When we arrived,
m
YOUR DUCTS HAD: -s 200
u
437.2 CFM of Leakage, equivalent to a
82.6 Square Inch Hole 100
This equals 262.3 refrigerators full of air loss every
hour,
After we finished,
YOUR DUCTS HAVE: 0 5 10 15 20 25 30 35
15.2 CFM of Leakage, equivalent to a Sealing Time"n Minutes
2.9 Square Inch Hole
This corresponds to a 96.5% Reduction in Aeroseal Technician Kai Swanson
Duct Leakage. Aeroseal Case ID 5068
Date of Seal 5/18/2020
Note: Duct Leakage results are calculated in System Description Basement Upflow
Cubic Feet per Minute (CFM) measured at a Seal Description Supply Upflow
standard OPERATING PRESSURE of 25 Pa. Hardware HomeSeal Connect