Loading...
2005-610 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE C3F OCCUP-A-NCY Pennit Number. P20050610 Date Issued: Monday, April 02, 2007 This is to certify that work requested to be done as shown by Permit Number P20050610 has been completed. Tax Map Number. 523400-301-005-0001-035-000-0000 Location: 14 QUEENS Ln Owner. PAUL & HOLLIS SCHULZE Applicant: PAUL & HOLLIS SCHULZE This structure may be occupied as a: Residential Addition By Omer of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the (—: , �G property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050610 Application Number: A20050610 Tax 1\Iap No: 523400-301-005-0001-035-000-0000 Permission is hereby granted to: PATfI, & 1401,LISSCM1I,ZF, For property located at: 14 QUEENS L11 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: PAUL&HOLLIS SCHULZE 14 QUEENS Ln Residential Addition $85,000.00 Total Value $85,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name / Address Electrical Inspection Agency WEST. WILLIAM Plans& Specifications 2005-610 683 SQ FT RESIDENTIAL ADDITION $81.96 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, August 23, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T Queen bury; u day,August 23, 2005 SIGNED BY for the Town of Queensbury. Director of Building Code nforcement Check Residential Plan Review: One& Two Family Dwellings N/N/A (2)Full sets of plans ver 1,500 sq. 1.— t d Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. G Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height.above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans -Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors MpWtairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise YJA Winder Run and Rise Spiral Not Allowed From 2d Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped �• Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed WINDOW SCHEDULERECr:IVED Job Site/Address: ✓Y ott,rr-v s L e►w p Date: r AUG 0 5 2005 Owner: Application No. T01NN Cf ' ' V Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening GlassNis Egress/Cie Opening Opening or Instructions Letter on Name Numbe g Height able Vent ar Width In Height Plan Cali Width Light g Opening Inches In Inches // Size _ go2216 D1j 26216 .1ZV$, 3`1 1- 3,`IS1� r „ �� l�aT o Ekca F�vo 6-8' Y6 � 71 dh$ c Example Entry A Andersen Narrollne 3062 3' 2 6'5 '/z 15.30 8.36 6.01 34 2415135" Tempered Double 113" 11116 Glazing Hun CADocuments and ScWngs\Sue\Loca1 Settingffemp\Window Schedule.doc RI= ED Job Site Address: f It Q4 e-ew Lne. I C F Date:,. I/ /(P l e qU f 0 5 2005 Owner: Qccc t,tti�� Sc,�u��zc App�lMaf iop Ng,`�.tMiRY File No. Building Permit Calculation. Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req. Light Actual MW Req.Vent .Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet V $, q � L:\S u eH emi n gway\B ull ding.Permit.FORMS\Nat.Light.V entil.0 alculation.Sh eet.d oc Permit No. �,-�.������� Building P&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensbury,net ` Phone: (518) 761-8256 FAX: (518) 745-4437 Ems. Principal Structure Building Permit Applicaug, P5 k, p z«u Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be mt�Il_the; applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. A wilder it�`t,`1Gtv►t W� Lt.�Ps Owner: Q��,J eta g C 41 fiz f Address: �3 rr �gsti ST�c�� Address: 14 QU e%5: L c c e v 11, I Z B e y Chu r-e-ns b` n:i, Home Phone: 9?3- q&43J Home Phone: 9007 Email Address: Sca-LI We&,e Wet Pinta • -A e-T Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: 3COW Wes 7 Address: u%1515c4 s i- QtlrCuS a�� 71.E-t i2-Src4 Phone ?q3 y!a yJ Location of proposed construction: Lot No. Legal Address: QU et' i�A -f 05 6Gab Tax Map Number: .S2 y00 -361- C5b5- 1 �3S`� Subdivision Name: Estimated Cost of Construction: $ Ibaa Proposed construction is for: Residential Use _Commercial Use Name of Business: It proposed construction is an addition,what will use of new addition be? ►►r�u ���1! / New Addition Alteration Proposed Construction tst Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq. Ft. Square feet Height Ft.&in. Single-Family Dwelling Two-Family Dweilin Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil, Gas, ood, Forced Hot Air, Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes —No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after Issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. Date: 211 -LoyApplicant/Builder Signature: r t r�� � The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: Z" Authorized Signatur L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc v:12/14/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/prqD�Depart: � am/pm Date Inspection request received: Inspector's Initials: 1 NAME: PERMIT#: LOCATION: L CZ L , DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Com lete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill late Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s . ft.vents Bathroom Fans,if no window Plumbin fixtures Foundation insulation. Floor truss,draft stopping finished basement 1,000 s .ft. Emergency EmEgency egress below grade Gas Furnace shut-off within 30 feet or within line of site f� Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum asement stairs closed rise>4 inches Gana e Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Tempor /Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc rw Queensbury Building & Code Enfoteem t - Residential Final Inspection Office No.(518)761-8256 Arrive: ?;: am//ppm Depart: am/pm Date Inspection request received: Inspecto s Initials: -_ —, _ NAME: PERMIT#: LOCATION: _ DATE: TYPE OF STRUCTURE: Comments BuildingYes No N/A FA310 Number/Address visible from road � 6 Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake p, 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade IrIterior privacy/trim/doors/main entrance 36 inches athroom/Kitchen watertight 01 Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/s"Gypsum Basement stairs closed rise>4 inches garage Floor Pitched "Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes FormslBuilding&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspect n Office No. (518)761-8256 Arrive:4In am/RV,6part: _ am/pm Date Inspection request received: i�q/JAN Inspects: NAME: C. PERMIT#: � LOCATION: DATE: ket TYPE OF STRUCTURE: Com '`r' Ye No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight / Safety glazing/Window in stairwells safety glazing /✓f11%�� 74�� s S Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed pro erl Gas Logs in Sealed or Qjj4sW Vi*)osure Final Electrical Final Survey Plot Pl As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required / Okay to issue C/C or C/O Temporary/Permanents JJ L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc 7��` 5 /73 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. VS Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL \ Permit No........... ...........................Cert. jNJ2 94034 Cut-in Card No................................... Owner..................... ..... Location.....`....... Q`('G�A /' ..... :................................................................ Installation Consisting of...t,0,0 ..n�4) P)l/:A/ ��................................... .... .................. ................ .................................................................................................................................................................................. .............................................................. ................................................................................................................ Installed By ar ... .......................................................................Lic.No................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon th, introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin m ections at any time, and if it rules are violated,the Company shall have the right to YeAke his a cafe. Date.... ................ INSPECTOR... . . ............................................................................... /G - /1-1? &/P--- Rough Plumbing / Insulation Inspection Report , Office No. (518) 761-8256 Date Inspecti n eq est received: Queensbury Building & Code Enforcement Arrive: S am/pmH` mom , Apart: am , 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �"'� NAME: PERMIT #: / LOCATION: 14 Otir 13 INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size / /a�� � � WashingMachine Drain 2 inch minimum �/ Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50..Q .I for 15 minutes nsulati Residential Check Commercial Check r Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace ct work sealed ro erl No duct to e ,'� � COMMENTS: LAPam Whiting\Building&CodesUnspection FormsURough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing 0 Insulation Inspection Report Office No. (518) 761-8256 Date InspeLion equest received: Queensbury Building & Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's nitials: NAME: PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place " 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft, above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Ins ion Z Residential Check Commercial Check ro er Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing / Firestopping Inspect4ese Office No.(518)761-8256 Date Inspection (Queensbury Building&Code Enforcement Arrive: '742 Bay Road,Queensbury,NY 12804 Inspector's Initia NAME: f' PERMIT#: 4C- YLOCATION: INSPECT ON: TYPE OF STRUCTURE: N N/A Framing COMMENTS � � Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Ptate 1 %2 w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center an waters •eld 24 inches from wall C/ Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report (APIV Office No. (518) 761-8256 Date Inspection request received: --� Queensbury Building&Code Enforcement Arrive:-am/\ apart am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: 0 TYPE OF STRUC Y N N/A COMMENTS ming Attic Access 22"x 30"minimum Jack Studs/Headers 0g � Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ic nd water shield 24 inches from wall tL�'" , �f A,TZA e' i Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %s inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade (-3 ryv- Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 11 z j Queensbury Building&Code Enforcement Arrive: anv Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _ NAME: _ �C:`��''t Z_� PERMIT#: LOCATION: 14_OLUettg-rrz� _ INSPECT ON: j_ 0 TYTE OF STRUCTURE: -' Comments Y N N/A Footings ---------'-- Piers ^ Monolithic:-!-9 Slab ein nt. ace "J�t� i The contractor is responsibly for pro i i reezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: _ 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval _ Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I ASuencmingway\Building.Codes.Inspection.FORM Sllroundation Inspection Report.doc .January 28,2003 /^ J Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: lU Queensbury Building&Code Enforcement Arrive: anvp Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: T1 NAME: _ �j_L��L,,� Z _ PERMIT#: LOCATION: _ ����� T INSPECT ON: TYPE, OF STRUCTURE: Comments Footings _ Piers Monolithic Slab -a Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pose on site. _ Foundation/Wallpour Reinforcement in Place Foundation Damppro(;hng Foundation/Waterproofing Type of Dampprooling/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: _ 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper I G/L/TIJ Foundat' su tion tern /E. r Rough Grade 6 inch drop within t ft. L\SueHemingwayBuilding.Codes.InspectionTORMSU'oundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: v Queensbury Building&Code Enforcement Arrive: am/pm��Depart: � wm/pm 742 Bay Rd., Queensbury,NY 12804 Inspectors Initials: - NAME: G 1^�- t.� r - PERMIT #: LOCA'CION: � (�i �� �_���— _ INSPECT OK-.- -.: TYPE OF S"IRUCTURE: LU 4� G U Comments ---------i------ -- Y N N/A Footings (i Piers Monolithic - Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing "Type of Dampproofing/Waterproofing I 1 Footing Drain Daylight or Sump Footing Drain Stone: _ 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfrll-Approval ing Under Slab PVC Cast/Copper '14ndation Insulation Interror/yx- r R- _ Rough Grade 6 inch drop within 10 ft. LASuMcmingwayiBuilding.Codes.Inspection.FORMSUro T ction Report.doc January 28,2003 V1 Foundation Inspection Report P � Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anvp Depa �_Q�mlpm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ S ` I Z e AL11 ej / PERMIT#: —_-o Wo LOCATION: L, T INSPECT ON: TYPE.OF STRUCTURE: Comments N N/A Footings ---------_____----._—_--- Y Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pu—pr ose on site. Foundation/Wallpour i Reinforcement in Place oundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab ZZ V 1 L>t0JG T /�.� /NA iZ^D C e1 ackfill Approval 1J C� Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASucHcmingway\Building.Codes.Inspecti on.FORM SToundation Inspection Report.doc January 28.2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection Pp e _ Queensbury Building&Code Enforcement Arrive: Depart: a pm 742 Bay Rd., Queensbury,NY 12804 Inspector's In ti NAME: _ � --_-(DOS, l_ LOCA'CIUN: O.r) INSPECT ON: TYPE OF STRUCTURE: — . �, Comments N N/A Z ' LA I+YUIJ� Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement ]��1 the concrete.M Materials for this purpose on site.____ Foundation/Wallpour "gyp Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproof"ing �� Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width �® C 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHeiningway\SuiIding.Codes.Inspection.FORMS\Foundation Inspection Report.doc .ianuary 28,2003 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No......... .....s................. Cert. 84772 Cut-in Card No.............................:..( Owner..............�.........�r..�........T1I ................................................................................................... Location.../.y......C�G��.c-t....... ...N:.......................................... /ter'-'�...... ................... Installation Consisting of..... ...5�..�...'!/ TZ`....f /6..n�z-�`.P 7... 1........:.....:.................... ......... .... .................................................................................................................................................................................. .................................................................................................................................................................................. Installed By........W. ... � ...........................................Lic.No................................................. ........ .... The conditions following governed the issuance of this certificate,and any certificate previously issued i cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon th introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of maki m ections at any time, and if it rules are violated,the Company shall have the right to r�vpke thi c ' scat L R./�l; Date.....Z....�.......�.................. INSPECTOR..................... ........ ................................................... REScheck-Web: Project Information Page I of I t C�J( � REScheck-Web Code/Location = Construction Type Code: New York * 1- and 2-Family, Detached State: New York 0 Multifamily County: Warren If your city or county is not included here,choose a nearby location with similar weather conditions. Heating System Type O Electric(includes heat pumps) Non-Electric Project Description Project Title: Date of Plans: Schultze addition August 2, 2005 Designer/Contractor: Dave Schultze/W. Scott West Project Description: attached addition Project Notes: �Qss�� � � >•G http://energycode.pnl.gov/REScheckWeb/Project.jsp'. pd teLocations=no&codeChange=Fa... 8/2/2005 REScheck-Web: Envelope Assemblies Page 1 of 1 CNI'JREScheck-Web TM Schultze addition—Code:New York Cavity Continuous Assembly Gross Area R-Value R-Value U-Factor 1 Ceiling: Raised or Energy Truss 306 ft2 38.0 0.0 2 Ceiling: Flat or Scissor Truss 193 ft2 38.0 0.0 3 Wall: Wood Frame, 16in.o.c. 136 ft2 19.0 0.0 4 Wall: Wood Frame, 16in.o.c. 296 ft 19.0 0.0 5 Wall: Wood Frame, 16in. o.c. 248 ft2 19.0 0.0 6 Wall: Wood Frame, 16in.o.c. 112 ft2 19.0 0.0 hi tp;//erg d.gov/REScheckWeb/enveloped 8/2/2005 REScheck-Web: Mechanical Equipment Page 1 of 1 C*,J(REScheck-WelbTM Schultze addition--Code:New York Heating Cooling Minimum Equipment Efficiency Efficiency Efficiency 1 Boiler: Other(Except Gas-Fired Steam) 85.0 AFUE 80.0 AFUE http://energycode.pnl.gov/REScheckWeb/mechanical.jsp 8/1/2005 a /0 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le Data filename:Untitled.rck PROJECT TITLE: 14 Queens Lane COUNTY:STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached I or 2 Family HEATING TYPE:Non-Electric DATE:07/30/05 DATE OF PLANS: 3-28-2005 PROJECT DESCRIPTION: Addition to Single Family Residence COMPLIANCE:Passes Maximum UA=210 Your Home UA= 185 11.9%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 638 38.0 0.0 19 Wall 1: Wood Frame, 16"o.c. 1026 21.0 0.0 52 Window 1:Wood Frame:Double Pane with Low-E 69 0.340 23 Door 1: Solid 20 0.200 4 Door 2: Glass 33 0.340 11 Floor 1: Slab-On-Grade:Heated 114 12.0 76 Insulation depth:6.0' COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer !► 0 A q Date p?HOZQ or a REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ie DATE:07/30/05 PROJECT TITLE: 14 Queens Lane Bldg. ( Dept. Use I ( Ceilings: [ ] j 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation j Comments: ( ( Above-Grade Walls: [ ] ( 1. Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity insulation ( Comments: I ( windows: [ ] j 1. Window 1: Wood Frame:Double Pane with Low-E,U-factor:0.340 j For windows without labeled U-factors,describe features: ( #Panes Frame Type Thermal Break?[ ]Yes[ ]No ( Comments: ( ( Doors: [ ] ( 1. Door 1: Solid,U-factor:0.200 j Comments: [ ] ( 2. Door 2:Glass,U-factor:0.340 j Comments: I ( Floors: [ ) ( 1. Floor 1: Slab-On-Grade:Heated,6.0'insulation depth, ( R-12.0 continuous insulation ( Comments: j Slab insulation to extend down from the top of the slab to at least 6.0 ft. OR down to at ( least the bottom of the slab then horizontally for a total distance of 6.0 ft. ( Exterior insulation must have a rigid,opaque,weather-resistant protective covering that ( covers the exposed(above-grade)insulation and extends at least 6 in.below grade. I ( Air Leakage: [ ] ( Joints,penetrations,and all other such openings in the building envelope that are sources of air ( leakage must be sealed. [ ) j Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a ( 3"clearance from insulation. I ( Vapor Retarder: [ ] ( Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. i ( Materials Identification: [ ] ( Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ J i Materials and equipment must be identified so that compliance can be determined. [ J j Manufacturer manuals for all installed heating and cooling equipment and service water heating j equipment must be provided. [ ] j Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. i tr { Duct Insulation: [ ) ( Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ } I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ j I Supply ducts in unconditioned spaces must be insulated to R-I 1. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: I I I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] ( Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system, [ } I The HVAC system must provide a means for balancing air and water systems. I I Temperature Controls: [ } ( Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space I temperature set point of the largest zone. I I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. ( Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ) I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. I Service Water Heating: [ } I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ } I Insulate circulating hot water pipes to the levels in Table 1. ( Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% I of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] ( HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts I"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) F2o3r w4i, nn �'I� � ScAee&ee- oJZ; rou 7 ZOD r G!d �roo 2 d O I 11"M 0""C4ox ba/;7 ' + 1 I I � � f I � !Ze Z ccnT�yS i x ccRc s F%//e-1 wo-t, c cm c ve Tc '6 y ' S co!t ltJrs E � G. Peter Jensen 17 West Road South Glens Falls New York 12803 (518) 798—3859 J July 30, 2005 To Whom It May Concern: I have reviewed a set of drawings for a single story addition to a single family residence located at 14 Queens Lane, Queensbury, Warren County New York. The addition is of slab on grade construction. The footings are indicated to be 16"X 8" poured concrete. Three deformed reinforcing bars need to be added to the footing. The 8"thick poured frost wall is adequate for the conditions indicated. The '/2" diameter anchor bolts through the pressure treated mud sill are adequate, at the spacing indicated. The 9 foot high exterior walls are indicated to be constructed of'h" gypsum on 2 X 6 studs with '/2"thick structural sheathing, building paper and siding. The roof is shown as being asphalt shingles on asphalt saturated felt paper on 5/8"thick structural sheathing on 2 X 10 rafters, which are spaced 16" on center. The rafters are adequate for the anticipated loads. The header over the French doors in the Study should be 2 pieces of 2 X 10. The header over the opening in the front wall of the Patio should be 2 pieces of 1- 3/4" X"11-7/8"LVL material. The insulation within the exterior walls should be changed from R-19 to R-21. The R-38 insulation in the flat ceiling area is appropriate. The R-38 insulation in the sloping ceiling must be changed to R-30 insulation between rafters with R 8 rigid insulation over the inside face of rafters, in order to maintain adequate air flow above the insulation. The indicated windows are adequate to provide emergency egress and the required percentage of light area. A carbon monoxide detector will have to be added in the area of the addition. The window in the bathroom must be glazed with tempered glass. The grade adjacent to the house must be pitched away from the house at a rate 5%. It would appear that the addition will meet the set-back requirements. Sincerely; $ttIk& Apoy� �'rl SIR ►�CN� ter. p, Fy G. Peter nsen ` t � �2802a OF