Loading...
93-372 .r «4 • CERTIFICATE 01.E COMPLIANCE TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Date This is to certify that work requested to be done as shown by Permit No. 93-372 has been completed. This structure may be used as a deck Location Geni Ata Lane Owner Stephan and Licj.a Mackay 43-2-13 By Order of Town Board TOWN OF QUEEN BURY Director of Building & Code Enforcement BUILDING PERMIT y TOWN OF QUEENSBURY b No. 93-372 WARREN COUNTY, NEW YORK 0 • PERMISSION is hereby granted to STEPHEN & LICIA MACKEY OWNER of property located at Genista Lane Street, Road or Ave. Ali w in the Town of Queensbury,To Construct or place a Replace Exist Deck at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is 21 McArthur Dr Glens Falls NY 12801 in 2. CONTRACTOR or BUILDER'S Name rt ro same Patrick McGarr 3. CONTRACTOR or BUILDER'S Address sr) tl O I-,• 4. ARCHITECT'S Name CD 5. ARCHITECT'S Address rt 6. TYPE of Construction—(Please indicate by X) (D ( kNWood Frame ( ) Masonry ( )Steel ( ) 7. PLANS and Specifications 400 sq ft Deck to replace existing as per plot plan, No. specifications and application. 8. Proposed Use (D ro Deck a cD 32 .00 July 14 94 $ PERMIT FEE PAID —THIS PERMIT EXPIRES 19 c (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Queensbury before the expiration date.) I ' Dated at the Town of Queensbury this 14th Day of July 19 93 C7 SIGNED BY ( , for the Town of Queensbury Y /4and Zoning Inspector r 'fir TOWN OF QUEENSBURY Fee Paid ,g BUILDING & CODES DEPARTMENT Permit # --J . APPLICATION FOR: PORCHES-DECKS- DOCKS & BOATHOUSES .345e ® Est. Cost 26)6. A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTI �" PLEAS A1VSWER LL OF THE FOLLOWING: ' The undersigned hereby applies for a Building Permit o d 1 .4pTlowingwork which will be done in accordance with the description, plans and s cif OAtubmitted, and such special conditions as may be indicated on the permit. TWO S * 0 ..,E , TURAL ,PLANS SHALL BE SUBMITTED WITH THIS APPLICATION. Sz,4. {-' Owner of Property: ST /4 Pi-L/C/4 G�ike1e-e' P.O. Address 2./ /n a -T(�U,2 a, , P � l-w 1 lu s Phone # -7 -.s3eT Property Location C.SLLnl LA,oz( _i",61:1-c f G; /L-s;,4- LA1 ) Tax Map # Subdivision Name (If applicable) P ON RESPONSIBLE OR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: A,'Name: j i2/CdG -�� Address 5 &Pif r W-.. Phone#723��2. BUILDING SPECIFICATIONS: k_p) ettl f lsfir'J diet. Type of work to be done: Porch De Dock Boathouse (Circle one) 41 Size of Structure to be built (square footage) : , CJCDSat, / Foundation Material : Width 8‘tiR Thickness a," Depth of Footing, below grade: 3 �1 e ! Size of Posts or Studs: x V x l(o Long • Size of Floor Joists: 9.. x 8 x /6 Span Decking or Flooring Material : s/y X G. " How will Porch or Deck be fastened to building? o;?X ii, 44,#_0 /o hioe.454. A Ji 7-/4 2 x 8 fi/.i0✓4I-e .S' .,..I/s•t D A.°vr -kid s rS If Roof Will Be Installed, Answer Following Questions: Size of Posts or Studs: x x Long Roof Rafters: x Spacing Span Roof Trusses (pre-engineered spacing): Span Type of Roof: Sloped Flat Shed Other (Circle one) Material of Roof: ZONING INFORMATION: TWO PLOT PLANS MUST BE PREPARED AND SUBMITTED, drawn reasonably to scale and attached hereto, showing clearly and distinctly all buildings, whether existing or proposed and indicate all stet back dimensions from property lines. Show location of water supply and location and configuration of septic disposal area. Size of Property: SCa ft. x /0 c) ft. , Existing building(s): Size 2.2 ft. x 3t, ft. Size ft. x ft. Use of Existing building(s): — Proposed structure, distance from property line: Front yard 2 2- ft. Rear yard 30 ft. Side yards c ` ft. and /O` " ft. If on corner, setback from side street: ft. DECLARATION To the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance, and all other la ertaining to the • -.posed work shall be complied with, whether specified or not, and at su work is . .thorized by the owner. r DATE: 7 9 �...3 /% l SIGNATURES 4" 4Ih ----_,, Owner, wner's Ag:nc, , Architect, Contractor REVIEWED' BY CODE ENFORCEMENT OFFICER, DATE SIGNATURE (-' 1 TOWN OF QUEENSBURY 531 BAY ROAD 4111tall- -ea QUEENSBURY, NEW YORK 12804 TELEPHONE (518) 745-4447 BUILDING INSPECTOR'S REPORT FINAL INSPECTION REQUEST FOR INSPECTION RECEIVED 41 - - 0 3 NAME Pt -i( -� ;.S k _. LOCATION 6.--1 Lei- C C?I 1/4,1 S 4`-'2+ DATE _--7-)-)-9,5 PERMITI 9 J 3 7 L TYPE OF STRUCTURE 7:1 . t RECHECK _FIRE MARSHAL APPROVAL (COMMERCIAL STRUCTURE) FOOTING FOUNDATION BACKFILL FRAMING _ROUGH PLUMBING FINAL ELECTRICAL SEPTIC _INSULATION __ OD REMARKS I APPROVAL N/it YES NO CHIMNEY HEIGHT/LOCATION i I B VENT/LOCATION 1 1 PLUMBING VENT ROOFING i / SIDING \ i DECK/PORCH/STEPS/RAILINGS / RELIEF VALVES ` FURNACE/HOT WATER OPERATING; BASEMENT INSULATION/DUCTWOR INTERIOR TRIM/PRIVACY DOOR FINISH FLOORS: BATH/KITCHEN WATERTIGHT OTHER FLOORS SWEEPABLE OTHER FLOORS CARPETED ' STAIR CLEARANCE/RAILINGS HANDICAPPED ACCESS SMOKE DETECTORS BATHROOM FANS/WHOLEHOUSE FANS ALL PLUMBING FIXTURES OPERATING GARAGE FIRE PROOFING DOOR CLOSERS OTHER FIRE SEPARATION FIRE/DEMISE WALLS DUMPSTER SITE PLAN/VARIANCE REQUIREMENTS FINAL ELECTRICAL OK TO ISSUE C/O OR C/C -/ COMMENTS: ARRIVE DEPART INSP T TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT 531 BAY ROAD QUEENSBURY, NEW YORK 12804 TELEPHONE (518) 745-4447 BUILDING INSPECTOR'S REPORT REQUEST FOR INSPECTION RECEIVED 1/ 1/9.3 NAME, !4A LOCATION DATE 7// 0,1 PERMIT if 93-3 7a TYPE OF STRUCTURE ',Lye RECHECK APPROVED N/A YES k FOOTINGS/PIERS MONOLITHIC POUR FORM REINFORCEMENT IN PLACE THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROTECTION FROM FREEZING FOR 48 HOURS FOLLOWING THE PLACEMENT OF THE CONCRETE. MATERIALS FOR THIS PURPOSE ON SITE FOUNDATION/WALL POUR REINFORCEMENT IN PLACE FOUNDATION/DAMPROOFING BACKFILL APPROVAL ROUGH PLUMBING PLUMBING VENT/VENTS IN P .ACE PLUMBING UNDER SLAB FRAMING: JACK STUDS/HEADERS / BRACING/BRIDGING JOIST HANGERS JACK POSTS/MAIN BEAT HEATING ROUGH-IN INSULATION: J FOUNDATION WALLS NTERIOR R- FOUNDATION WALLS TERIOR R- FLOORS R- WALLS R- CEILING R- DUCT WORK OR/PIPING IN UNHEATED SPACES REMARKS: / (5; A , Cal/ wA f4 "7 (,- ARRIVE /0; 3$ DEPART INSPECTOR ,.: „ ; ,,,---':P7.-;!!.-1:::1., ''''',-.4i'l,-;14•''..; :7'.:::',!':;:,,,:,- - .-1,..;::-.: i .; - .:1, ':--*:feri ,-:‘,i-f-,-4-f,4,,,,:,,,:,4,7‘ ,,,..\'' mtiuk. Cfrwty LA-4.ft_, /0'1 A CLJO of &-__hlsrA- 4 0711:1 ece: V c..1 towhiffed ;co 2_r i .r Of '' I 1 OA „....___71 I.411 ' 1/ Cay i eke?.ZZ Vt° tiv . .... 7 \ tS1 . t 331 (4',.-`, AP P Fl ‘'4.1 " ' ‘ lication 8 N\ , App i 3 JUL I 4 i3 1 xsxe Air Mar. 49 Q Zoning Ad inistrato; \\\N 1r TowN oF • EENSBUR t' \ , - ,-- - . l's, N\IIIIItti:. t_o_iii ,D7, qihtt 4) @ 7‘ 1 . , . Y .1:p•-•... .- *"'"— '--- . 1._ . • ,..‘ ... v.,., - Aril-X.EliiNi3Wf . _ • ' B — r ,, 'i+ed examin _ 42,\L ''--T,4-;04*-L4 ct sr;,, twki-1-•itittpiwriP:' 44444 reeld r t bt C4/' , as inclicatm, be at,:- - Tabora al-e i, Ft,Per I-mow ...a ......... ......„ golik ---Lpite raskio • I t,the code •NNN' -°1-1 .1-r- ''''''" "!. j...k. •,;11'.. LD 171 DATE _..,.... -71r ..._. S/1'7Y N/f{ 5-,i s-r yr `71„,_1-, o n7 07/ - 'Sl'°// v/ (7/7 7 1e . ;;;7 c-j ----s- `\ pr f7 - - y- ►' 'I f •: ; ,,7 t x 4,1/C,, 5( _ . 5 _ li I Ilir,N 5( i 1.' -- - - 1 0 ' '-' 1 „,,, '17ffP- r IIM , PLAN VIEW CUSTOMER - DATE' 06/29/93 REF PPM38292 . /cr.. • to \ is c.� 2)(t.aysq St. +edn..r S 'fix 7` 41.J43 au_ Jaisrs ZkSS ALL 17RL141,4..iL sly x Ca I Load and support Your decK will support a 44 PSF live load. Posts have 36' below-ground post support tiff LIST CUSTOMER -- DATE 06/29/93 REF PPM38292 is T-----1_ /I i 1illii; u 4 in t4 ® 14 p [C] ® ® I-4 ® ® © \ , aQ o t fil eirg ii W ' tit I I I � i I i r Ell LABEL LEtSTH BEVELS LABEL LENGTH BEVELS A Joist 22'11 3/4' FO R45 0 ledger 28' B Joist 24'3 3/4' FO R45 P fascia 4' F45 S22 C joist 25'7 3/4' FO R45 P ledger 3'9 7/8' FO S45 D joist 26'11 3/4' FO R45 0 fascia 8'5 13/16' F22 S22 E joist C16) 9'6' 0 ledger 8'3 11/32' F45 S45 F joist 9'3 1/4' FO R45 R fascia 22' F22 S22 G joist 7'11 1/4' FO R45 R ledger 22'1 3/4' F45 S45 H Joist 6'7 1/4' FO R45 S cap 8'9 9/16' F22 S22 I joist 5'3 1/4' FO R45 S section 2'7 25/32' J joist 3'11 1/4' FO R45 T cap 22'6 3/8' F22 S45 K fascia. 8'S 13/16' F22 S22 T section 3'6 13/32' K ledger 8'3 11/32' F45 S45 U cap 6'4 1/2' F45 SO L fost-ta 22' F22 S45 U section 2'9 1/4' L ledger 21'9 7/8' F45 SO V cap 41 7/8' FO S22 M fascia 6' F45 S45 V section 3'7 1/2' M ledger 5'9' W cap 8'9 9/16' F22 S22 N fascia 18'1 1/2' F45 S45 W section 2'7 25/32' N ledger 18' X cap 22'3 23/32' F22 S22 0 fascia 28'1 1/2' F45 S45 X section 3'6 13/32' BEAM LAYOUT CUSTOMER -- DATE 06/29/S3 REF PPM38292 to K. N K.r m h o -$ o v v CO t 1 r 1'5 7/8' ) [ Al _ _.. - - —am a 6 1/4' j/4'6 15/16' /� 41 8'11 1/2" / v 4'3' , 21'4 3/16' 13'9' , Lid'11 _� 6 1/4' BEAM BEAM POST POST LABEL LENGTH COUNT SPACING A 8'3 1/8" 2 6'10 5/8" B 8'3 1/8' 2 6'10 5/8" C 20'1 1/2' 3 9'11' D 27'10' 6 5'6 3/32" E 5'9' 2 5'S 1/2' F 5'9' 2 5'5 1/2' Post spacing is measured center-to-center. Depth of' concrete footers 36 inches.