2005-576 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CEIKI"IFICATE (D.-Ar' OCCUPANCY Permit Number. P20050576 Date Issued: Tuesday, April 29, 2008 This is to certify that work requested to be done as shown by Permit Number P20050576 has been completed. Location: 6 CLEARVIEW Ln Tax Map Number. 523400-290-014-0001-010-000-0000 Owner. ROBERT & JEANNETTE JENSEN III Applicants ROBERT & JEANNETTE JENSEN III This structure maybe occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the ° property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050576 Application Number: A20050576 Tax Map No: 523400-290-014-0001-010-000-0000 Permission is hereby granted to: ROBERT& JF.ANNF,TTF,JFNSRN III For property located at: 6 CLEARVIEW Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ROBERT & JEANNETTE JENSEN I Residential Addition $6,000.00 6 CLEARVIEW Ln QUEENSBURY, NY 12804 Total Value $6,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-576 192 SQ FT RESIDENTIAL ADDITION(DINING ROOM) $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, August 19, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at of 0uAnsb ry; riday, August 19, 2005 f. SIGNED BY 7 for the Town of Queensbury. Director of Buil ing&Code Enforcement WINDOW SCHEDULE Job Site/A ress: P�v� { (. "� Date: Owner: j��4 T j P= 2 Application No. - S Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cle Opening Opening or Instructions Letter on Name Numbe g Height ibie Vent ar Width In Height Plan Call Width Light Opening Inches In Inches Size D 0106 ,61 f, 7 2�' 7< (2) 30 (a) 2.1 io Sy ° 30 1�5 13 .azS C3� 30 f � 2C Example Entry A Andersen Narroline 3062 3' 2 6'6 % 15.30 8.36 6.01 34 2415/35" Tempered Double 1/3" 11/16 Glazing Hun CADocuments and Settings%ue\Local Settings\Temp\Window Schedule.doc Job Site Address: �r ��V W Date:.. i ���(4- Owner: �P�1e � Application No. File No. S Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req. Light Actual Req.Vent .Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet C ( 0-vu. jq . �o 50 7e2d 25 21 , 77S 1((,,, 37 sf,T-�. E rest L:\,Suel4emingway\Building.Petm9t.FORMS\NatLight Ventil.Calculation.Sheet.doc Check Residential Plan Review: One & Two Family Dwellings Y/N/N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft_ 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Re aired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors �A Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2d Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed w F Permit No. 3uilding &Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director code5@aueensbury.net 'hone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application (form. /� Applicant/Builder 4aL yl� Owner: g013�4 Ji�F41,54 iv' Address: it/ Address: GGx,Ar� �iF�/ L/f.✓ Home Phone: Home Phone: `I3 " 2'ez S- Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: Address: 3O�' �✓ Co�2i Al, J Z.p' hone GSY fal" Location of proposed construction: Lot No._ j Legal #dLkess: e�1 �Ci4ie I��Frr/ Li9�/ S 6, Tax Map Number: S si Z Subdivision Name: Estimated Cost of Construction: $ aao', o o Proposed construction is for: -/Residential Use _Commercial Use ? IQ Name of Business: a If proposed construction is an addition, what will use of new addition be? ►✓//V61-V6, , New Addition Alteration Proposed Construction 10 Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ff. sq.ff. Sq. Ft. Square feet Height Ft.&in. Single-Family Dwelling S" Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil Gas, Wood, Forced Hot Air Baseboard, Cher: If a fireplace and/or woodstove are being installed, please refer to a separate application. Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that i/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. Date: �r2( Applicant/Builder Signature: The application of dated is hereby approved and permission granted for t c nstruction, reconstruction or al er o b r g/and o ccessory structure as set forth above. Date: -t Authorized Signature: ` L:\Sue Hemingway\Building.P rmit. ORMS\Principal Structure Permit Application.doc V:12/14/04 Queensbury Building & Code Enforcement - Residential I I pection Office No. (518)761-8256 Arrive: a a l a r E Date Inspection request received: Inspector's Initia . NAME: PE IT 6— LOCATION: D E: Z- — TYPE OF STRUCTURE: t Comments" Yes No WA 4" Building Number Address visible from road Chimney t/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete I Exterior Finish Com Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at staW#vll at 34 arches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Intedor/Exterior Railings 34 inures to 38 inches Deck Bras /Handicapped Ramp Com cant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e !regulator 18 inches above grade Interior Privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterfight Safety /Window in staaweos safe Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches in aooessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.fL-150 sq.ft.vents Bathroom Fans,d no window Plumbing fwtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emer below grade Gas Furnace shut-off within 30 feet or within one of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater o Low water shut-off boiler Relief Va s installed/Heat TraW Water Temp 110 Enclosed Stairs Sheetroc k Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Seated or Glass Enclosure Final Electrical , Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas NW Bonding As Built Septic System/Sewer Dept. insp29§2n Sticker Site Plan /Variance pNgred Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent 013uilding&Codes Forms1Buftng&Codes\lnspecdon FormslResklential Final inspection Form revised 100405.doc,Revised January 7,2008 Queensbury Building & Code Enforcement - Residential Fi Inspection n O fice No.(518)761-8256 Arrive: `� Date Inspection request received: Inspector's Initials: NAME: L4 P T M LOCATION: TYPE OF STRUCTURE: FR, Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete ` Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access I s . ft.-150 s .ft.vents _74— Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_I00405.doc COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.,... "k, NO 3275Cut-in Card No.................................... Owner...........i, Location........................................................................................................................6. Installation Consisting of... .................... ...................Ap.v .... .......X.J.�.Afd ........... ................................................................................................................................................................................. InstalledBy.............5AM.6.......................................................Lic.No................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon th, introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of m#MYnspections at any time, and if it I k i s�cei.fi c a t rules are violated,the Company shall have the right r r ..... ...... ............. ......... .............................. INSPECTOR.. .... . ........................... ............... Member N.F.P.A.,I.A.E.I. Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p epart: - am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: 09j el LOCATION: INSPECT ON: X_ TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ chan a of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 59 P.S.I for 15 minutes sulation / Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In1pectioest eive . Queensbury Building&Code Enforcement Arrive: p art: =:aarrxy1pm 742 Bay Road,Queensbury,NY 12804 Inspecto �l P p. NAME: PERMIT#: LOCATION: INSPECT ON: — S TYPE OF STRUCTURE: Y N N/A COMMENTS ming Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 �/z w 16 gauge 8) 16D nails each side ` Draft stopping 1,000 sq. ft. floor trusses Anchor B or less on center I nd water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side t/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Permit Number RFScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck So$ware Version 3.6 Release 2 Data filename: Untitled.rck r,J�itlF(C . 2a13-' �T'601'4-11 6 COUNTY: Warren STATE: New York i3+�ILDa ?AuY°�k HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW/WALL RATIO: 0.18 DATE: 07/26/O5 COMPLIANCE: Passes Maximum UA= 282 Your Home UA= 277 1.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimet R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 960 30.0 0.0 34 Ceiling 2: Flat Ceiling or Scissor Truss 192 30.0 0.0 7 Ceiling 3: Flat Ceiling or Scissor Truss 196 30.0 0.0 7 Wall 1: Wood Frame, 16" o.c. 320 19.0 0.0 16 Window 1: Vinyl Frame:Double Pane with Low-E 14 0.350 5 Window 2: Vinyl Frame:Double Pane with Low-E 14 0.350 5 Window 3: Vinyl Frame:Double Pane with Low-E 14 0.350 5 Window 4: Vinyl Frame:Double Pane with Low-E 14 0.350 5 Wall 2: Wood Frame, 16" o.c. 192 19.0 0.0 12 Wall 3: Wood Frame, 16" o.c. 320 19.0 0.0 19 Window 5: Vinyl Frame:Double Pane with Low-E 8 0.350 3 Wall 4: Wood Frame, 16" o.c. 112 19.0 0.0 5 Window 6: Vinyl Frame:Double Pane with Low-E 36 0.350 13 Wall 5: Wood Frame, 16" o.c. 112 19.0 0.0 3 Window 7: Vinyl Frame:Double Pane with Low-E 14 0.350 5 Door 1: Solid 20 0.350 7 Door 2: Solid 20 0.350 7 —~ Wall 6: Wood Frame, 16" o.c. 96 19.0 0.0 4 Window 12: Vinyl Frame:Double Pane with Low-E 27 0,350 9 —+ Wall 7: Wood Frame, 16" o.c. 128 19.0 0.0 5 --o Window 13: Vinyl Frame:Double Pane with Low-E 41 0.350 14 Wall 8: Wood Frame, 16" o.c. 96 19.0 0.0 3 --® Door 3: Glass 40 0.350 14 Basement Wall 1: Solid Concrete or Masonry 320 19.0 0.0 16 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry 192 19.0 0.0 9 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry 192 19.0 0.0 9 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry 320 19.0 0.0 16 Wall height: 8.0' Depth below grade: 4.0' Insulation depth: 8.0' Window 8: Vinyl Frame:Double Pane with Low-E 6 0.350 2 Window 9: Vinyl Frame:Double Pane with Low-E 6 0.350 2 Window 10: Vinyl Frame:Double Pane with Low-E 6 0.350 2 Window 11: Vinyl Frame:Double Pane with Low-E 6 0.350 2 —� Floor 1: All-Wood Joist/T russ:Over Outside Air 192 30.0 0.0 6 Floor 2: All-Wood Joist/T russ:Over Outside Air 196 30.0 0.0 6 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best ofhis/hcr knowledge, belief and professional judgment, such�pjaffD or specifications are in compliance with this Code. "b Builder/Designer a Date 712,611al RFScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck Soilware Version 3.6 Release 2 DATE: 07/26/05 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] ( 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 3. Ceiling 3: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 3. Wall 3: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 4. Wall 4: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] S. Wall 5: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 6. Wall 6: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ) ( 7. Wall 7: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: j ] 8. Wall 8: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: [ ] ( 1. Basement Wall 1: Solid Concrete or Masonry, 8.0'ht/6.0'bg/8.0' insul, R-19.0 cavity insulation Comments: [ ] ( 2. Basement Wall 2: Solid Concrete or Masonry, 8.0'ht/6.0'bg/8.0' insul, R-19.0 cavity insulation Comments: [ ] 3. Basement Wall 3: Solid Concrete or Masonry, 8.0' ht/6.0' bg/8.0' insul, R-19.0 cavity insulation Comments: [ ] 4. Basement Wall 4: Solid Concrete or Masonry, 8.0'ht/4.0'bg/8.0' insul, R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 2. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 ( For windows without labeled U-factors, describe Matures: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 3. Window 3: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 4. Window 4: Vinyl Frame:Double Pane with Low-E, U-factor 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ )Yes [ ]No Comments: [ ] 5. Window 5: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 6. Window 6: Vinyl Frame:Double Pane with Low-E, U-fictor. 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 7. Window 7: Vinyl Frame:Double Pane with Low-E, U-fictor. 0.350 ( For windows without labeled U-fictors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ )No ( Comments: [ ] ( 8. Window 12: Vinyl Frame:Double Pane with Low-E, U-fictor. 0.350 For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 9. Window 13: Vinyl Frame:Double Pane with Low-E, U-fctor: 0.350 ( For windows without labeled U-factors, describe fixtures: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 10. Window 8: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? ( ]Yes [ ]No Comments: [ ) ( 11. Window 9: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350 ( For windows without labeled U-factors, describe fiatures: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 12. Window 10: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: [ ] ( 13. Window 11: Vinyl Frame:Double Pane with Low-E, U-Wor: 0.350 ( For windows without labeled U-factors, describe features: ( #Panes Frame Type Thermal Break? [ ]Yes [ ]No ( Comments: i Doors: [ ] 1. Door 1: Solid, U-factor: 0.350 Comments: [ ] 2. Door 2: Solid, U-fador: 0.350 Comments: [ J 3. Door 3: Glass, U-factor: 0.350 Comments: Floors: [ ] ( 1. Floor 1: All-Wood Joist/Trass:Over Outside Air, R-30.0 cavity insulation Comments: [ ] 2. Floor 2: All-Wood Joist/Truss:Over Outside Air, R-30.0 cavity insulation Comments: Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must berated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point ofthe largest zone. Electric Systems: [ J Separate electric meters are required fir each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] ( Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State, the Residential Code of New York State or the New York City Building Cade, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ J Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] ( Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ J HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pine Sizes Heated Water Non-Circulating Runouts Circulating Mains and R_u Temperature l F) Un to 1" jjp to 1. " 1.5"to 2.0" Over 2" 170-180 0.5 LO 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thidmess in Inches by Pipe Sizes „ „ Piping System'hypes Range f F) 2"Runouts �, and Less 1,25„to 2„ 2.5„to 4„ Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Stearn Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only)