Loading...
2005-367 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (3y.ro OCCUPANCY Permit Number. P20050367 Date Issued: Friday, January 20, 2006 This is to certify that work requested to be done as shown by Permit Number P20050367 has been completed. Tax Map Number. 523400-308-007-0001-029-000-0000 Location: 29 WESTBERRY Way Owner: TRA-TOM DEVELOPMENT, INC. Applicant: THOMAS FARONE & SONS INC. This structure maybe occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, AV Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforc ment Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050367 Application Number: A20050367 Tax Map No: 523400-308-007-0001-029-000-0000 Permission is hereby granted to: THOMAS FARONE& SONS INC. For property located at: 29 WESTBERRY Way in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: TRA-TOM DEVELOPMENT, INC. 667 STATE ROUTE 9 Fireplace Garage-2 Cars d GANSEVOORT NY 12831-0000 Single Family $290,000.00 Total Value $290,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency FARONE CONSTRUCTION PO BOX 804 ROUTE 9 GANSEVOORT. NY 12831 Plans&Specifications 2005--367 LOT 4 HSE#29 WESTBERRY WAY 2848 SQ FT SINGLE FAMILY DWELLING $390.16 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, June 02, 2006 (If a longer period is required,an application for an extension must he made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow f Queens ry; T day, June 02, 2005 SIGNED BY for the Town of Queensbury. Director of Building Code nforcement l Permit No. r ✓ I Iding&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 2 Bay Road,Queensbury,NY 12804 Recreation Fee rve Hatin,Director codes@aueensburv.net RK one: (518) 761-8256 FAX: (518)745-4437 'rincipal Structure Building Permit Application ,pplication & Plans subject to review before issuance of a valid permit for construction. Istructions: A permit must be obtained before beginning construction. No inspections will be made until the pplicant has received a valid building permit. All applicants' spaces on this application must be completed and lust appear on the application form. pplicant/Builder C�,&e �ZA_ Owner: address: ez2E `d _ PC gwcRil Sfoy Address: Phone: Home Phone: :mail Address: ___S� oivfi-R-0 Email Address: -el( Phone: Cell Phone: :AX Phone: FAX Phone: 'erson responsible for supervision of work with respect to building and codes compliance: Name: I�YLer.�d�- Address: Phone Location of proposed construction: Lot No. Legal Address: 2C1 Tax Map Number: Subdivision Name: ` Estimated Cost of Construction: $ 1] REC� g ED Proposed construction is for: _✓Residential Use _.Commercial Use MAY Name of Business: TOWN OF BUILDING AND CODE Y If proposed construction is an addition,what will use of new addition be? New Addition Alteration Proposed Construction I Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height Single-Family Dwellinge2 3 oZ a� Ft.&1n. Two-family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 L Type of Heating System: Electric, Oil, Ga Wood, Forced Hot Air, Baseboard, Other: If a fireplace and/or woodstove are being installed, please refer to a separate application. Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described' Premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. Date: Applicant/Builder Signature: The application of ated is hereby approved and permission granted for th c nstruction, reconstruction or alter tion a buil ng/ nd or accessory structure as set forth above, r• g/ Date: �-G Authorized Signature: LASue Hemingway\Building.Permit. RMS\Principal Structure Permit Application.doc V:12/14/04 Application for Permit—Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: ..................................... ................................ ...................................... titer a� Office Use Location of installation: File Permit No-DO 'S- 3G 7 Tax Map No. Fee Paid Owner's Name: ................................................ ....................................................................... Address: 2. INSTALLER'S NAME PHONE NO.�Q(I 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate 4 bedroom(s) and multiply 4 of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm. = 1991 -present x 110 gal/bdrrn = q % Garbage Grinder Installed yes no VFLD, Spa or Whirlpool Installed yes 4 no MAY 2 6 21' 4. PARCEL INFORMATION: (circle applicable information&indicate measurements)BUILDING TOWN OFOUEM,.. ' hv SDU-Nature Ground Water Bedrock or Impervious Material Water VRply Flat and at what depth at what depth (munici2a�l Flat loam -761-7 0 eet feet --we-77 Steep slope clay if well; water supply %slope other from any septic-system depth: absorption is_ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: —minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. Septic Tank: /A5D gallon (min. size 1,000 gal) Tile Field: each trench. Total System Length: ft Seepage Pit(s): number of Q size of each: ft. by_f Size of Stone to be used: depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gallons /TOTAL Capacity: _gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. V� 6 1 6-)1-b L, ---- Signature of responsi e person / Date - — Fire Marshal's Office Town o1'Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date_ ! L'_ 20 i. S Permit No.c, Q) Application is hereby made to the Building do Codes Office./or the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building lode. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to pet form required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: � t�� ti t�'a�'c ::; ��;� � ,!� . � -���-,.... Stove: wood coal pellet gas Fireplace insert Address: , t; ?:'' T Fireplace, factory-built: wood xis; Fireplace, masonry: wood gas Furnace: wood gas oil Phone: - t If non-masonary applicance, please provide Owner: Manufacturer Name: Address: I - _--� Model Number: Chimney Information Phone: (circle appropriate words) Masonry block brick stone Flue tile steel size: inches Exact Address: ,r of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction IInstallation must con grin to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Y Handouts regarding required inspections. Double ivall / Triple iaall / hisylalvd-, d,.' Direct venting Chinvtev Liner l Ca,,�.rEsfer'�r n�ps�.z�'m�iE—To�� of Que�n,e�buxy, ,rTB�Yori� - i Fire Marshal Code# $Collected $Rejrnded Received from (reftarrled to).t +� address: A 173 3389 (190) Public Safety E-��,�,�. _ address.-______ -- A 233 2655 (230)Minor Sales DATE: o< White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / Pink&Goldenrod(Cashier's Dept.) Check Residential Plan Review: One&Two Family Dwellings Y/NIN/A )Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf t 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. "(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6 op in 10'Exterior Grade raining Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where wired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Pla orms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2 Story Sm ke Detectors Battery Backup and Proper Location athroom Fixtures Proper Clearance Hall Width,36"min. andrails More Than One Riser On Open Sides LoAing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation G age Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation ; All Paperwork Signed Septic Inspection Report Office No. (518)761-8256 Date In sp ff��ti© e�uest received: Queensbury Building&Code Enforcement Arrive: . am/p epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's I Itials: NAME: PERMIT NO.: C —3 LOCATION: t J�� INSPECT ON: r z0 o RECHECK: Comments and/or diagram Soil Type., Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft, Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: P!Ping Size Type Building to tank Tank to Distribution Box Distribution Box to Field l Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft• Foundation to absorption ft. Separation of Pits ft. D t Conforms as per Plot Plan I Y N_j 6,1U _ / ��ec�(//✓ "L ���/ �`"��� Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Statu . Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved LwSueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 JAN 20 2006 10: 38RM HP LRSERJET 3200 p. 2 N NACE ENGINEERING, 7: 1 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax - 518-792-8511 7 RECEIVED January 20, 2006 JAN 20 2m Job #46175 TOWN Ui- UUttivbbURY New York State Dept. of Health BUILDING AND CODE 77 Mohican Street Glens Falls,NY 12801 i RE: Pine Ridge Subdivision- Queensbury(T) 29 Westberry Way(Lot#4) -Septic System i i Dear Sir/Ma'am: This letter is to inform you that I inspected the completed septic system for the house on 29 Westberry Court (Lot#4) in the Pine Ridge Subdivision on January 4, 2006. The septic system as installed was for a four bedroom house and consisted of a 1,250 gallon septic tank and 220 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. i Sincerely, Thomas R. Center Jr. ,PE i cc: Dave Hatin, Town of Queensbury Tom Farone i Town of Queensbury Fire Marshal low 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# l Schedule Inspection Time f am pm anytime Inspector Name G Address Rough LI Final V Appliance Manufacturer-- Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chasc­ Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White-W$Dm Yellow r Plnk—Fare ltlarsltai --� Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: : am/pm Date Inspection request received: _ Inspecto *fiaj��! NAME: " PERMIT#: �,,� 7 LOCATION: C DATE: —Q� TYPE OF STRUCTURE: Comments Yes o N/A 1 Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches 41 Roof Complete/Exterior Finish Complete 01v Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 01 Crawl Spaces 18 inch x 24 inch access, i s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum11/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed roperly Of Gas Logs in Sealed or Gl s Enclosure Final Electrical / f r Final Survey Plot PIE Ip As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Final Survey Inspection Dept.of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: — NAME: LOCATION: PERMIT M D 3(� Final Survey Plot Plan A roved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the survey has been: Craig Brown, o g Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey Zoning Administrator.doc MAP REFERENCE: SUBDIVISION PLAN RICHARD P. SCHERMERHORN YAGNaY7C DATED: FEBRUARY 11, 2003 LAST REVISED: MARCH 17, 2004 BY: VAN DUSEN & STEVES LOT 5 �0IOU \ ooh 2so 2. I / y0GS�c.Fp \ fi / J ° / / LOT 4 1 / 51,949 sq. ft. / 1.19 acres / LOT S o / 25; no cut zone / 50.00 / 1 have seen or observed, or believe S06007-55NW aI► objects such as houses, well saw evidence of, / shaven on this document ! also retry es, fences, etc., � � personally measured the � p esent that! have N / istances set forth on the iagram." SIGNATU � `�� 20' no cut zone DAT ��� K7 17�26 RECEIVED S05°0 {fir MAY 2� - 2005 TOWN OF QUEENSBURY BUILDING AND CODE ADDITION TO A SURVEY ate MAY 3, 00 �`RBEARM A ""SED LAM Ir.SYO S S Plot Plan made for Scale 1'=30' MAP BEARING'A IKON 7 LAND SURVEYORS SEAL IS A VIOLATION OF SEC1101 72OY,SUB-pN9ON 2 OF TE NEW YORK STALE EDUCATION LAW.' S MARKED COPES ROMORIGINAL THE OF THE OF SURVEYORS SURVEY MARIEID W1AL L AN D60M OF THE LAND 9NE COMM" S- 1 BE DDN�,N BE CAL ,NE ODP T H O MA S J. FAR O N E & S O N CERWICATLONS INDICATED HEREON SIGN"THAT liK SURVEY WAS PREPARED N ACCORDANCE WITN THE Land Surveyors °° � FOR LAW �° ° BY 11E NEW YORK STATE ASSOCIAl1ON Di PROPE491ONAL LAW E PERSON F SAD 0M INE SURVEY SMALL RUN D.A 1 TO iFE PERSON FOR MIOM NHE SURVEY IS PREPARm.AND ON NIS BEHALF 70 7W O71E OMPANY,OO\4RIYOITAL SHEET 169 Haviland Road Queensbur New York 12804 OF I AGENCY AND uNnra NSTITUIDON L�HEREON.ao Town of Queensbury, Warren County, New York y, TO THE ASSIMn OF 7!E LENDING NSMNRN.' FARONE (518) 792-8474 New York Lie. No. 50135 [_N701DATE DESCRIPTION DWG. NO. 02392-4 Septic Inspection Report Office No.(518) 761-8256 Date Ins ti request received: Queensbury Building&Code Enforcement Arrive: am/ epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto s Initials: NAME: c\Y(, PERMIT NO.. L LOCATION: INSPECT ON: — L RECHECK: Comments and/or diagram Soil Type: Sa oam Clay Type of Wa er: Mun ci l/Well Water Waterline separation distance Well separation distance ft. Other wells: ft. Absorption Field: Total length 2 ft. Length of each trench 5 ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Si e Typq Building to tank Z Tank to Distributio Box K 3 Distribution Bo ield/Pit K r-✓VQ Opening Sealed /N/Partial End Cape Location/Separations Foundation to tank ft. Foundation to absorption 7,0 ft. r0 Separation of Pits ft. Conforms as per Plot Plan Y Engineer Report and As-Built Y V N Location of Syst m on Property: v Front ear Left Side Right Side Middle Front Middle Rear System Use Status: proved artial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 1/6/05 WACIINTJ�- w r > NIX / VO / 34 00 f r4 sq. ft. LOT 3 /acres g / "{ have seen or observed, or believe f saw evidence of, fall objects such as houses, wells,trees, fences, etc., / shown on this document. i also represent that 1 have p senaiIy measured the A istances set forth onthe¢iag Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm.noD�epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: _0 5-3 (07 LOCATION: INSPECT ON: 11 - y - CAS TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Pl-ce \ ) 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Lim Water Supply Piping Air/ Head 50 P .I for 15 minutes lation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: �V� / /V1 j Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/prlp �epa _ am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: S'3 197 LOCATION: INSPECT ON: /0 TYPE OF STRUCTURE: Y N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test R_ in / Vent / i / Head .S.I. or 10 ft. above highest connection for 15 minutes Pressure Test EP er Supply Piping Head .S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Town of Queens"Fire Marshal low 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# Schedule Inspection b__ me ain m anytime in Name S Ct�CC�it�s Address t�1 � Rough In7al_, Appliance M7Factory cturer _ �ie�0�— Model# — GGH �� �� Direct VentDouble Wall Trile Wall Insulated Built Chimney Flue Size p _ - Yes NoN/fA/ Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) �_ � Pink-Fire MarAd Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: I / Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:Z TA� NAME: PERMIT#: D J ~3�n LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Framing COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers t Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour ire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Imo, Queensbury Building&Code Enforcement Arrive: am/p e t7am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: i NAME: j=A-jzvA1 G PERMIT#: LOCATION: +4 INSPECT ON: 1,5� TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ;4 '/z w) 16 gauge(8) 16D nails each side aft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/1-IM7 art: m/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: QS--0 J LOCATION: INSPECT ON: -- TYPE OF STRUCTURE: f Y N N/A 'J Framing COMMENTS 1 Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center �kee'and water shield 24 inches from wall 106 Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/Zj De a pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: - ��Fr PERMIT#: LOCATION: 45- 7- INSPECT ON: TYPE OF STRUCTURE: Comments ----- Y N N/A Footings Piers _ Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Walipour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Tampproofing/ Waterproofing rain Daylight or Sump ain Stone: width above footing f for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes,InspectionTORMSToundation Inspection Report.doc January 28,2003 Iv.51b Foundation Inspection Report a�J Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p��� Depart: nv`pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: y-�-__i�-- NAME: 2lJ�vC PERMIT#: LOCATION: 2-47 INSPECT ON: TYPE OF STRUCTURE: Comments v_T---- Y N N/A Footings Piers Monolithic Slab Reinforcement in Place ^ The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour enforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing F mg Drain Daylight or Sump noting Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 � Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p , Depart arrv`pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: �Gti 1� PERMIT#: �_ ( LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers __.. Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. M als for this purpose on site. undation/Wall.pour Reinforcement in Place T Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. I.\SueHemingway\Building.(:odes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 7 Queensbury Building &Code Enforcement Arrive: am! Depart- am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: PE IT#: c c 3�O —ter _ LOCATION: oc- SPECT ON: TYPE OF STRUCTURE: Comment Y N N/A Footing Piers Monolithic Slab Reinforcement in Place The contractor is responsib providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 30 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck Solware Version 3.6 Release 2 Data filename: C:\Prograrn Files\Check\REScheck\2283-01 CANTERBERRY-FARONE-LOT31-31 WOODSHIRE COURT, QUEENSBURY.rck PROJECT TITLE: PLAN NO.2283-01CANTERBERRY COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.15 DATE: 05/14/05 DATE OF PLANS: MAY 14, 2005 PROJECT DESCRIPTION: THOMAS J. FARONE AND SON LOT 31-31 WOODSHIRE COURT QUEENSBURY,NEW YORK 12804 DES IGNER/CONTRACTOR: WILLIAMS &WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS, NEW YORK 12801 COMPLIANCE: Passes Maximum UA=457 Your Home UA= 355 22.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door PeriJneter R Value R-Value U-Factor LJA Ceiling 1: Flat Ceiling or Scissor Truss 1140 30.0 0.0 40 Wall 1: Wood Frame, 16" o.c. 1154 19.0 0.0 56 Window 1: Vinyl Frame:Double Pane with Low-E 131 0.320 42 Door 1: Solid 35 0.130 5 Door 2: Solid 21 0.130 3 Door 3: Glass 42 0.330 14 Wall 2: Wood Frame, 16" o.c. 1140 19.0 0.0 58 Window 2:Vinyl Frame:Double Pane with Low-E 167 0.320 53 Basement Wall 1: Solid Concrete or Masonry 1154 11.0 0.0 81 c ; Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Floor 1: All-Wood Joist/T russ:Over Unconditioned Space 70 19.0 0.0 3 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Pro 'ficztion fessional has st ped and signed this page, they are attesting that to the best ofhis/her knowledge, belies; and professional judgm t, such s�or p s are in compliance with this Code. I (� Date R s "O" 4 t REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck Solware Version 3.6 Release 2 DATE: 05/14/05 PROJECT TITLE: PLAN NO.2283-01 CANTERBERRY Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0'ht/6.0'bg/8.0' insul, R-11.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-fcctor. 0.320 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor 0.320 For windows without labeled U-fcctors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ )No Comments: Doors: [ ] ( 1. Door 1: Solid, U-factor: 0.130 Comments: [ ] 2. Door 2: Solid, U-factor: 0.130 Comments: [ ] 3. Door 3: Glass, U-factor: 0.330 Comments: Floors: [ ] ( 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and foors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] ( Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Retum ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics(adhesives), mastic-plus-embedded-labric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pie Sizes Heated Water Non-Circulating Ru_nouts CirculatinLy Mains and Runouts Temperature(F) lip to V Urs to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ranee(F1 2"Runouts 1" and Less 1.25"to 2" " Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(1flr£ed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 L5 NOTES TO FIELD(Building Department Use Only)