2002-938 A TOWN OFQUEENSBURY Fors A ,1�r 1 N 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20020938 Date Issued: Friday, August 15, 2003 This is to certify that work requested to be done as shown by Permit Number P20020938 has been completed. Tax Map Number: 523400-289-017-0001-011-000-0000 Location: 84 ASH Dr Owner: SUZANNE KING HUNSICKER Applicant: SUZANNE KING HUNSICKER This structure may be occupied as a: By Order of Town Board Septic Alteration Residential TOWN OF QUEENSBURY (... eW/P 4 «\ Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020938 Application Number: A20020938 Tax Map No: 523400-289-017-0001-011-000-0000 Permission is hereby granted to: ST JZANNE KING HI JNSICKER For property located at: 84 ASH Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SUZANNE KING HUNSICKER 60 STATE RTE 149 Septic Alteration Residential Total Value LAKE GEORGE,NY 12845 Contractor or Builder's Name /Address Electrical Inspection Agency CUTTING EDGE GROTJP_ 1,1,C NY 12804-0000 Plans&Specifications 2002-938 Residential septic alteration per plot plan and specifications. $25.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, November 12,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To Queens ry; ay,November 12,2002 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Application for Permit—Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: Office Use Location of installation: $4 As Dr• (,t jam, /n„ i Ail I File Permit No. L -"-- / ✓, Tax Map No.281. 17 / / i1 .�. '/• Owner's Name: -T'.� g See ILNs:glu-<^ Fes Paid Address: 430 St e4 149 L411. Crea7- Aly lzgfr --?q Ss I ar\AD 2. INSTALLER'S NAME CNW e (T1'6ap , LLC PHONE NO. 718 -'�� 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply# of bedrooms with applicable gallons per bedroom to equal total daily floo � Year of House: No. of Bedrooms x Computation = Total Daily Flow v ED 1980 or older x 150 gal/bdrm = NO v () 8 2002 1980—1991 x 130 gal/bdrm = TOWN OF 1991 —present (o x 110 gal/bdrm = CEa() BUILDING UEFNSB�RY See A144 1 Lem Jell jy sJer• Nfrbe5 ANO CODE Garbage Grinder Installed yes / no Spa or Whirlpool Installed yes / no 7 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) Flat osz C raphv an oil Nature Groundatwhat Wdepthater Bedrockatwh ort d Imperviousepth Material Domeisticpal Water Supply g munic Rolling loam )Zo feet ' : NIA feet EC> Steep slope clay well; water supply < 4 %slope other from any septic-system depth: 7 S' absorption is too ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: 4s SZt Allitu to per inch 5. PROPOSED SYSTEM: For Nev Constni ti9n: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 2 0 gallon (min. size 1,000 gal.) Tile Field: each trench fl. Total System Length: fir Seepage Pit(s): number of size of each: ft by ft. Size of Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 80 LF 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signa ure o responsi e person D e • • ',- 'Town of ( ueettwltury Sewers a nt1 Scwnp,e Disposal (:Ita Viet- i\ipitmlix t• •. AWit)It1''1'1ON IN'111;1,1.) • SE PA 1tA'I'1QN ItE(11.1i Iti.1\1 I'.N'I'S ` „/„,..-----------"‘--.6 1..� !7111sjet POND it WELL D4 liAtelk. \, - •IK}ur CA51.1r; -... • - 1. ., l -A. i - ►busE G ( , ,� ,110' llous1= G Ecc:7:-. ci - t P.IY i%.`,1V,`" \1 ...._�*� � r ��,�.. 1-ur,Ittleoa it,91 I] \ . C1f,tl i f'111.t.b • ...L. - 17411•b +ram_ - 7. SIGNATURE &INFORMATION FOR R1.SVONausi. rn1;\.D.,r,, ww,...+..,...., Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: yi am/ m Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: �'- NAME: i rh ^-,c%- PERMIT NO.: 5.3(1' LOCATION: cr y� r J INSPECT ON: ��o RECHECK: Comments and/or diagram Soil Type: n 1`Loam/Clay Type of Water: Municipal/ ell Wate Waterline separation distance ft. Well separation distance /(o ft. Other wells: /t, ft. Absorption Field: Total length J 2,0 ft. Length of each trench J(� ft. Depth of trenches _ Z.- ft. Size of Stone Seepage Pits: Number Size: x Stone Size: • Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit 4/4 f Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front Rea Left Side 'ight Si:- Middle Front Middle Rear System Use Status: }(J Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:'\.SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 s L II 7 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: it 36 am/pm Depart: arn/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ¶fr NAME: t;\tr rk`mil c. PERMIT NO.: C 9 '- 3 LOCATION: ISy INSPECT ON: 7 / l '.3 RECHECK: / Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. 5-0,Ate/_ dir4(')/`) 7� Size of Stone Seepage Pits: Number rL 'rcr)M -fy l Size: x '7 Stone Size: hi)//1" AAjb Piping Size Type occroZ 0.66/ S IL Building to tank _ Tank to Distribution Box /J ‘06erlie Distribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan _Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office 7 Disapproved L:'\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 Septic Inspection Report Office No. (518)761-8256 Date Insp ction request received: Queensbury Building& Code Enforcement Arrive: P.2A( am/ m Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: 1M `s '\c- }C)S PERMIT NO.: 0 0-c J C� LOCATION: "T INSPECT ON: RECHECK: -�j Comments and/or diagram Soil Type. a�S /Loam/Clay Type of Water: Municipal/ke11 Wa Waterline separation distance i,. ft. Well separation distance `j ft. Other wells: _ f ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. i ` s" Size of Stone LI / Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box 4.e S'f)/L Distribution Box Field/Pit if* 10k Opening Sealed N/Partial � ;$ e J fete ler) v Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y_N Location of System on Property: Front Re.' Left Side •ight Sid Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 A A BAFFLE INLIrET 4' TOPSOIL — - - - — _ i 4' 0 PERF. PVC PIPE OF ,y 9L GEOTEXTILE COVER HOLES POSITIONED 10'-17' _ �S F OUTLETGROUT UNUSEDOOPENINGS AT 5 & 7 O'CLOCK 30' MAX. � BINDING STRAPS PO2 1 165 92� ELJEN INDRAIN UNIT , PLAN VIEW -7� TPl 0� CONCRETE SAND 6 N �� 3 4' MIN UNDISTURBED SOIL �C DRA AGE GRADIANT — 4' _ CAPP X. 4%) MIN, 12' COVER 2' MIN. TO IMPERVIOUS LAYER O HIGH GROUNDWATER LEVEL ' f2 _ _ X T LEACH IELD _.._.._.._.._.._.._.._.._... EISI L XISTING 2000 GAL SEPTIC TANK INLET, 4' SCH 40 OUTLET, 4' SDR35 PVC PVC MN. SLOPE #'/FT O O MIN. SLOPE J'/FT MIN, 9' CRUSHED STONE t/� f WELL tr • �� � SECTION A—A YC CELJ[E�] 0HO � ° M 711M. ]C H C ROO20 2 C 70 [� , vL yG NOT TO SCALE NOT TO SCAL a WELL • WELL s52 3'-6' GLEN LA E 2'-6' L IX .837 NCB 8 TE PLAN �C AL E 1 °° 4 0' LIMITS OF LEACH FIELD EXCAVATI❑Nit j I LANDS OF DERBY/STEIN _ 4' MIN, OF UNDISTURBED SOILS BETWEEN TRENCH WALLS j INLET OUTLET WELL } END CAPS (TYP.) j I. I 4' DIA. PERF. PVC PIPE / WATER WELL INFLUENCE SLOPEi J'-�'/FT LINES (100' RADIUS) t PLAN VIEW L>J / ±2S 1 • � � 24' MANHOLE FRAME AND GRATE. __ - _. __ _ r- � ,� (NEENAH 1754 OR EQUAL) I _ L� FINISH GRADE EXISTING 2000 GAL SEPTIC TANK LL l.,_ / PROPOSED �LTERING MANHOLE ry PAVED DRIVEWAY / -'/ (� Co O W Q / PROPOSED ELJE INDRAIN - v CATCH LEACH FIELD/ 0i P 1 �DDRAIINAGZ ZABEL FILTER MODEL A-100 4' SCH 40 PVC GRADIAIJT LLJ W W 4 SCH40 (APPROX. 4%) LANDS OF HU SICKER Z Z Z FROM SEPTIC TANK DISTRIBUT (MIN SLOPE J'/FT) (MIN SLOP � PR❑P❑SED DISTRIBUTION BOX J J J TP1 Z Z z / LLJ W LL MIN 9' CRUSHED STONE WOOD FENCE ±240 10' SETBACI: LINE DISTRIBUTI❑N BOX SECTI❑N VIEW 4' SCH40 PVC FROM SEPTIC TANK I c e e o e a_ LEL�JEH PHRO H LFAGa FE LDD PLM LANDS ❑F GRAVES WELL N DSCALEFOL1�ITERRHO CMIQLI�N LI�C TOWN or QUEEN l�RY NOT TO SC pG�30pOSED S0TE PLAN SCALE: �I °° 1 s p�'. Construction Notes: Leach Field System Notes: 9. Contractor to verity all utility locations and contact UFPO prior to any Flows: 6 bedroom residence, all lum in fixtures have been have scram .r ` or 'eve I say evidence of, RECEIVED 1. Sewerage o s. op g I 1. Sawcut and remove paved areas as necessary to install new leach field excavation. ss i;ooe;, 11s, frees, fence °to system, structures and piping as shown on the drawings. No paving will modified to low flow units to reduce daily design flows. As per 1 ONYCRR ail, ehiect „ 10.Contractor must at all times allow access to the driveway for occupants. Appendix 75-A, daily design flow per bedroom = 110 gal/day. sl,,wri on t;i1� �:_';,��ir,ent. I also represent that I have r NOV 0 8 2002 � (ibe placed over the new leach field system, this area to receive 4 topsoil, - k ;a;ed the iStances set forth on the diagram.MTE �Oo C�Q��ON UVUG�1Lf seed, and mulch. All other disturbed paved areas to be replaced in kind. 11.Construction fencing shall be provided and maintained throughout (6 bedrooms x 110 gal/day) = 660 gal/day personal TOWN OF QUEENSBURY construction. �! 8 �- BUILDING AND CODE _ 2. Existing 2000 gal. septic tank to be utilized, remove existing outlet piping 2. Septic Tank: 1.5 x design flow = 1.5 660 = 990 gal „ ATE 12.Survey and site information taken from previously completed site plans = !n ? ;"" +: AffaondackPark M1 and replace with 4 SCH 40 PVC C /< /ft to filtering manhole. Y P Y p P Minimum required tank capacity 1000 gal �Jllt developed b VanDusen and Steves Land Surveyors, Glens Falls, NY ' P Y Y Existing 2000 gal tank is acceptable for reuse. --•----- , 3. Install filtering manhole as shown Dn the contract drawings. Install SCH • � ,, t ,I �f ',• r` : .�? , ;, , (Sept 15, 1997). Limited measurements were taken for plan preparation • V. r " x u! 40 PVC pipe between filtering manhole and new distribution box @ / /ft 3. Leach Field Design Criteria: As per ELJEN Corporation Design and 1 R by CEG. Contractor to verify all measurements :`. slope. Installation Manual for NY and in accordance with 1 ONYCRR Appendix ,,, Percolation T � a 4. Erosion Control shall be maintained throughout the duration ofTest Results. — 75-A, the minimum trench length is 79 LF. This is based on a percolation 'onl - 1 , Qa construction and shall be in accordance with the New York Guidelines for rate of 1-5 minutes per inch for modified site soil conditions. Indrain units TWOTHYAND SUZANNE Urban Erosion and Sediment ContrDL Minimum are available in 4' lengths, so use 80 LF. There should be a minimum of , . P• e A�,o�, t u,,3,, : . ", :,, No. Perc. Rate Depth o _ 4 of existin undisturbed soils between each trench. Trench len the are o 0 0 0 x ( LakeGe6fw NY,,26�5 ,;� 5. All work to conform to all local, state, and federal regulations. g g d d D d 0 o a s, 1 1 follows II w for proper setback and well influence separation 84 ASH Dtl §V (MAID QD9 289. 17I 1l 1 �1) �� PT1 45 sec./in. 36 as to allow p p p F N , tl 6. Septic tank to be pumped clean prior to and during all construction. P p p p 9 r+T r requirements: �0 E.. s ' ,., PT2 60 sec./in. 36 �Q�oN 'r TOWN F UEENSBURY WARREN COUNTY STATE F YOR9C Ir5 ry, 7. Soils shall be improved in the leach field area to allow for a percolation �. O O Q O NEW •B°@` rate between 1 and 5 minutes. In no case shall the percolation rates Trench line #1: 32 LF s Percolation Tests Performed By SS, AA. Trench line #2: 28 LF Q�� �Qcc��O Q� cc� �� a exceed 5 minutesfinch. Soils stall be improved by either mixing the D�� w D� Jv ��Q��1 ����D Trench line #3: 20 LF , w existing soils with fines to achie\e slower pert. rates or complete soil Test Plt Results: 2 t o d D d s G3G�I�,1C3�UTATIOnNI replacement to a depth of 2 f,'et below the leach field elevation. 4. Contractor to at all times comply with requirements set forth in the F p 4p79736 �� 1 ,i 1. µno; • , . .. r., n er to 7 - Wastewater Percolation tests shall be performed by the engi a verify validity of in D n tion NYSDOH Design Document 10NYCRR Appendix 5 A, Waste ate R , ipN o p ° Y,I No. esc p DRAWN ��. �� APPROVED ��° SCALE: �I°° e ®° FILE: HUNSICKER.DWG place percolation rates for either iTethod. Mechanical compaction should Treatment Standards for Individual Household Systems & Individual 1[K12 Msxoiofi tap 014ap Na uTecfifTiOF"Mc andFx C„Inpurmc .'• "�'` -: - TP1 0 -4 Topsoil with organics [� ���� N /A ' be used in place of vibratory methods to avoid segregation. Soils not g Residential Treatment Systems Design Handbook and the ELJEN DATE: 10/15/02 � ® O° III passing perc. requirements shall be modified until proper rates can be 4%4' CM Brown Sand with some cobble (fill) Corporation Design and Installation Manual for NY. obtained. no ground water observed no mottling observed C UTTE eS EDGE GROUP, LL� _ 8. Contractor shalt provide as-built drawings of the system. no rock or impervious layer observed PE LISCENCE NO:079736 si•rsEr of