m � 5 �. Permit Number: P20050213 Date Issued: Thursday, October 13, 2005
m c Q o o
:3o Q o rn
o Q QOQL); "
O C O n p
m ° , ° (D0 o
This is to certify that work requested to be done as shown by Permit Number P20050213
o
� � �- 0 o'
Q -+ rnn � _
o Q Q
Q ° Q p 2 has been completed.
° cD o CDL Tax Map Number:
° ° ° Qa 523400-289-012-0001-015-000-0000
° c0 : 5
q 0 - ° Location: 20 BERRY PATCH Rd
c � � � Q�ccQ Q m
0 Q Owner: T & B ASSOCIATES LLC
Q n o Q Applicant:
a Q n o p pp T & B ASSOCIATES LLC
° (D (D � This structure may be occupied as a:
y• N V,' <D
n (D Q Q Fireplace By Order of Town Board
o07 W o N Garage - 2 Cars Attached of EENSBu
? -a ` n a :� Single Family Dwelling
-a (/) ° 0- 0Issuance of this Certificate of Occupancy DOES NOT relieve the
3 c 3
c _ P Y
o Q. property owner of the responsibility for compliance with Site Plan,
cu Q 07 0 o p Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Q a Q m (DPlanning Board or Zoning Board of Appeals.
(D (D
• �f triVlt ()� t�lil;@11$f)ll/'� .
5�;w(a•;1 aluf �t;wsiJ;C [)i�jla:•al t:Ilsi�ti(�r
A13 ondix C.
• I1-USOMI'VION IrII�I,I.)
SI:I'/1•it/1,'MON Itl:��l.J1III�l�lI��l�f'I`;�
n 17Xl) POND
lv�%Ir Witte(
• If
-sr vI 1c,
•� T1-1lxwrf
l
_..�,.�. � \ ��'•�' 1 l)t'�iitil;t 111r1 l �
•�,X
l�{yrgR:'11C1 1
h
7, Sir4NA►i'URE &MORMATION FOR rvNbwLr-rrswva-4 w19^0•,.,w•.v ::•::
Queensbury Building & Code Enforcement - Residential Final Inspection
r Offir No.(518)761-8256 Arrive: am/p a t: m/pm
Date nspection request received: Inspector's Initial
NAME: Lf / PERMIT#:
LOCATION: ILI L4Q - _ i DATE: -
TYPE OF STRUCTURE: -'
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location �d
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6" 01
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum ''/2" t7'
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110 4111
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/1/4 hour fire door/door closer lo
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access,j s ft.-150 s . ft. vents
Building No./Address visible frontr2e
Final Electrical
Site Plan /Variance required ,
Final Survey Plot Plan VA
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamW\BuildinQ&Codes\Inspection Forms\Res. Final Insv. form 2.docLast printed 2/12/04
10/13/2005 16:19 5188850613 T B ASSOC PAGE 02/02
ob
Q
c
^� r
Town of,Qftusbury Fire Marshal
742 Bay Road
Queensbury,NY 12804
761-8205/761-8206
tax 745-4437
Factory Built Wood Burning Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# - 13 schedule Inspection f c1 ice' (-�5 Time Jd-,-) am pm anytime Inspector
Name 1 .� �C Address L �.! ?r 1 Rough In Final
Appliance Manufacturer Model#
Masonry Chimney Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles(all sides)
Safety Strip Installation(fireplaces only)
Firestop(s) Vertical Chase
Wall Penetration
Chimney Clearances to Combustibles
Chimney Termination
3 feet above roof penetration;2 feet above
any combustible construction within 10 feet
Combustion Air
Hearth Extension
Mantel(height above f/p opening)
Fireplace Doors/Screen(required)
%Ike—ftnftc NIC YeII — Pink—Fire Mar�hat
Town A(ftwok ry Fire Marshal
7-42 Bay Road
Qaeena Ury,NY 12904
7614 05/761-8Z06
fax 7454437
Facto_a Built Wood Bw,MiU,,,,F�enlace/Stev_e Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications coat dnW in the Installation Manual aceompanying the appliance.No deviation from the manuf is
instructions or specifications is allowed.
Schedule In wtion�_ �` Time C?— ) pm anytime inspector
14ame+6 1 , Address Q Rough In V Final
Applince Mamdr etarer Model#
Masonry ChiUey Factory Built Chimney Flue Sbe Doable Wall Triple Wall insulated
Yes Mo N/A Commits
!:,-Ovr�t"on
Clearances to Combustibles(all sides)
Safety Strip Installation(fireplaces only)
Firestop(s) Vertical Chase
Watt Penetration
Chimney Clearances to Combustibles
Chimney Termination
3 feet above roof penetration;Z feet above
any combustible construction within 10 feet
Combustion Air
Hearth Extension
Mantel(beight above Vp opening)
Fireplace Doors/Screen(required)
wmwc > Y _ Ptak-FtM Mar and
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection re st rec ed•
Queensbury Building & Code Enforcement Arrive: am/pm pa 7-- '742 Bay Road, Queensbury, NY 12804 Inspector's I ' i--NAME: PER IT #:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes tp
lation / Residential Check Commercial Check
Proper Vent Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
I ki
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reque r v
Queensbury Building & Code Enforcement Arrive: a /p epart: am
742 Bay Road, Queensbury, NY 12804 Inspector's Initial P,
NAME: PERM #: CA _ �I
LOCATION: INSP ON: ~�
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
W P.S.I for 15 minutes
sulation / Residential Check / Commercial Check
Proper Vent Attic Vent R- C
Duct/ Hot Water Piping Insulation E1L1
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
-- 6 -Tl- fit) C-0 �=z
LAPam Whiting\Building&Codes\Inspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing / Firestopping Inspection Report r
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: _am/p 4�?ZDp j�V , A, am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials �l -Th —i
IN
NAME: PERMIT#: (:)QDS
LOCATION: INSPECT ON: _ �-
TYPE OF STRUCTURE:
Y N N/A COMMENTS
aming
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire 19,
2, 3, 4 hour
F stopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.lns ection.FORM S\Framin ng Inspection Report.doc January 28,2003
AJ
�R , iP 6—k(c . - ot<
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12804 f f
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stave Inspection Report /
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions d
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufactu 's
instructions or peciBeations is allowed. / �j
Permit# `"Z) Schedule Inspection 3 D Time am pro anytime � y/`'C�
NameY� rJ Address d lJ� li 19- G H Rough In "final_
Appliance Manufacturer v J t1 �06� Model# 6 c( —3Tb
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
No N/A Comments
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase Y
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve
Combustion Air
Hearth Extension (if any)
Mantel
Height above Vp opening
Witness Operation
Tank Placement (if LP)
Pink—Fire MarAQ
White—B�didins Dept.
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: _
Queensbury Building & Code Enforcement Arrive: am/p part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: d PERMIT #: �
LOCATION: - INSPECT ON: jN/A1
Z
TYPE OF STRUCTURE:
INSPECT
N
ou h Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
C anout every 100 feet change of direction
Pre sure Test
Pr�in / Vent
Ai / Head
.S.I. or 10 ft. above highest connection for 15 minutes
Pre sure Test
ter Supply Piping
Ai / Head
0 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received: ID]bk
NAME: 1-45 *,t)G.
u:�e a 0
LOCATION-
Tom-
PERMIT#-
6, 3�b
Final Survey Plot Plan
A roved Denied
The attached final
survey has been
received by the
Dept.of ✓�
Community
Development.
Upon review the
survey has b
Craig Brown, Z ning Administrator
Notes:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey
Zoning Administrator.doc
MAP REFERENCE: MAG"TIC AS PER MAP REF. ��—
MAP OF A SUBDIVISION
MADE FOR
RICHARD P. SCHERMERHORN
DATED NOVEMBER 5, 2002
LAST REVISED JUNE 23, 2003
BY VAN DUSEN & STEVES
LAND SURVEYORS
LOT 15
N • •
51 NE .. _ _--- _ 0ji rk*'—
_460 2_,
24 CPP
DRAINAGE —
EASEMENT — — —
� m
1 a to
z LOT 14 57,493. sq.ft. 84.47'
1.31 acre, w
>-Q STONE
o a;w DRIVE - o
o 0 00 `� P+
N o z .�; o FARMIN T N
CV 0
E 488E 42M ' ' 3 y , G i o f®WfL1 �, c'o PL
W •
459.6,7
sos 51 „W
Imp
LOT 13
(� I HEREBY CERTIFY THAT THIS MAP WAS PREPARED
FROM AN ACTUAL FIELD SURVEY.
C. Sr THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS
FOR WHOM THE SURVEY WAS PREPARED, AND ON THEIR
�L BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY
AND LENDING INSTITUTION LISTED HEREON.
CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL
INSTITUTIONS OR SUBSEQUENT OWNERS.
n
CERTIFIED TO: LYNNE M. COTTONE
SUN TRUST MORTGAGE, INC.,
13 IT'S SUCCESSORS AND/OR ASSIGNS
CHICAGO TITLE INSURANCE COMPANY
6 005
f
CERTIFIED BY:
-' MATTHEW C. STEVES, LLS NYS 50135
DATED: AUGUST 31, 2005
D ' 7 Date, August 31, 200
(� �i vHA III A AL>M LA ae RV ro A s�mveY . i
� E'er YM 9EMMG A UCEIISfD iNq 9AtVEYiORS SEAL IS A Map of a Survey made for Scale 1 =40
VIOLA710M OF SECTION 7M.SUB-DIVIMM a OF NE
NEn YORN SrAIE FDUOARDM LAW
S t e v e s M Rm OHS W>�S S
MlaIcN
NARKED W7H AN ORMiNAL a iFHE LAND SR3VEYORS -
Lc
sEx SMALL eE ro BE VAUD TRUE COPffS.'
•`ESUW.V DN�DDID„MNAC MMCEOAr Lynne M. Cottone
lltl5 SURVEY WAS PREPARED W ACCORDANCE MiH 711E
Land Surveyors 91Y 7K V O SA'M I "OF PEYDRS,W&
8Y THE NEW YDftlf STATE ASSOCIARON!K PROFlSSDNAL
LAND SURVEYORS SAD CE MCA710NS SHALL RUN ONLY
TO ME PERSON FOR WMOY Rk SURVEY HS PREPN IM,AND
CN MIS 9 AIF ro NE R1fE CONPANY.ODVEIINNENYAL SHEET 1 OF 1
169 Haviland Road Queensbury, New York 12804 M M S `M Of ME LE ON MnTV�°" ""D Town of Queensbury, Warren County, New York
ro THE ASSIGIIEES aF THE TENDING R7s7InmoM.•
COTTONE
(518) 792-8474 New York Lie. No. 50135 NO. DA TE DESCRIPTION DWG. NO. 02384-14
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart `a an
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: _ A n
NAME: _ Zk_ PERMIT#:
LOCATION: O 6g r4 T C INSPECT ON: _
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/WaterproofingI
Type of Dampproofing/Waterproofing
v
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHerningway\Building.Codes,InspectionTORMSwoundation Inspection Repoil.doc January 28,2003
Framing / Firestopping Inspection Report / C�
Office No. (518) 761-8256 Date Inspection request received: - A—
Queensbury Building&Code Enforcement Arrive: am/p epa m
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: S 5b'C ; T F 5 PERMIT#: OG 0 1
LOCATION: (,U T r20 �r rV INSPECT ON: �!3
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed-
16 inch insulation in cavity min.
Garage Fire Separation
House side %z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Septic Inspection Report
Office No.(518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: an
Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: ( SS PERMIT NO.: —�
LOCATION: �; I���-� INSPECT ON: - `-
RECHECK:
Comments and/or diagram
Soil Type: Sand Clay
Type of Water Mumci /Well Water
Waterline sea ance ft.
Well separation distance ft.
Other wells: ft.
Absorption Field: Total length 2 ft.
Length of each trench ft.
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
piping Siz,0 Type.
Building to tank
Tank to Distribution Box
Distribution Box to Field/Pit ti i�
Opening Sealed: Y/N/Partial
End Cap*
Location/Separations
Foundation to tank ft.
Foundation to absorption
Separation of Pits ft. ,,//
Conforms as r Plot Plan Y N K!�-
Engineer Report and As-Built Y N
Location o stem on Property:
ron Rear Left Side Right Side
Middle Fr t Middle Rear
System Use St us:
Approved
Partial Approved and needs to be re-inspected,please call the Building&Codes Office
Disapproved
Last revised 1/6/05
2�
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection quest iv d: _
Queensbury Building &Code Enforcement Arrive: am/pm Depart n
742 Bay Rd., Queensbury, NY 12804 Inspector's Ini 'a
NAME: IT#:
LOCATION c' SPECT ON: —
TYPE OF S TLTRE:
Comments
— V N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place��
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
� ) enforcement in Place T
/ Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Fo ing Drain Daylight or Sump
noting Drain Stone:
12 inch width00, `
6 inches above footing J
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.C:odes,Inspection.FORMS\foundation Inspection Report.doc January 28,2003
IG' /3"(n
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection reque t received: SJ72 k
Queensbury Building &Code Enforcement Arrive: am/ Depart: 'pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:
NAME: As-so qj PERMIT#:
LOCATION: --2c) R � INSPECT ON:
TYPE OF STRUCTURE: Gplt
-
Comments
T Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place G
oundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L ASueHerningway\Building,Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspectio§S:PECT
est r iv / �1
Queensbury Building &Code Enforcement Arrive: pm Depart: a
742 Bay Rd., Queensbury,NY 12804 Inspector's Ini
NAME: R/^` f�Y IT#:
LOCATION: U { ON:
TYPE OF STRUC RE:
Comments
Y N N/A—I
otings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab _
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASueHerningway\Building.Codes.InspectionTO&MSToundation Inspection Report.doc January 28,2003
ermit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release le
Data filename:Untitled.rck
PROJECT TITLE:TB217.DGN-"THE SPRINGS"
COUNTY:Warren
STATE:New York
HDD: 7635 RECEIVE
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric APR t 5 2005
DATE:04/06/05 TOWN OF QUEENSBURY
DATE OF PLANS:4/2005 BUILDING AND CODE
PROJECT DESCRIPTION:
#20 BERRY PATCH
FARMINGTON GROVE OF NEN►Y
TOWN OF QUEENSBURY
WARREN COUNTY
T&B ASSOCIATES V
DESIGNER/CONTRACTOR: r
DANFORTH H.CHRISS
#27 ELECTRIC AVE.
EAST GREENBUSH,NY 12061 Ai�FESS1'�
COMPLIANCE:Passes
Maximum UA=501
Your Home UA=388
22.6%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 23 30.0 0.0 1
Ceiling 2:Flat Ceiling or Scissor Truss 1145 30.0 0.0 40
Wall 1:Wood Frame, 16"o.c. 1345 19.0 0.0 67
Window 1:Vinyl Frame:Double Pane with Low-E 131 0.340 45
Door 1: Solid 18 0.160 3
Door 2: Solid 39 0.320 12
Door 3:Glass 40 0.310 12
Wall 2:Wood Frame, 16"o.c. 1318 19.0 0.0 68
Window 2:Vinyl Frame:Double Pane with Low-E 180 0.340 61
Basement Wall 1: Solid Concrete or Masonry 1124 11.0 0.0 72
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth: 7.6'
Door 4: Solid 20 0.160 3
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 86 19.0 0.0 4
Furnace 1:Forced Hot Air,92 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance with this Code.
Builder/Designer `'/ "[3* (- Date 4 a-�—
OF�NEW P.
g
r_
1 �� a
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release le
DATE:04/06/05
PROJECT TITLE:TB217.DGN-"THE SPRINGS"
Bldg.
Dept.
Use
I
Ceilings:
[ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments: 1ST FLR.DINING ROOM CEILING W/10"F.G.
[ ] I 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:2ND FLR.CEILINGS W/10"F.G.
I
Above-Grade Walls:
[ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments: 1ST FLR.2X6 8 FT.WALLS W/FLR.RIM&W/6"F.G.
[ ] I 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:2ND FLR.2X6 8 FT.WALLS W/FLR.RIM&W/6"F.G.
I
Basement Walls:
[ ] I 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul,
R-11.0 cavity insulation
Comments:BASEMENT 8"POURED 8 FT.FOUNDATION WALLS W/3"F.G.
I
Windows:
[ J I 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor: 0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments: 1ST FLR. SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS
[ ] I 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:2ND FLR.SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS
I
Doors:
[ ] I 1. Door 1: Solid,U-factor:0.160
Comments: 1ST FLR.THERMA TRU 2868 INSUL.FIREDOOR
[ ] I 2. Door 2: Solid,U-factor: 0.320
Comments: 1ST FLR.THERMA TRU LOW E INSUL.FRONT DOOR W/SIDELIGHTS
[ ] I 3. Door 3: Glass,U-factor:0.310
Comments: 1ST FLR. SIMONTON PROFINISH VINYL 6068 LOW E/ARGON SLIDING PATIO DOOR
[ ] I 4. Door 4: Solid,U-factor:0.160
Comments:BASEMENT THERMA TRU 3068 INSUL.FIREDOOR
I
Floors:
[ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation
Comments:2ND FLR.WALK IN CLOSET FLOOR OVER 2 CAR GARAGE W/MIN. 6"F.G.
i
Heating and Cooling Equipment:
[ ] I 1. Furnace 1:Forced Hot Air,92 AFUE or higher
Make and Model Number (loco I PmJ — 41W-f' 15V:�C[�1L'�
I
Air Leakage:
[ ] { Joints,penetrations,and all other such openings in the building envelope that are sources of air
{ leakage must be sealed.
[ ] { Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
{ with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
{ 3"clearance from insulation.
{
{ Vapor Retarder:
[ ] { Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
{ Materials Identification:
[ ] { Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] { Materials and equipment must be identified so that compliance can be determined.
[ ] { Manufacturer manuals for all installed heating and cooling equipment and service water heating
{ equipment must be provided.
[ ] { Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
{ the building plans or specifications.
{
{ Duct Insulation:
[ ] { Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] { Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] { Supply ducts in unconditioned spaces must be insulated to R-11.
] { Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
{ Insulation is not required on return ducts in basements.
{ Duct Construction:
[ ] { All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
{ (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
{ Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
{ operating at less than 2 in.w.g.(500 Pa).
[ ] { Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
] { Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] { Air filters are required in the return air system.
[ ] { The HVAC system must provide a means for balancing air and water systems.
{
{ Temperature Controls:
[ ] { Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
{ temperature set point of the largest zone.
{
{ Electric Systems:
[ ] { Separate electric meters are required for each dwelling unit.
{
{ Fireplaces:
[ ] { Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] { Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State ,the Residential Code of New York State or
{ the New York City Building Code ,as applicable.
{
{ Service Water Heating:
[ ] { Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
{ water heater has an integral heat trap or is part of a circulating system.
[ ] { Insulate circulating hot water pipes to the levels in Table 1.
{ Circulating Hot Water Systems:
[ ] { Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
{ of the heating energy is from non-depletable sources. Pool pumps require a time clock.
{
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 'F must be insulated to the
levels in Table 2.
• o
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1„ Up to 1.25` 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVACPipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
f