AST-0344-2020 (2) J4ir{ t.r ' tjr 3 J F c e+... I{R1aJ' ff•�",.'a ...J J13Ilfl.� ,�:..i��a, R3Ilfl.8.fl IO/fl�xi�nenun s➢o ne. Ramps serving �9�9LDQ�96�,P4.��94�96�G door required byg the egress more than 1 unit Verticalin shall have a slope of not units horizontal (8.3(8.3-per- cent slope).Other ramps shall have a maximum slope of 1 63 unit vertical in 8 units horizontal(12.5 percent). I IException:Where it is technically infeasible to comply !because of site constraints,ramps shall have a slope of snot more than 1 unit vertical in 8 units horizontal(12.5 percent). 311.8.2 Lon Tngs required. There shall be a floor or landing at the top and bottom of each ramp, where doors open onto ramps,and where.ramps change directions.The width of the landing perpendicular to the ramp slope shall be not less than 36 inches(914 mm). I•:311.8.3 nndrui➢s required. Handrails shall be pro- vided on not less than one side of ramps exceeding a slope of'one unit vertical in 12 units horizontal (8.33-percent slope). r;31Il.8.3.1 I eight. Handrail height, measured above the finished surface of the ramp slope,shall be not less than 34 inches (864 mni) and not more than 38 inches (965 mm). 311.8.3.2 Grip size.Handrails on ramps shall comply with Section R311.7.8.5. R311.8.3.3 Conthu ity. Handrails where required on ramps_shall be continuous for the full length of the ramp.Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches (38 mm)between the wall and the handrails. •