ResCheck • REScheck Software Version 4.7.1 r
‘Eit, y od
Compliance Certificate a x .tO
° N N
Co a� w
Project Maynard Construction / Harri -Addition-- a
I RI ll V E cn� ,:
Energy Code: 2018 IECC �, � -_ O
Location: Lake George, New York - I =
Construction Type: Single-family AUG 19 202 ; Li) n
Project Type: Addition I"
Climate Zone: 6 (7377 HDD) TOWN OF O. P4€-NP? `i' i N 020
1N Permit Date: NBUILDG a G�'_. " d
.-1..-1. 0
Permit Number: OM.
ID M
Construction Site: Owner/Agent: Designer/Contractor: U) N
20 Knox Road Harvest Homes :y' 0
Lake Geaorge, NY 12845 1331 Cole Road
Delanson, NY 12053
Compliance:Passes.using UA trade-of
Compliance: 1.8%Better Than Code Maximum UA: 110 Your UA: 108
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.,
Assembly or R-Value R-Value U-Factor UA
Perimeter
New Addition Ceiling: Flat Ceiling or Scissor Truss 584 38.0 0.0 0.030 17
Skylight 1:Wood Frame:Double Pane with Low-E 7 0.410 3 -
Comment: Velux VS C06
New Addition Wall:Wood Frame, 16" o.c. 653 .21.0 6.0 0.041 23
Comment: Cont..1" Rigid insulation R-6
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E , 80 0.260 21
New Addition Floor: All-Wood Joist/Truss:Over Unconditioned Space 48 30.0 0.0 0.033 2
Basement Wall 1: Solid Concrete or Masonry 741 0.0 13.0 0.053 39
Wall height:7.8'
Depth below grade: 7.1'
Insulation depth:7.0'
Window 2: Metal Frame:Single Pane 6 0.500 3
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version 4.7.1 and to comply with the mandatory requirements listed ijt.t 3e REScheck Inspection Checklist. /Zo
Mac(-l.q � IPPPe.� � P . --, 0\>,. e(I-Z
Name-Title Signature /se-` v.'C- A,o ' '` Date
r- Iti( \\ Li! )
\?,\\,k 008303xPP),> )
Project Title: Maynard Construction / Harris Addition Report date: 08/12/20
Data filename:J:\Mitek\Jobs\2020\J4615\A-Structure Attachments\HH Plans\J4615 REScheck just Page 1 of 1
addition 2018 IECC.rck
•
2018 IECC Ener
Efficiency gy
Certificate
Insulation.Rating_ a.. R-Value.
Above-Grade Wall 27.00
Below-Grade Wall 13.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC L
Window 0.26
Door
Skylight 0.41
Heating 8 Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments