2005-414 TOWN OF QUEENSBURY FILE COPY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20050414 Date Issued: Tuesday, November 15, 2005
This is to certify that work requested to be done as shown by Permit Number P20050414
has been completed.
Tax Map Number: 523400-315-010-0001-017-000-0000
Location: 6 QUINCY Ln
Owner: MICHAELS GROUP LLC THE
Applicant: MICHAELS GROUP LLC THE
This structure may be occupied as a:
Fireplace By Order of Town Board
Garage - 2 Cars Attached TOWN OF Q EENSBURX
Single Family Dwelling
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050414 Application Number: A20050414
Tax Map No: 523400-315-010-0001-017-000-0000
Permission is hereby granted to: MICHAELS GROI TP LLC TUR
For property located at: 6 QUINCY Ln
in the Town of Queensbury, to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MICHAELS GROUP LLC THE
10 BLACKSMITH Dr Fireplace
MALTA, NY 12020-0000 Garage-2 Cars Attached
Single Family Dwelling $281,900.00
Total Value $281,900.00
Contractor or Builder's Name /Address Electrical Inspection Agency
MICHAELS GROITP
SUITE 1
10 BLACKSMITH Dr
MALTA. NY 12020
Plans&Specifications
2005-414 LOT #17 HSE#6 QUINCY LANE
3383 SQ FT SINGLE FAMILY DWELLING
$460.16 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, June 30, 2006
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated the T o sb ursday, June 30, 2005
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Permit No.
Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 4-2-5�CtD
742 Bay Road,Queensbury,NY 12804 Recreation Fee A� y -622
Dave Hatin,Director codesQaueensburv.net
Phone: (518)761-8256 FAX: (518) 745-4437
Principal Structure Building Permit Application
Application & Plans subiect to review before issuance of a valid permit for construction.
Instructions: A permit must be obtained before beginning construction. No inspections will be made until the
applicant has received a valid building permit. All applicants' spaces on this application must be completed and
must appear on the application form.
Applicant/Builder M`c-"atLZ GrzjtvF Owner: S �
Address: iC> 13�LVS AIJIA VlZtyr-- , NaL"M Address:
Home Phone: ep%9- co31 I Home Phone:
Email Address: Email Address:
Cell Phone: Cell Phone:
FAX Phone: FAX Phone:
Person responsible for supervision of work with respect to building and codes compliance:
Name: J-OKN-f L-0C.ASC-10 -'VRC%SE .rr tAAt,.,04ICZ
Address: Phone 165-1 - 3144
Location of proposed construction: Lot No. Legal Address:
Tax Map Number:_, n �'� "—� / Subdivision Name:
Estimated Cost of Construction: $ 2i!�>� , REC c:NC>OlVE®
Proposed construction is for: X Residential Use _Commercial Use .J Z005
i�N 4`I
Name of Business:
OWN OF
UEENSBURY
If proposed construction is an addition,what will use of new addition bed
T BUILDING O AND OODE
New Addition Alteration Proposed Construction lst Floor 2nd floor Other Total Proposed
structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height
Ft.&.in.
Sin ale-Family Dwelling 1 -7 Kc,0-7
Two-Family Dwelling
Townhouse
Multifamily Dwelling
Number of Units:
Office
Mercantile
Manufacturing
Other:
Attached Garage 1 2, 3
Type of Heating System: Electric, Oil, Gas, Wood, orced Hot Ai , Baseboard, Other:
Is a fireplace and/or woodstove being installed, please refer to a separate application. X Yes _No
Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review.
The Building and Codes Office will allow commencement of your proposed project only after
issuance of your permit.
Declaration: Please sign below after you have carefully read the statement:
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that aii provisions of the Building Codes, The Zoning Ordinance, and all other laws pertaining to the
Proposed work shall de complied with,whether specified or noted, and that such work is authorized by the owner.
Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a
licensed surveyor, drawn to scale, showing actual location of all new c nstruction
Date: SO AID Applicant/Builder Signature: _.A�
The application of dated is hereby approved and
permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set
forth above.
Date: fz-z- D Authorized Signature: -1
L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Appiication.doc V:12/14/04
Che-A Residential Plan Review: One& Two Family Dwellings
/N%N/A
(2)Full sets of plans
tu
Over 1,500 sq. ft.—Stamped
Design Loads On Plans:90 Wind Floor Loads 40 psf
70 Ground Snow Load SIeeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
in 10'Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
k Winder Run and Rise t
Spiral Not Allowed From 2 Story
►l Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY
(518)761-8205
Application for Fuel Burning Appliances & Chimneys
applicable to solid fuel & vented gas appliances
f �,
Date --7
-- ^� , 20 , Permit NoO5
_1_0
Application is hereby made to the Building& Codes Office,for the issuance of a Building and Use
Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner
agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises,to perform required inspections.
NOTE to applicant: Rough-in and Final Inspections are required.
Applicant Information Fuel Burning Appliance Information
(circle appropriate words)
Name: 7 H t p s t^U Stove: wood coal pellet gas
4irieplace,
Ere
ace insert
ace, factory-built- wood as
Address: J(.�_t-.�t tC �_.�i t�y �t T`�t'l�yE ��.,.7
masonry: wood gas
Furnace: wood gas oil
Phone: rt - t��=�1 t -
If non-masonary applicance, please provide
Owner: Manufacturer Nome:
Address: Model Number:
Chimney Information ..,.,. -
Phone: (circle appropriate words)
Masonry block brick stone
Flue the (stee size: inches
Exact Address:
of construction or installation Factory-Built
Manufacturer name:
Model Number:
Note: Listed By: Number:___
Construction/Installation must
conform to NYS Fire Prevention &Building Indicate(circle) chimney material:
Code. Consult available Town of Queensbury
Handouts regarding required inspections. Double wall / Triple i+-all / Insulated / Direct venting
Chimney Liner
i l7a�ctii�z-',�r]7�paraEm�t—T'o�rra o.P Qu�e�s�i�-y�.1V"�e�-Yorl�-- --
i
Fire. Marshal Code# $Collected $Rcjrnded Received from (refunded to):
address: -- — - ---
A 173 3389 (190) Public Safety = '5
A 233 2655 (230�)Minor Sales
DATE:
White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / Pink&Goldenrod(Cashier's Dept.)
Application for Permit-Septic Disposal System
Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256
1. OWNER INFORMATION: ..._................................._...................... ............_.... ..._.................................,
Office Use
Location of installation: �O G �r*PAU-e `--h44S
File Permit No.
Tax Map No.
FeePaid.... ...................-................ .... ... .
Owner's Name: 1 HE tA1 U-t P.EtS o..:i' 1
Address: 1 C� i?:�.A c-�LS•t►- 'F �Q tVt , M A,i�A
2. INSTALLER'S NAME : PHONE NO.
3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of
bedrooms with applicable gallons per bedroom to equal total daily flow)
Year of House: No. of Bedrooms x Computation = Total Daily aow
1980 or older x 150 gal/bdrm =
1980—1991 x 130 gal/bdrm =
1991 —present x 110 gal/bdrm. =
Garbage Grinder Installed yes_ f no
Spa or Hot Tub Installed yes_ / no
4: PARCEL INFORMATION: (circle applicable information&indicate measurements)
T22ograRhy SoiL.Nature Ground Water Bedrock or Itn ervious Material Domestic Water Supply
lat 4 an at w� at depth at wh t depth unicipa
Rolling loam I , feet feet we
S e top slope clay of well;water supply
�%slope other from any septic-system
depth: absorption is ft.
other
Percolation Test: (To be completed by licensed professional engineer or architect)
Rate: minute per inch '
5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed
professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size
of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub.
Septic Tank: 1 5r0l ' gallon(min. size 1,000 gal)
Tile Field: each trench C> ft. Total System Length: Z 5O ft. fECEIVED
Seepage Pit(s): number of size ofeach: ft. by
Size of Stone to be used: # A / depth or thickness feet
TOWN OF OUEENSBURY
Bed System Size: rf- x BUILDING AND CODE
Alternative System: &x, length and/or size
6. HOLDING TANK SYSTEM: (if required)
Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons
Note: Alarm System and associated electrical work must be inmecte_.ci by a Tomes+ approved
electrical inspection agency.
7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read)
For your protection,please note that pursuant to Section 136-29 of the Code of the Town
of Queensbury,any permit or approval granted which is based upon or is granted in
reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and agree to abide by these and all
requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
Signatur f responsible person Date
• . ' ,'l'owit Of (Itts-milabui•y
►Sr�vrrs nild SCW1,4'. : Msvos-al t:I�:ij�it•i•
. Appond' ' C.
r
AVISt)RP ION, IrIIt;I�i•�
1
powD
as
r� � -ram.. �..••r���Y .-•• 'y_.�
G
Sv rt tc.
i t .1 •� tAI.ry
U16, 1142.1 lit III
• t�Y3r,R1►tx,�
- iMM
•-o.I•-•--•.ter•►•
,gym,...-----4 ROM) •..•.�,--"�-'"""�^'�_
M
7• SIGNATURE &INFORMATION F==rVN;SW1.r-*' \'��W4��+awv P ;: :•"::
L`�4'1Vl`I
I^
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12904
761-8205/761-8206
fax 745-4437
FactorlBuilt Gas Fireplace/Stave Inspection Reuort
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or s ecificationp is allowed /
Permit# i / Schedule Inspection l 1 Time am pm anytime Inspector� ✓
Name �h��� �C { C-1� y Address C�`U{/JG� L/0 Rough In Final
Appliance Manufacturer _ Model#
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve
Combustion Air
Hearth Extension(if any)
Mantel
Height above f/p opening
Witness Operation
Tank Placement(if LP)
White^Bdidin; � 1 eilow Cat r Pink-Fire Marsha!
Queensbury Building & Code Enforcement - Residential Final InspectioR-�s�
Office No.(518)761-8256 /L�'//� Arrive: am/ m epart ' �a3Npm
Date Inspection request received: ' ! -/ li Inspector's Initials: _
NAME: OA. UL�,A k Gr` G PERMIT#: I t
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments
Ye No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy!trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed pro er1
Gas Logs in Sealed or lag Enclosure
Final Electrical
Final Survey Plot Pl
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form—revised—I 00405.doc
` .
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
NAME:
LOCATION l 7
PERMIT
Final Survey Plot Plan_
AnDroved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey has b
Crai Bro Aoning Administrator
Notes:
L:\SueHemingwayIBuilding.Codes.Inspection.FORMS\Fina1 Survey
Zoning Administrator.doc
MAP REFEREN
CE: J
QUINCY LANE 5UBDN1510N
THE MICHALE5 GROUP
BYs VAN DU5EN + 5TEVE5
DATED• APRIL 15. 2003
LAST REVI5EDI JUNE 10. 2003
S 26�0
.pp
LOT 18
9�st 9
`� 1S p p
�O N
UTILITIES
cy
2 STORY
WOOD FRAMED
HOUSE
A5FHALT
DRIVE
o-6
LOT 17 73.68
1.01 acres
rs 44,009 sq.ft.
N670 u?
s ,
pp4�L CO
V• `V/
C. LOT 16
\ �v
oo ,
/ls,
Z
(0 QUtwcv {
EIVED �-
NOV 0 2 20
I
N'•'0 ��I T BU N OF ENS y -
�SO�y, FILE
COPY
LDIN AND CODE '�'�� �l50135
LAND
Date, OZMBER 28-,--2005
Dus ,e Map of a Survey made for Scate 1'=30'
..( 'UN EAFW NIgD Al1EN L N qt AOOYAON TO A SURVEY
NAP�AIIIW A 11G475tD 1N70 SURVEYORS SFAL i5 A
NdA"of WC""M Sys-0r,00M z of TK
Wo YM VAX ED=MW LAW
Steves MM GAPES FR011 TIE ORK7NK OF TNIS SURVEY S NARREv wTN M oRioula of THE IAHD aIR►eYDRs �J
�;MUTAMBE C"Dm"0BE" `° • THE MICHAELS GROUP
CmfiTGTKYNS YdCA7FD HFREDtt=on THAT
TIAS&RVEY WAS MMMM N AWMANCE"W
Land Surveyors BYftMEWV STAIX`M" M
er THE ATEW raac STATE A590dATR711 a PRofES90NAM
LAIe%WAY=SAD CERIEICAi1W5 SHAM RUN O LY
TD TIE PoASW idt Midi THE SIRYEY IS PREPARED.AND
oN HIS BMAF m DE lu cown".GamsE7m Town of Queensbury, Warren County, New York
AGENCY AND IGNiomw0 NsnTunRN usTm NEIEDN,AND MIGHAELS GROUP
169 Haviland Road Queensbury, New York 12804 TDIE ASS T = TIE ir►oua NsnTBTNxM•
N0. DATE DESCRIPTION DWG. No. 02333-17
(518) 792--8474 New York Lie. No. 50135
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ De rt: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initial
NAME: \\\ C C • ` PERMIT#: �� 1
LOCATION: ( INSPECT ON: — 0_�(
TYPE OF STRUCT L.�
Framing Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w) 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
F' topping \ r ✓" o r
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side Yz inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
GA-5 1--1 )0& 1 //,/ r ltno
RGK- PLL)L""F=,
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #: ' � -
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation Residential Check Commercial Check
Proper Vent Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed ro erl / No duct to e
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
0� w
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Gee PERMIT #: ��✓ ��
LOCATION: C, �t�vct, (�� INSPECT ON: 6 to
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates 4no__fDe—&�
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size Pp_
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Z
sure Test
ter Supply Piping
/ Head
P.S.I for 15 minutes
Insulation Residential Check Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
uct work sealed ro erl / No duct to e
COMMENTS: e pe't/,(f.5 Pc-,x
Lr,jC 5 k,?-� A-12 G�✓� �rZ
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: /,-, GJ
Queensbury Building & Code Enforcement Arrive: am/ Depart: Z,47J am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: �`"fIG � PERMIT #: &e)
LOCATION /7 ��� �� INSPECT ON: l�
TYPE OF STRUCTURE:
Y N N/A
4D,PIumbin
s h Plumbing / Nail Plates v�
N sT�
I
Vent / Vents in Place �RALi'A)
1 1/2 inch minimum Drain Size d-"
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head y STv >
50 P.S.I for 15 minutes 61 "`� �Ae
nsu at on Residential Check/ Commercial Check
IrMp—e—r—Vent, Attic Vent
Duct / Hot Water Piping Insulation
g
ired unheated s aces
tion Air Su I for Furnace
rk sealed i)rnnprlv / No duct to e
COMMENTS: L�,c�C S �C-,4'!Q �j j)/2
L tA)C
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: amV, art: am/pm '�
742 Bay Road, Queensbury,NY 12804 Inspector's Initial
I
NAME: C, PERMIT#:
l
LOCATION: INSPECT ON:
TYPE OF STRUCT
Y N N/A COMMENTS
aming
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams Cp tl C�- Cj'rjQ Sie1�Gt,�
Exterior sheeting nailed properly (, A- L I AJG�
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2 w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
restopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side Vz inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
i
5
�
.. �. � Iry �,,��-sr� b��F����N
�Gt-DV�22 � *406,3z06M
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: '
Queensbury Building & Code Enforcement Arrive: am/p De art: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Gam'. PERMIT #:
LOCATION: �2 (:a)UI/oc L LA) INSPECT ON: q1i 5
TYP OF STRUCTURE:
Y N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing / Firestopping Inspection Report J
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pmp art: LL am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
/�� j
NAME: �AA K lJ PERMIT#:
LOCATION: U(0 c. L.Z ��(7 INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMME
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z w) 16 gauge 8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/p
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: v PERMIT #:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N/A
ou h Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
D iin / Vent
7 ir
/ Head
P.S.I. or 10 ft. above highest connection for 15 minutes
�ressure Test
Wate ly Piping
it ead
or 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Septic Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: an/pm Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: G�' PERMIT NO.: C)S—
LOCATION: INSPECT ON:
RECHECK: '�-
Comments and/or diagram
Soil T <�/ la
Type of Water: l/Well Water
Waterline separation distance ft.
Well separation distance _ ft.
Other wells: ft.
Absorption Field: Total length '2 ft.
Length of each trench ft.
Depth of trenches Z ft.
Size of Stone Z
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building to tank t
Tank to Distribution Box
Distribution Box IQ Field/Pit i
Opening Sealed-
End Cape
Location/Separations
Foundation to tank t Ift.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan Y N
Engineer Report and As-Built Y N
Location of System on Property:
Front Rear eft Side < i t Sid
Middle Front Middle Rear
System Use S Zus:
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved
Last revised 116105
C tI
Rough Plumbing / Insulation Inspec eport
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #:
LOCATION: INSPECT ON: -j
TYPE OF STRU RE:
Y /A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressu Test
D n / Vent
/ Head
P.S.I. or 10 ft. above highest connection for 15 minutes
essure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation Residential Check/ Commercial Check _
Proper Vent Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Wbiting\Building&Codes\lnspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing/ Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depa m
742 Bay Road,Queensbury,NY 12804 Inspector's Initials
� /NAME: Ga—MLAnPERMIT#: 1
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COM TS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
R-P-
Bracing/Bridging cil
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/a w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
An or Bolts 6 ft.or less on center
I and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: a-�J
Aa— -S
Queensbury Building&Code Enforcement Arrive: am/pm Depart. ? am/pm III
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:AAA
NAME: Mgt GWS l./ PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z w 16 gauge 8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
16e and water shiel '24 inches from wall ----
Fire separation 1, 2, 3 hour > �+
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side `/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: '
Queensbury Building&Code Enforcement Arrive: am/p n �� Depart: ari' p
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: �\` \� PERMIT#: —
LOCATION: INSPECT ON:
TYPE OF STRUCT E:
Comments
Y TN N/A---
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing T
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 n4jVoly for wet areas under slab
_Aae ><ll Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft. -4
L:\SueHemingwaylBuilding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
t.
f
l
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p De art: m/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _
NAME: VVAPERMIT#: _ Ll
LOCATION: INSPECT ON: _
TYPE OF STRUCTURE:
Comments
---�� Y N/A
ootings
Piers
Monolithic Slab
Reinforcement in Place-?_—
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement I
of the concrete. I
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
1
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:1SueHemingway\I3uil ding.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003
Rough Plumbing / Insulation Inspection Report
t
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: _ ` am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #: a�- AAk,
LOCATION: l INSPECT ON:
TYPE OF STR CTURE:
Y 74
N N/A
ou h Plumbing / N it Plates
Plumbin Ven ents in Place ~
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet change of direction
Pr Test
in / ent
it ead
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation Residential Check / Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005
Permit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
Data filename:F:\SHARE\Design\Energy Calc\Quincy Lane\6 Quincy.rck RECEIVED
TITLE: QL544 Jefferson
COUNTY:Warren TOWN OF QUEENSBURY
STATE:New York BUILDING AND CODE
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE:06/03/05
DATE OF PLANS:June 3,2005
PROJECT INFORMATION:
6 Quincy Lane
Queensbury,N.Y.
COMPANY INFORMATION:
The Michaels Group
10 Blacksmith Dr.
Malta,N.Y. 12020
NOTES:
Custom Jefferson w/Cantilever @ Second Floor&Sun Room
Pella Proline windows
COMPLIANCE:Passes
Maximum UA=709
Your Home UA=539
24.0%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Raised or Energy Truss 1604 30.0 0.0 51
1st Floor walls:Wood Frame, 16"o.c. 2050 19.0 0.0 102
2x Family(BB):Wood Frame,Double Pane with Low-E 32 0.340 11
lx Family(AV):Wood Frame,Double Pane with Low-E 23 0.340 8
lx Brkfst(BC):Wood Frame,Double Pane with Low-E 31 0.340 11
2x opt.Brkfst(AR):Wood Frame,Double Pane with Low-E 21 0.340 7
Ix Brkfst(AP):Wood Frame:Double Pane with Low-E 14 0.340 5
Ix Back Hall(AP):Wood Frame:Double Pane with Low-E 14 0.340 5
2x Sunroom(AV):Wood Frame:Double Pane with Low-E 46 0.340 16
4x Sunroom(EG):Wood Frame:Double Pane with Low-E 41 0.340 14
Mud#20: Solid 19 0.240 5
lx Dining(BB):Wood Frame,Double Pane with Low-E 16 0.340 5
2x Dining(AR):Wood Frame,Double Pane with Low-E 21 0.340 7
Foyer#113: Solid 37 0.350 13
lx Living(BC):Wood Frame,Double Pane with Low-E 31 0.340 11
lx Pwdr rm. (N):Wood Frame,Double Pane with Low-E 6 0.340 2
2nd Floor walls:Wood Frame, 16"o.c. 1791 19.0 0.0 96
3x Mbr(BB):Wood Frame:Double Pane with Low-E 48 0.340 16
3x Bed#4(Z):Wood Frame,Double Pane with Low-E 14 0.340 5
lx Bed#4(BC):Wood Frame:Double Pane with Low-E 31 0.340 11
Ix Bed#3 (BC):Wood Frame,Double Pane with Low-E 31 0.340 11
lx Bed#2(BC):Wood Frame,Double Pane with Low-E 31 0.340 11
lx Foyer(AE):Wood Frame,Double Pane with Low-E 14 0.340 5
lx Mbath(AT):Wood Frame,Double Pane with Low-E 14 0.340 5
Basement Wall 1:Solid Concrete or Masonry 1538 0.0 11.0 99
Wall height:7.5'
Depth below grade: 6.5'
Insulation depth: 6.0'
Bsmnt windows:Wood Frame,Double Pane with Low-E 10 0.560 6
Floor @ MBR Cantilever:
All-Wood Joist/Truss:Over Outside Air 43 30.0 0.0 1
Furnace 1:Forced Hot Air,92 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they atte ing that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in co plia e t is Code.
Builder/Designer Date b 3 e5
REScheck Inspection Checklist
• New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
DATE:06/03/05
TITLE:QL544 Jefferson
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
[ ] 1. 1st Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ ] 2. 2nd Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.5' ht/6.5'bg/6.0' insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
Windows:
[ ] 1. 2x Family(BB):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 2. lx Family(AV):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 3. lx Brkfst(BC):Wood Frame,Double Pane with Low-E,U-factor: 0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ J Yes[ ]No
Comments:
[ ] 4. 2x opt.Brkfst(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 5. lx Brkfst(AP):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ J Yes [ ]No
Comments:
[ ] 6. lx Back Hall(AP):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] ( 7. 2x Sunroom(AV):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ) 8. 4x Sunroom(EG):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes( ]No
Comments:
[ ) 9. lx Dining(BB):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 10. 2x Dining(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 11. lx Living(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ )Yes[ ]No
Comments:
[ ] 12. lx Pwdr rm. (N):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 13. 3x Mbr(BB):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 14. 3x Bed#4(Z):Wood Frame,Double Pane with Low-E,U-factor: 0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 15. lx Bed#4(BC):Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 16. lx Bed#3(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 17. lx Bed#2(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 18. 1x Foyer(AE):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 19. lx Mbath(AT):Wood Frame,Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 20. Bsmnt windows:Wood Frame,Double Pane with Low-E,U-factor:0.560
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
Doors:
[ ] 1. Mud#20: Solid,U-factor:0.240
Comments:
[ ] 2. Foyer#1B: Solid,U-factor: 0.350
Comments:
Floors:
[ ] { 1. Floor @ NOR Cantilever:All-Wood Joist/Truss:Over Outside Air,
{ R-30.0 cavity insulation
{ Comments:
{
{ Heating and Cooling Equipment:
[ ] { 1. Furnace 1:Forced Hot Air,92 AFUE or higher
{ Make and Model Number
{
{ Air Leakage:
[ ] { Joints,penetrations,and all other such openings in the building envelope that are sources of air
{ leakage must be sealed.
[ ] { Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
{ with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
{ 3"clearance from insulation.
{
Vapor Retarder:
[ ] { Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
{ Materials Identification:
[ ] { Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] { Materials and equipment must be identified so that compliance can be determined.
[ ] { Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] { Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
{ the building plans or specifications.
{
{ Duct Insulation:
[ ] { Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] { Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] { Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] { Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
{ Insulation is not required on return ducts in basements.
{
{ Duct Construction:
[ ] { All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
{ (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
{ Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
{ operating at less than 2 in.w.g. (500 Pa).
[ ) { Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] { Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] { Air filters are required in the return air system.
[ ] { The HVAC system must provide a means for balancing air and water systems.
{
{ Temperature Controls:
[ ] { Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
{ temperature set point of the largest zone.
{
Electric Systems:
[ } { Separate electric meters are required for each dwelling unit.
{
{ Fireplaces:
[ ] { Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] { Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
{ provisions of the Building Code of New York State ,the Residential Code of New York State or
{ the New York City Building Code ,as applicable.
{
{ Service Water Heating:
[ ] { Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
{ water heater has an integral heat trap or i
s,part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ) Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range( 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)