Loading...
2005-414 TOWN OF QUEENSBURY FILE COPY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050414 Date Issued: Tuesday, November 15, 2005 This is to certify that work requested to be done as shown by Permit Number P20050414 has been completed. Tax Map Number: 523400-315-010-0001-017-000-0000 Location: 6 QUINCY Ln Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF Q EENSBURX Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050414 Application Number: A20050414 Tax Map No: 523400-315-010-0001-017-000-0000 Permission is hereby granted to: MICHAELS GROI TP LLC TUR For property located at: 6 QUINCY Ln in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALTA, NY 12020-0000 Garage-2 Cars Attached Single Family Dwelling $281,900.00 Total Value $281,900.00 Contractor or Builder's Name /Address Electrical Inspection Agency MICHAELS GROITP SUITE 1 10 BLACKSMITH Dr MALTA. NY 12020 Plans&Specifications 2005-414 LOT #17 HSE#6 QUINCY LANE 3383 SQ FT SINGLE FAMILY DWELLING $460.16 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, June 30, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated the T o sb ursday, June 30, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Permit No. Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 4-2-5�CtD 742 Bay Road,Queensbury,NY 12804 Recreation Fee A� y -622 Dave Hatin,Director codesQaueensburv.net Phone: (518)761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subiect to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder M`c-"atLZ GrzjtvF Owner: S � Address: iC> 13�LVS AIJIA VlZtyr-- , NaL"M Address: Home Phone: ep%9- co31 I Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: J-OKN-f L-0C.ASC-10 -'VRC%SE .rr tAAt,.,04ICZ Address: Phone 165-1 - 3144 Location of proposed construction: Lot No. Legal Address: Tax Map Number:_, n �'� "—� / Subdivision Name: Estimated Cost of Construction: $ 2i!�>� , REC c:NC>OlVE® Proposed construction is for: X Residential Use _Commercial Use .J Z005 i�N 4`I Name of Business: OWN OF UEENSBURY If proposed construction is an addition,what will use of new addition bed T BUILDING O AND OODE New Addition Alteration Proposed Construction lst Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height Ft.&.in. Sin ale-Family Dwelling 1 -7 Kc,0-7 Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1 2, 3 Type of Heating System: Electric, Oil, Gas, Wood, orced Hot Ai , Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. X Yes _No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that aii provisions of the Building Codes, The Zoning Ordinance, and all other laws pertaining to the Proposed work shall de complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new c nstruction Date: SO AID Applicant/Builder Signature: _.A� The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: fz-z- D Authorized Signature: -1 L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Appiication.doc V:12/14/04 Che-A Residential Plan Review: One& Two Family Dwellings /N%N/A (2)Full sets of plans tu Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load SIeeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise k Winder Run and Rise t Spiral Not Allowed From 2 Story ►l Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances f �, Date --7 -- ^� , 20 , Permit NoO5 _1_0 Application is hereby made to the Building& Codes Office,for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises,to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: 7 H t p s t^U Stove: wood coal pellet gas 4irieplace, Ere ace insert ace, factory-built- wood as Address: J(.�_t-.�t tC �_.�i t�y �t T`�t'l�yE ��.,.7 masonry: wood gas Furnace: wood gas oil Phone: rt - t��=�1 t - If non-masonary applicance, please provide Owner: Manufacturer Nome: Address: Model Number: Chimney Information ..,.,. - Phone: (circle appropriate words) Masonry block brick stone Flue the (stee size: inches Exact Address: of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number:___ Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wall / Triple i+-all / Insulated / Direct venting Chimney Liner i l7a�ctii�z-',�r]7�paraEm�t—T'o�rra o.P Qu�e�s�i�-y�.1V"�e�-Yorl�-- -- i Fire. Marshal Code# $Collected $Rcjrnded Received from (refunded to): address: -- — - --- A 173 3389 (190) Public Safety = '5 A 233 2655 (230�)Minor Sales DATE: White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / Pink&Goldenrod(Cashier's Dept.) Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: ..._................................._...................... ............_.... ..._................................., Office Use Location of installation: �O G �r*PAU-e `--h44S File Permit No. Tax Map No. FeePaid.... ...................-................ .... ... . Owner's Name: 1 HE tA1 U-t P.EtS o..:i' 1 Address: 1 C� i?:�.A c-�LS•t►- 'F �Q tVt , M A,i�A 2. INSTALLER'S NAME : PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily aow 1980 or older x 150 gal/bdrm = 1980—1991 x 130 gal/bdrm = 1991 —present x 110 gal/bdrm. = Garbage Grinder Installed yes_ f no Spa or Hot Tub Installed yes_ / no 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) T22ograRhy SoiL.Nature Ground Water Bedrock or Itn ervious Material Domestic Water Supply lat 4 an at w� at depth at wh t depth unicipa Rolling loam I , feet feet we S e top slope clay of well;water supply �%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch ' 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 1 5r0l ' gallon(min. size 1,000 gal) Tile Field: each trench C> ft. Total System Length: Z 5O ft. fECEIVED Seepage Pit(s): number of size ofeach: ft. by Size of Stone to be used: # A / depth or thickness feet TOWN OF OUEENSBURY Bed System Size: rf- x BUILDING AND CODE Alternative System: &x, length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inmecte_.ci by a Tomes+ approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signatur f responsible person Date • . ' ,'l'owit Of (Itts-milabui•y ►Sr�vrrs nild SCW1,4'. : Msvos-al t:I�:ij�it•i• . Appond' ' C. r AVISt)RP ION, IrIIt;I�i•� 1 powD as r� � -ram.. �..••r���Y .-•• 'y_.� G Sv rt tc. i t .1 •� tAI.ry U16, 1142.1 lit III • t�Y3r,R1►tx,� - iMM •-o.I•-•--•.ter•►• ,gym,...-----4 ROM) •..•.�,--"�-'"""�^'�_ M 7• SIGNATURE &INFORMATION F==rVN;SW1.r-*' \'��W4��+awv P ;: :•":: L`�4'1Vl`I I^ Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12904 761-8205/761-8206 fax 745-4437 FactorlBuilt Gas Fireplace/Stave Inspection Reuort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or s ecificationp is allowed / Permit# i / Schedule Inspection l 1 Time am pm anytime Inspector� ✓ Name �h��� �C { C-1� y Address C�`U{/JG� L/0 Rough In Final Appliance Manufacturer _ Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White^Bdidin; � 1 eilow Cat r Pink-Fire Marsha! Queensbury Building & Code Enforcement - Residential Final InspectioR-�s� Office No.(518)761-8256 /L�'//� Arrive: am/ m epart ' �a3Npm Date Inspection request received: ' ! -/ li Inspector's Initials: _ NAME: OA. UL�,A k Gr` G PERMIT#: I t LOCATION: DATE: TYPE OF STRUCTURE: Comments Ye No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy!trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed pro er1 Gas Logs in Sealed or lag Enclosure Final Electrical Final Survey Plot Pl As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form—revised—I 00405.doc ` . Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: LOCATION l 7 PERMIT Final Survey Plot Plan_ AnDroved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has b Crai Bro Aoning Administrator Notes: L:\SueHemingwayIBuilding.Codes.Inspection.FORMS\Fina1 Survey Zoning Administrator.doc MAP REFEREN CE: J QUINCY LANE 5UBDN1510N THE MICHALE5 GROUP BYs VAN DU5EN + 5TEVE5 DATED• APRIL 15. 2003 LAST REVI5EDI JUNE 10. 2003 S 26�0 .pp LOT 18 9�st 9 `� 1S p p �O N UTILITIES cy 2 STORY WOOD FRAMED HOUSE A5FHALT DRIVE o-6 LOT 17 73.68 1.01 acres rs 44,009 sq.ft. N670 u? s , pp4�L CO V• `V/ C. LOT 16 \ �v oo , /ls, Z (0 QUtwcv { EIVED �- NOV 0 2 20 I N'•'0 ��I T BU N OF ENS y - �SO�y, FILE COPY LDIN AND CODE '�'�� �l50135 LAND Date, OZMBER 28-,--2005 Dus ,e Map of a Survey made for Scate 1'=30' ..( 'UN EAFW NIgD Al1EN L N qt AOOYAON TO A SURVEY NAP�AIIIW A 11G475tD 1N70 SURVEYORS SFAL i5 A NdA"of WC""M Sys-0r,00M z of TK Wo YM VAX ED=MW LAW Steves MM GAPES FR011 TIE ORK7NK OF TNIS SURVEY S NARREv wTN M oRioula of THE IAHD aIR►eYDRs �J �;MUTAMBE C"Dm"0BE" `° • THE MICHAELS GROUP CmfiTGTKYNS YdCA7FD HFREDtt=on THAT TIAS&RVEY WAS MMMM N AWMANCE"W Land Surveyors BYftMEWV STAIX`M" M er THE ATEW raac STATE A590dATR711 a PRofES90NAM LAIe%WAY=SAD CERIEICAi1W5 SHAM RUN O LY TD TIE PoASW idt Midi THE SIRYEY IS PREPARED.AND oN HIS BMAF m DE lu cown".GamsE7m Town of Queensbury, Warren County, New York AGENCY AND IGNiomw0 NsnTunRN usTm NEIEDN,AND MIGHAELS GROUP 169 Haviland Road Queensbury, New York 12804 TDIE ASS T = TIE ir►oua NsnTBTNxM• N0. DATE DESCRIPTION DWG. No. 02333-17 (518) 792--8474 New York Lie. No. 50135 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ De rt: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: \\\ C C • ` PERMIT#: �� 1 LOCATION: ( INSPECT ON: — 0_�( TYPE OF STRUCT L.� Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w) 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour F' topping \ r ✓" o r Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade GA-5 1--1 )0& 1 //,/ r ltno RGK- PLL)L""F=, Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: ' � - LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed ro erl / No duct to e COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 0� w Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Gee PERMIT #: ��✓ �� LOCATION: C, �t�vct, (�� INSPECT ON: 6 to TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates 4no__fDe—&� Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Pp_ Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Z sure Test ter Supply Piping / Head P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace uct work sealed ro erl / No duct to e COMMENTS: e pe't/,(f.5 Pc-,x Lr,jC 5 k,?-� A-12 G�✓� �rZ LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: /,-, GJ Queensbury Building & Code Enforcement Arrive: am/ Depart: Z,47J am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �`"fIG � PERMIT #: &e) LOCATION /7 ��� �� INSPECT ON: l� TYPE OF STRUCTURE: Y N N/A 4D,PIumbin s h Plumbing / Nail Plates v� N sT� I Vent / Vents in Place �RALi'A) 1 1/2 inch minimum Drain Size d-" Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head y STv > 50 P.S.I for 15 minutes 61 "`� �Ae nsu at on Residential Check/ Commercial Check IrMp—e—r—Vent, Attic Vent Duct / Hot Water Piping Insulation g ired unheated s aces tion Air Su I for Furnace rk sealed i)rnnprlv / No duct to e COMMENTS: L�,c�C S �C-,4'!Q �j j)/2 L tA)C LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: amV, art: am/pm '� 742 Bay Road, Queensbury,NY 12804 Inspector's Initial I NAME: C, PERMIT#: l LOCATION: INSPECT ON: TYPE OF STRUCT Y N N/A COMMENTS aming Attic Access 22"x 30"minimum Jack Studs/Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Cp tl C�- Cj'rjQ Sie1�Gt,� Exterior sheeting nailed properly (, A- L I AJG� 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2 w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour restopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Vz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade i 5 � .. �. � Iry �,,��-sr� b��F����N �Gt-DV�22 � *406,3z06M Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building & Code Enforcement Arrive: am/p De art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Gam'. PERMIT #: LOCATION: �2 (:a)UI/oc L LA) INSPECT ON: q1i 5 TYP OF STRUCTURE: Y N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report J Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pmp art: LL am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: /�� j NAME: �AA K lJ PERMIT#: LOCATION: U(0 c. L.Z ��(7 INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMME Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: v PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N/A ou h Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test D iin / Vent 7 ir / Head P.S.I. or 10 ft. above highest connection for 15 minutes �ressure Test Wate ly Piping it ead or 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Septic Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: an/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: G�' PERMIT NO.: C)S— LOCATION: INSPECT ON: RECHECK: '�- Comments and/or diagram Soil T <�/ la Type of Water: l/Well Water Waterline separation distance ft. Well separation distance _ ft. Other wells: ft. Absorption Field: Total length '2 ft. Length of each trench ft. Depth of trenches Z ft. Size of Stone Z Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank t Tank to Distribution Box Distribution Box IQ Field/Pit i Opening Sealed- End Cape Location/Separations Foundation to tank t Ift. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear eft Side < i t Sid Middle Front Middle Rear System Use S Zus: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 116105 C tI Rough Plumbing / Insulation Inspec eport Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: INSPECT ON: -j TYPE OF STRU RE: Y /A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressu Test D n / Vent / Head P.S.I. or 10 ft. above highest connection for 15 minutes essure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Residential Check/ Commercial Check _ Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Wbiting\Building&Codes\lnspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depa m 742 Bay Road,Queensbury,NY 12804 Inspector's Initials � /NAME: Ga—MLAnPERMIT#: 1 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COM TS Framing Attic Access 22"x 30"minimum Jack Studs/Headers R-P- Bracing/Bridging cil Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/a w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses An or Bolts 6 ft.or less on center I and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: a-�J Aa— -S Queensbury Building&Code Enforcement Arrive: am/pm Depart. ? am/pm III 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:AAA NAME: Mgt GWS l./ PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center 16e and water shiel '24 inches from wall ---- Fire separation 1, 2, 3 hour > �+ Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side `/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building&Code Enforcement Arrive: am/p n �� Depart: ari' p 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: �\` \� PERMIT#: — LOCATION: INSPECT ON: TYPE OF STRUCT E: Comments Y TN N/A--- Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing T Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 n4jVoly for wet areas under slab _Aae ><ll Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. -4 L:\SueHemingwaylBuilding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 t. f l Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p De art: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _ NAME: VVAPERMIT#: _ Ll LOCATION: INSPECT ON: _ TYPE OF STRUCTURE: Comments ---�� Y N/A ootings Piers Monolithic Slab Reinforcement in Place-?_— The contractor is responsible for providing protection from freezing for 48 hours following the placement I of the concrete. I Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval 1 Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\I3uil ding.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report t Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: _ ` am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: a�- AAk, LOCATION: l INSPECT ON: TYPE OF STR CTURE: Y 74 N N/A ou h Plumbing / N it Plates Plumbin Ven ents in Place ~ 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pr Test in / ent it ead 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc Data filename:F:\SHARE\Design\Energy Calc\Quincy Lane\6 Quincy.rck RECEIVED TITLE: QL544 Jefferson COUNTY:Warren TOWN OF QUEENSBURY STATE:New York BUILDING AND CODE HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:06/03/05 DATE OF PLANS:June 3,2005 PROJECT INFORMATION: 6 Quincy Lane Queensbury,N.Y. COMPANY INFORMATION: The Michaels Group 10 Blacksmith Dr. Malta,N.Y. 12020 NOTES: Custom Jefferson w/Cantilever @ Second Floor&Sun Room Pella Proline windows COMPLIANCE:Passes Maximum UA=709 Your Home UA=539 24.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 1604 30.0 0.0 51 1st Floor walls:Wood Frame, 16"o.c. 2050 19.0 0.0 102 2x Family(BB):Wood Frame,Double Pane with Low-E 32 0.340 11 lx Family(AV):Wood Frame,Double Pane with Low-E 23 0.340 8 lx Brkfst(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 2x opt.Brkfst(AR):Wood Frame,Double Pane with Low-E 21 0.340 7 Ix Brkfst(AP):Wood Frame:Double Pane with Low-E 14 0.340 5 Ix Back Hall(AP):Wood Frame:Double Pane with Low-E 14 0.340 5 2x Sunroom(AV):Wood Frame:Double Pane with Low-E 46 0.340 16 4x Sunroom(EG):Wood Frame:Double Pane with Low-E 41 0.340 14 Mud#20: Solid 19 0.240 5 lx Dining(BB):Wood Frame,Double Pane with Low-E 16 0.340 5 2x Dining(AR):Wood Frame,Double Pane with Low-E 21 0.340 7 Foyer#113: Solid 37 0.350 13 lx Living(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Pwdr rm. (N):Wood Frame,Double Pane with Low-E 6 0.340 2 2nd Floor walls:Wood Frame, 16"o.c. 1791 19.0 0.0 96 3x Mbr(BB):Wood Frame:Double Pane with Low-E 48 0.340 16 3x Bed#4(Z):Wood Frame,Double Pane with Low-E 14 0.340 5 lx Bed#4(BC):Wood Frame:Double Pane with Low-E 31 0.340 11 Ix Bed#3 (BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Bed#2(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Foyer(AE):Wood Frame,Double Pane with Low-E 14 0.340 5 lx Mbath(AT):Wood Frame,Double Pane with Low-E 14 0.340 5 Basement Wall 1:Solid Concrete or Masonry 1538 0.0 11.0 99 Wall height:7.5' Depth below grade: 6.5' Insulation depth: 6.0' Bsmnt windows:Wood Frame,Double Pane with Low-E 10 0.560 6 Floor @ MBR Cantilever: All-Wood Joist/Truss:Over Outside Air 43 30.0 0.0 1 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they atte ing that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in co plia e t is Code. Builder/Designer Date b 3 e5 REScheck Inspection Checklist • New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:06/03/05 TITLE:QL544 Jefferson Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. 1st Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. 2nd Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.5' ht/6.5'bg/6.0' insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: [ ] 1. 2x Family(BB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 2. lx Family(AV):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 3. lx Brkfst(BC):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ J Yes[ ]No Comments: [ ] 4. 2x opt.Brkfst(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 5. lx Brkfst(AP):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ J Yes [ ]No Comments: [ ] 6. lx Back Hall(AP):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] ( 7. 2x Sunroom(AV):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ) 8. 4x Sunroom(EG):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes( ]No Comments: [ ) 9. lx Dining(BB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 10. 2x Dining(AR):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 11. lx Living(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ )Yes[ ]No Comments: [ ] 12. lx Pwdr rm. (N):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 13. 3x Mbr(BB):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 14. 3x Bed#4(Z):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 15. lx Bed#4(BC):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 16. lx Bed#3(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 17. lx Bed#2(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 18. 1x Foyer(AE):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 19. lx Mbath(AT):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 20. Bsmnt windows:Wood Frame,Double Pane with Low-E,U-factor:0.560 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: [ ] 1. Mud#20: Solid,U-factor:0.240 Comments: [ ] 2. Foyer#1B: Solid,U-factor: 0.350 Comments: Floors: [ ] { 1. Floor @ NOR Cantilever:All-Wood Joist/Truss:Over Outside Air, { R-30.0 cavity insulation { Comments: { { Heating and Cooling Equipment: [ ] { 1. Furnace 1:Forced Hot Air,92 AFUE or higher { Make and Model Number { { Air Leakage: [ ] { Joints,penetrations,and all other such openings in the building envelope that are sources of air { leakage must be sealed. [ ] { Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly { with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a { 3"clearance from insulation. { Vapor Retarder: [ ] { Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. { Materials Identification: [ ] { Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] { Materials and equipment must be identified so that compliance can be determined. [ ] { Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] { Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on { the building plans or specifications. { { Duct Insulation: [ ] { Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] { Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] { Supply ducts in unconditioned spaces must be insulated to R-11. [ ] { Return ducts in unconditioned spaces(except basements)must be insulated to R-2. { Insulation is not required on return ducts in basements. { { Duct Construction: [ ] { All joints,seams,and connections must be securely fastened with welds,gaskets,mastics { (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. { Exception:Continuously welded and locking-type longitudinal joints and seams on ducts { operating at less than 2 in.w.g. (500 Pa). [ ) { Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] { Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] { Air filters are required in the return air system. [ ] { The HVAC system must provide a means for balancing air and water systems. { { Temperature Controls: [ ] { Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space { temperature set point of the largest zone. { Electric Systems: [ } { Separate electric meters are required for each dwelling unit. { { Fireplaces: [ ] { Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] { Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction { provisions of the Building Code of New York State ,the Residential Code of New York State or { the New York City Building Code ,as applicable. { { Service Water Heating: [ ] { Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the { water heater has an integral heat trap or i s,part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ) Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range( 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)