Loading...
2003-1000 TOWN OF QUEENSBURY ors742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20031000 Date Issued: Thursday, August 12, 2004 This is to certify that work requested to be done as shown by Permit Number P20031000 has been completed. Tax Map Number: 523400-297-007-0001-001-001-0000 Location: 774 RIDGE Rd Owner: HAYES CONSTRUCTION GROUP, L.L.C. Applicant: HAYES CONSTRUCTION GROUP, L.L.C. This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage - 2 Cars Attached Single Family Dwelling )4.5t— Director of Building&Code Enforcement 4ft TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 I F*1 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20031000 Application Number: A20031000 Tax Map No: 523400-297-007-0001-001-000-0000 Permission is hereby granted to: HAYES CONSTRI JCTION GROI TP. T,1,.0 For property located at: 766 RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HAYES CONSTRUCTION GROUP, 395 BIG BAY Rd GFireplace QUEENSBURY, NY 12804-0000 Single -2 Cars Attached Single FamilyDwelling $300,000A0 Total Value $300,000.00 • Contractor or Builder's Name /Address Electrical Inspection Agency HAYES CONSTRUCTION GROUP. LLC 395 BIG BAY Rd OIJEENSBIJRY. NY 12804-0000 Plans&Specifications 2003-1000 Lot 1, House No. 774 Ridge Road 2830 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AND 2 FIREPLACES $388.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, December 17, 2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at th of Qu sbtry; 'ri' , , December 19, 2003 SIGNED B for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761.8256 ! G9O M r A permit must be obtained before beginning construction. Permit File No. !, No inspection will be made until applicant has received a Fee Paid $ 1 2 9n valid building permit. All applicants' spaces on this ! l Rec.Fee Paid /y `' aapplication pplication mr ust be completed and must appear on thek v eviewed By: z'�rDI 4I y l NSo E C Applicant: `(05 ; &Lod wne : c: Address: 1. @ifs i t.r tvO Address: Phone#( ) T1Z- d1(4' Phone#( ) - Property Location: Lot Number: -+- / House Number / 7 7¢ itio6eD Subdivision Name: a cot- el, 6.-AiL Tax Map Number: -i ,07 -1-1 KNew Building: residence /commercial Estimated Market Value of Construction:$ 300/ 00 0 a Addition: residence/ commercial If an Addition,what }s&of new addition be? a Alteration: residence/ commercial ❑ No change to exterior size: residence/com'l ❑ Other work(describe ) Check Oceupaneylnformation 1"Floor 2"Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet Single family dwelling ( 21 o 15 C) 213 3 O 33� a Two family dwelling ❑ Townhouse a Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturing a 1 car detached garage 2 car detached garage a 3 car detached garage a i car attached garage . 2 car attached garage /-8¢ 4-$ ❑ 3 car attached garage a Storage building- commercial a Storage building- residential • a Other • What is the proposed height of the structure 3 t' feet 3 inches Will any second-hand or ungraded lumber be used? If so,for what? &I C Type of Heating System: electric/ oil / g)wood /(rced hog baseboard/other: Number of T irevlaces to be installed a Number of Woodstoves to be installed D List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder (4K(E6 czN4 JCT& 31($ el 6- (3ky 14-0 74 Z i)e-Z Plumber Mason Electrician Declaration: please sign below after you have carefully read the statement To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Oc• •ancy or Certificate of Compliance being issued,as requested by the Zoning AdminiQtrator or Director of B ' . and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new „•.•tructio.t Signature: _ Ar.., owner,o .+�t,architect,contractor Application for Permit— Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: Location of installation: 7 74- (a e- R Office Use ! File •Permit No Q it- Tax Map No. / / .9Fr, F aid 1 n.. �.P 2 Owner's Name: f e 5 C�7Js`�c•J 6g-0 tsulNpl Q15-QU:l; Address: Ill�= 1"l (Q �i�( 2 - �O AND C®U�I' 2. INSTALLER'S NAME : 141V C5 C4WS j PHONE NO. 712 '`t I4-Z_ 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply #of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980— 1991 x 130 gal/bdrm = 1991 —present 3 x 110 gal/bdrm = 3.'o Garbage Grinder Installed yes / no X Spa or Hot Tub Installed yes, / no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply Flat at what depth at what depth municipal '041.1 loa • 31-feet Af/c feet 'yell; Steep slope c ay water supply %slope other from any septic-system depth: absorption is f CO. other tklAJ Percolation Test: (To be completed by licensed professional engineer or architect) Rate: 7,0 minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. • Septic Tank: lZ 5©gallon (min. size 1,000 gal.) Tile Field: each trench Co 0 ft. Total System Length: 3O D ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feet ,---7" Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations wi respect to this application and agree to abide by these and all requirements of the Town of ueensbury Sanitary Sewage Disposal Ordinance. Eg, (21 c 2-(03 Signa re of sponsible person Date Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys - applicable to solid fuel & vented gas appliances / Date I i / r-- , 20 C% 3 Permit No. Application is hereby made to the Building& Codes Office for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: " 't' E ,`•`') y-rle 0 C. t< Stove: wood coal pellet gas Fireplace insert Address: 3j 5 gi G DA'1 .• i) crzsplace, factory-6ui1� wood CIA 66- t; s F;u tLt I,JY /.9, - Fireplace, masonry: wood gas • mace wood an oil Phone:.-. ` 1 ` ' Z.- If non-masonary applicance,please provide Owner: `l " Manufacturer Name: I4A-1E T1C Address: Model Number: 7 !t i Chimney Information Phone: (circle appropriate words) .,, N,apry block brick stone �, .Fl tile tee size: 776.E inches Exact Address: li if R.i 3( -0"- . of construction r installation: Factory-Built ,ra .f Manufacturer name: TS l } , ,' - i Model Number: Ti.P l Note: ` Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. ouble wa / Triple wall / Insulated / . ire �ntin , Chimney Liner 1 Ca4erhier'is Department—WitivairiA v., Queer bury-, 1V7ew Wia. 'J Fire Marshal Code II $Collected $Refunded Received from •efund d to) { • _-- ~ `' ' x _ ,_ address: e i °— - ,i il r .........°'"'"........... A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales L f f" DATE: 4. '_j _ y ketT. wtc,- 7 wn. etrit/e 02 C7r .17. "e--', .. White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / Pink&Goldenrod(Cashier's Dept.) Job Site Address: 77¢' t/ xida Date: / 2%/270,3 Owner: e C y-F. Application No. File No. 62 —/ Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req.Light Actual , l Req.Vent Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent + Opening for in Area Square Area Square i. Egress Square Footage Footage Feet , 1 i �. C E 0-N: i I C • 77 6/ L:\SueHemin gwaySuilding.Permit.FORMSWat.Light.V enti 1.Calculation.Sheet.doc OW- ENERGY CODE COMPLIANCE APPLICATION TOWNWiS1 - c-! OFQUEENSBURY, WARREN C UNTY O . 9000 HEATING DEGREE DAYS e ., Compliance Methods:Part 5 -Acceptable Practice Method— 1&2 Family Dwellingsv 'qv Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwe ��� ANC' srit,1 ; Multi-Family Dwellings(3 Stories or less)' "_ Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: .( Cal,N 6Ik V(9 4l.,D Ce-1' O PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area- °' 3 ° square feet 2. Type of heat- Electric Oil X Gas Other 3. Is building mechanically cooled? yes No 4. Percentage of area of windows and doors Over 17% Under 17% • 5. R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND)TO R VALUES AS • SHOWN ON PLANS SUBMIlTbD: a. Roof R 3$ b. Exterior walls R ► — c. Glazed areas R 2-. 5 d. Exterior doors R 4, 1_12„5` e. Floors over unheated spaces R 3 C) f. Edge of slab on grade(heated building) R NA g. Basement/cellar walls(above grade) R Pt/l h. Basement/cellar walls(below grade) Rom_ i, Heating/cooling-ducts-piping in unheated space R tfk 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code >4 Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED A!licitore Date Phone Number INSPECTOR'S MARKS: Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/p ern/.Mcarn—/pm Date Inspection request received: Inspector's Initials: NAME: . •r PERMIT#: -/000 LOCATION: -� �' 4�%�Q DATE: 3' / c TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete IGuard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''A" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating 45rAte_ � X4--1‘ Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 vV(,,A h VU Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: /AJfPçLL UCCn,1\GL C' PWCC'-' e Outside every bedroom area: ` Inter Connected: / Battery backup: ��k'P Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sg. ft.-150 sq. ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required �R Final Survey Plot Plan 1`� C6�,((g /d l p w d �U� v/Q Uf^� As Built Septic System/Sewer Dept.Inspection Sticker _Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Residential Final Inspection Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm 742 Bay Rd., Queensbury, A 12804 Inspector's Initials: �t�3_� �� NAME: PERMIT#: LOCATION: p ter g,0 I DATE: 8§0 2.7 TYPE OF STRUCTURE: Comments X N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors _ r Interior Handrails stairs 2 or more risers C c,(1 O I s. Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade C.,` rT Gas Furnace shut-off within 30 ft. or within line of site Cg.�v16Oil Furnace shut-off at entrance to furnace areal Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /y Plot lj required /f j 6(( R6V15642 UUC�Final Surve Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/O(Cert. Of Occupancy) / Okay to issue Permanent C/0(Cert. Of Occupancy) J U kv FjY AFjP1(6tfit(/ L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28, 03 TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 40. 742 BAY ROAD QUEENSBURY NY 12804 (518)745-4447 /��, � ARRIVE: DEPART: INSP: __ FINAL INSPECTION REPORT � COMMERCIAL MULTIPLE DWELLING (hotel, motel, apt. complex) DATE INSPEC I' N REQUEST RECEIVED: NAME 7`� LOCATION 7 7 ( `v )() tR 0 J DATE Y ""/J (IL! PERMIT ij 02 76-6 6> TYPE OF STRUCTURE 3 T FOOTINGS BACKFILL FRAMING PLUMBING_ INSULATION N/A YES NO CHIMNEY/"B" VENT/HEIGHT PLUMBING VENT/FIXTURES ROOFING EXTERIOR FINISH HHEATING/HOT WATER RELIEF VALVES FLOORS FOUNDATION INSULATION , INTERIOR STAIRS/RAILINGS , gTOCKROOM ENCLOSURE . FIRE/DEMISE WALLS PENETRATION FIRE DAMPERS CEILING FIRE STOPPING FIRE DOORS/CLOSERS EXIT DOOR HARDWARE EXIT STAIRS/RAILS PLATFORM/ELEVATOR HANDICAPPED ACCESS HANDICAPPED BATHS HANDICAPPED PARKING FINAL ELECTRICAL SITE PLAN/VARIANCE REO. �fj NAL SURVEY PLOT PLAN, IF REQ l OK TO ISSUE C/O OR C/C `p tivT D2t1,ewA9 VE ri'v'llsNitl) ,a `` Queensbury Building & Code Enforcement - Residential Final Inspection Office d:(S18)761-8256 Arrive: am/p D art: 3 •57)arn/pm Datepection request received: Inspector's Initials: NAME: PERMIT#: 6 '- LOCATION: i� — "iQ DATE: TYPE OF STRUCT S4- . Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake (✓ 3 inch Plumb Vent through roof minimum 6" -- ' Roof Complete/Exterior Finish Complete `' l ..r, Guard 30 in.or more @ stairs,decks,patios ✓ !7 by Guard at stairwell at 34 in. or more ✓ Guard at deck,porches 36 in.or more Exterior Finish Complete ✓ Interior/Exterior Railings 34 in.to 38 in. / Platform at all exterior doors ►// Interior Handrails stairs 2 or more risers ✓ I Enclosed Stairs Sheetrock Underside minimum '/2" Gypsum / Grade away from foundation 6 in.with 10 ft. V/ Handrail Termination at Newell Post or Wall it/ 6 inch clearance to sill plate / Gas Valve shut-off exposed/regulator 18"above grade �//r Gas Furnace shut-off within 30 ft.or within line of site ,/ Oil Furnace shut-off at entrance to furnace area ` Furnace/Hot Water Heater operating Low water shut-off boiler qi Relief Valve(s)installed/Heat Trap/Water Temp 110 / Mo [ D� V"\/�r tv v, 1,1`) �`v 4—4" Interior privacy/trim/doors/main entrance 36 in. li Bathroom/Kitchen watertight ti ( 4--LA<k'_ VP-t_0C- L-c 4-r/ 0 A) Safety glazing/Window in stairwells safety glazing / Interior Smoke Detectors: / Every level: r Every Bedroom: ✓ Outside every bedroom area: `,1/3tf,4.t,L �jQi/te F.P, 6'1°176-4)1jf:r Inter Connected: s / Battery backup: / 4 C� Carbon Monoxide Detector r// Bathroom Fans, if no window ✓ Plumbing fixtures Foundation insulation ✓ C f(7 7 � /t//6�5 f>&J Floor truss,draft stopping finished basement 1,000 sf /� Emergency egress below grade �/ Basement stairs closed rise>4 inches Garage Floor Pitched ✓ Garage fireproofing/'/<hour fire door/door closer �✓� Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure V Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"ac ess, 1 sq. ft.-150 sq. ft.vents ✓Building No./Address vis le frt ro d Final Electrical 1 ) C°,C l// Site Plan /Variance requi ed / 41&&DS f,°^v��/ Ina1 Survey Plot Plan ,�f Ks Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res.Final Insp. form 2.docLast printed 2/12/04 1 7 -- 4 0/5/5 -,,,...s. g,„0,,,, ,i_veii a ga) No.1.6.,y610- -.0ba 1 / -\-, . o .�.' \' p906L� o ba / 4 . ( 2 ..i,,,,,'klacll i Ili \1., alec7,1- c(3/0/ - c 2 A w Town of Queensbury Fire Marshal clizza 742 Bay Road (41,1, Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or sp .ifications is allowed. Permit# Ii Schedule Inspection 6 v/ Time am pm anytime Inspector(� Name G Address / 76, - "et) • Rough In Final, Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall __ Insulated Yes No N/A00 Comments Floor Protection ` 5 .OX Jo Clearances to Combustibles (all sides) 0 ter . 2- CZ. ,�2. Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White-Building Dept. Yellow-Cu tamer Pink-Fire Marshal COMMONWEALTH ELECTRICAL Main Office 1 6 O INSPECTION SE MUNICIPAL CERTIFICATE Run Road-Manheim, 45 PA 175P INC. Permit No. - ELECTRICAL APPROO VAL Owner.., a Cert. N9 ......"</-- -- �5938 cut-in lsi Card Location,.• 2 ' 1/4P•Y Installation .7. tin / B of.• r. j ` tall pZ ......................... ........ ........ ............ CbAte. ........ 0'A .. Installed B ..................... .. ••ry...... y.......f k e-Z- ems- �...... J......... The conditions following............................................................... ............... ............................................ .......................... cancelled:- governed the issuance ' ' Ltc•No. This ertificate... issued certificate only of this certificate,and introduction Y covers the any certificate of certificate only electrical previously he Inspectorsequipment or alterations, and installation issued is rules areu violated, this Co ations,applicationconditions Company shall have the shall be promptly as f date. if its Date..•• �7i 7- the Co pany shall have the right toleee of makin spections matade for inspection. .................... hi ific any time,................... INSPECT .......... and if its ..................................... Member N.F.P. A•>1.A.E.I. �� Town of Queensbury Fire Marshal 742 Bay Road 'lle' � Queensbury,NY 12804 76. 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or s ecifi 'ow is allowed. Permit# 0 Schedule Inspection Time ,4"" ` am pm anytime Inspector 44) ---' _ V-- Name Address k p&G �['D - Rough In Final, Appliance Manufacturer._ _ Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection 0/0 L 1 i � (2—'v--9 1"7--f' earances to Combustibles (all sides) /Firntop(s) Vertical Chase Penetration j V E Cttke5 ,W/Wall Penetration � Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement (if LP) White—%NW;Dept. Yellow—Customer Pink—Fire Marshal Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's ,�j� instructions or p ifi 'ons is allowed. �} Permit# v 3 ----/U i? Schedule Inspection 7,8 0 Time Z• I am pm anytime Ins or'P Name tk0;) t-S Address R.. i,4,&- 2 Rough In Final Appliance Manufacturer —Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection /Clearances to Combustibles (all sides) Y , irestop(s) ==on A b< kektu Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White-Building Dept. Yellow-Customer Pink-Fire Marstod Town ofQueensburyFire Marshal *prizes 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace I Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or s ' cations is allowed. :jb0 : / im anytimerR C`�—� Appliance Manufacturer__ I pc G-�_ pvs'3 '-Z Model# Direct Vent Factory Built Chimney /Flue Size ___ Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection 11r - IS aee' r-43612 Clearances to Combustibles (all sides) Firestop(s) Vertical Chase / � p P( } Wall Penetration / __ C1/[_ Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof iJl penetration;2 feet above any combustible CR4til l ' L. C L tk1 0�'" construction within 10 feet Gas Shut-Off Valve D Y Combustion Air [MA X 06{77-- D F- S k( U-- ).5 tt Hearth Extension (if any) 2_ I i 10 S r V - R d fry. SK Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White-Building Dept. Yellow-Customer Pink-Fire Marshal Ca-r- 4/ A ( Framing / Firestopping Inspecti Report .� Office No. (518) 761-8256 Date Inspection reque ceiv : Queensbury Building&Code Enforcement Arrive: a pm D 742 Bay Road, Queensbury,NY 12804 Inspector's Initial • c NAME: b44(1- -1S' PERMIT#: _4 4 — ire LOCATION: 7r71, .c Jke, INSPECT ON: cel TYPE OF STRUCTURE: 4-5 f , v � V•T N/A COMMENTS Framing rf S S C 1 Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 ...,.... 4/ALL, IeiUUJ/OU4 4 �att Two: 'Twee Type 11 Oly-7 1y . E16172711 �' ROOF TRUSS 1 1 1 HATES 14.00042 , 12C w I' Id04 Reference(optonel) J Romero Structures.Sl-Y41tot Bee. 5.200 a Jen 16 2004 MITek Industries,Inc. Fn Mar 26 14:24.35 2004 Pogo 1 ...—_,S-4.0 t 7.6.0 I 9.2-0 ( 10A-0 {,_: 17•&1 .I 21-0-0, 1, 7F11 I 34-0 4-2.1 14.0 4.e-a 2-11.0 3.11.8 4-7-5 Scale=1:5e.0 :e II ATTACH 2X8 SPF NO.2 SCAB TO BOTH SIDES OF TRUSS WITH 2 ROWS OF 812(.210 DIA.)X 3'WOOD SCREWS G SPACED 3.0'O.C.STAGGERED FROM EACH FACE. 734e; DO NOT USE DRYWALL OR DECKING TYPE SCREWS. 5xe= SCRE7S. 7a11 .- 544= / F rt] G.[a H 12.00t2 _ /) 3a6-- / 91 C /r 4.,e/2 \ ate= / ° IN\ ' 7s s. ql A N M G 5.rye D 768- sn= etto- 46.4=P 12.00 FIT L K 3x5 II 1;14 q axe= 0- a ex10,tt` 4.10-4I 34-0—I Tae I 11-0-0 H 13.9•o I t7,-9 z, -a 1 26-34 o•to-0 2-0-0 4 2.8 4.2•a 2-0-0 3-11.8 3.11-e 4a-0 TRUSS ONLY BEARING ON o.s.e 1 1/2'AS SHOWN Plste_Offsets(X.Y): IA:0.0-4,0-0-81,LE:0.3.10,0-2-B],IF:0-3.8,Ed°eLIH:0-4-14.D-2-81,1I:0.3 4,0-1--12L(L:0-843,0-5-12)ti1M:0S-0,0.3.6L IP:0-2.0.0-1-121 LOADING(pef) SPACING 2-0-0 CS! DEM. In (loc) I/deft Ud PLATES GRIP TOLL 65.4 I Plates Increase 1.15 TC 0.70 VOrl(LL) -0.29 M-N >990 240 MI120 197/144 TCDL 10.0 Lumber Increase 1.15 SC 0.85 vert(TL) -0.37 M•N 2.805 180 BOLL 0.0 Rep Suess Incr YES WB 1.00 Horz(TL) 0.27 J nee n/a BCOL 10.0 Code IBC2000/ANS195 (Matrix) Weight ISO lb LUMBER BRACING TOP CHORD 2 X 6 SPF No.2 -Except• TOP CHORD Sheathed or 3-0-4 oc puffins, 'steer end verticals.end 2-0-0 of puffins A-D 2 X 4 SPF No.2,E-H 2 X 4 SPF 2100F 1.8E (3-4-11 max.):E-H. BOT CHORD 2 X 4 SPF No.2 'Except' GOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except•. M-O 2 X 4 SPF 1050F 1,5E,L-M 2 X 4 SPF 1850E 1,5E 6-0-0 oc bracing:A-P,O-P. J-L 2 X 6 SPF No.2 WEBS I Row et raider E-N.F-L,G-K WEBS 2 X 4 SPF Stud 'Except' 0-N2X4 SPF No.2,IJ2X4 SPF No.2.B-02X4 SPF NO.2 REACTIONS (lb/size) P=2354/0-5-8,J=2117/0-4-6(input: 0.3.6) RECFO\ED Max I4orzP=19B(load case 6) P Max Upli7P=-52(load case 8).J=-900oad case 8) Max GravP=2354(ioed cast 1),Je2762(load case 3) tFy FORCES (lb)-Maximum Compression/Maximum Tension III '� TOP CHORD A•Be-59/193.B-C=-3484/317,C-Os-2691/142,0-E=-2923/196,E-F=-3809/217,F-G=•28431159,G-H=-1799/140, TOWN H-1=-2844/116,1-J=•2702/101 YY Qr \ n BOY CHORD A-P=-59/33,O-Pe-378/214,N-0=353/2346,M-Ne-249/3344,Lad=-25513808,K-L=-162/2588,J-K=-35/257 BUILOf�1 �' E Y WEBS C.O=-1 512 8e/474,C-N=-721/198,0•Ne-207/3652,E-N=-3094/196,E•Me.33I860.F-M=-158/2176,F-L=-28956, �.���� ;1j (�' �� G-L=-34/487,G-K=1418/162,H-K=-19I812.1-K=-86/1590,16-Pe-1855/,70,B-0=-206/2701 NOTES 1)Wind:ASCE 7-98;90mph;he25h;TCDL=4.8psf;SCDl=6.0p1f;Category II:Exp 8;enclosed:MWFRS gable end zone;cantilever left O� NE4/ and right exposed;end vertical left and right exposed Lumbar DOL=1.33 piale grip DOL=1.33. j. 2)TCLL.ASCE 7-98;Pg=85.0 pet(ground snow);Category II:Exp B;Partially Exp.;Ct=1.1 �P'� P.STFiz O� 3)Unbalanced snow loads hare been considered for th s design, a�� . 4)Provide adequate drainage 10 prevent water ndin 5)This truss has been designed for a 10.0 psi bottom chord live load nonconcurrOm with any other live Toads per Table 1607.1 of IBC•00. - Q 4 N 6)WARNING:Required bearing size at joint(s)J greater than Input bearing Site. .. 7)Pravda mtth3nksl connection(by others)or truce to bearing dart Capable o(wlthatending 52 lb upuh at joint P end 90 lb uplift Cl Joint r s ` 4 e J. ter, w•-'P 1,- �'� 2 LOAD CASE(S) Standard N�4D No 67'102* kN- ROPESS%04 V March 30,2004 1 aWAxnrag•Perth r.cf�rs p..emeotra ono ASAD no7..OW tale AND arcwD�s r iel-PERESCE PAGE M".>.rs WOES DEL [WOK SING,By Opfrlc bud tar use n pv wih MTiR COnlq.coe methe aac.oi 4 Dated only noon parpm tendbh yof Srtrw B for ,,••3•�I ad.n r .itteo'g m APp4cotteN of oesipn pTOAliMery and Praltu mcarporolon of 0.,,,yteA.anr I:rasbornlbiM of b,:ldn9 daeascr.vol Iris:deapn•..,.xrrtrJnq tnavm rs Ip lalaol wypsrI or indmauoi web members only, Adaulanol lomoarary bracing lb Inn/e.today Ovine cow 4uce,an it Inc resoonslb411y or the • .,4c10,.Aduuana permanent braein0 Mine overall IOUErwe r.the IesOOnli07rly Of ra Medina designee,for 9+nnre guidance rrg0r0r00 A i ll Ick Ain lair quay ico,caIron.quy Cane01.Sroropa,delivery.ereclion oro7 MnCInp,Contutr A14L/Ten Quality Criteria.OSLe1 and IC111 ivlldtn9 Ceeesonenl SNP. IMmEdonion orolbn a*airuble Iran,Trull PlowIn:alu lc.583 O'Onobro 1)riwr.Maclean,WI S3711 Ula SounIG Z7932 I7t (,twc R°AD ' Y'RUyS ke PAA F 2 4 8 cAct( 5(OE 3 JG i Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p4 epart: ; ' am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: ��C� ' NAME: 1 - PERMIT #: LOCATION: 7 7 eico,e2 , INSPECT ON: `3/ /G TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min..Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping (IR R("C( ( o Cooper Commercial Cooper,CPVC,Pex One and Two-Family 4insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspecti n Repot [/L/I 0Z. Office No. (518) 761-8256 Date Inspection r-•• eive.: Queensbury Building&Code Enforcement Arrive: D-part: a 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s: It NAME: PERMIT#: C A (_ LOCATION: '7 L 1 ' () c INSPECT ON: c'i, TYPE OF STRUCTURE: Y V/A COMMENTS(...? Framing Jack Studs/Headers V.-�_W7 Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. '01/ Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. �-� V V ,,`` Notches/Holes/Bearing Walls ..- -j-i_ t\ v7 Z�v Metal Strapping for Notches Top Plate V.L Z- 1 (� 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fi're 12., 3,4 hour tt i estopping )t\-€^�'�1 `�- L�� Penetration sea ed 16 inch insulation in cavity min. ��'`��� `'�' Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall`. Windows Habitable Space/Bedrooms \ 24 in. (H) ,/</ 20 in. (W) e` 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 "4-K-1":)//1:4111/ in Framing / Firestopping Inspection Report -'Iy' 6 - 256 Date Inspection re u-: re,-' 'ed: �t Office No. (518) 7 1 8 p q Queensbury Building&Code Enforcement Arrive: a►fpm b ep. 742 Bay Road,Queensbury,NY 12804 Inspector's Initials. NAME: 1 l C `-' PERMIT#: 3 / l LOCATION: L i o c.*7 INSPECT ON: TYPE OF STRUCTURE Y N NIA COMMENTS Framing �✓CA dc Jack Studs Headers — Bracing/Bridging Joist hangers v't - t�F� T \�v ` �.� t. Jack Posts/Main Beams Exterior sheeting nailed properly `7 i=�L- --- 12"O.C. )C A.. Headroom 6 ft. 8 in. Stairwells 36 in. or more �- - v\ \e G.- Headroom 6 ft. 8 in. -' ti Pr\? 5 Notches/Holes/Bearing Walls � iTo Metal Strapping for Notches Top Plate �� � tJ S 1 1z(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 / ice.\ ; c,-,t ,_6 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection requestregeived: Queensbury Building&Code Enforcement Arrive: anatpm D art;_ a 1 --) 742 Bay Road, Queensbury,NY 12804 Inspector's Initial t NAME: L I ,} PERMIT#: r (__X 1CLOCATION: C..( C;— jC-) S INSPECT ON: ���L TYPE OF STRUCT R Y N /A COMMENTS raining S\i,� Jack Studs/Headers (:--'`Gv* A.F--� _ Bracing/Bridging T Joist hangers �R'\.L_N, �-'�\') Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses / Anchor Bolts 6 ft. or less on center V Ice and snow shield 24 inches from wall f Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour \ Firestopping - k,`L—K. __.LE-J i\c‘ Penetration sealed - _. 16 inch insulation in cavity min. 6 --1k C—L1I.. o Garage Fire Separation -- i - House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.lnspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 • e.- t "3,5t-17,5(xi Vic' e/ It' Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ re ived• 3 `T Queensbury Building&Code Enforcement Arrive: O'. e :\\^ e 742 Bay Road, Queensbury,NY 12804 Inspector's Initi • NAME: Mq PERMIT #: ° �- T6')o6 LOCATION: 77V e INSPECT ON: 3)a v y TYPE OF STRUCTURE:T / ---;> Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents J Cast Iron, Copper Drain/Vent/Comm. V ,�- lumbing Vent/Vents in Place / ), ,`/�Rough Plumbing/Nail Plates 1 1% inch min. Drain Size C 1-1 c'—cE ,��� -� �,y, t�+.) (fi C., Washing Machine Drain 2 inch min. ✓ LE-FTbF� F+rctv3t. C— El3T Head or Air Supply Test ./ Drain and Vents 5 PSI or 10 feet above highest �,/ connection for 15 minutes Cleanout every 100 feet/change of direction / Water Supply Piping Cooper Commercial PVC,Pex One and Two-Family Insulla• esidential Check/Commercial Check ��-- "' Proper Vent,Attic Vent /�--� \ik c,17 Duct/Hot Water Piping Insulation tA t;'1., c F'`'cY If required unheated spaces / „�, Combustion Air Su l for Furnace ' c z,r.� PP YF. L=:�C --_. o C3 Gee Duct work sealed properly/No duct tape , ki COMMENTS: flvh . Vt.t., ' ,uF ►`J c r T1 EM) ilv U v.)tt ...1.� Z,i;x-N FvvL;� C� tip \ „ ` :\ LPk � v u 0 Ce7L (is) Li J ti.)t)14) t N(A, wA tJ'S? � ccm C7-6M, L\SueHemingway\Building.Codes.Inspechon.FORMS\Rough Plumbing Insulation Report.doc November 17, ��� ?L�� '�/� - Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re• ived: Queensbury Building&Code Enforcement Arrive: . it le : �? a� 742 Bay Road, Queensbury,NY 12804 Inspector's Inifr NAME: � Q1C,'T1© PERMIT#: Z_____ LOCATION: 17 \ (ID INSPECT ON: 3—�-�►--Oy TYPE OF STRUCTURE: Y N N/A COMMENTS Framing 7/� �l Jack Studs/Headers / Bracing I Bridging '" T' Q'�‘� Joist hangers '�f Jack Posts/Main Beams J 'CV'` V\ Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 �2 - \ e- l�1 L-7 Framing / Firestopping Inspection Report /1A Office No. (518) 761-8256 Date Inspection reque ceived• ✓/ / / ' OD Queensbury Building&Code Enforcement Arrive: a pm De rt• - °" ' am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial I NAME: LAQ,9 PERMIT#: (� LOCATION: -7'7 ck (J ki lC INSPECT ON: - — TYPE OF STRUCTURE: 0 Y N N/A COMMENTS 0 gaming _ Jack Studs/Headers Bracing/Bridging r Joist hangers )9—‘1C)Lylt7 L. � ) LA•c-= .. Jack Posts/Main Beams Exterior sheeting nailed properly — MN) IR 12"O.C. v\V 2 Headroom 6 ft. 8 in. Stairwells 36 in. or more .7 h? ---i\ --k`aa\ Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls L� 1 L�c _ Metal Strapping for Notches Top Plate � 7 6?^ .._) 1 %2(w) 16 gauge(8) 16D nails each side _ ��U`/" �� �. Draft stopping 1,000 sq. ft. floor trusses bCCC — Anchor Bolts 6 ft. or less on center / \ •:v a and snow shield 24 inches from wall - C-_�� bc Fire separation 1, 2, 3 hour ,� Fire wall 2, 3,4 hour T tom'"7 S? (�j�� Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 ` 4 Foundation Inspection Report 2....4) Office No. (518) 761-8256 Date Inspection re. - t re -1 •: Queensbury Building&Code Enforcement Arrive: . pm -part: 0 •, pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi. NAME: PERMIT#: (� LOCATION: ? �� INSPECT ON: 7 — /3 —D TYPE OF STRUCT RE: Comments `;C 1�A `�`� Y N N/A ootings Piers J� Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 r a...,,,e,,,,-..z....____ Septic Inspection Report Office No. (518)761-8256 Date Inspection r:.uest e Queensbury Building&Code Enforcement Arrive: am/'c i epart: -14 am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Ini •• , e. - NAME: te r � � Pi ' IT NO.: o3—/ 06 LOCATION: •--7 7 y �` � 1/ y Pit ON: RECHECK: / Comments and/or diagram Soil T Sand 1 Loam/Cla Type of unieipal gjl W F‘.,L._, \,Z- L�\ ` 1 Waterline separation distance ft. Well separation distance V-a1 ft. Other wells: _ ‘r-,c.)-'-ft. Absorption Field: Total length 7, ',It. Length Length of each trench ...% hs<lit. Depth of trenches _ft. Size of Stone Seepage Pits: Number 4.'� Size: x • Stone Size: • Piping Size Type Building to tank j{ 1 y L-{-j i Tank to Distribution Box t4...t! `tom Distribution B • ld/Pit Li n 'U ,� Sc., Opening S ed: Y/ /Partial { Location/Separations Foundation to tank . ft. Foundation to absorption ?. ft. Separation of Pits ft. Conforms as per Plot Plan _Y \i� 1 4 Location of System on Pro y: Front _Reareft S• Right Side Q.4) L 2 %- ,L,t ` \ Middle Fr iddle Rear System Use Statu : Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:'\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 -10 Foundation Inspection P ection Report �° Office No. (518)761-8256 Date Inspection req st ec 've : Queensbury Building&Code Enforcement Arrive: a pm Depart: a m 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial NAME: P IT#: �-/3 /(/O LOCATION: "� 7 II �1� 66-€ - SPECT ON: /'ol- 9 -93 TYPE OF STRUCT RE: ) �c- Comments Y ' N N/A Footings —Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Fowl.:tion Dampproofing • t unda •.• aterproofing T .e of Dampproofm.1/Waterproofing o — a n Pay fight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab • PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. • L\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 ,1` ? . Foundation Inspection Report Re ort DOW Office No. (518) 761-8256 Date Inspection requ- r - -•: Queensbury Building&Code Enforcement Arrive: a pm Depart: ' a pc 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi, s: I NAME: ____OS6 E.2�6 P:' IT#: Z -3 — teck: LOCATION: 7—114 p x Q Rr, T� I SPECT ON: \Z— 254 —Cy" TYPE OF STRUCTURE: ci,�`c) wA 7 cc . k ?, Comments Y I N_ N/A Footings Piers • Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place r Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing ,.w V Footing Drain Daylight or Sump /Footing Drain Stone: 12 inch width 6 inches above footing ( 6 mil poly for wet areas under slab ', �, / Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inception request eiv 2. i ,- Queensbury Building&Code Enforcement Arrive:0 a r Depart: O a pn 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:✓: NAME: fI��lYe Colv 'vt U(i 0✓> PERMIT#: ( ' 3 —/U LOCATION: ",� ( \' , j�i� INSPECT ON: ) /1 i j TYPE OF STRUCTURE: Comments Y / N N/A ,,Vootings \(J ``Piers Monolithic Slab Reinforcement in Place U C._ UB c 14 s� The contractor is responsible for j/ providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 • , ` S05'06'00"W 2 4-0.54' 4 20.60' • - 1 r______ _______ ___ 180.06 . SATELTE DISH �� � 764° 2 1 Pc o SOT 1 a' 71,923 sq.ft. ? LOTXI '� &" 1.65 acres �� a `" 58,967 "0cft• t,, ATI }g ^ � 1.35 1; asp M t 3rC9 I. , z co Z kii )(.......... o f pp+® cv BeaJ IPF -I / `2 2/ 1 ``-'---- 1111 p 0 lila HOUSE O�f '� —_`.""-_- g °i 3 - -- - _�_! • 71-.4. F F ft d'4 a t ? -,. tip-issip A � .� : :fit)- °s• '"� a.t os'e g 7 r r.•rt I sse�,uilf f - • I aita�•Ea��a , Fars ��� .. ` e 4 par�asa 4a �raa� rl i . - ;'• • - • '` " • . •. , . efs ..• N075'09 E 35 < yI - .. z. • v .- N077 , ]99 65• GE R .... 4 rM'- 110(1-e IVA'0 1,0 .1-) . .1\4 - w yORJ Job Site Address: " 774- �4� Date: 12 /?/d.3 Owner: 1:4-tr c-S C i'. Application No. File NoO3 -- /�s O l WINDOW SCHEDULE Window Window Mfg. Window Unit or 1 ., via i�� $Q T ° T SQ,�1, blear Clear Special Hardware or Number or Name Model Stock Op " R,i . e0�g . ..'r)essttV sib V ass/Cl.ax O ening Q.�xL lght Instructions Letter on Or T e Number „1 :, x `% �' " ° a In ches Plan Call Size g �a,18 31 ,,z_> ;: :, , m i day?° '`�a G4 q,•;° ° .-� • !. 7 Le........)p,,,,...\-: (-I k''"1 _ W al -THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES s� ., s �g s r 4, 24 l : 4 f• empered sE�1' Angler.''ti 3 tli„ t , ,1i �� l '•3 � a x � �� ,6 _ 4Y U „,x`� „� ,„ -fg1c, 1.fi+> -'Tl. �/ Glazin �,�'9�'.P}}' �� " Av rl '"' �, r1,s ° ^i s ? s .6-kg� • g � 'iA e. 'ifi .�: N '."W 4•*...)4 a 5 ` , .i'Y)}, Ye? " • "� ,w g f �i �.. .,.,Rlri...A • kfi _C L:\SueHemingway\Building.Permit.FORMS\Window Schedule.doc • O3 /0hn ./qr Pe umber .Q�'0 'C3ylh 2 9/-* REScheck Compliance Certificate Check By/Date/ Qinift'cE✓fir E New York State Energy Conservation Construction C de REScheckSoftware Version 3.5 Release lc Data filename: C:\Documents and Settings\Dan Ryan\My Documents\Hayes Construction Group\Drawings\Building Plans\Two-Story\Coldwater Creek\rescheck.rck TITLE: Coldwater Creek COUNTY: Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 12/12/03 DATE OF PLANS: 12/1/03 PROJECT INFORMATION: 774 Ridge Road COMPANY INFORMATION: Hayes Construction Group COMPLIANCE:Passes Maximum UA=506 Your Home UA=504 0.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1384 38.0 0.0 42 Ceiling 2: Cathedral Ceiling(no attic) 176 30.0 0.0 6 Wall 1:Wood Frame, 16"o.c. 1505 19.0 0.0 71 Window 2: Vinyl Frame:Double Pane with Low-E 175 0.410 72 Door 1: Glass 121 0.340 41 Door 2: Solid 20 0.140 3 Wall 2: Wood Frame, 16"o.c. 1595 19.0 0.0 83 Window 3: Vinyl Frame:Double Pane with Low-E 135 0.410 55 Door 3: Glass 80 0.340 27 Basement Wall 1: Solid Concrete or Masonry 1404 11.0 0.0 92 Wall height: 7.8' Depth below grade:6.5' Insulation depth: 7.8' Window 1:Vinyl Frame:Double Pane 7 0.380 3 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 286 30.0 0.0 9 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the i % r t New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment, such plans or specifications are in compliance with Code. s ' Builder/Designer I Date I Z) I J D3 4" �Na\E W. A? O 4,11 jPly)f- O,o �O o790-OFSS►O 1 REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE: 12/12/03 TITLE: Coldwater Creek Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry,7.8'ht/6.5'bg/7.8'insul, R-11.0 cavity insulation Comments: Windows: [ ] 1. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.410 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 2. Window 3: Vinyl Frame:Double Pane with Low-E,U-factor: 0.410 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 3. Window 1: Vinyl Frame:Double Pane,U-factor:0.380 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Glass,U-factor: 0.340 Comments: [ ] 2. Door 2: Solid,U-factor: 0.140 Comments: [ ] 3. Door 3: Glass,U-factor:0.340 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. . [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints, seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: I ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the I levels in Table 2. N. . Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)