Loading...
2005-599 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 (Z)w Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20050599 Date Issued: Wednesday, April 05, 2006 This is to certify that work requested to be done as shown by Permit Number P20050599 has been completed. Tax Map Number: 523400-239-012-0002-03 1-000-0000 Location: 95 ASSEMBLY PT. Rd Owner: ROBERT ANDERSON Applicant: ROBERT ANDERSON This structure may be occupied as a: Porch By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, /r Variance, or other issues and conditions as a result of approvals by the Director of B i ding&Code En me Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050599 Application Number: A20050599 Tax Map No: 523400-239-012-0002-03 1-000-0000 Permission is hereby granted to: ROBERT ANDERSON For property located at: 95 ASSEMBLY PT. Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ROBERT ANDERSON JEAN TUMOLO Porch $20,000.00 95 ASSEMBLY PT. Rd Total Value $20,000.00 LAKE GEORGE, NY 12845-0000 Contractor or Builder's Name / Address Electrical Inspection Agency Plans&Specifications 2005-599 320 Q FT PORCH $40.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday, August 12, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o Quee ; ei , 12, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement * 1W -t i 9 Permit No. c�-� Building &Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Dave Hatin,Director codes@gueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Accessory Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Any structure other than the principal structure (i.e., house), typically a garage, shed, greenhouse, dock, deck, etc. (not necessarily limited to the list below). Refer to attached Informational Brochure No. 3 Instructions: A permit must be obtained before beginning construction. No inspections,will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the a ation form. Applicant/Builder Owner: Address: Address: flAlS Home Phone: Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: 'erson responsible for supervision of work with respect to building and codes compliance: Name: 6 61FR,Y 02-S pX / Address: l 1 0 Phone _ocation of proposed construction: Lot No. Legal Address: Ass kky✓f ax Map Number: -3 �� - � Subdivision Name: stimated Cost of Construction: $ Does an accessory structure currently exist on the property? Yes / —No If YES, list all existing accessory structures: t'�}2 rie f Proposed Construction 10 floor 2nd floor Total Proposed Height sq.ft. sq.ff. Sq. f . ft.&in. Open Porch Covered or Enclosed Porch (considered floor area&must comply to FAR [Floor Area Ratio] requirements if the structure is located in the Waterfront Residential zone. ) �� 3-season porch is considered an enclosed porch. Deck Boathouse Boathouse with sundeck DOCK Shed Pole Barn Detached Garage 1, 2, 3 car Other Accessory Structure: applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. 'he Building and Codes Office will allow commencement of your proposed project only after ssuance of your permit. )eciaration: Please sign below after you have carefully read the statement: o the best of my knowledge, the statements contained in the application, together with the plans and pecifications submitted, are a true and complete statement of all proposed work to be done on the described )remises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the )roposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. urther, it is understood that I/we shall submit prior to a Certificate of Oc ancy or Certificate of Compliance )eing issued, as requested by the Zoning Administrator or Director of Bu'ding a (7 odes, an As-Built Survey by a censed suu`ry yor, drawn to scale, showing actual location of all new onstr tion. )ate: S Applicant/Builder Signature: he application of dated is hereby approved and )ermission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set orth above. Date: Authorized Signature: \Sue Hemingway\Building.Permit.FORMS\Accessory Structure Permit Application.doc V:12/28/04 a rJrJEWWrrJt1c.l�cl�r t'�cPtJ�r lrJ�rJ'cnc1� cPtPcJclrJ't1rJ�rJ�r frJrJ'tJ�cPrJrJ�rJcPrJ�cf�cftPrJ�rJrJ�tl�cPc.lac.(c.tc.(r�rJ'rJ�cl�cPc l�ctcfrJ012 IN 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 S NEW YORK BOARD F 5 5 O FIRE UNDERWRITERS 5 BUREAU OF ELECTRICITY 5 40 FULTON STREET — NEW YORK, NY 10038 5 5 CERTIFIES THAT S S S SUpon the application of upon premises owned by 5 c5 5 SWALT'S ELECTRIC ROBERT ANDERSON �5 1 WINDY PONDS LANE 95 ASSEMBLY PT. RD. 5 SALTAMONT, NY 12009, LAKE GEORGE, NY 12845 5 Located at 95 ASSEMBLY PT. RD. LAKE GEORGE, NY 12845 5 5 5 Application Number: 2073100 Certificate Number: 2073100 S 5 c5 5 Section: Block: Lot: Building Permit:2005-599 BDC' A239 5 5 5 5 Described as a Residentiadl 0-599 sviare ft. occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, escribe elow, located in/on the premises at: 5 5 5 5 First Floor,Outside, [, 5 J 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 Sherein, was conducted in accordance with the requirements of the applicable code and/or standard S promulgated by the State of New York, Department of State Code Enforcement and Administration, or other S 5 authority having jurisdiction, and found to be in compliance therewith on the Day of 15th March,2006. 55+ 5 Name OTY Rate Rating Circuit Twe 5 S5 Wiring and Devices 5 Fixture 6 0 Incandescent SReceptacle 4 0 General Purpose Switch 5 0 General Purpose 5 5 Receptacle 1 0 GFCI Outlet 1 0 Tel/CATV 5 Fixture 4 0 Flourescent 5 5 S S S 5 5 5 I of 1 = 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 © r�cr� crct�r rJ�r tcrcncPcrcrcr��1�tnrJtJ�tJrJ�cl�r�r�cl�rPcJ�r.Pcicl�rJrncPcnrJ�c1�rJ�EJ�r.Pr.fcKNOWN] Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: Z* -o �j�am/pm am/pm Date Inspection request received: _ Inspector's Initials: NAME: LV Vie,,%/ PERMIT#: LOCATION: � �� c7 DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy!trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclo ure Final Electrical Sl Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O [Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm Depart: I Warn/pm Date Inspection request received: _ — Inspector's Initials: NAME: PERMIT#: 2i4i�� LOCATION: 4=1 IR ` DATE: TYPE OF STRUCTURE: � n Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: ` �- Z/L�! �� Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area v Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window -- Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/Y4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Is It OW V Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent F� L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised I00405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: am/pm Date Inspection request received: } _ Inspector's Initials: NAME: A*-Iccf PERMIT#: 2 LOCATION: - DATE: TYPE OF STRUCTURE: ._ _� ` 2�- Comments Yes No N/A 1 BuildingNumber/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake YZ 3 inch Plumbing Vent thro um 6 inches 14 Roof Complete(tExtel Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area FumacefHot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched _ Q , Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure � �"` Final Electrical 1 V14. Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O [Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm Depart: am/pm Date Inspection re est received: Inspector's Initials: NAME: PERMIT 0- LOCATION: DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches qq � Bathroom/Kitchen watertight h w" Safety glazing/Window in stairwells safety glazing � Interior Smoke Detectors: 1 Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed r G ss Enclo Final Electrical A Final SurveyPlot P pu As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised—I 00405.doc I GENERAL NOTES: G-1) SURVEY & MAP INFORMATION PROVIDED BY VAN DUSEN AND STEVES, LAND SURVEYORS LLC ENTITLED "MAP OF A SURVEY MADE FOR JOAN B. ANDERSON, ROBERT A. ANDERSON, JEAN A.M. TUMOLO". DRAWING REVISION DATE 06-25-00 AND LIMITED FIELD MEASUREMENTS. MEAN HIGH WATER DRAWING NOTES: LEVEL ELEVATo R Al—1) CONTRACTOR TO PROTECT FIRST FLOOR FROM RAIN AND WIND WHEN ROOF TO FIRST FLOOR IS REMOVED. ,— j ! Al -2) REMOVE ALUMINUN SIDING ALL AROUND ON SECOND FLOOR ELEVATOR SHAFT FOR REPLACEMENT WITH / REMOVE " FACE BOARD SHEET ROCK ON SOUTH AND EAST SIDE, VINYL SIDING ON NORTH AND WEST SIDE. REMOVE THIRD FLOOR ALUMINUM SIDING ON NORTH AND WEST SIDE ONLY FOR REPLACEMENT WITH VINYL SIDING. TO WEST OF ARROW D D -(�-CEILINC HT REM VE WINDOWS IN NOTE: Al-2 CEILING HT ELEVATOR SHAFT 3 84 Al 9 34 -44-CEILING HT — 89 „4 ry REMOVE FACE BOARD 0 1 - STEP In z I o L 1 +C EILING HT --�— —� L CEILING HT �al „ 0 3„ s Q 9 34 Ln -CEILING HT DO „ 894 o STEEL POST (TYP.) r— EXISTING WALLS o I - REMOVE WINDOW 11) REMOVE CEILING MATERIAL a_ I( T - - - - -- - - - - - - _ — c_ - - REMOVE FACING cy REMOVE WONDOW IN I I I -- — - — -- — — — BOARD m WEST WALL — - — � — i f NOTE: Al-1 � REMOVE WINDOW REMOVE ROOF CD 1 47— SHORE LINE — i / �, REMOVE RAILING cy w (M AN HIGH WATER) L— � \ REMOVE FACING / BOARD REMOVE WINDOW r \ - ROOF LINE �--� a- ROOF- LINE - STEPS UNDER RAMP 0 o — COVERED DOCK ROOF LINE OVER STAIRS A EXISTING ELEVATION WITH REMOVAL ' '% -- STAIR WELL WALL 1 REMOVE EXISTING RAILING A.' /; SCALE: sn GRAPHIC scnLE �,I� pyd GRAPHIC SCALE 0 2' 0 1' 2' 4' 8' - REMOVE j" FACE BOARD S TO WEST OF ARROW c 1/4" 1'-0" _. TOWN OF QUEENSBURY V) HATCHWAY TO FURNACE ROOM BUILDING & CO DEPT. ��' Sq 9 REVIEWED BY E A. � fir. �_D DATE 0 AUG 0 3 2005 V EXISTING CONDITIONS / REMOVAL PLAN 'G4NOfQ�fr�I�BIY '�i� ll`C��� Jdf TQ° ,_., itrrtitA �xa1l } ��I, �, SCALE: SEE GRAPHIC SCALE r} Via, o rnr>�DiiA��"� �,ikri V) GRAPHIC SCALE (1) 2' 0 1' 2' 4' 8' _d C Q 1/4 V-0" 08/03/05 AA SUBMITTED FOR PERMIT APPROVAL TSM 0 DATE REV # ISSUED / REVISIONS BY 0 DRAWING: Of NE yr EXISTING CONDITIONS / REMOVAL Al 0 H PORCH ENCLOSURE ANDERSON RESIDENCE Y - ASSEMBLY POINT ROAD c QUEENSBURY, NEW YORK ,07 P� _ JARRETT MARTIN ENGINEERS, PLLC KENNETH A. MARTIN PROFESSIONAL ENGINEERING �- U-) l P.E. # 74334 12 EAST WASHINGTON STREET PHONE: (518) 792-2907 0 COPYRIGHT©2002 GLENS FALLS, N.Y. FAX (518) 798-1864 ONLY COa� L� WING NTH A BLUE SEALIES SHALL BE COOF THIS NSIDERED RED TRUE ANDVAUD JUNE 2005 PRO# 05-015 SHEET: 1 OF 3 0 ALTERATION OF THIS DOCUMENT AWFUL. BY A LICENSED BASESHEET SIZE:22x34 PLOTTED/REVISED.-08/03/05 7:15 AM ENGINEER IS UNLAWFUL. Li GENERAL NOTES: FLASHING UNDER WINDOW TO BE SIMILAR TO SECTION E G-1) SURVEY & MAP INFORMATION PROVIDED BY VAN DUSEN AND STEVES, LAND SURVEYORS LLC ENTITLED "MAP ON DRAWING A3 OF A SURVEY MADE FOR JOAN B. ANDERSON, ROBERT A. ANDERSON, JEAN A.M. TUMOLO". DRAWING REVISION DATE 06-25-00 AND LIMITED FIELD MEASUREMENTS. Lt — -- - — D 00 0 FRAME WINDOW TO Fil ELEVATOR FRAME` F8] O1 i 'I n SHEET RICK 1 a 21 ry c� o z o cn ry Lli I o z E Q A3 co DOOR SCHEDULE Lo DOOR NUM MNFGR MODEL N 3 O M❑ _ U , DESCRIPTION oLn 1 LARSON 248-TL 36" CLASSIC VIEW o 2 LARSON 248-TL 36" CLASSIC VIEW E 3 LARSON 248-TL 36" CLASSIC VIEW a_ 2X4 STUD WALL cy F El WINDOW SCHEDULE 0 i WINDOW MNFGR NUM MODEL NUM DESCRIPTION 1 ANDERSEN WINDOWS 244GW4050 200 SERIES GLIDING 0 WINDOW o I 2 ANDERSEN WINDOWS 244GW4050 200 SERIES GLIDING WINDOW 3 ANDERSEN WINDOWS 244GW4050 200 SERIES GLIDING WINDOW w o o I I F 4 ANDERSEN WINDOWS 244GW40301 200 SERIES GLIDING A3 ! j I - wlNDow I , 5 ANDERSEN WINDOWS 244GW403Q 200 SERIES GLIDING a_ I I WINDOW 6 ANDERSEN WINDOWS 244GW4050 200 SERIES GLIDING 5 - WINDOW o _ 7 ANDERSEN WINDOWS 244GW4050 200 SERIES GLIDING ftf1 WINDOW — — 8 ANDERSEN WINDOWS CN13 200 SERIES CASEMENT .0 J NEW HANDRAIL TO BE -_ - WINDOW �� F0 ALONG EDGE OF STEPS 9* ANDERSEN WINDOWS CN13 200 SERIES CASEMENT E j I�� WINDOW ROOF LINE —` I 10 ANDERSEN WINDOWS P3030 200 SERIES CASEMENT �- WINDOW WINDOW 9 ON THIRD FLOOR TO BE INSTALLED IN o LINE WITH WINDOW 8 Q C A3 4 o + -- --- — V) -- -- Q 08/03/05 AA SUBMITTED FOR PERMIT APPROVAL TSM o L DATE REV SUED / REVISIONS BY 0 oc WALL/ STAIRS LAYOUT PLAN DRAWING: •o A2 EXISTING CONDITIONS f REMOVAL PLAN Z PORCH ENCLOSURE �J SCALE: SEE GRAPHIC SCALE ANDERSON RESIDENCE - Y ASSEMBLY POINT ROAD GRAPHIC scab a7a ° QUEENSBURY, NEW YORK i' o 6 r 2' a' SCAM Q 1�2" = 1._D. JARRETT — MARTIN ENGINEERS, PLLC a KENNETH A. MARTIN PROFESSIONAL ENGINEERING .. o P.E. # 74334 12 EAST WASHINGTON STREET PHONE: (518) 792-2907 COPYRIGHT©2002 GLENS FALLS, N.Y. FAX: (518) 798-1864 a� ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED UE -1 ANDVAUD TR JUNE 2005 PRO# 05-015 SHEET: 2 OF 3 6 ALTERATION OF THIS EERISUNT AWFUL. BASESHEET SIZE:22x34 PLOTTED/REVISED:08/03/05 7:15AM BY A LICENSED ENGINEER IS UNLAWFUL. , I i 1 VINYL SIDING 2x6 STUD WALL @ 16" O.C. WITH 0 FURRING STRIP — " DRYWALL EXISTING -1 @ 16" O.C. — 6" BATT INSULATION BUILDING I I I II II II II iI It II II II EXIST IN G EXTERIOR SHEATHING ELEVATOR SHAFT — TYVEX AS REQD "J" MOLD — VINYL SIDING 7 3 ALUMINUM FLASHING A3WALL FLASHING P. T. CANT BLOCKING VARIES 121 2 9 u u LL VARIES _2 EXISTING DECK CD o -_ FACE OF STAIRWAY jj II II II II I D FLASHING AT ELEVATOR SHAFT SECTION /, SCALE: 3" = 1'-0" AT EAST CORNER II II II II II /`+`L o II II II II II _f cn - - o FACE OF STAIRWAY Q AT WEST CORNER In 0 00 o ' B PROPOSED WEST ELEVATION I; PROPOSED SOUTH ELEVATION In A� SCALE: SEE GRAPHIC SCALE VIIL2 / SCALE: `SEE GRAPHIC SCALE GRAPHIC SCALE GRAPHIC SCALE 2" EXTERIOR SHEATHING L CAIE VINYL SIDING EXISTING DECKING; SEE 0 SECTION G ON DRAWING A3 NEW DOOR 2" DRYWALL "J" MOLD 100, NEW DOOR SILL ALUMINUM FLASHING — P.T. CANT STRIP BEHIND VINYL SIDING 0 AND WINDOW FLASHING In 2 METAL FLASHING 4" PLYWOOD WITH 2x6 STUB @ 16 O.C.; EXISTING DECK—\ 2 SPF OR BETTER (TYP.) (2) 2x6 SILL ROLL ASPHALT ROOFING I # _ BLOCKING (P.T.) P T. WOOD BLOCKING 16" ALUMINUM DRYWALL FOR }� (AS REQ'D) FLASHING CEILING FINISH / \ _ SOFFIT & 6" BAT �'`—� FASCIA EXTEND FLASHING INSULATION 2x6 RAFTERS 2'-0" (MIN.) @ 25" Q.C. - SILL PLATE 2 x 4 CEILING RAFTER EXISTING BUILT—UP ROOF DECK (MATCH EXISTING WALL STUDS) WINDOW — SEE SCHEDULE ON DRAWMG A2 F DOOR SILL FLASHING SECTION A� SCALE: 3" = 1'-0" a> o Q EXISTING GRANITE DECK TO BE 3 WALL FLASHING DETAIL EXTERIOR SHEATHING REMOVED DECKING TO BE REPLACED SCALE: 3" = 1'-0" WITH TYVEX AS NEEDED; INSTALL "NOBLE DECK" OR A3 / 4" EQUIVALENT PER MANUFACTURER c (MIN.) RECOMMENDATION o co VINYL SIDING -__- 4 0 Q (MIN.) Ln SUBDECK NOBLE DECK OR 08/03/05 Ak SUBMITTED FOR PERMIT APPROVAL TSM In 6" BATT INSULATION BLOCKING AS REQ'D EQUIVALENT DATE REV # ISSUED / REVISIONS BY coMETAL FLASHING BY DRAWING: "J" MOLD SIDING CON TOR BUILDING ELEVATIONS / DETAILS A3 H A. ° ALUMINUM FLASHING 2 DRYWALL PORCH ENCLOSURE ANDERSON RESIDENCE Y P.T. CANT BLOCKING NEW VINYL SIDING �' i I ASSEMBLY POINT ROAD t� QUEENSBURY, NEW YORK EXISTING ROOFING _ JARRETT - MARTIN ENGINEERS, PLLC EXTEND FLASHING KENNETH A. MARTIN PROFESSIONAL ENGINEERING In 2'—0" P.E. # 74334 12 EAST WASHINGTON STREET PHONE- (518) 792-2907 N COPYRIGHTO2002 GLENS FALLS, N.Y. FAX (518) 798-1864 , \ G FLASHING AT THIRD FLOOR PATIO SECTION ;l E EAST WALL SECTION SECTION Az JUNE 2005 PRO# 05-015 SHEET: 3 OF 3 ONLY COPIES OF THIS DRAWING WITH A � \ SCALE; 3" = 1'-O" BLUE SEAL SHALLAND VALID CONSIDEREDTRUE j = - A2 �/ ALTERATION OF THIS DOCUMENTB(CEPT BASESHEET SIZE:22x34 PLOTTED/REVISED.-08/03/05 7:15AM BY A LICENSED ENGINEER IS UNLAWFUL. Li