Loading...
CC-0133-2020 Office Use Only ADDITION/ALTERATION PERMIT Permit#: CC- ®l'��- 2020 -` ' APPLICATION Town of Queensbury Permit Fee:$ '�� 742 Bay Road,Queensbury,NY 12804 ¢� P:518-761-8256 www.queensbury.net Invoice#: 2`rv� Project Location: 365 Bay Road Tax Map ID#: 296.19-1-30 Subdivision Name: FILE COPY CONTACT INFORMATION: • Applicant: Name(s): Aaroninc Realty LLC Mailing Address, C/S/Z: 18 Berry Patch Drive, Queensbury NY 12804 Cell Phone: 518-932-1437 Land Line: _( ) Email:Aaron12804@gmail.com m IV• Primary Owner(s): �- � Name(s): Aaroninc Realty LLC 1 Mailing Address, C/S/Z: 18 Berry Patch Drive, Queensbury NY 12804 L [1 MAR 2 3 2020 4, I Cell Phone: 518-932-1437 Land Line: _( ) Email: Aaron12804@gmail.com IOWNOFUELi-SE3tiR BUILDING ❑ Check if all work will be performed by homeowner only • Contractor(s): Contact Name(s): Brian Cele-. \C— V-V\ c15 c \ 1.UQ— 1 p • Contractor Trade: General Contractor c\c\ (6i-c)�pp.� �T . t� Mailing Address, C/S/Z: "" Cell Phone:SelligaMenfr1 Land Line: _( ) Email: 19.) c,\&14S1C_0c\Awc_fto \e. Ft\o.\` - co c�1 **List all additional contractors on the back of this form • Architect(s)/Engineer(s): Business Name: Rucinski Hall Architecture Contact Name(s): Ethan Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone:_( ) Land Line: 518-741-0268 Email: ephall@nycap.rr.com Contact Person for Building & Code Compliance: Ethan P. Hall Cell Phone:_( ) Land Line: 518-741-0268 Email: ephall@nycap.rr.com Addition/Alteration Application Revised February 2019 r • -% PROJECT INFORMATION: TYPE: ® Commercial ❑ Residential WORK CLASS: ❑ Single-Family ❑Two-Family ❑Multi-Family(#of units ❑Townhouse DBusiness Office XRetail ❑ Industrial/Warehouse ❑ Garage (#of cars ) ❑ Other(describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 2,524 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total square feet: Total square feet: 2,524 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 25,000 2. If Commercial project, what is the proposed use: Retail Sales—Liquor Store 3. Source of heat: ®Gas❑Oil❑Propane❑Solar ❑Other Fireplaces need a separate Fuel Burning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? -DYES ONO Explain: 5. Are there any easements on the property? DYES ®NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? 0.334 acres b. Is this a corner lot? DYES ONO c. Will the grade be changed as a result of the construction? DYES ONO d. What is the water source? ®PUBLIC ❑PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? Sewer Addition/Alteration Application Revised February 2019 4 _ DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: AfaRVCIllienastr rt2Z11-1 AMA SIGNATURE. , DATE: A1.020 Addition/Alteration Application Revised February 2019 REVIEWED FOR ENERGY CODE compilANcE COMcheck sartw rftl Interior Lighting. Compliance Certificate FILE COPY Project Information Energy Code: 2015 IECC • Project Title: Renovations to 365 Bay Road Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor:.. 365.Bay Road Aaron Liu Ethan P Hall Queensbury; NY 12804 365 Bay Road Rucinski Hall Architecture Queensbury.;:NY 12804 134 Dix Ave 518-932-1437 Glens Falls, NY 12801 _ Aaron12804@gmail.com 518-741-0274 ephall@nycap:rr.com Allowed Interior Lighting Power r._.7 11 Li Area Category Floor Area- Allowed Allowed Watts rIl1 MAR 2 3 2020 i f Ij(ft2) Watts/ft2 (B X C) 1-Retail:Sales Area E j. ; ;1997 1.59 : 3175 2Common Space Types:Office-Enclosed TOWN OF V1(P s,j :? ;;_t 171 1.11 190 3-Warehouse:Medium/Bulky/Pallet Material StoragegR^ BUSiDING' t.� ', ij; =": 396 0.58 230 Total Allowed Watts= 3595. Proposed Interior Lighting Power A B C D E Fixture ID Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture . (C X D) Fixture Fixtures Watt. Retail:Sales Area(1997 sq.ft.) LED 1:LED PAR 17W: 1 45 32 1440 LED 3:LED PAR 15W: 1 3 32 . 96 Common Space Types:Office•-Enclosed(171 sq.ft:) LED 2:LED Linear 17W: 1 2 32 64 Warehouse:Medium/Bulky/Pallet Material Storage(396 sq.ft:) LED 4:LED PAR 17W: 1 9 32 •. 288 Total Proposed Watts= 1888 Interior Lighting PASSES Interior Lighting Compliance Statement : Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COM eck rsion 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Ch ist. Ethan P. Hall-Architect s_05,7. Name-Title :. Sign e Date. 296.19-1-30 CC-0133-2020 Aaronic Realty LLC 365 Bay Rd Project Title: Renovations to 365 Bay Road Commercial Int Alterations 2524 s.f. ' Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Renovations to 365 Bay Road Project Type: Alteration Exterior Lighting Zone 2(Neighborhood business district) Construction Site: Owner/Agent: .. Designer/Contractor: 365 Bay Road Aaron Liu Ethan P. Hall Queensbury, NY 12804 . 365 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave 518-932-1437 Glens Falls, NY 12801 Aaron12804@gmaiil.com 518-741-0274 ephall@nycap.rr.com Allowed Exterior Lighting Power A B. . . C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit . Wattage (B X C) Entry canopy. . 2 ft2 0.25. Yes 0 Total Tradable Watts(a)= 0 Total Allowed Watts= 0 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable.areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID :Description:/Lamp/Wattage Per Lamp/Ballast Lamps/ #of. - Fixture (C X D) Fixture . Fixtures Watt. Entry.canopy(2 ft2):Tradable Wattage LED 1:LED PAR 17W: . 1 4 . 32 128 Total Tradable Proposed Watts= 128 Exterior Lighting PASSES Exterior Lighting Compliance Statement Compliance Statement The proposed exterior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application:The proposed exterior lighting systems have been designed to meet the 2015 IECC requirement in COMc ck V i 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Ch= st. Ethan P. Hall-Architect ,3 A/1(G�=7o20 Name-Title Sign.-.re Date Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 2 of 13 COMcheck Software Version 4.1.1.0 VI Mechanical .Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Renovations to 365 Bay Road Location: Glens Falls, New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 365 Bay Road Aaron Liu Ethan P, Hall Queensbury, NY 12804 365 Bay Road Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave. 518-932-1437 Glens Falls, NY 12801 Aaron12804@gmail.com 518-741-0274 ephall@nycap.rr.com Mechanical Systems List. Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=72 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling:1 each-Field-Assembled DX System,Capacity=53 kBtu/h,Air-Cooled Condenser,Air Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans:.. FAN 1 Supply,Single-Zone VAV,300 CFM,0.5 motor nameplate hp,93.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Versi•//.1.1.0 to A) t " ply with any applicable mandatory requirements listed in the Inspection Checklist. Ethan P. Hall-Architect . /. • . . . . 0A Name-Title Sign.to - Date Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 3 of 13 COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheekRequirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans,specifications, and/or DComplies Requirement will be met. [PR2]1 calculations provide all information ODoes Not with which compliance can be Location on plans/spec:A-1 determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 :Plans,specifications,and/or ❑Complies Requirement will be met. [PRO calculations provide all.information ❑Does Not with which compliance can be Location on plans/spec:A-1 determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations;wattage of bulbs and ballasts,transformers and control devices. C103,2 :Plans,specifications, and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ElDoes Not ;with which compliance can be Location on plans/spec:A-1 (determined for the exterior lighting Not Observable and electrical systems and equipment ❑Not Applicable and document Where exceptions to the standard are claimed.Information provided should include exterior ;lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 4 of 13 Section Footing/Foundation Inspection Complies? Comments/Assumptions &Req.ID C403.2.4. ;Snow/ice melting system sensors for ❑Complies Exception: Requirement does not apply. 5, ;future connection to controls:Freeze ❑Does Not C403.2.4. protection systems have automatic 6 I controls installed. -Not Observable [F09]3 { - : ❑Not Applicable Additional Comments/Assumptions: 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365.Bay Road\365 Bay Road.cck Page 5 of 13 - Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms OComplies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ' Oboes Not C404.5.2 requirements: Refer to section details. [PL6]3 ; ONot Observable ONot Applicable C404.6.3 ;Pumps that circulate Water between a .OComplies Exception: Requirement does not apply. [PL7]3 theater:and storage tank have controls ❑Does Not . ',that limit operation from startup to ., <=5 minutes after end of heating ONot Observable I cycle. ONot Applicable C404.7 Water distribution system that pumps OComplies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ODoes:Not pipe back to the heated-water source through,a cold-water supply pipe is:a ONot Observable )demand recirculation water system. ONot Applicable Pumps within this system'have. i controls that-start the pump upon receiving a'signal'from'the'action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High.lmpact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 6 of 13 Section Mechanical Rough-In Inspection. Complies? Comments/Assumptions & Req.ID C402.2.6 ;Thermally ineffective panel surfaces of❑Complies Exceptions Requirement does not apply. [ME41]3 ;sensible heating panels have ODoes'Not insulation>=R-3.5. ONot Observable ONotApplicable C403.2.13 j Unenclosed spaces that are.heated ❑Complies Exception: Requirement does not apply. [ME71]z use only radiant heat. ❑Does Not :Not Observable ONot Applicable C403.2.3 HVAC equipment efficiency verified: ❑Complies See the Mechanical systems list for values. [ME55]2 ODoes Not. . . I:Not Observable ONot Applicable C403.2.6. ;Demand control ventilation provided ❑Complies Exception:-Requirement does not apply. 1 ••Ifor spaces>500 ft2 and >25- ODoes Not [ME59]1 ;people/1000 ft2 occupant density and ;served by systems with airside ['Not Observable economizer,,auto modulating outside ONot Applicable ;air damper control,or design airflow 1>3,000 cfm.: C403.2.6. ;Enclosed parking:garage ventilation ❑Complies.' Exception: Requirement does not apply. 2 ;has automatic contaminant detection ❑Does.Not : [ME115]3 and capacity.to stage or modulate ,fans to 50%or less of design capacity. [Not Observable ❑Not Applicable C403.2.7 ;Exhaust air energy recovery on ❑Complies Exception: Requirement does not apply: [ME57]1 systems meeting Table,C403.2.7(1) ODoes.Not and C403.2.7(2). ONot Observable ONot Applicable C403.2.8 I Kitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply. [ME116]3 replacement air and conditioned ODoes Not supply air limitations;and satisfy hood: rating requirements and maximum. . ❑Not.Observable ;exhaust rate criteria. ONot Applicable C403.2.9 ;HVAC ducts and plenums insulated. ❑Complies Exception: Requirement does not apply. [ME60]2 Where ducts or plenums are installed ❑Does Not in or under a slab,verification may { [Not Observable need to Occur during Foundation j Inspection. ONot.Applicable C403.2.9 Ibucts and plenums sealed based on ❑Complies. _ Requirement will be met. [ME10]2 Istatic.pressure and location. ODoes Not ONot Observable Location'on plans/spec:A-1 ONot Applicable C403.2.9. ;Ductwork operating>3 in.water ❑Complies Exception: Requirement does not apply. 1.3 'column requires air leakage testing. ODoes Not [ME11]3 ONot Observable ❑Not Applicable C403.4.4. I Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply. 6 l of individual zone boxes have static ODoes Not [ME110]3 ;pressure setpoint reset controls: See the Mechanical Systems list for values. ❑Not Observable ONot Applicable• C408.2.2. Air Outlets and zone terminal devices ['Complies Exception: Requirement does not apply. 1 {have means for air balancing. ❑ Does Not [ME53]3 ['Not Observable ONot Applicable. . 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low'Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 7 of 13 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.5, Refrigerated display cases,walk-in ❑Complies Exception: Requirement does not apply. C403.5.1, I coolers or walk-in freezers served by Oboes Not C403.5.2 /remote compressors and remote [ME123]3 ;condensers not located in a Not Observable condensing unit, have fan-powered.. ❑Not Applicable I condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename:. Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 8 of 13 Section # Rough-In Electrical InsPection Complies? Comments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least ODoes Not 50%. Location on plans/spec:A-1 ONot Observable O Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [EL18]1 required spaces. ODoes Not ONot Observable Location on plans/spec:A-1 O Not Applicable'.. C405.2.1, Independent lighting controls installed ❑Complies_ Requirement will be met. C405.2.2. per approved lighting plans and all . ODoes Not 3 manual controls readily accessible and Location on plans/spec:A-1 [EL23]2 visible to occupants. ONot Observable ONot Applicable C405.2.2. !Automatic controls to shut off all ❑Complies Requirement will be met. 1 !building lighting installed in all ODoes Not [EL22]2 !buildings. ONot Observable Location on plans/spec:A-1 ONot Applicable C405.2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply: [EL16]2 individual Controls that control the ODoes Not lights independent of general area lighting. ONot Observable ONot Applicable C405.2.3, Primary sidelighted areas are DComplies Exception: Requirement does not apply. C405.2:3. equipped with required lighting ODoes Not 1, controls. C405.2.3. ONot Observable 2 ONot Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ODoes Not 1; are equipped with required lighting C405.2.3; controls. ['Not Observable 3 ❑Not_Applicable [EL21]1 C405.2.4 ;Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 (specific uses installed per approved ODoes Not ;lighting plans: Location_on plans/Spec:A-1 ONot Observable ONot Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ODoes Not approved lighting plans and is Location on plans/spec:A-1 automatically controlled and. ❑Not Observable separated from general lighting. 'ONot Applicable C405.2.5 Automatic lighting controls for exterior ❑Complies Exception: Requirement does not apply: [EL25]nall lighting installed.Controls will be ODoes Not daylight controlled;set based on business operation time-of-day,or Not Observable reduce connected lighting >30%. ONot Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 face. ODoes Not ONot Observable Location on plans/spec:A-1 ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 9 of 13 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 10 of 13 • • Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, ;Furnished O&M instructions for DComplies Requirement will be met. C408.2.5. systems and equipment to the Oboes Not 2 ;building owner or designated [FI17]3 (representative. ONot Observable ONot Applicable C303.3, Furnished O&M manuals for HVAC DComplies Requirement will be met. C408.2.5. i systems within 90 days of system ODoes Not 3 ;acceptance. [FI8]3 ['Not Observable ONot Applicable C403.2.2 I HVAC systems and equipment DComplies Requirement will be met. [FI27]3 (capacity does not exceed calculated ODoes Not loads: Location on plans/spec:A-1 ONot Observable ONot Applicable . . C403.2.4. ;Heating and cooling to each zone is ❑Complies Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [F147]3 ;Minimum one humidity control device Location on plans/spec:A-1 per installed :Not Observable humidification/dehumidification ONot Applicable system.: C403.2.4. ;Thermostatic controls have a 5 °F ❑Complies Requirement Will be met. 1.2 Ideadband. ODoes Not (FI38]3 Location on plans/spec:A-1 ONot Observable DNot Applicable C403.2.4. ;Temperature controls have setpoint DComplies Exception: Requirement does not apply. L3 20]3 overlap restrictions. ❑Does Not DNot Observable DNot Applicable C403.2.4. ;Each zone equipped with setback DComplies Exception; Requirement does not apply: 2 I controls using automatic time clock or ODoes Not [FI39]3 programmable control system. ['Not Observable DNot Applicable C403.2.4. ;Automatic Controls:Setback to 55°F ❑Complies Exception: Requirement does not apply. 2.1, ;(heat)and 85°F(cool); 7-day clock, 2- ❑Does Not C403.2.4. ;hour occupant override, 10-hour 2.2 backup ONot Observable [F140]3 ii ONot Applicable C403.2.4. ;Systems include optimum start ;DComplies Requirement will be met: 2.3 {controls. ❑Does Not [FI41]3 Location on plans/spec:A-1 ;❑Not Observable . {ONot Applicable C405.4:1 Interior installed lamp and fixture ❑Complies See the/nteriorLighting fixture schedule for values. [F118]' lighting power is consistent with what ❑Does Not is shown on the approved lighting plans;demonstrating proposed watts ['Not Observable are less than or equal to allowed DNot Applicable watts. C405.5.1 ;Exterior lighting power is consistent DComplies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown oh the approved ❑Does Not lighting plans,demonstrating proposed watts are less than or equal ONot Observable to allowed watts. ONot Applicable C408.2.1 ;Commissioning plan developed by DComplies Requirement will be met. [FI28]1 registered design professional or ODoes Not approved agency. Location On plans/spec:A-1 ❑Not Observable Not Applicable 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2). 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365.Bay Road\365 Bay Road.cck Page 11 of 13 Section Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. HVAC equipment has been tested to DComplies Exception: Unitary or packaged HVAC eqiupment without 1 ensure proper operation. ❑Does Not supply air economizers: [FI31]1 ❑Not Observable DNotApplicable C408.2.3. HVAC control systems have been DComplies Requirement will be met. 2 tested to ensure proper.operation; ❑Does Not [FI10)1 calibration and adjustment of controls. Location on plans/spec:A-1 ❑Not Observable ONot Applicable C408.2.4 Preliminary commissioning report DComplies Requirement will be met. [FI29]1 completed and certified by registered ❑Does Not design professional or approved Location on plans/spec:A-1 ;agency. ❑Not Observaole :Not Applicable C408.2.5. Furnished HVAC as-built drawings DComplies Requirement will be met. 1 submitted within 90 days of system Oboes Not [F17)3 acceptance. [Not Observable ❑Not Applicable. C408.2.5. I Furnished as-built drawings for. DComplies Requirement will be met. 1 I electric power systems within 90 days ❑Does Not [FI16]3 i of system acceptance. ❑Not Observable 1 ❑Not Applicable C408.2.5. An air and/or hydronic system DComplies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [F143]i systems. Location on plans/spec:A-1 ONot Observable ❑Not Applicable C408.2.5. :Final commissioning report due to DComplies Requirement will be met. 4 building owner within 90 days of. ❑Does Not [F130]1 ;receipt of certificate.of'Occupancy. Not Observable Location on plans/spec:AL]. :11DNot_Applicable C408.3 Lighting systems have been tested to DComplies Requirement will be met [F133]1 ienSure proper calibration; adjustment; ❑Does Not programming,and operation. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365.Bay Road\365 Bay Road.cck Page 12 of 13 Project Title: Renovations to 365 Bay Road Report date: 03/23/20 Data filename: Y:\Aaron Liu\365 Bay Road\365 Bay Road.cck Page 13 of 13 � � FIRE MARSHAL'S OFFICE _w 1___ . Town of Queensbury ET 742 Bay Road, Queensbury, NY 12804 y "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Aaronic Realty LLC 365 Bay Road CC-0133-2020 FILE COPY 9/23/2020 The following comments based on review of the submitted plans: 1) Fire Extinguisher locations to be discussed. 2) Locks & latches shall comply with 2015 IFC. 3) Exit & emergency lights locations appear adequate. Fire Marshal to witness a function test prior to CO. Verify exterior emergency lights per plan. 4) Carbon Monoxide detection required. 5) Knox Box location ok per plan, provide keys for both businesses. Deputy ire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 firemarshal@queensbury.net • www.queensbury.net t!. 267 MAX . _ . !1. ; HEAT RECOVERY VENTILATOR. FILE COPY . a LIFEBREFITH- ENGINEERING DATA II, ✓. THERMALLY CONDUCTIVE, PATENTED DEFROST ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)OD.Balancing ports Each airstream has an independent motorized EC impeller with multiple fan speed are located on door. operations. ELECTRONICS FILTERS The DXPL02 control included with the unit can he wall mounted in a central location of Washable air filters in exhaust and supply air streams. the home.3 wire 20 gauge(min.)100 ft length(max.). MOUNTING Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and WARRANTY . hanging straps supplied with the unit. units carry a lifetime warranty on the HRV core and a 5 year replacement parts Warranty. OPTIONAL ACCESSORIES: Weather Hoods Wireless 20/40/60 TechGrille Terminator 99-186 Min Timer 99-EAG4 Fitting _- 99-DET02 99-EAGS - 99-TM4 99-EAG6 99 TMS <�• �' , 99-EAG8 99-TM6 t, LIFEBREATH CONTROL OPTIONS TIMER OPTIONS FEATURES 99-DXPLO2 99-BL02 99-BC03 99=B004 99 DETOl Lifebreath 20/40/60 Minute Timer Initiates high speed Ventilation for 20,40 or 60 5 speed fan operation on each mode ✓ minutes.3 wire connection. 99-DET02 2 speed fan operation(Low/High) ✓ ✓ Wireless Lifebreath 20/40/60 Minute Timer • Continuous low speed fan operation ✓ Initiates high speed Ventilation for 20,40 or 60 . minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ✓ ✓ ✓ ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen ✓ 99-RX02-Wireless Lifebreath Repeater LED status indicator lights ✓ ✓ ✓ Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation ✓ ✓ main control and 99-DET02.Install at halfway ✓ ✓ point between timer and main wall control if timer Continuous Recirculation is out of range. 20 ON/40 OFF ✓ .___ - -, 10 ON/50 OFF ✓ -- 20 0N/40 Recirculation ✓ ✓ ✓ 0r Ic I* ;oi--• ' 20/40/60 min.High speed override button ✓ 99-DXPL02.__.___________I 99-DETD2 Compatible with 99-DET02 Wireless Timer ✓ V ✓ ✓ -I 3 wire connection ✓ I ✓ ✓ L IFE®REFTH ,l Indoor Air Systems 69-267MAX(11-29-17) www.lifebreath.com , , tr 267MAx 'k 1 • HEAT RECOVERY VENTILATOR PERFORMANCE (HVI CERTIFIED) , LIFEBREHTH` 0.1(2S) 0.2(50) 0.3(7S) 0.4(100) 0.5(12S) 0.6(150) 0.7(17S) 0.8(200) ELECTRICAL SPECIFICATIONS IN.W.G.(PA) CFM(Vs) CFM(Us) CFM(Vs) CFM(Us) CFM(Us) CFM(Vs) CFM(Us) CFM(Us) VAC @ 60Hz 120 Net Supply Airflow 279(132) 273(129) 261(126) 261(123) 255(120) 248(117) 241(114) 234(111) Watts 1 Low Speed 22 Gross Supply Airflow 283(133) 277(131) 271(128) 264(125) 258(122) 251(119) 245(115) 238(112) Watts/High Speed 44 Gross Exhaust Airflow 314(148) 308(145) 301(142) 294(139) 287(135) 280(132) 272(129) 265(125) Amp Rating 4.5 Sensible Effectiveness(ASE) 32°F(0°C) 80% 300 WEIGHT: @ 64 CFM(30 Us) 57 LBS(25.8 KG) Sensible Efficiency(ASE) 250 SHIPPING WEIGHT: @ 116 CFM(55 Us) 32°F(0°C) 72% 67 LBS(30 KG) gg: (SRO) 200y( 32°F(0°C) 75% Eo noNOTEy(SRE) 32°F(0°C) 68% Front clearance of 25 in.(635 mm)is s) a recommended for servicing unit.All ducts Sensible Efficiency(SRE) _13°F(-25°C) 70% loo use 6 in.(152 mm)oval collars,balancing @ 72 CFM(34 Us) dampers are located on all collars. so FE e ISO 0c r c us VI 9001 o �m� , i .�, CERTIFIED mom inon 0.2 0.4 0.6 0.8 1.0 Static Pressure(in w.g.) DIMENSIONS FRONT VIEW 6 in.(150 mm) ° Filter • Collars-----I I I� i-1 I—I Recirculating I I _ l r I I j TOP VIEW Defrost Damper I I I _ r\ - i E A — * Stale air to outside Removable Heat ,- '1> — I . I / \ 3 Es / d I•� I C m Fresh air from outside Recovery Core s'i� �-: t � �� .#r.,` r F _ = � � � � I � Stale air from inside /� / ` m Fresh air to inside Motorized. _ Impeller Condensate! 33 5/8 in.(854 mm) Drain 4 ►I Date: WARRANTY Contractor. Units carry a lifetime warranty Tag: on the.HRV core and a S year replacement parts warranty. Project' QtY Supplier. Engineer: Quote#: All units conform to C5A and UL standards Of Control: Submitted By: L/FEBRERTHm a Indoor Air Systems Timer: Timer Oty: 69-267MAX(11-29-17) www.lifebreath.com . Your Company Here... 365 bay road side unit Your Address Here... -City Here..., State Here..Zip Here... Phone Here -Email Here... Sales Consultant: FILE COPY Job#: 365 bay road side unit Date: 09/2212020 Equipment Selection Design Conditions Design Location: Glens Falls AP, New York Relative Humidity: 50%. Elevation: 335 ft Summer Outdoor Design: 92 Latitude: 43°N Winter Outdoor Design: -17 Daily Range: Medium Summer Indoor Design: 72 Design Grains 26 Winter Indoor Design: 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Altitude Correction Factor: 0 Model: TM9E080B12MP11 Heating Input(btuh): 80 AHRI Ref#: 7141702 Heating Output(btuh): 77000 Efficiency (AFUE): 95 Calculated HeatPump 0 Output @ Design (btuh): Cooling Equipment Mfg: CHAMPION BY JOHNSON Altitude Correction Factor: 0 Oudoor Unit Model: TC3B3021 Rated Total Cooling (btuh): 30000 Coil: CF/CM/CU36C+TXV Sensible Cooling (btuh): 22500 Furnace: TM9E080C16MP11 Latent Cooling(btuh): 7500 AHRI Ref#: 8535866 SEER - EER@95: Heat Pump HSPF: Summary MJ8 Calculations. Status Equipment Capacities Sensible Gain (btuh): 15120 Sufficient Sensible Capacity (btuh): 22500 Latent Gain (btuh): 2248 Sufficient Latent Capacity (btuh): 7500 Total Heat Gain (btuh): 17368 Sufficient Total Capacity (btuh): 30000 Heat Loss(btuh): 36509 Sufficient Heating Capacity(btuh): 77000 Adtek AccuLoad Report Version 17.3.5 Page 3 • Your Company Here... 365 bay road side unit Your Address Here... -City Here..., State Here..Zip Here... Phone Here -Email Here... Sales Consultant: Job#: 365 bay road side unit Date: 09/22/2020 System I Design Conditions Location: Elevation: 0 Daily Range: 0 Design Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 0 Design Grains: 0 Summer: 92 72 Summer Design RH% 0 Winter: -17 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Heating Input(btuh): N/A Model: TM9E080B12MP11 Heating Output(btuh): 77000 AHRI Ref#: 7141702 Calculated HeatPump 0 Efficiency(AFUE): N/A Output @ Design (btuh): Outdoor Equipment Mfg: CHAMPION BY JOHNSON Rated Total Cooling (btuh): 30000 Oudoor Unit Model: TC3B3021 Sensible Cooling (btuh): 22500 Coil: CF/CM/CU36C+TXV Latent Cooling (btuh): 7500 Indoor Unit: TM9E080C16MP11 AHRI Ref#: 8535866 Adtek AccuLoad Report Version 17.3.5 Page 8 Your Company Here... 365 bay roadside unit Your Address Here... -City Here...,State Here..Zip Here... Phone Here -Email Here... Sales Consultant: Job#: 365 bay road side unit Date: 09/22/2020 Expanded Manual S (ACCA Guidelines) MJ8 Design Calculations Sensible Gain (btuh): 15120 Design TD for Airflow: 17 Latent Gain (btuh): 2248 Design CFM: 809 Total Heat Gain (btuh): 17368 SHR: 0.87 Heat Loss(btuh): 36509 Manufacturers Performance Data(A) Entering Coil Temperature=75(F db) Lower Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 63 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Manufacturers Performance Data(B) Entering Coil Temperature= 75(F db) Higher Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 63 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Equipment Performance Data Entering Coil Temperature=75(F db) Design Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Intopolated Equipment Capacity 0 0 0 Excess Latent Capacity Calculation 0 0 0 0 0 Capacity @ Design CFM/RA (F wb) ' 0 0 0 Equipment Capacity as a% of Design Equipment Performance Data Thermal Entering Coil Temperature=75 (F db) Capacity Capacity Balance Supplemental @ 47 F db @ 17 F db Point Heat Required Heat Pump Data, N/A N/A 0 0 Desired Input Output AFUE Temperature Calculated Capacity Capacity Rise Airflow Furnace Data N/A N/A N/A N/A 0 Adtek AccuLoad Report Version 17.3.5 Page 9 Your Company Here... Your Address Here...-City Here...,State Here..Zip Here... 365 bay road Phone Here -Email Here... Sales Consultant: Job#: 365 bay road Date: 09/22/2020 Equipment Selection Design Conditions Design Location: Glens Falls AP, New York Relative Humidity; 50% Elevation: 335 ft Summer Outdoor Design: 92 Latitude: 43° N Winter Outdoor Design: -17 Daily.Range: Medium Summer Indoor Design: 72 Design Grains 26 Winter Indoor Design: 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Altitude Correction Factor: 0 Model: TM9E060B12MP11 Heating Input(btuh): 60 AHRI Ref#: 7117949 Heating Output(btuh): 57000 Efficiency (AFUE): 95 Calculated HeatPump 0 Output @ Design (btuh): Cooling Equipment Mfg: YORK BY JOHNSON CONTROLS Altitude Correction Factor: 0 Oudoor Unit Model: YCD30B21 Rated Total Cooling (btuh): 29800 Coil: CF/CM/CU36B+TXV Sensible Cooling (btuh): 35000 Furnace: TM9E060B12MP11 Latent Cooling (btuh); 7450 AHRI Ref#: 8487118 SEER - EER@95: Heat Pump HSPF: Summary MJ8 Calculations Status Equipment Capacities Sensible Gain(btuh): 23193 Sufficient Sensible Capacity(btuh): 35000 Latent Gain (btuh): 2060 • Sufficient Latent Capacity(btuh): 7450 Total Heat Gain (btuh): 25253 Sufficient Total Capacity (btuh): 29800 Heat Loss (btuh): 42202 Sufficient Heating Capacity(btuh): 57000. Adtek AccuLoad Report Version 17.3.5 Page 3 Your Company Here... 365 bay road Your Address.Here...-City Here..., State Here..Zip Here... Phone Here -Email Here... Sales Consultant: Job#: 365 bay road Date: 09/22/2020 System Design Conditions Location: Elevation: 0 Daily Range:. 0 Design Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 0 Design Grains: 0 Summer: 92 72 Summer Design RH% 0 Winter: -17 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Heating Input(btuh): N/A Model: TM9E060B12MP11 Heating Output(btuh): 57000 AHRI Ref#: 7117949 Calculated HeatPump 0 Efficiency(AFIJE): N/A Output @ Design (btuh): Outdoor Equipment Mfg: YORK BY JOHNSON CONTROLS Rated Total Cooling(btuh): 29800. Oudoor Unit Model: YCD30B21 Sensible Cooling (btuh): 35000 Coil: CF/CM/CU36B+TXV Latent Cooling (btuh): 7450 Indoor Unit: TM9E060B12MP11 AHRI Ref#: 8487118 Adtek AccuLoad Report Version 17.3.5 Page 8 Your Company Here... 365 bay road Your Address Here...-City Here..., State Here..Zip Here... • Phone Here -Email Here... Sales Consultant: Job#: 365 bay road Date: 09/22/2020 Expanded Manual.S (ACCA Guidelines) MJ8 Design Calculations Sensible Gain (btuh): 23193 Design TD for Airflow: 17 Latent Gain(btuh): 2060 Design CFM: 1240 Total Heat Gain (btuh): 25253 SHR: 0.92 Heat Loss (btuh): 42202 Manufacturers Performance Data(Al Entering Coil Temperature= 75(F db) Lower Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 63 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Manufacturers Performance Data(B) Higher Return Air Total Sensible Latent Entering Coil Temperature=75(F db) CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 0 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Equipment Performance Data Entering Coil Temperature=75 (F db) Design Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Intopolated Equipment Capacity 0 0 0 Excess Latent Capacity Calculation 0 0 0 0 0 Capacity @ Design CFM/RA (F wb)' 0 0 0 Equipment Capacity as a% of Design Equipment Performance Data Entering Coil Temperature= 75 (F db) Capacity Capacity Thermal Supplemental @ 47 F db @ 17 F db Balance Heat Required Point Heat Pump Data NIA N/A 0 0. Input Output Desired Calculated Capacity Capacity AFUE TemperatureAirflow Rise Furnace Data N/A N/A N/A N/A 0 Adtek AccuLoad Report Version 17.3.5 Page 9 Northeastern-Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: Q Air Balance ReportFE D � -� TOWN OF aUEENSBU�Y BUILDING;&COOF Project: 365 Bay Road Bay Road Liquors Location: Queensbury; New York Architect: Rucinski Hall Architecture Glens Fdalls, New York Engineer: Piping: Sheet Metal: Monahan & Every Plumbing and Heating Queensbury, New York Date: 1/28/212 Prepared by: R. Kelley . RKelleyn-NortheasternAirQuality.com CERTIFICATION PROJECT: #REF! ADDRESS: Queensbury, New York THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES.ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED& BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEM"AND THE PROJECT SPECIFICATIONS. TESTING AND BALANCING FIRM: Northeastern Air Quality, Inc. #3159 CERTIFIED BY: Robert V. Kelley DATE: 1/28/212 SIGNATURE: Air Q4a — - ROBERT V.KELLEY. -- CERTIFICATION 3159- p� Exp.3131/22 5 hlydr.00���e Page 2 Northeastern Air Quality,Inc. ABBREVIATIONS P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: #REF! THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: ABBREVIATION MEANING ABBREVIATION MEANING A AMPS orAMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC(EFFECTIVE FREE)AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN.REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SPS STATIC PRESSURE SENSOR DISCH DISCHARGE SR SUPPLY REGISTER DPR DAMPER TC TEMPERATURE CONTROL OP PRESSURE DIFFERENTIAL TCC TEMPERATURE CONTROL CONTRACTOR EC END CAP TCD TEMPERATURE CONTROL DAMPER ER EXHAUST REGISTER TP THERMALLY PROTECTED FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TRAV DUCT TRAVERSE FLA FULL LOAD AMPS V VOLTS or VOLTAGE FTR FINNED TUBE RADIATION VAR VARIABLE GPM GALLONS PER MINUTE VBD V-BELT DRIVE HP HORSEPOWER VD VOLUME DAMPER LD LINEAR DIFFUSER VEL VELOCITY LF LINEAR FEET(NOMINAL) W WATTS or WATTAGE NA NOT ACCESSIBLE WG WALL GRILLE ND NO DAMPER WMS WIRE MESH SCREEN NDRG NON-DUCTED RETURN GRILLE WR WALL REGISTER NG NO GAUGE ZD ZONE DAMPER NI NOT INSTALLED NIC NOT IN CONTRACT Page 3 Northeastern Air Quality,Inc. AIR MOVEMENT EQUIPMENT TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: #REF! TESTED BY: R.Kelley DATE: 1/2812021 SYSTEM: AHU-1 AHU-2 LOCATION: Meh.Closet Meh.Closet SERVICE: North/East Side SothMest MANUFACTURER: York York MODEL: TWE06013112MP12A TWE08013121VIP12A SERIAL NUMBER: W21­10094978 W2H00132211 DATE TESTED: 1/28/2021 1/28/2021 MANUFACTURER Gentech Gentech MOTOR STYLE FRAME - DD - DD NAME- HP RPM 1/2 1050 1/2 1050 PLATE VOLTS PHASE HERTZ 115 1 60 115 1 60 DATA FLAMPS S.F. 6.4 - 6.4 P.F. NOM EFFY - - - - CALCULATED(P.F.x NOM EFFY) 0.57 0.57 STARTER HEATER ELEMENTS - - MOTOR SHEAVE Direct Drive Direct Drive FAN SHEAVE Direct Drive Direct Drive BELTS Direct Drive Direct Drive SHEAVE cL DISTANCE Direct Drive Direct Drive TEST DATA DESIGN ACTUAL DESIGN ACTUAL FAN RPM TOTAL CFM-FAN NS 876 NS 1153 TOTAL CFM-OUTLETS NS 862 NS 1121 RETURN AIR CFM NS 841 NS 851 OUTSIDE AIR CFM NS - NS 222 EXT. DISCHARGE NL 0.17 NL 0.22 STATIC INLET NL 0.26 NL 0.13 PRESSURE TOTAL - 0.43 - 0.35 VOLTS T1-T2 115 122 115 122 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 6.4 2.7 6.4 3.2 12 (3 Ph only) T3(3 Ph only) BHP(calc.) F.L.A. I ACTUAL 0.25 0.30 REMARKS: 'NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 4 Northeastern Air Quality,Inc, ENERGY RECOVERY VENTILATOR TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: 365 Bay Road TESTED BY: R.Kelley DATE: 1128/2021 SYSTEM: ERV1 LOCATION: Storage Room SERVICE: AHU-2 MANUFACTURER: Llfebreath MODEL: 267MaX SERIAL NUMBER: 10202008904 DATE TESTED: 1/28/2021 FAN DATA SUPPLY RETURN MANUFACTURER MOTOR STYLE FRAME - DD - DD NAME- HP RPM PLATE VOLTS I PHASE HERTZ 115 1 60 115 1 60 DATA FLAMPS S.F. 4.5 NS 4.5 NS P.F. NOM EFFY NS NS NS NS calculated(P.F.x NOM EFFY)* 0.72 0.72 STARTER HEATER ELEMENTS - MOTOR SHEAVE Direct Drive Direct Drive FAN SHEAVE Direct Drive Direct Drive BELTS Direct Drive Direct Drive SHEAVE cL DISTANCE Direct Drive Direct Drive TOTAL CFM-FANS TOTALCFM-OUTLETS 180 184 180 178 RETURN AIR CFM OUTSIDE AIR CFM EXT. DISCHARGE NL NL STATIC INLET NL NL PRESSURE TOTAL FAN RPM VOLTS T1-T2 115 122 115 122 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 5 5 T2 (3 Ph only) T3(3 Ph only) BHP(calc.) F.L.A. I ACTUAL 0.06 0.06 REMARKS: *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 5 Northeastem Air Quality,Inc. ENERGY RECOVERY VENTILATOR TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: 365 Bay Road, TESTED BY: DATE: 1/28/2021 SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA SUPPLY RETURN MANUFACTURER MOTOR STYLE FRAME, - NAME- HP RPM PLATE VOLTS I PHASE HERTZ DATA FLAMPS S.F. P.F. NOM EFFY calculated(P.F.x NOM EFFY)' , STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE -11:51 UAIA DESIGN AG I UAL DESIGN- AU I UAL TOTAL CFM-FANS TOTALCFM-OUTLETS RETURN AIR CFM OUTSIDE AIR CFM EXT. DISCHARGE NL NL STATIC INLET NL NL pyr PRESSURE TOTAL FAN RPM VOLTS T1-T2 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 T2 (3 Ph only) T3(3 Ph only) BHP(calc.) F.L.A. ACTUAL REMARKS: 'NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp1(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 6 Northeastem Air Quality,.inc. ENERGY RECOVERY VENTILATOR TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 - PROJECT: 365 Bay Road TESTED BY: DATE: 1/28/2021 SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA SUPPLY RETURN MANUFACTURER MOTOR STYLE FRAME NAME- HP. RPM PLATE VOLTS PHASE ;HERTZ DATA FLAMPS S.F. P.F. NOM EFFY calculated(P.F,x NOM EFFY) STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TOTAL CFM-FANS TOTAL CFM-OUTLETS RETURN AIR CFM OUTSIDE AIR CFM EXT. DISCHARGE NL NL STATIC INLET' NL NL PRESSURE TOTAL FAN RPM VOLTS T1-T2 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 T2 (3 Ph only) T3(3 Ph only) BHP(calc.) F.L.A. ACTUAL REMARKS: *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp1(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 7 Northeastern Air Quality,Inc. ENERGY RECOVERY VENTILATOR TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: 365 Bay Road TESTED BY: DATE: 1/28/2021 SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA SUPPLY RETURN MANUFACTURER MOTOR STYLE FRAME NAME- HP RPM PLATE VOLTS I PHASE HERTZ DATA FLAMPS I S.F. P.F. I NOM EFFY calculated(P.F.x NOM EFFY)* STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TOTAL CFM-FANS TOTAL CFM-OUTLETS RETURN AIR CFM OUTSIDE AIR CFM EXT. DISCHARGE NL NL STATIC INLET NL NL PRESSURE TOTAL FAN RPM VOLTS T1-T2 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 T2 (3 Ph only) T3(3 Ph only) BHP(calc.) F.L.A. ACTUAL REMARKS: *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 8 Northeastern Air Quality,Inc. ENERGY RECOVERY VENTILATOR TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: 365 Bay Road TESTED BY: DATE: 1/28/2021 SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA SUPPLY RETURN MANUFACTURER MOTOR STYLE FRAME NAME- HP I RPM PLATE VOLTS I PHASE HERTZ DATA FLAMPS S.F. P.F. NOM EFFY calculated(P.F.x NOM EFFY)* STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TOTAL CFM-FANS TOTAL CFM-OUTLETS RETURN AIR CFM OUTSIDE AIR CFM EXT. DISCHARGE NL NL STATIC INLET NL NL PRESSURE TOTAL FAN RPM VOLTS T1-T2 T2-T3(3 Ph only) T1-T3(3 Ph only) AMPS T1 T2 (3 Ph only) T3(3 Ph only) BHP(talc.) F.L.A. I ACTUAL REMARKS: *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph Page 9 Northeastern Air Quality,Inc. GRILLE,REGISTER&DIFFUSER REPORT P.O.Box3271,Albany,NY 12203-0271 PROJECT: 365 Bay Road (518)857a641 TESTED BY: R.Kelley DATE: 1/281212 REMARKS: DESIGN INITIAL INTERMEDIATE FINAL %OF. NO. LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS AHU•'1 1 Retail 14"x 6" Hood 48 Hood 48 1/28/21 2 Retail 14"x 6" Hood 75 Hood 75 1/28/21 3 Retail 14"x 6" Hood- 96 Hood 96 1/28/21 4 Retail 14"x 6" Hood 101 Hood 101 1/28/21 5 Retail 14"x 6" Hood 48 Hood 48 1/28/21 6 Retail 14"x 6" Hood 101 Hood 101 1/28/21 7 Retail 14"x 6" Hood 112 Hood 112 1128/21 8 Retail 14"x 6" Hood 88 Hood 88 1/28/21 9 Retail' 14"x 6" Hood 128 Hood 128 1/28/21 10 Retail 14"x 6" Hood 65 Hood 65 1/28/21 Total 862 862 1128121 Retum 11 Floor 30"x 8" Hood 419 Hood 419 1/28121 12 Wall 30"x 8" Hood 422 Hood 422 1/28121 Total 841 841 1128121 AHU•2 13 Retail 12"x 8" Hood 134 Hood 134 1128/21 14 Retail 12"x 8" Hood -133 Hood 133 1/28/21 15 Retail 12"x 8" Hood 118 Hood 118 1/28121 % Rear Entrance 12"x 8" Hood '122 Hood 122 1/28121 17 Retail 12"x 8" Hood 115 Hood 115 1/28121 18 Office 12"x 8" Hood 154- Hood. 154 1/28121 19 Storage' 12"x 8" Hood 135 Hood 135 1/28/21 20 Bathroom 12"x 8" Hood 87 Hood 87 1/28/21 21 Storage 12"x 8" Hood 123 Hood 123 1/28/21 Total 1,121 1,121 1128121 Page 10 Northeastern Air Quality,Inc. GRILLE,REGISTER&DIFFUSER REPORT P.O.Box 3271,Albany,NV 11203-0271 PROJECT: 365 Bay Road (518)857-3841 TESTED BY: R.Kelley DATE: 11281212 REMARKS: DESIGN INITIAL INTERMEDIATE FINAL %OF NO. LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL I CFM DES DATE REMARKS Return 22 Retail Sales 26"x 8" Hood 368 Hood 368 1/28/21 23 Retail Sales 26"x 8" Hood 265 Hood 265 1/28/21 24 Retail Sales 26"x 8" Hood 218 Hood 218 1/28/21 Total 851 851 1128121 ERV 25 Supply 6"R 0.2 NS 921 184 921 181 1/28/21 26 Exhaust 6"R 0.2 NS 942 1781. 942 185 1/28/21 Page 11 Northeastern Air Quality,Inc. Duct Traverse Totals P.O.Box 3271,Albany,NY 12203-0271 PROJECT: #REF! (518)857-3641 DATE: 112812021 System Area DESIGN REQUIRMENT INITIAL FINAL %OF NO. Zone or Branch Duct Size Sq.Ft. VEL CFM VEL CFM SP VEL CFM SP DES DATE T-1 AHU-1 - Supply 8"x 20" 1.11 NS 788 876 788 876 0.17 1128121 T-2 AHU-2 Supply 8"x 20" 1.11 NS 1,038 1,153' 1,038 1,153 0.22 1128121 ERV Low Speed High Speed T-3 Supply 6"Rnd 0.20 1,121 220 936 184 1,106 217 0.10 99% 1/28/21 T-41 Return 6"Rnd 0.20 1 1,121 220 908 178 1,131 222 0.11 101% 1/28/21