Loading...
Manual J Your Company Here... maynard construction harris job • Your Address Here... -City Here..., State Here..Zip Here... 20 knox rd Phone Here -Email Here... Sales Consultant: Job#: harris job Date: 09/01/2020 System 9 (Average Load Procedure) Design Conditions Location: Glens Falls AP, New York Elevation: 335 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 43° N Design Grains: 26 Summer: 92 72 Heated Area 992 Sq.Ft. Winter: -17 70 Cooled Area 992 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 1242 6800 . 742 0 Windows 68 2780 2331 0 Doors 0 0 0 0 Ceilings 416. 941 811 0 Skylights 0 0 0 0 Floors 992 1002 0 0 • Room Internal Loads 0 2400 0 Blower Load 1707 0 Hot Water Piping Load 0 0 0 I Winter Humidification Load 0 0 0 Infiltration 6408 753 605 _.-_.._....._... Approved ACCA Ventilation 3828 880 707 MJ8 Calculations Duct Loss/Gain EHLF=O ESGF=O 0 0 0 AED Excursion n/a 0 n/a Subtotal 21759 9624 1312 Total Heating 21759 Btuh Total Cooling 10936 Btuh 43 Linear ft. of Hydronic Baseboard *Calculations are based on the ACCA Manual J.8th Edition and are approved by ACCA.All computed calculations are estimates based on building use,weather data, and inputted values such as R-Values,window types,duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. Adtek AccuLoad Report Version 17.3.5 Page 1 ur Co ;paiy Here. maynard construction harris job Your Address Here... -City Here..., State Here..Zip Here... 20 knox rd Phone Here -Email Here... Sales Consultant: Job#: harris job Date: 09/01/2020 Equipment Selection Design Conditions Design Location: Glens Falls AP, New York Relative Humidity: 50% Elevation: 335 ft Summer Outdoor Design: 92 Latitude: 43° N Winter Outdoor Design: -17 Daily Range: Medium Summer Indoor Design: 72 Design Grains 26 Winter Indoor Design: 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Altitude Correction Factor: 0 Model: TM9E040A10MP11 Heating Input(btuh): 40000 AHRI Ref#: 7137317 Heating Output(btuh): 38000 Efficiency (AFUE): 95 Calculated HeatPump 0 Output @ Design (btuh): Cooling Equipment Mfg: CHAMPION BY JOHNSON Altitude Correction Factor: 0 Oudoor Unit Model: TC3B1821 Rated Total Cooling (btuh): 17300 Coil: FC/MC/PC24A+TXV Sensible Cooling (btuh): 12975 Furnace: TM9E040A10MP11 Latent Cooling (btuh): 4325 AHRI Ref#: 8534582 SEER - EER@95: Heat Pump HSPF: Summary MJB Calculations Status Equipment Capacities Sensible Gain (btuh): 9624 Sufficient Sensible Capacity (btuh): 12975 Latent Gain (btuh): 1312 Sufficient Latent Capacity (btuh): 4325 Total Heat.Gain (btuh): 10936 Sufficient Total Capacity (btuh): 17300 Heat Loss (btuh): 21759 Sufficient Heating Capacity (btuh): 38000 Adtek AccuLoad Report Version 17.3.5 Page 2 Your Comp-$ny H'`'re... Maynard construction harris job Your Address Here... -City Here..., State Here..Zip Here... 20 knox rd Phone Here..... -Email Here... Sales Consultant: Job#: harris job Date: 09/01/2020 System 9 Design Conditions Location: Elevation: 0 Daily Range: 0 Design Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 0 Design Grains: 0 Summer: 92 72 Summer Design RH% 0 Winter: -17 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Heating Input(btuh): N/A Model: TM9E040A10MP11 Heating Output(btuh): 38000 AHRI Ref#: 7137317 Calculated HeatPump 0 Efficiency (AFUE): N/A Output ae Design (btuh): Outdoor Equipment Mfg: CHAMPION BY JOHNSON Rated Total Cooling (btuh): 17300 Oudoor Unit Model: TC3B1821 Sensible Cooling (btuh): 12975 Coil: FCIMC/PC24A+TXV Latent Cooling (btuh): 4325 Indoor Unit: TM9E040A10MP11 AHRI Ref#: 8534582 Adtek AccuLoad Report Version 17.3.5 Page 7