Loading...
ResCheck .„ 7-7(9 z_ r h,,,; -/'D v . Permit Number (5 CDLCZNi REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck Soliware Version 3.6 Release 2 Data filename: C:\REScheck\19FARMINGTONPLACE.RCK PROJECT TITLE: TB237.DGN- "THE SPRINGS" COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW/WALL RATIO: 0.14 DATE: 07/12/06 DATE OF PLANS: 7/2006 PROJECT DESCRIPTION: LOT #19 FARMINGTON PLACE - FARMINGTON GROVE TOWN OF QUEENSBURY WARREN COUNTY T&B ASSOCIATES • ,\ }-b fictriqN\"° C%,t DESIGNER/CONTRACTOR: '►.4M, DANFORTH H. CHRISS ti;? ,; #27 ELECTRIC AVE. v� '0r;_�; I EAST GREENBUSH, NY 12061 v COMPLIANCE: Passes r '� 3�A A.; Maximum UA= 501 Your Home UA= 391 22.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 23 30.0 0.0 1 Ceiling 3: Flat Ceiling or Scissor Truss 1150 30.0 0.0 40 Ceiling 2: Flat Ceiling or Scissor Truss 10 30.0 0.0 0 Wall 1: Wood Frame, 16" o.c. 1345 19.0 0.0 67 Window 1: Vinyl Frame:Double Pane with Low-E 131 0.340 45 Door 1: Solid 18 0.160 3 Door 2: Solid 39 0.320 12 Door 3: Glass 40 0.310 12 Comments: 1ST FLR. SIMONTON PROFINISH VINYL 6068 LOW E/ARGON SLIDING PATIO DOOR Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: 2ND FLR. WALK-IN CLOSET FLOOR OVER 2-CAR GARAGE W/MIN. 6" F.G. [ ] 2. Floor 2: All-Wood Joist/Truss:Over Outside Air, R-19.0 cavity insulation Comments: 2ND FLR. FOYER SHELF AREA W/MIN. 6"F.G. Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 92 AFUE or higher Make and Model Number G1:2.7YI7/ I f 6 Air Leakage: gi [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals it all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Wall 2: Wood Frame, 16" o.c. 1318 19.0 0.0 68 Window 2: Vinyl Frame:Double Pane with Low-E 164 0.340 56 Window 3: Vinyl Frame:Double Pane with Low-E 25 0.350 9 Basement Wall 1: Solid Concrete or Masonry 1123 11.0 0.0 73 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 77 19.0 0.0 4 Floor 2: All-Wood Joist/Truss:Over Outside Air 13 19.0 0.0 1 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best ofhis/her knowledge, belief and professional judgment, such plans or specifications are in compliance with this Code. Builder/Designer7) 0......1 • C Date 7 /2 DC NehfcgcL •sP � 4 4( 1 .41. or • RES check Inspection Checklist New York State Energy Conservation Construction Code RES check Sojlware Version 3.6 Release 2 DATE: 07/12/06 PROJECT TITLE: TB237.DGN- "THE SPRINGS" Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 1ST FLR. DINING ROOM CEILING W/ 10"F.G. [ ] 2. Ceiling 3: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2ND FLR. CEILINGS W/ 10"F.G. [ ] 3. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 1ST FLR. FIREPLACE CEILING W/ 10"F.G. Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: 1ST FLR. 2X6 8 FT. WALLS W/FLR. RIM & W/6"F.G. [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: 2ND FLR. 2X6 8 FT. WALLS W/FLR. RIM& W/6"F.G. Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 7.6'ht/6.6' bg/7.6'insul, R-11.0 cavity insulation Comments: BASEMENT 8"POURED 8 FT. FOUNDATION WALLS W/3"F.G. Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-Factor: 0.340 For windows without labeled U-fictors, describe features: #Panes Frame Type Thermal Break? Comments: 1ST FLR. SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS [ ] 2. Window 2: Vinyl Frame:Double Pane with Low-E, U-fictor: 0.340 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? No Comments: 2ND FLR. SIMONTON PROFINISH [ ] Yes [ ]E/ARGON [ ] 3. Window 3: Vinyl Frame:Double Pane with Low-E,U-ficto: 0.350 L SH W WINDOWS For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: 2ND FLR. SIMONTON PROFINISH VINYL ARCH TOP FIXED LOW E/ARGON WIND()) Doors: [ ] 1. Door 1: Solid, U-fictor: 0.160 Comments: 1ST FLR. THERMA TRU 2868 INSUL. FIREDOOR [ ] 2. Door 2: Solid, U-fictor: 0.320 - Comments: 1ST FLR. THERMA TRU LOW E INSUL. FRONT DOOR W/SIDELIGHTS [ ] 3. Door 3: Glass, U-fictor: 0.310 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. • Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2" Runouts 1" and Less 1.25"to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(fr feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 7• NOTES TO FIELD (Building Department Use Only) Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part ofa circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 or chilled fluids below 55 °' must be insulated to the levels in Table 2.