ResCheck " 01 0 O RE•Scheck Software Version 4.6.3 v 12 g Co fy y coo , i( Compliance Ce o DEC a 7s ,, 3 < • C. a.) Project New Ranch Model F-11DEC0 6 j o v (n TOWN OF C�UE�9�l��L��1( Energy Code: 2015 IECCQUEENS BURY Location: Glens Falls, New York. BUILDING&CODES 0 x Construction Type: Single-family !y 4V Project Type: New Construction >y 0 OA Orientation: Bldg. faces 135 deg: from North- CDD y Conditioned Floor Area: 1,607 ft2 C31 taD Glazing Area 12% � O Climate Zone: 6 (7635 HDD) N�, l Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 45 Richmond Hill Drive David Howard Ethan Peter Hall WiltonQueensbury,NY 12804. 500 Luzerne Road. Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave. 518-361-0714 Glens Falls, NY 12801 518-741-0268, , ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 4.2%Better Than Code Maximum UA: 310 Your UA: 297. The/ Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1: Raised or Energy Truss 1,607 38.0 0.0 0.025 40 Wall 1:Wood Frame, 16 o.c. 626 21.0. 3.6 0.046 25 Orientation: Front Window 1:Wood Frame:Double Pane with Low-E 66 0.290 19 Orientation: Front Door 1: Solid 21 0.300 6 Orientation: Front Wall 2:Wood Frame, 16"o.c. 363 21.0 3.6 0.046 16 Orientation: Right side Window 2:Wood Frame:Double Pane with Low-E 8 0.290 2 Orientation: Right side Wall 3:Wood Frame,16"o.c. 626 21.0 3.6 0.046 22 Orientation: Back Window 3:Wood Frame:Double Pane with Low-E 102 0.290 30 Orientation: Back Door 2: Glass 40 0.320 13 Orientation: Back Wall 4:Wood Frame, 16"o.c: 363 . 21.0 3.6 . 0.046 16 Orientation: Left side Window 4:Wood Frame:Double Pane with Low-E 8 0.290 2 Orientation: Left side Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45.Richmond Hill.rck Page 1 of10 Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Door 3:Solid 18 0.300 5 Orientation: Left side Wall 5:Wood Frame, 16"o.c. 48 21.0. 3.6 0.046 1 Orientation: Right side Door 4: Glass 18 0.320 6 Orientation: Right side Wall 6:Wood Frame,16"o.c. 93 21.0 3.6 0.046 4 Orientation: Left side Basement Wall 1:Solid Concrete or Masonry 557 0.0 15.0 0.049 27 Orientation: Front Wall height: 8.9' Depth below grade: 7.0' Insulation depth:.8.5' Basement Wall 2:Solid Concrete or Masonry . 323 0.0 15.0 0.049 15 Orientation: Right side Wall height: 8.9' Depth below grade:7.0' Insulation depth:8.5' .Window 5:Wood Frame:Double Pane with Low-E 12 0.290 3 Orientation: Right side Basement Wall 3:Solid Concrete or.Masonry 557 0.0 15.0 0.049 27 Orientation:Back Wall height: 8.9'. . - Depth below grade: 7.0' . Insulation depth: 8.5' Basement Wall 4:Solid Concrete or Masonry 323 0.0 15.0 0.049 16 Orientation: Left side Wall height:8.9' Depth below grade: 7.0' Insulation depth:8.5' Window 6:Vinyl/Fiberglass;Frame:Double Pane with Low-E 6 0.290 2 Orientation: Left side Compliance Statement The proposed building.design described here is consistent with the building plans,specifications,and other calculations submitted wiith:the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory re quiren) isted in R check Inspection Checklist. Ethan Peter Hall=Architect t' `T, �3, iCtr‘2C.V.f Name-Title Signature z`:'' w ,-,,z- a``,N, Date / ems - t. v n;-* rfiv,,,„qa tv,,,,,) Project Title: New Ranch Model Report date: 12/06/19 Data filename:Y:\Howard Construction\45 Richmond Hill Drive\Construction.Dwgs\45.Richmond Hill.rck Page 2 of10 Li( REScheek Software Version 4.6.3 Inspection Checklist Energy Code 2015 IECC Requirements:.92.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and_ how that is documented, or that an exception is being.claimed. Where compliance is itemized.in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre=Inspection/Plan Review Complies? Comments/Assumptioris & Req.ID Value Value 103.1, 'Construction drawings and I❑Complies Requirement will be met. 103.2 ;documentation demonstrate: `❑Does Not [PR1]1 ;energy code compliance for the - Location on plans/spec:A- gj ;building envelope.Thermal ['Not Observable 1 envelope represented on : ONot Applicable construction documents. 103.1, ;Construction drawings and i❑Complies Requirement will be met.. 103.2; documentation demonstrate I❑Does Not 403.7 lenergy code compliance for f Location on plans/spec:A- [PR3]1 i lighting and mechanical systems. ❑Not Observable 1 co, :Systems serving multiple 11=INot Applicable ;dwelling units must demonstrate ;compliance with the IECC i Commercial.Provisions.. . q 302.1, 'Heating and cooling equipment is Heating: Heating: . ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu%hr Btu/hr DDoes Not [PR2]z on loads calculated per.ACCA Cooling: Cooling: Location on plans/spec:A- 8 ;Manual J or other methods ❑Not Observable 1 �J Btu/hr Btu/hr ❑Not Applicable approved by the code official. Pp i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill:rck Page 3 of10 Section • Plans Verified Field. Verified # Foundation:Inspection Complies? Comments/Assumptions &.Req.ID • Value . . Value . . 402.1.1 Conditioned basement wall R= . R- ❑Complies ' ;See the Envelope Assemblies [F04]1 1 insulation R-value.Where interior R_ R- Oboes Not ;table for values. insulation is used,verification ;may need to occur during ONot Observable Insulation.Inspection.:Not ONot Applicable required in warm-humid locations in Climate Zone 3. 303.2 ;Conditioned basement wall ❑Complies Requirement will be met: [F0511 insulation installed per ❑Does Not ,e ;manufacturer's instructions. Location on plans/spec:A ❑Not Observable 1 . ONot Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. •;8, ;distance from top of wall. .. ONot Observable ONot Applicable 303.2.1 ;A protective covering is installed ❑Complies Exception: Requirement is [F011]2 to.protect exposed exterior ❑Does Not not applicable. U insulation and extends a minimum of 6 in. below grade: ONot Observable ONot Applicable 403.9 i Snow-and ice-melting system ;❑Complies • Exception: Requirement is [F012]2 i controls installed: ,4 1❑Does Not not applicable. y - PP J ;. ONot Observable i❑Not Applicable Additional Comments/Assumptions:. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data.filename: Y:\Howard Construction\45 Richmond..Hill Drive\Construction Dwgs\45 Richmond Hill.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Complies? Comments/Assumptions &-.Req.ID Value Value. . . 402:1.1, ;Door U-factor. U-. U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRl]1 ['Not Observable ❑Not Applicable . 402.1.1, ;Glazing U-factor(area weighted U= U- ElComplies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6; DNot Observable 402.5 ONot Applicable [FR2i1 U 303.1:3 U-factors of fenestration products - ;❑Complies Requirement will be met. [FR4]1 are determined in accordance I❑Does Not ;9ji with the NFRC test procedure or i Location on plans/spec:A- taken from the default table. 2 Not Observable ;1 iONot Applicable 402.4.1.1 :Air barrier and thermal barrier I❑Complies Requirement will be met. [FR23]1 :installed per manufacturer's i❑Does Not instructions. I Location on plans/spec:A- to, {❑Not Observable 1 . I❑Not Applicable 402.4.3 :Fenestration that is not site.built I❑Complies Requirement will be met. [FR2O]1 ;is listed and labeled as meeting i❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ss or has infiltration rates perNFRC i I❑Not Observable 400 that do not exceed code . i I❑Not Applicable ;limits. I 402.4.5 i IC-rated recessed lighting fixtures I❑Complies Exception: Requirement is [FR16]2 f sealed at housing/interior finish ( ❑Does Not not applicable. and labeled to indicate<_2.0 cfrn ;leakage at 75 Pa. !❑Not Observable I ( iENot Applicable 403.2.1 :Supply and return ducts in attics ❑Complies [FR12j1 insulated >= R-8 where duct is j❑Does Not >_3 inches in diameter and >= e� ;R-6 where<3 inches;Supply and iIi {❑Not Observable return ducts in other portions of .1 i❑Not Applicable ;the building insulated >= R-6 for diameter>=3 inches and R-4;2 I I :for<3 inches in_diameter. S . •403.3.3.5 ;Building cavities are riot used as I ;❑Corrrplies Requirement will be met. [FR15]3 :ducts or plenums. I (❑Does Not J 1 C❑Not Observable location.on plans/spec:A- ; I❑Not Applicable 403.4 j HVAC piping conveying fluids R R- ❑Complies Requirement will be met. [FR17]2 :above 105°F or chilled fluids. ❑Does Not J ;below 55°F are insulated to>_R- Location on plans/spec:ser A- I3 ❑Not Obvable 1 . ❑Not Applicable 403.4.1 1 Protection of insulation on HVAC i ❑Complies Requirement will be met. [FR24]1 piping 4 ❑Does Not p, , Location on plans/spec:A- ❑Not.Observable 1 P ❑Not Applicable 403.5.3 ;Hot water pipes are insulated to R-` R- Complies [FR18]2 >_R-3. ODoes Not U ❑Not Observable _ ❑Not Applicable 403.6 (Automatic or gravity dampers are DComplies Requirement will be met. [FR1912 ;installed on all outdoor air - iODoes Not ;intakes and exhausts. C - I Location on plans/spec:A- `❑Not Observable 1 I ( 11=INot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45.Richmond Hill.rck Page 5 of 10 Additional Comments/Assumptions:_ 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact.(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill:rck Page 6 of10 Section Plans Verified Field Verified . # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ;❑Complies Requirement will be met. [IN1312 !or the installed R-values iDDoes Not provided. e ;❑Not Observable "❑Not Applicable 402.1.1, ;Wall insulation R-value. If this is a R= R- OComplies See the Envelope Assemblies es ;mass wall with at least 1/2 of the ❑ Wood 0.Wood ❑Does Not table for values: 402.2.6 ;wall insulation on the wall e . [['NW ;exterior,the exterior insulation ❑ Mass ❑ Mass ❑Not Observable r , ,requirement applies.(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 . . ,Wall insulation is installed per ❑Com; plies Requirement will be met. [IN4]1 manufacturer's instructions. DDoes Not. Location on plans/spec:•A- 1❑Not Observable 1 i❑Not Applicable . Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill.rck Page 7 of10 Section Plans Verified . . Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID Value' Value. . 402.1.1, 'Ceiling insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, j ❑ Steel ❑ Steel ❑ 402.2.E Not Observable [Flu]' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per f❑Complies Requirement will be met. 303.2 ;manufacturers instructions. ;Oboes Not [FI2]1 ;Blown insulation marked every f Location on plans/spec:A 300 ft2. f❑Not Observable 1 ❑Not Applicable 402.2.3 ;Vented attics with air permeable I k❑Complies Requirement will be met. [FI2212 insulation include baffle adjacent I ❑Does Not to soffit and eave vents that Location on plans/sPec:A- extends over insulation. I Not Observable 5 ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- ❑Complies [FI3]1 ;insulation>_ R-value of the Oboes Not ;adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [FI17]1 ;ach in Climate Zones 1-2,and ❑Does Not ;<=3 ach in Climate Zones 3.8. Location on plans/spec:A- ❑Not Observable 1 ❑Not Applicable. 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 DComplies Exception:All ducts and air [FI4]1 ;cfm/10,0 ft2 across the system or ft2 ft2 Oboes Not handlers are located within <=3 cfm/100 ft2 without air conditioned space. handler @ 25 Pa. For rough-in ❑Not Observable :tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air [FI27]1 ;determine air leakage with ft2 ft2 Oboes Not handlers are located within ;either Rough-in test:Total conditioned space. leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable ;w,g.across the system including ;the manufacturer's air handler ;enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch ;w.g.across the entire system ;including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ( ❑Complies Requirement will be met. [FI24]i by manufacturer at<=2%of ❑Does Not design air flow. I Location on plans/spec:A- 1❑Not Observable 1 I 1DNot Applicable 403.1.1 ;Programmable thermostats t ;❑Complies Requirement will be met. [FI9]2 ;installed for control of primary i 10Does Not ;heating and cooling systems and Location on plans/spec:A- I ;initially setby manufacturer to ❑Not Observable 1 code specifications. f I❑NotApplicable 403.1.2 ;Heat pump thermostat installed IDComplies Exception: Requirement is [F11012 on heat pumps. I❑Does Not not applicable. I I ;❑Not Observable 1❑Not Applicable 403.5.1 ;Circulating service hot water ; ;❑Complies Exception: Requirement is [FI11]2 ;systems have automatic or f 1❑Does Not not applicable. accessible manual controls. ' Not Observable ' ❑1DNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 3.2/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill:rck Page 8 of10 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;All mechanical ventilation system ; ;❑Complies Requirement will be met. [FI25]2 ;fans not part of tested and listed I I❑Does Not HVAC equipment meet efficacy Location on plans/spec:A- and air flow limits. ! Not Observable 1 ❑Not Applicable 403.2 ;Hot water boilers supplying heat j❑Complies Exception: Requirement is [F126]2 I through one-or two=pipe heating j❑Does Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ;❑Not Applicable • temperature. 403.5.1.1 'Heated water circulation systems ; ❑Complies Exception: Requirement is [FI28]2 have a circulation pump.The I ❑Does Not not applicable. system return pipe is a dedicated ;return pipe or a cold water supply Not Observable ;pipe. Gravity and thermos- j ENot Applicable ;syphon circulation systems are ;not present. Controls for circulating hot water system pumps start the pump with signal+` for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [FI29]2 !comply with IEEE 515.1 or UL ❑Does Not not applicable. 515.Controls automatically adjust the energy input to the ENot Observable `heat tracing to maintain the illINOt Applicable desired water temperature in the piping. f I 403.5.2 ;Water distribution systems that j I❑Complies Exception: Requirement is [F130]2 have recirculation pumps that I ;❑Does Not not applicable. pump water from a heated water ;❑Not Observable ;supply pipe back to the heated water source through a cold ;❑Not Applicable ;water supply pipe have a ;demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1042F. 403.5.4 Drain water heat recovery units ; i❑Complies Requirement will be met. [F131]2 tested in accordance with CSA I I❑Does Not B55.1. Potable water-side j Location on plans/spec:A- ;pressure loss of drain water heat i Not Observable 1 recovery units < 3 psi for I ENot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. j 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [F16]1 fixtures or 75%of permanent I❑Does Not fixtures have high efficacy lamps. j Location on plans/spec:A- Does not apply to low-voltage ❑Not Observable 1 lighting. IDNot Applicable 404.1.1 ;Fuel gas lighting systems have ;❑Complies Requirement will be met. [FI23]3 no continuous pilot light. '❑Does Not O '❑Not Observable Location on plans/spec:A- 1 I❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill.rck Page 9 of10 Section Plans Verified . Field Verified. # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID Value Value 401.3 ;Compliance certificate posted. ;❑.Complies Requirement will be met [FI7]2 i { ;❑Does Not I IONot Observable i ;❑Not Applicable 303.3 i Manufacturer manuals for jOComplies" Requirement will be met. [FI18]3 {mechanical and water heating }Oboes Not systems have been provided. i❑Not Observable ;❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Ranch Model Report date: 12/06/19 Data filename: Y:\Howard Construction\45 Richmond Hill Drive\Construction Dwgs\45 Richmond Hill.rck Page 10 of10 g, 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 24.60 Below-Grade Wall 15.00 Floor 0.00 Ceiling/ Roof. 38.00: Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door. 0.32: Heating&Cooling Equipment Efficiency Heating System: .Cooling System: Water Heater: . Name: Date: .. Comments