Loading...
98-364 BUILDING PERMIT VALUE $ 0 TOWN OF QUEENSBURY No. 98364 TAX MAP NO. 39 . —1-45 . 1 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to LEDFORD, JANET M. OWNER of property located at ASH DR. Street,Road or Ave. in the Town of Oueensbury,To Construct or place a SEPTIC ALTERATION at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is ROCK CITY RD. HUDSON FALLS, NY 12839 2. CONTRACTOR or BUILDERS Name CONDON SEPTIC & DRAIN SERVICE 3. CONTRACTOR or BUILDERS Address 4. ARCHITECTS Name 5. ARCHITECTS Address 6. TYPE of Construction—(Please indicate by X) SEPTIC ( )Wood Frame ( )Masonry ( )Steel 1 1 7. PLANS and Specifications No. 8. Proposed Use SEPTIC ALTERATION 25 July 1 2000 $ PERMIT FEE PAID —THIS PERMIT EXPIRES 19 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) 1 July 1998 Dated at the Town of Queensbury this Day of 19 ( SIGNED BY for the Town of Queensbury Building and Zoning Inspect ir ` a1 1 11�(l. L',/.i wA. #iJl l it/ M A. - \!A./A. yyJ A. Li\1♦11 1 . r Town of Queensbury Dept. of Community Development Permit No. ----C Building & Codes Office DJUL. 01 742 Bay Road t Fee Paid $ 199p Queensbury, NY 12804 L Location of property for installation: 9-4 Ayr}- P19-1 V-€, Property Owner's Name: ,I. til j- LE n PO 4.,5> Property Owner's Mailing Address: 120G1C C-1-Y $4-17 Installer's Name: 12 Ale._ G k.,) , 12E. Phone # 7c1 g 51140 Z_ Number of bedrooms (if residential): 4 Total daily flow: bob (residential - compute @ 150 gal./bdrm.) Topography: flat, t4olling, steep slope % of slope Soil Nature: Viand, loam, clay, other / depth: Ground water: at what depth? feet / Bedrock or Impervious Material: at what depth? — feet Percolation test: not required, required [ rate min.. per inch ] Domestic water supply: municipal, V well, other CL e,xi 1 4.1Lt If domestic water supply is a WELL, water supply from any septic absorption is feet. PROPOSED SYSTEM Septic tank:/5bgallon (minimum size: 1,000 gal.) Tile field: each trench feet / Total system length: feet Seepage pit(s): number of 1 ST- / size each: ft. by ft. Size of stone to be used: # / depth or thickness feet HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gallons Alarm system and associated electrical work to be inspected by a certified agency. J For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to e by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.Signature of responsible person: Date: Id �e 9 O. TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name L-,14.. Location r4C%/ Date /34ieniiit # 0'A44 SOIL TYPE: Sand-Loam-Clay- Results of Percolation Test- (if applicable) Rate-Minute/Inch TYPE OF SYSTEM: ABSORPTI FIELD: Total th Length o each trenc Depth of tr ches Size of stone SEEPAGE PITS: umber- Size - ft. x ft. Stone size _ PIPING: Size Type Bldg. Tank Tank o Dist. Box Dist. Box to Field/Pit Openings Sealed? Yes No Partial LOCATION/SEPARATIONS: Foundation to Tank feet Foundation to Absorption _ feet Separation o Pits feet Conforms as per Plot Plan Yes No LOCATION OF SYSTEM ON PROPERTY: (circle one) Front - Rear - Left Side - Right Side Middle Front - Middle Rear COMMENTS: SYSTEM USE APPROVED: 4/0 NO Arrived: /Pi Departed: <# Building Inspector • S,, p��\� /-' �‘ GARAGE P EXISTING SEPTIC TANK ,�/ `‘ NEW 1500 GAL. SEPTIC TANK / (4 BEDROOMS) \ �� COTTAGE #1 APPROX. LOCATION 1 i , OF SEPTIC MANHOLE �1 � li. COVER. 11"• , COTTAGE #2 ,\ 1 ``�, ,4 `O� Oa ` /� \APPROX. WELL ,� ,t 1�,0. POINT LOCATION / APPROX. LOCATION OF .) DISTRIBUTION VALVE BOX 1111 119—� \ TO BE ABANDONED 1 VENT TO EXTERIOR kt12"0 PVC WITH * `` CHECK VALVE ATSEPTIC TANK 3 APARTMENTS \ \ NEW SEWAGE EJECTOR PUMP ' / \ LOCATION ‘ (SEWAGE PUMP WS0511BF t MODEL 3887, 1/3 HP, 115V, 2" SOLIDS HANDLING; 24" DIAMETER BASIN; A2-5 115V MECHANICAL SWITCH; 24" SIMPLEX COVER, AS MANUFACTURED BY GOULDS PUMPS, INC.) GLEN LAKE APPROXIMATE PLO k RLAtt 1"=50'-0" TAX MAP # 39-8-45.1 RONALD RICHARD RUCINSKI DATE: 30 JUNE 1998 ARCHITECTURE LEDF9LDASAHPADENTS RTM 827 MAPLE AVENUE '°.;" SARATOGA SPRINGS, N.Y. 12888 1� ;,�// RIVE VOCE 518-580-1905 fib %�' / QUEENSBURY, NY FAX 518-584-5012 0 i/ E—MMt. ruolnakNlcapitaLnet _ G�AS,�%j /%/ 01997 AV /�/i/ R IS A VIOLATION CF THE LAW FOR ANY PERSON.UNLESS � ` ,, �i/ / TO AUER ZANY 1EM OR OF THIS DOCUMENT IACING UNDER TIE DIRECTION OF A UCENSED N ANY WAY //�//// / r fl _ Goulds - . a Submersible Sewage Pump fill MODEL ,r.0,,..,, ,...„i,(11 3887 ...„,. , APPLICATIONS Three phase: FEATURES •Motor:Fully submerged in Specifically designed for the •''A—1 HP,200/230/460 V, high grade turbine oil for P Y g •Impeller:Cast iron,semi- 60 uses: 60 Hz, RPM; HPlubrication and efficient heat •Homes 200/230/460 V,60 Hz, open, non-clog with pump out transfer. Designed for vanes for mechanical seal •Sewage systems 3500 RPM. continuous operation.All •Dewatering •Overload protection must be Protection. Balanced for ratings are within the working provided in starter unit. smooth operation.Silicon limits of the motor. •Water transfer bronze impeller available as Anywhere waste or drainage •Shaft:threaded 400 series an option. •Bearings:Upper and lower 9 stainless steel. heavy duty ball bearings must be disposed of quickly, •Bearings:ball bearings— •Casing:Cast iron volute quietly and efficiently. upper and lower. type for maximum efficiency. construction. •Power cord:20 foot Adaptable for slide rail •Power Cable:Severe duty SPECIFICATIONS standard (optional lengths systems. rated,oil and water resistant. available). ■Mechanical Seal:SILICON Epoxy seal on motor end Pump Single phase: CARBIDE VS.SILICON provides secondary moisture •Solids handling capabilities:0 •Y3 and'A HP—16/3 SJTO CARBIDE sealing faces, barrier in case of outer jacket 2"maximum. with 115 V or 230 V three stainless steel metal parts, damage and to prevent oil • •Capacities: up to 180 GPM. wicking. prong plug. BUNA-N elastomers. •Total heads:up to 49 feet •3/4-1 HP—14/3 STO •0-ring:Assures positive TDH. •Shaft:Corrosion resistant with bare leads. sealing against contaminants •Discharge size:flanged— stainless steel.Threaded Three phase: and oil leakage. BF or BHF units have 2"NPT .�'/z-1 HP—14/4 STO with design. Locknut on'three threaded companion flange phase models to guard ■Fasteners:All Stainless Steel as standard.Optional 3" bare leads.On CSA listed against component damage NPT threaded companion models—20 foot length on accidental reverse rotation. AGENCY LISTINGS flange available and must be •SJTW or STW are standard. ordered separately. (Order Class B insulation. SP Canadian Standards Association No.Al-3). •Mechanical seal:silicon ® Underwriters Laboratories carbide rotary/silicon METERS FEET carbide stationary,300 .1_. __ _ ___. .. SERIES:3887 series stainless steel metal 15- 50 4 SIZE:2"SOLIDS parts, BUNA-N elastomers. ...li—► 2'i SGPM RPM:VARIES •Temperature: r 104°F(40°C)continuous c 40 ��® �'� — 140°F(60°C)intermittent> •Fasteners:300 series � 10- liajiltjrlitrirallgIIIIIIIIIIIIIII stainless steel. a30•Capable of running dry o —= , 1' 1®®' without damage to 4 4.42t:1111111111111111111111k1 components. o 0� ai�'i �1iiiilliki 4 Motor 5- Flit III I Single phase: __ __-- ._._._.. •'/3—'/z HP,115 V,200 V,or 10 "rug! � 0 230 V,60 Hz,1750 RPM 3/4 I1___ _ .._ -.®l 1_ -1 HP,200 V,or 230 V,60 j ` I ! i` Hz, 1750 RPM;1 HP,230 V, 0- Oo 20 40 60 80 100 120 140 160 U.S.GPM 60 Hz,3500 RPM, •Built-in overload with o io 20 30 4.0 m'/h automatic reset. FLOW RATE ©1995 Goulds Pumps,Inc. Effective May,1995 17 83887 (aul_ilft; 111 Effluent and Sewage STANDARD Sewage Basins and Covers N • 18"and 24" 30"and 36" SIMPLEX DUPLEX BASINS FEATURES F G Approx. Design Model A B C D E No. Size of No. Total Gal. •18"and 24"basins are No. of Hub& of Insert Bolt Cap. WI Per polyethylene design for light Hubs Material Inserts Size Circle Gals. Lbs. Inch weight and superior strength. simplex - 1S 18" 30' 21. '/��e 1 4"-Rubber 8 '/. OO •30"and 36"basins are A7-2401 24" 36" 30' 1e — 1 4"-C.I. 6 %-16NC 26% 60 35 1.97 heavy duty fiberglass Duplex A7-3002 '30% 36" ''7,e` 1 4'-C.I. 16NC 32% 140 construction. A7-3602 36' 36" 40' 5/,e 12" 2 4"-C.I. 6 %16NC 38% 158 85 4.38 •18"basins are supplied with one 4"rubber inlet hub c�I for field installation. 45°� "G�'INSERTS VW EQUALLY A •24"basins are supplied �;;� SPACED ,�— —�'_-� with one 4"C.I.inlet hub for field installation. pre-drilled `` D - 1 HUBS E •30"Basins are t and include one 4"C.I.inlet - 0 - e hub for field installation.■36"Basins have 2,4"C.I. inlet hubs pre-installed at the ��Allpfli " I I factory. COVERS (for above basins only) . FEATURES •Heavy duty steel - construction. DUPLEX SIMPLEX ■Available with either 2"or 3" SPLIT COVER 18" 30"and 36" flanged discharge and vent. 24"ONE-PIECE •Pump access plates are provided on 30"and 36" Gage or Discharge Electrical Outlet diameter covers to simplify Design Model No. O.D. Thickness Fitting Vent Hole Dia.* pump removal. 18"diameter A8-1822 20'/i 10 2" 2" 21/2' has split cover which allows A8-1833 20'/x' 10 3" 3' 2%" removal of pump and controls without disturbing the vent Simplex A8-2422S 28" '/i 2" 2' Single pipe. •24"cover is one-piece A8-2433S 28' 1/4. 3' 3" Single simplex design. A8-3022D 34' '/ 2" 2' 21/2' •Gasketed design locks One Per Pump offensive odors in basin. • A8-3033D 34' ''A 3" 3" 2%" • One Per Pump2 Discharge flange(s),vent Duplex , . flange,cord seal,gasket,o- A8-3622D 40' 'A" 2' 2' One Per Pump 0 rings and fasteners are , ' included. A8-3633D 40' '/i 3' 3' 2h One Per Pump "Cord seal provided. GOULDS PUMPS. INC. WATER TECHNOLOGIES GROUP SB'ECA FALLS NEW YOI (DI48 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. PRINTED IN U.S.A. 48 i • . Goulds Pump Switches C 1 41.-0 ... "10 , A2-91 ■PVC plastic float housing A2-11 and A2-12 ■A2-4:15 foot power cord can be used in liquids up to Features equipped with piggy-back ;' Features 140°F(60°C). plug NEMA 6-15. ■Mechanically activated tilt ■Automatic operation •■Double float switch ■Cast iron body with switch with heavy duty non- directly controlled by pump. consisting of two sealed stainless steel strain relief, mercury contacts,not (No control panel required.) floats,two cables molded to fasteners and bracket. sensitive to rotation. one piggy-back plug cord. ■Ideal when limited space is ■Rated for up to' HP, •■UL and CSA listed. ■ •Both sealed floats contain a available. =x 115 V,single phase within Specifications heavy-duty mechanical switch p • amp rating below. ■15 foot Neoprene flexible with a holding relay sealed -I •Normally open design. 14 gauge 2 conductor (UL) inside one float. •Adjustable start/stop range SJOW-A,SJOW(CSA)water ■A2-11 is rated for up to • from 5.5"to 36". resistant cord with piggy- %HP, 115 V.A2-12 is rated •Non-corrosive PVC plastic back plug NEMA 5-15. for up to 2 HP,230 V,within ID ;- housing for use in liquids up ■Rated for 85 start up amps, amp rating below. to 140°F(60°C). 115 V,15 running amps. ■Adjustable start/stop range 4 ; •Automatic operation by ■Not sensitive to turbulence. from 1"to 48". SJE ‘J). io 1 directly controlling pump. A2-6 •Automatic operation by ;' (No control panel required.) directly controlling pump. (No SJE •UL and CSA listed. Features control panel required) •The SJE VerticalMasterTM Specifications •Mechanically activated tilt ■UL and CSA listed. pump switch is designed to •10 foot Neoprene flexible switch with heavy duty non- Specifications operate in applications with 16 gauge 2 conductor(UL) mercury contacts, not ■15 foot Neoprene flexible limited space,such as small (UL)SJOW n (CSA)to rotation. 14 gauge SJOW-A,SJOW(GSA)cord ( ) sump chambers and laundry • with molded piggy-back plug ■Rated for up to 2 HP,230 water resistant cord from trays,as well as in large �`. NEMA 5-15 P. V,single phase operation, float to splice.14 gauge 3 tanks.This pump switch is ■Rated for:85 startup within amp rating below. conductor(UL)SJTOW-A. capable of directly controlling amps,13 running amps ■Normally open design for SJTW(CSA)thermoplastic pumps up to t/2 HP at 120 V maximum. pump down operation. water resistant cord with and 1 HP at 230 V.The SJE • •Not sensitive to turbulence. •Adjustable start/stop level molded piggy-back plug. VerticalMasterTM is designed from 5.5"to 36". ■Rated for 85 start up amps, for easy attachment and is A2-9F ■Epoxy sealed switch and 115 V, 15 running amps available in pump down cord conductors. maximum.85 start up amps, models only. ■Same as A2-91,except with ■PVC plastic float housing 230 V, 15 running amps 20 foot cord. be used in liquids up to Features can F(60°C . maximum. ■Magnetically activated. 140° A2-5 ) ■Not sensitive to turbulence. ■Heavy duty contacts. -features ■Automatic operation direct) controlled •by pump. A2-1/A2-4 ■Adjustable pumping range I. •Mechanically activated No controlpanel required.) of 3 to 6%2 inches. tilt switch with heavy duty ( ■Pressure actuated switch. ■Not sensitive to turbulence. •UL and CSA listed. ■ • Liquid level differential ■Available in pumpdown non-mercury contacts,not Specifications permanently set at 6. models only. sensitive to rotation. •Rated for up to 3 HP,115 •15 foot Neoprene flexible Requires 12"submergence. a UL listed for water and 14 gauge 2 conductor (UL) ■A2-1: rated for up to%HP, sewage and CSA certified. V,single phase operation, within ampratingbelow. SJOW-A,SJOW(CSA)water 115 V,single phase. resistant cord with piggy- A2-1:15 foot power cord Model Description / ■Normally open design for 10VM1WP 10ftcordwithplug-115V , J um down operation. back plug NEMA 6-15. equipped with piggy-back pump p ■Rated for 85 startup amps, plug NEMA 5-15. 1OVM2WP ioft cord with plug—230V •Adjustable start/stop level • from 230 V,15 running amps. ■A2.4: rated for up to%HP, 20VM1WP 20ft.cord with plug—115V •Epoxxyy to 36".sealed switch and ■Not sensitive to turbulence. 208/230 V,single phase. 20VM2WP 20 ft.cord with plug—230 V cord conductors. ©1995 Goulds Pumps,Inc. Effective May,1995 31 BSWITCH