Loading...
2000-947 Ik TOWN OF QUEENSBURY 5 � � 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20000947 Date Issued: Thursday, March 18, 2004 This is to certify that work requested to be done as shown by Permit Number P20000947 has been completed. Tax Map Number: 523400-297-009-0001-008-000-0000 Location: 557 RIDGE Rd Owner: ROBERT & MARJORIE MULCAHY Applicant: ROBERT & MARJORIE MULCAHY This structure may be occupied as a: By Order of Town Board Porch TOWN OF QUEENSBURY Director of Building&Code Enforcement f L..:..L., .may�_o i, 4s 111116 TOWN OF QUEENSBURY Fee Paid lwata BUILDING & CODES DEPARTMENT q APPLICATION FOR: PORCHES-DECKS- Permit # 0f� DOCKS & BOATHOUSES Est. Cost •. *&€!A►rc-: 5/OX A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PLEASE ANSWER ALL OF THE FOLLOWING: The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description, plans and specifications submitted, and such special conditions as may be indicated on the permit. TWO SETS OF STRUCTURAL PLANS SHALL BE SUBMITTED WITH THIS APPLICATION. Owner of Propertp 6 ert 41 IJU ar 'urie dui 1cal P.O. Addressi st 5-5-7 J._ pJ. M ?Phone # -7 3 -2 ger7 Property Locati o all 4 e .r'''-"--f i /Q e- r Tax Ma # ` '7.09-/_ Subdivision Name pp -Ica e 5 .310',a f PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: CI�.TA ° Name: 1chcu-J er_3 Address PSI �� b O2 J S�'� � �� u�J Phone# 7c1 BUILDING SPECIFICATIONS: Type of work to be done: Porch Deck Dock Boathouse (Circle one) Size of Structure to be built (square footage) : /(off'' Foundation Material : Width l D 4 Thickness Depth of Footing, below grade: , Size of Posts or Studs: x x Long Size of Floor Joists: x x Span VErif Decking or Flooring Material : ("erred- roc/ "" How(( will Porch or Deck be fastenedr to building? 4 he - DEC 2 b 2000 5-[atria;tiw > CA km ec-it d c. l/ ,Iv �r�ven4- i- tQa T �:ti: 14, \S 5) " ref If Roof Will Be Installed, Answer Following Questions: Size of Posts or Studs: x "ic Long Roof Rafters: 2 x (0 Spacing 804 Span /Z Roof Trusses (pre-engineered spacing) : Span-- Type of Roof: Sloped Flat Shed Other (Circle one) Material of Roof: Ccr-ruyejej rrleIa f ZONING INFORMATION: TWO PLOT PLANS MUST BE PREPARED AND SUBMITTED, drawn reasonably to scale and attached hereto, showing clearly and distinctly all buildings, whether existing or proposed and indicate all set back dimensions from property lines. Show location of water supply and location and configuration of septic disposal area. Size of Property: ft. x ft. Existing building(s): Size ft. x ft. Size ft. x ft. Use of Existing building(s) : Proposed structure, distance from property line: Front yard ft. Rear yard ft. Side yards ft. and ft. If on corner, setback from side street: ft. DECLARATION To the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or not, and that such work is authorized by the owner. DATE: /-/ -0200/ SIGNATURE `7�t���,ff4ait)4./z . . n r, wner's Agency, Ar tect, Contractor REVIEWED BY CODE ENFORCEMENT OFFICER, DATE i SIGNATURE m v / fe 1 ire c } Queensbury Building & Code Enforcement Residential Final Inspection \.'. ,Office No.(518)761-8256 Arrive: `;.,‘' am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: f 3/fyr ([} NAME: ',��_ f (`; PERMIT#: k ) i I LOCATION: > _ DATE: - i 1 (� TYPE OF STRUCTURE: c _ f, r_ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more (f)(> Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Lf-s'CR Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating _ Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 1104/ 1 Interior privacy/trim/doors/main entrance 36 in. 0 Bathroom/Kitchen watertight cr` Safety glazing/Window in stairwells safety glazing U Or' �� Interior Smoke Detectors: )77i, j i ,•, Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures . rr Foundation insulation 4' � �` Floor truss, draft stopping finished basement 1,000 sf / ` [' ' / Emergency egress below grade C4, yr' or Jh y /'�,f,ti ja_ _ c 4 Basement stairs closed rise>4 inches E Garage Floor Pitched _ v A c?`` '�```1 Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification ' uired / Okay to issue C/C o i emporary/Permanent J 1 L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Residential Final Inspection f:// IV �I ` Office No. (518) 761-8256 Date Inspection request received: 3//0 oLI Queensbury Building&Code Enforcement Arrive: /,' Vi am/e�m Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ;0fr- NAME: PERMIT#: a OO ? 7 LOCATION: �"� � I�.�� R, DATE: TYPE OF STRUCTURE: 1= t oc tjirN pri,r CAA Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade r i I a / Basement stairs closed rise>4 inches u 3/4 hour fire door/door closer '"-`- C Garage fireproofing S j� Duct work Sealed properly jy�t? '' •%if 26 ~ Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area U Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert.Of Compliance) Okay to issue Temporary C/0(Cert.Of Occupancy) Okay to issue Permanent C/O(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc ited January 28,2003 Residential Final Inspection ) -- Office No. (518) 761-8256 Date Inspection •equest received: 3//C (/ 1-1 Queensbury Building&Code Enforcement Arrive: 1? VI am/pm Depart: mipm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: K'') NAME: 1'1 v[C r)tit c.t PERMIT#: aGUG La LOCATION: &i R,r), DATE: TYPE OF STRUCTURE: -� l as C (� eu Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating_ Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade ! .' Basement stairs closed rise>4 inches , %�`` L` ..) e t'c '%C %hour fire door/door closer Garage fireproofing j -, j,y Duct work Sealed properly � '° /11 Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHenungway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc ited January 28,2003 GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road C tiA Queensbury,NY 12804 Arrive /-Tv am/pm Depart pm Inspector's Initials ; NAME: LG h PERMIT# Ua / 7 LOCATION: SC? ,(c am DATE : ibE/ TYPE OF STRUCTURE: / �t RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from frees.i g for 48 hours following the pla• ment of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing VentNents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers ✓/ Jack Posts/Main Beam ✓ Air Infiltration Bather Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2, 3,4 hour Fiiestopping ....' \\ - \ \ • \ J •. \ \ '•- \ . ., \ , ' N \ \ \ \ )...) C.,.-,- Z- _ -----__ -‘---•---.=...-:- - ------___ , . -N, I . ' \ ...- ! , . ' \ i \ \ • ' I ,..1 ,.... \ \ \ ,., •.„, \ -,......, ------------ \ ., 1 ..... . 1-< 1---- i. Cr----- ..------------i co / _ I! , 113 /, , ..- ,.,i'' . 4:-.4-- s ', •,...re4:-.Q.,,,,,t-r . -, ei / / ----0 ,. T . •:, \ • \ s ,''.,.' .(. 0 4:V -.....,..-,..,„., .0 CI kit 0 VI , 1 , ! ‘1 _, ,,n ---0 ... , ... _, - • ZNNN MOO V4‘) S7UD ):0"c:x.‘, (w6A/AcP4.frg f,SLA B