Loading...
2011-318 glaki TOWN OF QUEENSBURY vpiw742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20110318 Date Issued: Friday, July 15, 2011 This is to certify that work requested to be done as shown by Permit Number P20110318 has been completed. Tax Map Number: 523400-290-010-0001-033-000-0000 Location: RIDGE Rd Owner: RAYMOND & LINDA BUCKLEY Applicant: JOSEPH EULIAN This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (---- avp4 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)FOr$1 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110318 Application Number: A20110318 Tax Map No: 523400-290-010-0001-033-000-0000 Permission is hereby granted to: JOSEPH EULIAN For property located at: RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RAYMOND &LINDA BUCKLEY Septic Alteration Residential 952 RIDGE Rd Total Value QUEENSBURY,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-318 septic alteration residential $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,June 30,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of eens �„ u June 30,2011 . ,,,4.4,- ' hi / ;,:‘ SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement lECEEIWEO Community Development Office - 11 JUN 28 201 Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 TOWN OF QUEENSBURY BUILDING S Office Use Only f i /�}-- � TAX MAP NO. 27 0 JO J-33 PERMIT NO. / PERMIT FEE /V APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: �f�S , 1 u. hCtP INSTALLER: r\ L ADDRESS: q5 1\.c1c t( cL Gilta,iAi ADDRESS: aZ ( i $e{ t C DU I A'l9 PHONE NOS. 6(F) �i 44—O0't HO E NOS. 7qq-Cfc4LOCATION OF INSTALLATION: 1 CR43*. f Q3 u(-i ) ee n��r j,1�, /&� �J RESIDENCE INFORMATION: NO.OF COMPUTATION YEAR BUILT X = TOTAL DAILY FLOW BEDROOMS (Gallons per bedroom) GARBAGE GRI R 1980 or older 3 X 150 = Z INSTALLED? ( `_ 1981 -1991 X 130 = SPA OR HOT TLAB 1992-present X 110 = INSTALLED? it JO PARCEL INFORMATION: / ✓ TOPOGRAPHY: FLAT ROLLING V STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM y CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? --" ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? -- ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is 15D ft) ✓ PERCOLATION TEST: RATE IS !:010 PER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: /000 GALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ,/ Li o° i IIABSORPTION FIELD(WITH NO.2 STONE) Total length IN IA. Each trench 61 X 50 ❑SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abidg by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sani.]ary S posal Ordinance. codes(a�queensbury.net � !�i VISIT OUR WEBSITE FOR MORE INFORMATION �tur of erson Sign Responsible Date www.queensbury.net .. / )-. - d-ell-- ___.______ Septic Inspection Report Se P P� Po t it- Office No. (518)761-8256 Date Inspectin request received: 7/I.J f) ._q__ Queensbury Building &Code Enforcement Arrive: cnc_/ amJpm 742 Bay Rd., Quee bury, NY 12800 4 Inspectotl's itials: NAME: 1 t PERMIT NO.: c "� LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil Type: nd/ Type of Water: Munici ell Wa r Waterline separation istance ft. Well separation distance ?_Z_ ft. Other wells: ft.Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench W --ft. Depth of trenches '2" ft. Size of Stone P' !/ Seepage Pits: Number _ Size: x Stone Size: Piping Sire Type Building to tank %)/L — Tank to Distribution Box rt, Distribution Box to Field/ Pit a Opening Sealed: _ N End Cap V Inlet/Outlet Pipes&Baffles V N C,-wRCr .14* ,,&/-77U.c) Manholes 12"or less below grade _Y!N 9 F;L-S [provide extension collar if Yes] Y N Location/ Separations L 1 c k —', Co.(' f/e-,-t- Foundation to tank t-KAI ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built _Y_N ETU Maintenance Contract _Y N provided Location of System on Property: Front Rear Left Side / Right Side Middle Front Middle Rear stem Use to : Approved Partial Approved s to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc Septic Inspection Report Office No. (518) 761-8256 Date Inspection uest received: Queensbury Building &Code Enforcement Arrive: am/p a art: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: (t e'�- /r�A PERMIT NO.: d LOCATION: I OCT /''/J INSPECT ON: 7 NAM RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A Absorption Field: Total length _ft. Length of each trench ft. Depth of trenches _ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field / Pit Opening Sealed: _Y N End Cap _N Inlet/Outlet Pipes &Baffles Y N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits _ft. Conforms as per Plot Plan —Y_ N Engineer Report and As-Built _Y_ N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S s t tus Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: 3't~' am/p�� part: am/pm 742 Bay Rd., Queensbu , NY 12804 Inspector's Initials: / NAME: Lul , PERMIT NO.: �G / ' /g LOCATION: INSPECT ON: 'L f RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal/Well Water _ Waterline separation distance ft. Well separation distance ft. Other wells: —m ft. Well Casing Length 50'+/- Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y N End Cap Y N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade Y N /� .1 [provide extension collar if Yes] Y N �U i o .- f`eoc►., Location/Separations ci/ hi..,... n� k.),- 1 s1Sk Foundation to tank ft. y,,, // .30 73e�c>`�►4 /r.C/ Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan —Y N Engineer Report and As-Built Y N ETU Maintenance Contract Y N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: ?:ZApproved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection FormssSepdc Inspection Report03 29 10.doc gik GIL- - A n L ,_. __. hp Seen or observed,or beliAve I saw PVI Pnr.P. '4r, '1 .111111111.1/0111,11): 'illii!lq1Mblii 0 ° 0 = 3 0 = (1). • (7) 0 c < ,.. ei,,-, r il cte.-.),r40.•... Pil6e4.°:5"4 •Sv7 --4 -0 4a. 3 07 M et^"v1.0.-""..Nt N vilifilp,‘„ , Cu 14 . 0 0 Y ‘bb lbs. in-1, '..., ypliA1' .---,--ro PRoc? cp II' 46-40 4 _ ci) ''‘ = -- Cl) o cr 7_00 _ - TOTAL ..,. m t-<s . 1 4 '0 z r xi 0 CD * 45.11F4, N- .-s stAuct: -.4 1 —{ .< • -.. N.) r- 00 c) Z _p. m . . , o.........b I t REAR PROPERTY LINE -V v‘ovt kool ktztc . ..._ i._ ....__ ozeiak I-7 btA l'aA cl 5V„ Ric/9e ol. au.eeiNsLarci i -I ibt si Uvvi'l ',,,, - :... ..;3:7,:,-J--,if; ,'•..,::.; ,„,! , n•-_'.'.-. -:' ,,-,,,i, - 4.. CENTER PROJECT SERVICES 73 Sheridan Street, Glens Falls, NY 12801 Phone-518-796-2515 December 8, 2010 Project# 133 Mr. Dave Hatin Town of Queensbury 842 Bay Road Queensbury,NY 12804 Re: Replacement Septic System - Eulian Residence—952 Ridge Road, Queensbury, NY Dear Dave: On October 16, 2010, I performed a percolation test at the Joe Eulian residence located at 952 Ridge Road in Queensbury. The test was performed to the southeast of the residence in the location where construction of a new leach field is proposed. The residence has an existing failing septic system which will be decommissioned upon completion and certification of the replacement system. The results of the testing are as follows: Percolation Test Stabilization percolation rate - 1" in 7 minute, 20 seconds The hole was presoaked and the test was run six times until it stabilized with three consecutive runs of 6:48, 7:05 and 7:20 respectively. The design flow for this 3 bedroom residence at 110 gpd per bedroom requires 471 sf of absorption area or 184 if of absorption trench. The new replacement absorption system for the proposed residence should consist of the new 1,000 septic tank located on the south side of the residence and a new distribution box with either a 20' wide by 25' long absorption bed (500 sf) with 4 - 20 foot long absorption laterals or 4— 50 ft long absorption trench lataerals either system will be located to the southeast of the residence. See typical detail sheet for typical system installation details Please call me if you have any questions. Sincerely, Thomas R. Center, PE Cc: Joe Eulian RECOMMEND ALL ACCESS eENCRETE Got STOW m°�N1N°seaRIM ADM ALL ow MA°0 MPROMMATE�,GRAM FNIMiI oRAOE 1r MAx BARIIEe MATEIAL INSTALLATION OF DISPOSAL FIELDS Li 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING, INLET BAF11E 'AI"Lcst i� r MRN DDEDPARTMMEENT�OFNHEALACLTH INDIVIDUALLLHOOUUS"EHO N.Y.S. SYSTEMS, AND DISTRIBUTION emc ASTM F481-76 INSTALLATION OF THERMOPLASTIC PIPE AND Y FORT MRUEe OR r .gym 'RATED PCumRAL. CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. SLOPE 1/Ir-t/az'PER Ft MpL SLOPE 2. NO HEAVY EQUIP� THE SHALL BE ALLOWED WITHIN LIMITS LgR10 LEVELP FOpT 0 a 1' OD OF ALL OIS1RRBu1OR PIPES MUST OF THE DISPOSAL FIELDS AFTER PITALLATION HAS BEGUN. t/'r Put FOOT PLUOGED UNLESS NTEROOME1CIED PE NiS 1A ALL OUILET INVERTS ALL LATER"70 eE OF EAUAL LENGTH. 3. AFTER EXCAVATION Z• WIDE TRENCH TOE DEPTHS REQUIRED, SEPTIC T -KET t OU11w f SANE THE WALLS AND FLOOR OF EACH TRENCH SHOULD BE CLEANED BY FORT E°R A STANDARD ABSORPTION TRENCH PROFILE SECTIONS ACHIEVES SURFACE AND TO LOOSEN DISTRIBUTION Box AZ)w mum wra 4. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND UNTREATED BUILDING PAPER ALL, BE EXEER SEED TO AVON) INCLL SHALL ISIO) OFF 0 GRAINEDSOI AS SHWIN AND CARE ILLS AND MINIMUM 2K wM 7REHCH BACI LL SHALL CONTAIN2'-0" t'-0" 2'-0r' ts71 OTHER'WASTE MATERIAL IN THE STONE AND PIPE NO soups LARGER THAN CEOs SLOPE 5. THE PIPE SHOULD BE LAN) ATE GRADES AND TO THE 3 1KXyE5 IN DIAMETER OVERF7l1 TO SOW ON SLOPED SITES RELATIONSHIPS SHOWN ON THIS DRAWING. MAINTAINING STRAIGHT PROVIDE r SAID OR SEPTIC TANK FOR SETTELMENT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS PEA MAVEL UNDER TANK_ N Ts OR OTHER UNSUITABLE CONDITIONS. E PIPE SHALL BE LAID WITH E HOLES DOWN IN ALL CASES BARRIER MATERIAL 70 BE 6. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL SEPTIC TANKS } B" - tz" � �t� � AND M DIVERT FROM E DISPOSAL ACEFIEL RUNOFF FROM ADJACENT AREAS AWAY 1.ALL UNITS DIAL COMPLY KITH THE REQUIREMENTS OF THE NEW YORK 3 STATE DEPARTMENT Or HEALTH AND SWL BE PRECAST CONCRETE A r MIN. 4' A� 7. REMOVE LEAVES, ROOTS, PLANTS AND ORGANIC DEBRIS PLOW SURFACE PRIOR AS MATRUCTU ES BY FORT PLACED O I EaCOMP NT � 18r" MI. LATERAL TO SPREADING FILL MATERIAL. z ALL STRUCTURES To BE PLAOEO a F>AM.COMPACT SAND OR aIAYF] FOUNDATION DIEIEYER ET051110 FOUNDATION CONDITIONS �o ARE uN1uTABUZ CINJSED y�O SQL K PLED AS 3/4 TO t //2' 8. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION FIELD AREA NECESSARY W ACHIEVE A STAKE FO1NDAIM W-O.. WA ED CRUSHED STONE J.SEPTIC TANKS NSTAUM NI TRAFFIC AREAS SHALL BE EXTRA HEAVY 024- N. 9. PLACE FILL AND ALLOW TS ANDARDSTABILI E IN ACCORDANCE WITH NEW WORK STATE COHSTRUCION DESIGNED FOR H-20 1MEEtDEPARTMENT OF HEALTH STANDARDSMAXIMUM SEASONAL HIGH GROUNDWATER IMPERVIOUS SON. OR BEDROCK = STANDARD PIPE ABSORPTION TRENCH SECTION SWALE AT UPHILL SIDE �— 1dM10'0"'t INSTALLATION OF DISPOSAL FIELDS OF BED TO DRAIN RUNOFF AWAY FROM BED SLOPED TO DRAIN 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING. AND SHALL BE IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS, AND a EARTH ASTM F481-76 INSTALLATION OF THERMOPLASTIC PIPE AND 6" TO 12" BACKFILL FILL FlL,TER FAENiIC CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. �y OR GE07EXTILE 2. OF E DISNO HEAVY PQUIPMENT SHALL BE OSAL FIELDS AFTER PIPE INSTALLATION HAS WITHIN THE ITS BEGUN. 2' MIN. 4" ATERALPERFORATED 3. AFTER EXCAVATION OF BED TO THE DEPTHS REQUIRED. LATERAL 6' MIN. AND RAKED WALLS AND FLOOR OF EACH SIDE WALL SHOULD BE CLEANED BULDM 3//4 TO 1 1/2 ED TO ACHIEVE AN EVEN SURFACE AND TO LOOSEN CRUSHED STONE SMEARED SECTIONS OF TRENCH. 2'-6" :i-0' 5'-0' 5'-0' SEPTIC TAM(AT LEI�ST m►a 24 MIN. 4. PLACEMENT OF THE PERFORATED PIPE SHALL BE AS SHOMM. BW FROM WELL MD 10r I&-0' MA�M�y _ THE PIPE SHOULD BE LAID AT THE GRADES AND TO THE FROM HOUSEAMICP.UJE 20'—O' BASEMENT WALL GRWNDWA M = TIGHT JOINT 40 4 PVC P� MN. ELEVATION = RELATIONSHIPS SHOWN ON THIS DRAWING, MAINTAINING STRAIGHT ON SLOPE OF 1tir M. SET: >E s CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS T� �iTANDARD ABSORPTION BED SECTION OR OTHER UNSUITABLE CONDITIONS. oRSTweuTION BOX GRADE t/e'fir. - N.T.S. t.No1E 4 5. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL 1Nr p�y AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY SE NOTE s 10'NN. PROLIE 12' M III, �1R= II — FROM THE DISPOSAL FIELD. SEE NOTE I 6" MIN. 6. REMOVE LEAVES, ROOTS, PLANTS AND ORGANIC DEBRIS. PLOW SURFACE PRIOR TO SPREADING FILL MATERIAL SAGE DISPOSAL LAYOUT J_ INTERCONNECT ENDS NOTE, 6" MIN' BOTT01A OF BED a PERFORATED PVC OF LATERALS 7. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION FIELD 1. 11E FIELD TO BE 1001 OR MORE FROM ANY 1— LATERAL, LAID LEVEL AREA. LANE.SNAMP,DITCH OR WATERCOURSE AND 1W & NO PART OF THE DISPOSAL FIELD SHALL BE INSTALLED UNDER OR MORE FROM ANY WATER LINE UNDER PRESSURE OR 111-Qt0U1D POI. DRIVEWAYS. z FOR SE01AM E SETWEEN HOUSE`AND DISTRIBUTION BOX �Q tD ABSORPTION BED PROFILE PP USE DUCW OR CAW LION PIPE.OR SCHEDULE 40 PVC 1MTH OEIENTED JORM 3 DISCHARGE FoanK ROOF AM CELLAR DRAINAGE EULIAN STANDARD SEPTIC SYSTEM AWAY FROM SEVI RAGE SYSTEM. CENTER PROJECT SERVICES 4. DISPOSAL OSAL FELD S«a BE CONSTRUCTED PARALEL 73 SHERIDAN STREET 952 RIDGE ROAD DETAILS ■TH CONTOUR uEs FOR RAISED ABSORPTION TRENCH SYSTEMS HORIZONTAL SEPARATIONGLEN> FALLS, NY QUEENSBURY NY DISTANCES SOIL BE MEASURED FROM THE EDGE OF THE ILL 108 #133 BCAIX: NOT TO TWCAIX 1103: 12/00/10