrow- 519-885-5311 Phone: Fax: r-r Sales RV-* _QBVR�Y Contact Item Qty Item Sime(Qpe io Locatiox Unit Price --EEL prive -IVM56E(AA)lip411,27 S 4172,70 RO Sin=3*2 Iff'Wx 5'8 718-H Unit Size 3'1 SM"W x 5'8 7/8-1 H -Betweeo4be-6kw,Colowal,4W3H,WbA,--'Whfle,314"(Each Sash) Unit,FApW Sash,WhiteiClear Pine,High PeFforniance Glass,Finelight Grffies Insect scree,36 wilife Subtotal S 4JI7.79 Total Load Factor Misc.Taxable S 0.00 Customer Signature 2-940 Tax(G.Wwr) S-- Msc.Non Taxable S.--- 0.00 Grmd T4oml Dcater Sipamre Prqjoec;O)voments: C-D e V DSO � Permit Number MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb Data filename:D:\coon.cck TITLE:Coon COUNTY: Warren RECEIVED STATE:New York HDD: 7635 ��.r� U 1 2005 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric TOWN OF QUEENSBURY DATE:05/01/05 BUILDING AND CODE DATE OF PLANS:4/30/05 PROJECT INFORMATION: Coon Addition COMPANY INFORMATION: Caccavo General Contractors COMPLIANCE:Passes Maximum UA=59 Your Home=50 15.3%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 124 38.0 0.0 4 Skylight 1: Wood Frame,Triple Pane with Low-E 5 0.150 1 Wall 1: Wood Frame, 16"o.c. 352 19.0 0.0 12 Window 1:Wood Frame,Triple Pane with Low-E 160 0.150 24 Basement Wall 3: Solid Concrete or Masonry,4.0'ht/4.0'bg/4.0'insul 175 19.0 0.0 9 Boiler 1: , 86 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the Proposed New York State Energy Conservation Construction Code requirements. Builder/Designer Date [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on I the building plans or specifications. I Duct Insulation: [ ) I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] I Supply ducts in unconditioned spaces must be insulated to R-11. [ J I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ J I Air filters are required in the return air system. ( ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space I temperature set point of the largest zone. I Electric Systems: [ J I Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or I the New York City Building Code,as applicable. ( Service Water Heating: [ ) I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the, I levels in Table 2. MEICcheck Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release 1 b DATE:05/01/05 TITLE: Coon Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 3: Solid Concrete or Masonry,4.0'ht/4.0'bg/4.0'insul, R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame,Triple Pane with Low-E,U-factor:0.150 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ )Yes[ ]No Comments: Skylights: [ ] 1. Skylight 1: Wood Frame,Triple Pane with Low-E,U-factor: 0.150 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ] Yes[ ]No Comments: Heating and Cooling Equipment: [ ] 1. Boiler 1:,86 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be Type IC rated and installed with no penetrations, or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] ( Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Table 1: Minimum Insulation Thickuestfor Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping_S System Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only)