Loading...
2005-230 42 TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (O.J.'U` OCCUPANCY Permit Number. P20050230 Date Issued: Tuesday, August 30, 2005 This is to certify that work requested to be done as shown by Permit Number P20050230 has been completed. Tax Map Number. 523400-316-009-0001-010-000-0000 Location: 215 BIG BAY Rd Owner. COMMUNITY WORK & INDEPENDENCE, INC. Applicant: COMMUNITY WORK & INDEPENDENCE, INC. This structure maybe occupied as a: Residential Alteration By Order of Town Board Septic Alteration Residential TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Directo of Building&Co nfo ent Planning Board or Zoning Board of Appeals. Permit No. Building&Codes Office-Department of Community Development=Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codesQaueensbury.net Phone: (518)761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder t7ylm 'Owner: Address: 1,4 XSr Address: i ZeE&S /V r— Phone: �Si ?) U/e -,��/C X :�13 Home Phone: - - Email Address: fi 7H1/1 ig (:i iyy me , 49/e6- Email Address: Cell Phone: Cell Phone: FAX Phone: 5�/8 gyp_„� FAX Phone: TOWN Person responsible for supervision of work with respect to building and codes comp"nuu ING AND CODE Name: &V N C L.M-5 /,!I- ( 5 &� fh�G tz-- //`` Address: ,�ar77<'- 0C/-L '�=t 3�`�d PhoneZy� r Location of proposed construction: Lot No. fj Legal Address: /56 RA`/ - Tax Map Number: %� `l " - Subdivision Name: Estimated Cost of Construction: Proposed construction is for: Residential Use _Commercial Use Name of Business:IYJMUif. i�� If proposed construction is an addition,what will use of new addition be? G New Addition Alteration Proposed Construction 1st Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq. Ft. sq.ff. Sq.Ft. Square feet Height F.&in. Single-Family Dwelling Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oi, Gas, ,rWood, Forced Hot Air, Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and -- - --r-- --1_---- ---,----_...- -, -._-- -_ i- - ---- - - ------I-i- -1--1---- ---1 -t -".. "---'-----1 ... _ I- 1__ _I_.-_ _._ 1l - -J---..:I---I i Application for Permit-Septic Disposal Systet Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) �161-8256 1. OWNER INFORMATION: ................«........_......................«...««................... .................. Office Use Location of installation: 5 1i/; 7 k. Tax Map No. -/ �G� File Penit No. I ' t Owner's Name:, LZ 1111,,mt Free Paid Address: �.........«..��. �T ..T........................ 2. INSTALLER'S NAME Gv.,7 PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#,bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No of Bedrooms x Computation Total, ailv Flow I i 1980 or older x 150 gal/bdrm 1980-1991 x 130 gandrm = 1991 resent 4� 57-III t`.- 110 gal/bdrm Garbage Grinder Installed yes_ / no ED, Spa or Hot Tub Installed yes 1 no ,/ �'x �l - 05 TOWN OF QUEENS 4: PARCEL INFORMATION: (circle applicable information&indicate measureme !LDlNG AND QQF Y i Tpo,grraphySoil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply Flat ) sand,.. at what depth at what depth municipal_) Rolling oam feet feet well Steep slope clay ` if well;water supply _%slope other from any septic! tem depth: absorption is ft. other Percolation Test: (To be�L pleted by licensed professional engineer or architect) Rate. per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal syste�must be designed by a lic�nsed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the isize of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: -1 ��' gallon(min.size 1,000gal.) �v Tile Field: each trench fi. Total System Length: V i I Seepage Pit(s): number of size of each: ft. by ft. Size n1 Stone to be used: # / depth or thickness feet( Bed System Size: x Alternative System: length and/or, size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Opacity: gallons 'Tow, n of (1114-mllsbui-Y j I • 5OIW-24 suul 8cwOne, IIisImssil t:tlastsit•c• . .j � �I)j)tt11t1iY t: r ' A-11N ?RVVION FIELD ' '�SI�;I',�itA'1'IW1*1 II:I;�Z�)�Itlhll�;i�t'I:� S P��.lKt+� r r• r r PONI) � �l��t� tN Ntirr�'R• ,,,�,'.� •ghee eft►Icy r�.. rt u'_�•�. t'i 1c, 7AI tY Fr10.1� , runty ...,�.----''""'"'_•--- -*" ' I Y 7, SIGNATURE &INFOpWA7I0N FM-Usru I.`s1ksLz r.�navi��►,v,n.v.v...y Rehabilitation for Four-person IRA SCOPE OF WORK FOR RENOVATIONS (Revised 5/28/04) Proposed VOIRA CWI @ Big Bay Rd., Queensbury Environmental Modifications A. FENCING Enclose backyard with the installation of approximately 100 linear feet of 4' high ctpip link fence4g at the comer of rear deck, extending directly away from the deck for 30', turning at a right angle and Mewi log�� le to the back of the house for 28',turning at a right angle and running 42'to the house at a point be"w4he main structle and the garage. BUILDING UEEN,SBURY B. CENTRAL AIR CONDITIONING -DING ANp O Install central air conditioning split system to cool all living space in the house. Main Level • Supply and install a Bryant Central Air Conditioning System (or equivalent), sized for adequate performance for square footage of living space on the main level. • Installation to include outside condensing unit set on equipment pad. • Air handler and evaporator coil set in basement and connected to condensing unit via refrigerant line set with filter dryer. • Install condensate pump to route evaporator by-product to drain. • Install disconnect and whip, per electric code, with 10-2 wiring to panel box. • System to be controlled by digital thermostat. • System to be started, balanced and test run for peak performance. Second Floor • Supply and install a Bryant Central Air Conditioning Split System (or equivalent), sized for adequate performance for square footage of living space upstairs. • Installation to include outside condensing unit set on equipment pad. • Supply and install air handler in attic space and connect to condensing unit via refrigerant line set with filter dryer. • Install condensate pump to route evaporator by-product to outside. • Install disconnect and whip, per electric code,with 10-2 wiring to panel box. • System to be controlled by digital thermostat. • System to be started, balanced and test run for peak performance. Duct System • Design and install duct system. Duct system to include supply and return plenums at air handler,sheet metal trunk line (surface mounted) sized by heat gain calculation, dampered supply runs to boots connected to ceiling diffusers to cool second floor and floor diffusers to cool main level and ample return air to balance system. Supply run under stairs and into former garage space to access new first floor bedroom and bathroom. Returns must be galvanized metal ducts. Code, Re_gulatory Requirements A. SMOKE AND CARBON MONOXIDE DETECTION SYSTEM An NFPA approved, Class A zoned and interconnected smoke, heat and carbon monoxide detection system for total coverage will be provided and installed, per applicable codes. Manufacturer to be Firelite Alarms, Simplex, Radionic, or equal. • Install detectors in each room, basement areas, kitchen and any walk-in closets. • Smoke detectors to be combination smoke / heat 1350 F detector, providing coverage in bedroom, kitchen and basement area. • Kitchen area to have restorative 1940 heat detector. • Carbon monoxide detectors to be installed in basement and living area. B. SEPARATE HOT WATER SOURCES Separate domestic hot water supplies between appliances and fixtures. Existing domestic hot water supply to by used to service dishwasher and washing machine only. New supply to be used for remaining domestic hot water (all sinks and showers). • Supply and install a Boilermate(or equivalent). • Re-plumb existing boiler with additional new zone and connect to Boilermate, to be plumbed with an Aqua Stat Solenoid with adjustable thermostat and Simmons Mixing Valve Series 5-200N (or equivalent), to assure temperature requirements. • Bathroom plumbing to be Type L copper for water lines. C. DOOR LOCKSETS Door hardware on three(3) bedroom doors,two(2) bathroom doors and one(1)exterior door to be replaced with lever-type Schlage or Series M Arrow single function,type C locksets(or equivalent). D. INSULATION Add fiberglass insulation to the southeast corner of the basement to meet NYS Energy Code requirements. E. SEPTIC SYSTEM Existing septic system is undersized to accommodate renovations. Install additional 1000-gallon concrete septic tank and zabel filter to existing; and, install a new septic tank, distribution box, zabel filter and leaching system, per plans of Jarrett- Martin Engineering. Program Modifications A. TRANSFORM EXISTING GARAGE SPACE INTO BEDROOM AND FULL BATHROOM, PER JARRETT — MARTIN ENGINEERING PLANS • Remove hardware and permanently seal overhead door. • Install 3'0"x 6'8"exterior solid metal door with hardware in east outside wall of storage area. • Install bearing plate down center of garage floor. • Raise floor by setting 2"x 12"floor joists on exterior garage wall sill and by hanging the joist off of the interior side first floor closure board to match the first floor elevation. • Insulate floor space around the interior of the garage frost wall and insulate the raised floor,to code. • Ventilate under floor space. • Frame bedroom, bathroom and closet, per engineered plans. • Install two double-hung 32" x 53" vinyl thermal pane windows (Anderson, or equivalent to match existing) in outside walls, per plans. • Rough in plumbing for bathroom with Type L copper for water lines and baseboard heat, per code. • Rough in electrical for new area and connect to existing panel, per code. • Install Y2' sheetrock on all new walls, tape, spackle prep for painting. Moisture resistant sheetrock to be used in bathroom. • Install baseboard heating sized for adequate performance for square footage of the new space. Connect to existing boiler with a separate zone. • Install no-wax, commercial inlaid sheet vinyl (Armstrong's Stone Kraft #89123 Stone Ridge style, or equivalent) and cove base in bathroom. Color of owner's choice. • Install single fiberglass shower unit with seat, toilet and vanity(Eljer or equivalent) with single-lever, anti-scald faucets (Kohler or equivalent), per plans. • Install 1 %"solid core doors for bedroom, bathroom,and closet. • Prime and paint all new and existing walls, ceilings and trim with a minimum of two coats of Sherwin Williams Pro 200 (or equivalent). Color of owner's choice. • Install variegated, level-loop Berber carpet(Kraus's Potential style, anti-microbial, or equivalent)and cove base in the bedroom and closet area. Color of owner's choice. B. DRIVEWAY PAVING Expand existing driveway to include additional parking area. Apply 6"-8" rubble base and a minimum of 2" asphalt base coat and 1"topcoat to all surfaces to approximately 2,520 square feet of area. General Notes 1. Contractor is responsible to verify all conditions prior to starting of the work. 2. All work performed must conform to applicable NYS Building Codes, NEC, and any other municipality requirement. Any electrical modification must be inspected by a certified underwriter and submitted prior to final payment. 3. Contractor is responsible to furnish and install all materials and supply CWI representative with all manufacturers'sheets. 4. Contractor is responsible to install all materials in accordance with manufacturer's specifications. Workmanship is expected to be performed in a recognized acceptable construction practice. 5. Any substitutions must be submitted to CWI representative and Capital District DSO representative prior to installation or change. 6. Contractor is responsible for evaluating and engineering of all bearing loads, all footings, and any changes to the existing conditions. 7. All work to be completed within specified time frames of contract and all sign-offs received from the municipality. BMcK, KE Revised 5/13/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.0 Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.....,.....,.. o........................................Cert. N2 89562 Cut-in Card No..................................... Owner............ .................................................. Location.....��4c...... ............................................6T4,11do, IV ............ InstallPon Consisting ....I... ............ 14/11P ...... ............................................................................................................................... ............................. .................................................................................................... InstalledBy..........................................................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of maki *"spections at any time, and if its rules are violated,the Company shall have the right toe r1hifical Datp .............. 51.................. INSPECTOR...................... ........................... ............................ ................................. M-h-NIZPA 1AF1 No- -- ? /G Queensbury Building & Code Enforcem4Resiial al Inspection Office No.(518)761-8256 Arrive: art: e a Date Inspection request received: "16 __ Inspecto NAME: LOCATION: �_- 13it � : �4Z� `-013� �2 11,7 TYPE OF STRUCTURE: ^� Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent throu h roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more(a)stairs,decks, atios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site ;� t / Oil Furnace shut-off at entrance to furnace area �1�'Y� C/ t Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing � Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/.hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in._x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Insvection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: k Queensbury Building&Code Enforcement Arrive: am/ epart7r Ti am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT NO.: S- 3 LOCATION: a C, INSPECT ON: — RECHECK: Comments and/or diagram Soil Type: Sand a Clay Type of Water: Munic' al/Well Water Waterline sepa istance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench 7 ft. Depth of trenches ft. Size of Stone S . Seepage Pits: Number Size: x Stone Size: Piping Siz T e Building to tank Tank to P sWbutien•BeK aK Distribution Box to Field/Pit N �t Opening Sealed: Y/N/Partial End Ca o N c Location/Separations Foundation to tank ft• Foundation to absorption ft. Separation of Pits ft• T Conforms as er Plot Plan Y � 10141 1 Engineer Re ort and As-Built Y N Location of S m on Property: Front ea Left Side Right Side Middlztus:,,,- t Middle Rear System Use S Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 a- Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reque rec a Queensbury Building & Code Enforcement Arrive: /pm part: r a p 742 Bay Road, Queensbury, NY 12804 Inspector's Init' NAME: �� PERM #: 0S--j30 LOCATION: - INSPE ON: QS TYPE OF STRUCTURE: Y N NIA u h Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Press ur Test a' / V tt�� P.S or 10 ft. above highest connection for 15 i ut Uxes6ure Test Water Supply Piping Air/ tjead 50 .S.I for 15 minutes sulation Residential Check Commercial Check la Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces �'� Combustion Air Supply for Furnace (� Duct work sealed properly/ No duct toe (� V: COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report-revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection jpmypart: : Queensbury Building&Code Enforcement Arrive: ` _ c a 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: C40 PERMIT#: 2w —23C7 LOCATION: oZ!S INSPECT ON: TYPE OF STRUCTURE: Y N a aming COMMENTS Jack Studs/Headers Bracing/Bridging / Joist hangers �- Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. c` Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ` � t 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) j 5.7 sf above/below grade 5.0 sf grade L:\SueHemingckay\Building.Codes.inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: 166V am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Z)X NAME: �I�i'Nr�s�� _ PERMIT#: v LOCATION: 1r iza, *4w INSPECT ON: z" TYPE OF STRUCTURE: Y N /A COMMENTS Framing Jack Studs/Headers Bracing/Bridging i Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly �l►� 12"O.C. Headroom 6 ft. 8 in. //w,- -Stairwells 36 in. or more `a I !� eel All ft T_f � Headroom 6 . 8 in. Notches/Holes/Bearing Walls C64,�� �Kc Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation. House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 tiomas J arrett, P,E. § ► ptrofessionoZ Enbinee� Percolation Test Report Pro! # Project Name: Site Location: zt5 r �``� Weather: 5u�1Pa �r Date' o¢ Time: � . 30 �,� Witnessed by: Test(s) Performed by: - Percolation Test #: I Soil Description: Amp Test Depth: 2d'` Presoak: Run #: Time to Drop 1 " Comments: 2 0- 4-9 - 3 / - 03 Cp,Q2 4 I �� r 5 J 006. 6 _ 06 37' 7jr 8 `'� Percolation Test #: Soil Description: Test Depth: Presoak: Run #: Time to Drop 1 " Comments: 1 2 3 4 5 6 7 8 12 East Washington St. 5 Glens Falls New Yor-IL fax f ti EX�S'TieJ�, c oa0 G a� Ptic. -7laN goo ID a t000 6AL � f _� i I C- -ram aLD 0 � �L�.S 1 •..t `4 _ S a